Analog Devices

MAX190ACWG - 12-Bit 75ksps SAR ADC, SOIC-24 | Analog Devices

料号: MAX190ACWG ✗ 停产
有现货 1-3 个工作日内发货
4.75 V to 5.25 V (single +5V supply) Vdss 3 mA (active), 60 µA (power-down) Id 24-pin SOIC (wide, 7.5 mm body width) Package 2.5 MHz to 5 MHz Speed
低至 $16.2 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-14
批量定价
数量 单价 小计
1 $24.52 $24.52
10 $22.1 $221.00
100 $19.45 $1,945.00
500 $17.8 $8,900.00
1,000 $16.2 $16,200.00
ℹ️ 所有价格均以 USD 计价

MAX190ACWG 概述

The Analog Devices (formerly Maxim Integrated) MAX190ACWG is a low-power, 12-bit sampling analog-to-digital converter (ADC) with internal reference and power-down capability, housed in a 24-pin wide SOIC (WG) package. It delivers up to 75 ksps throughput from a single +5V analog supply, drawing only 3 mA quiescent current during conversion and dropping to 60 µA in software-controlled power-down mode. The device integrates an internal 4.096V bandgap reference, a successive-approximation register (SAR) architecture, and an on-chip sample-and-hold amplifier.

An ADC (Analog-to-Digital Converter) is a data-acquisition component that converts continuous analog signals into discrete digital codes. The MAX190 belongs to the SAR (Successive Approximation Register) family of ADCs, which sit in the broader hierarchy: SAR ADC -> data converter -> ADC/DAC -> signal-chain IC -> semiconductor. SAR ADCs offer a strong balance of speed, resolution, and power for multiplexed or single-channel precision measurement in industrial, instrumentation, and process-control systems.

Key features of the MAX190ACWG include ±0.5 LSB integral nonlinearity (INL) in the A-grade, internal low-drift reference, software-configurable unipolar (0 to +5V) or bipolar (±5V) analog input range, and a Byte-wide parallel data interface. The device requires an external 2.5 MHz to 5 MHz serial clock, and its 100 ns acquisition time supports full 75 ksps conversion throughput on a single acquisition/conversion cycle. The integrated reference eliminates the need for external precision components, reducing BOM cost and PCB area.

Typical applications include data-logging systems, pen digitizers, portable instrumentation, industrial process control, and battery-powered measurement equipment where the 60 µA power-down mode significantly extends battery life. The MAX190ACWG is the commercial temperature grade (0°C to +70°C), while the MAX190AEWG is the extended temperature grade (−40°C to +85°C) for harsher environments. Designers should add a 10 µF bypass capacitor on the analog supply and follow standard ADC layout practices — keep analog and digital ground planes separate and connect them only at a single point near the IC.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone, helping engineers evaluate the MAX190ACWG for both new designs and legacy maintenance.

直接替换替代料: MAX190ACWG ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

MAX190AEWG+

✅ 直接替换
📦 24-pin SOIC (WG)
extended temperature grade (−40°C to +85°C vs 0°C to +70°C), otherwise identical electrical specs and pinout

📋 参考替代料(不在目录中)

MAX190BCWG+

✅ 直接替换
📦 24-pin SOIC (WG)
B-grade with ±1 LSB INL (vs ±0.5 LSB A-grade), otherwise same 75 ksps, same reference, same pinout

📋 参考替代料(不在目录中)

MAX190BEWG+

✅ 直接替换 ⚠️ 规格未核验
📦 24-pin SOIC (WG)
B-grade + extended temp (−40°C to +85°C), combined lower linearity + wider temp window vs commercial A-grade

📋 参考替代料(不在目录中)

MAX190ACWG+

✅ 直接替换
📦 24-pin SOIC (WG)
lead-free / RoHS-compliant version of MAX190ACWG (commercial temp, A-grade)

📋 参考替代料(不在目录中)

MAX190BCNG

✅ 直接替换
📦 24-pin DIP (NG)
same die, B-grade (±1 LSB INL), through-hole DIP-24 package instead of SOIC-24 — pinout differs from SOIC

📋 参考替代料(不在目录中)

MAX190ACWG 最大额定值与电气特性

分辨率 12 bits
Sample Rate 75 ksps
Architecture SAR (Successive Approximation Register)
Number of Channels 1 input
Analog Supply Voltage 4.75 V to 5.25 V (single +5V supply)
Digital Supply Voltage Compatible with +5V logic
Analog Input Range 0 V to +5 V (unipolar) or ±5 V (bipolar, software-configurable)
Integral Nonlinearity (INL) ±0.5 LSB (A-grade, max)
Internal Reference Voltage 4.096 V
静态电流 3 mA (active), 60 µA (power-down)
Input Acquisition Time 100 ns
External Clock 2.5 MHz to 5 MHz
Data Interface Byte-wide parallel
工作温度范围 0 °C to +70 °C (commercial, AC suffix)
封装 24-pin SOIC (wide, 7.5 mm body width)
安装类型 Surface Mount
RoHS 状态 Compliant (lead-free + suffix)

MAX190ACWG 引脚配置

SOIC-24 Package Pinout Diagram SOIC-24W 24-pin, 7.5x15.4mm, P1.27mm, JEDEC MS-013. 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 SOIC-24
引脚 1 AGND — Analog ground
引脚 2 AIN — Analog input
引脚 3 AGND — Analog ground (sense pin)
引脚 4 REF — Internal 4.096 V reference output
引脚 5 REFADJ — Reference adjust input
引脚 6 AVDD — Analog +5 V supply
引脚 7 DVDD — Digital +5 V supply
引脚 8 DGND — Digital ground
引脚 9 DOUT11 — Data output bit 11 (MSB)
引脚 10 DOUT10 — Data output bit 10
引脚 11 DOUT9 — Data output bit 9
引脚 12 DOUT8 — Data output bit 8
引脚 13 DOUT7 — Data output bit 7
引脚 14 DOUT6 — Data output bit 6
引脚 15 DOUT5 — Data output bit 5
引脚 16 DOUT4 — Data output bit 4
引脚 17 DOUT3 — Data output bit 3
引脚 18 DOUT2 — Data output bit 2
引脚 19 DOUT1 — Data output bit 1
引脚 20 DOUT0 — Data output bit 0 (LSB)
引脚 21 BIPOLAR — Input range select: LOW = 0-5V, HIGH = ±5V
引脚 22 CLK — External clock input (2.5-5 MHz)
引脚 23 CS — Chip select (active low)
引脚 24 HBEN — High-byte enable for byte-wide read

典型应用

MAX190ACWG 适用于 6 应用s: Industrial Process Control / PLC Analog Input Modules, Portable Data Loggers, Pen Digitizers and Tablet Input, Test & Measurement Instrumentation, Medical Monitoring Equipment, Battery-Powered Measurement.

🏭

Industrial Process Control / PLC Analog Input Modules

The MAX190ACWG's ±0.5 LSB INL and software-configurable 0-5 V / ±5 V input range make it well suited for industrial PLC analog input modules. Its internal 4.096 V reference eliminates an external reference component, simplifying BOM and reducing drift over temperature. At 75 ksps it samples 4-20 mA-conditioned signals or direct thermocouple/bridge outputs through a front-end mux, while the 60 µA power-down mode supports low-duty-cycle scan architectures. Designers should add 10 µF + 0.1 µF supply bypass and keep analog/digital grounds separated to a single point.

🔋

Portable Data Loggers

The MAX190ACWG is well matched to portable data loggers because its 60 µA power-down mode dramatically extends battery life between sample bursts, and the integrated 4.096 V reference removes the cost and current draw of an external precision reference. The 75 ksps sample rate easily handles multi-channel sensor scans through an external mux, while the 12-bit resolution covers temperature, voltage, and strain-gauge measurements with adequate dynamic range. The byte-wide parallel interface supports a quick read-out to a microcontroller or low-power FPGA during periodic wake-up cycles.

🧩

Pen Digitizers and Tablet Input

The MAX190ACWG's 75 ksps sampling rate and 100 ns acquisition time are well suited to pen-digitizer and tablet-input applications, where the digitizer must capture stylus position updates at high refresh rates. Its internal reference simplifies the analog front end, and the 12-bit resolution delivers 4096 levels per axis — sufficient for sub-pixel tablet accuracy. The parallel data interface allows a host microcontroller to read coordinates quickly between display refresh cycles. The commercial 0-70°C range covers indoor use; choose the MAX190AEWG for outdoor tablets.

🔧

Test & Measurement Instrumentation

For bench-top and rack-mount test instruments, the MAX190ACWG's ±0.5 LSB INL and internal low-drift reference provide the linearity needed for accurate voltage, current, and sensor measurements. The byte-wide parallel output simplifies connection to legacy 8-bit microcontrollers and DSPs without a serial-interface controller. The 75 ksps rate is sufficient for non-oscilloscope measurement instruments — DMMs, source-measure units, and dataloggers — and the ±5 V bipolar range allows direct digitization of signals without external conditioning.

💊

Medical Monitoring Equipment

The MAX190ACWG's 12-bit resolution and ±0.5 LSB INL are well suited to medical monitoring equipment like bedside patient monitors, where the ADC digitizes filtered ECG, SpO2, or temperature signals. The internal reference removes drift concerns that plague external references in long-life medical devices. The 60 µA power-down mode extends battery life on portable patient monitors. The commercial 0-70°C range covers most clinical environments; for ambulance/field use choose the MAX190AEWG (extended temp). The SAR architecture provides instant-on sampling needed for real-time waveforms.

⚡

Battery-Powered Measurement

The MAX190ACWG's software-controlled power-down mode at just 60 µA enables low-duty-cycle battery-powered measurement applications. A microcontroller can power-up the ADC for a single conversion and immediately drop back to sleep, dramatically extending battery life in remote sensor nodes. The internal 4.096 V reference eliminates the standby current of an external reference. At 75 ksps the ADC samples faster than most sensor bandwidths, allowing oversampling for noise reduction. The wide-input voltage range supports direct battery-monitoring on lithium battery stacks up to 5V per cell.

推荐产品汇总

MAX1300ECM+ Higher-channel-count SAR ADC for PLC analog modules 用于: Industrial Process Control / PLC Analog Input Modules MAX197BCWI+ Multi-channel 12-bit ADC alternative for multi-input PLCs 用于: Industrial Process Control / PLC Analog Input Modules MAX174BCPA Companion 12-bit DAC for closed-loop process control output 用于: Industrial Process Control / PLC Analog Input Modules MAX147AEAP+TG05 Analog Devices 用于: Portable Data Loggers MAX1270ACNG Analog Devices 用于: Portable Data Loggers MAX12554ETL+ Higher-speed SAR ADC for high-resolution digitizers 用于: Pen Digitizers and Tablet Input MAX1156AEUI+ Multi-channel SAR ADC alternative 用于: Pen Digitizers and Tablet Input, Medical Monitoring Equipment MAX1302ECM+ Higher-channel SAR ADC for multi-channel instruments 用于: Test & Measurement Instrumentation MAX197ACWI+ Multi-channel ADC alternative 用于: Test & Measurement Instrumentation MAX1304ECM+ Higher-channel-count SAR ADC for multi-parameter monitors 用于: Medical Monitoring Equipment MAX147AEAP+ Lower-power SAR for ultra-low-power battery apps 用于: Battery-Powered Measurement MAX1275ACTC+T Maxim Integrated 用于: Battery-Powered Measurement
What is the resolution and sample rate of the MAX190ACWG?
The MAX190ACWG is a 12-bit resolution ADC that samples at up to 75 ksps (kilosamples per second). According to the Maxim datasheet, throughput is controlled by an external 2.5 MHz to 5 MHz clock, and each conversion requires approximately 100 ns of acquisition time, supporting the full 75 ksps rate on a single acquisition/conversion cycle.
What is the input voltage range of the MAX190ACWG?
The MAX190ACWG accepts analog inputs from 0 V to +5 V (unipolar) or ±5 V (bipolar), selectable via software input-range configuration. According to Maxim's datasheet, the bipolar mode is enabled by tying the BIPOLAR pin HIGH and the input is internally scaled to match the 4.096 V internal reference.
Is the MAX190ACWG still in production or recommended for new designs?
The MAX190ACWG is marked NRND (Not Recommended for New Designs) on the Analog Devices product page. The MAX1290 (serial-interface successor) and MAX191 (lower-power upgrade) are recommended replacements for new designs. Existing designs can continue sourcing the MAX190ACWG but should plan migration.
What is the difference between MAX190ACWG and MAX190BCWG?
The MAX190ACWG is the A-grade with ±0.5 LSB INL (max), while the MAX190BCWG is the B-grade with ±1 LSB INL (max). Both share the same SOIC-24 package, 75 ksps sample rate, and pinout; the B-grade is less expensive and acceptable where the lower linearity is tolerable.
What is the difference between MAX190ACWG and MAX190AEWG?
The MAX190ACWG operates over the commercial 0 °C to +70 °C range, while the MAX190AEWG operates over the extended −40 °C to +85 °C industrial range. Both share identical electrical specs and SOIC-24 pinout, making the AEWG a drop-in upgrade for harsher environments.
Where can I buy the MAX190ACWG online?
The MAX190ACWG is in stock at major distributors including DigiKey (466818), Mouser, Octopart, and FindIC. As of 2026-10-15, unit pricing starts around $24.52 at qty 1 with breaks at 10, 100, 500 and 1000 pieces. Lead time is typically 4-8 weeks from authorized stock.
What is the price of the MAX190ACWG in volume?
At qty 1, the MAX190ACWG lists around $24.52; this drops to approximately $19.45 at 100 pieces and $16.20 at 1000 pieces as of 2026-10-15 distributor data. Octopart aggregates pricing across 15 distributors so engineers can compare bulk discounts in real time.
What is the lead time for the MAX190ACWG?
Lead time for the MAX190ACWG is currently 4 to 8 weeks from authorized distributors as of 2026-10-15. Because the part is NRND, lead times may extend, and engineers should consider stocking for production or migrating to the MAX1290 (serial interface) or MAX191 (lower-power) recommended successors.
Is the MAX190ACWG in stock at distributors?
As of 2026-10-15 the MAX190ACWG shows limited stock at DigiKey and Mouser, with larger volumes available via Octopart's aggregated inventory across 15 distributors. Because the part is NRND, inventory fluctuates - engineers should verify stock at the time of order and consider the MAX190AEWG for extended temp coverage.
MAX190ACWG vs MAX191 - which is better for battery-powered designs?
The MAX191 is the recommended successor for battery-powered designs, drawing 1.5 mA active versus 3 mA on the MAX190ACWG and offering lower power-down current. The MAX191 also adds a serial interface. According to Maxim's product page, the MAX191 is the recommended replacement where the MAX190's higher power was a constraint.
When should I choose the MAX190ACWG over the MAX190BCWG?
Choose the MAX190ACWG when your application requires ±0.5 LSB INL (A-grade linearity) for precision measurement - data loggers, instrumentation, process control. Choose the MAX190BCWG for less-critical applications where ±1 LSB INL is acceptable and cost matters more than linearity, since both share the same SOIC-24 pinout.
Is the MAX190ACWG suitable for industrial process control applications?
The MAX190ACWG's ±0.5 LSB INL, internal 4.096 V reference, and 0-5V / ±5V input ranges make it well suited for industrial process control. However, the commercial 0°C to +70°C range is limited; for harsh industrial environments choose the MAX190AEWG (extended −40°C to +85°C) which is a drop-in upgrade.
What is the best drop-in replacement for the MAX190ACWG?
The best drop-in replacements are MAX190BCWG+ (B-grade, same SOIC-24 package, lower cost, ±1 LSB INL) and MAX190AEWG+ (extended temp grade, same SOIC-24 package, ±0.5 LSB INL). Both share the same pinout and can replace the MAX190ACWG without PCB changes - verify software-configured bipolar/unipolar mode matches.
Where to download the MAX190ACWG datasheet PDF?
The official MAX190ACWG datasheet can be downloaded from the Analog Devices product page at https://www.analog.com/en/products/max190.html. Third-party mirrors are also available on alldatasheet.com and FindIC; the manufacturer-hosted PDF on analog.com is the authoritative version and includes the full electrical tables.
Where to find the MAX190ACWG pinout?
The MAX190ACWG pinout is in the official Maxim datasheet (Rev 2) on the Analog Devices website. Pin assignments for the 24-pin SOIC (WG) package include AVDD, DVDD, GND, REF, REFADJ, BIPOLAR, CS, RD, WR, INT, CLK, HBEN, DOUT-DOUT11, AIN, and AGND/DGND pins arranged across both sides of the wide SOIC body.
What is the MAX190ACWG and what does it do?
The MAX190ACWG is a 12-bit, 75 ksps SAR (successive-approximation register) analog-to-digital converter with an internal 4.096 V reference and software-controlled power-down mode. According to Maxim's datasheet, it converts analog input voltages from 0 to +5 V (or ±5 V bipolar) into a 12-bit byte-wide parallel digital code for data acquisition systems, instrumentation, and process-control applications.
Can the MAX190BCWG+ replace the MAX190ACWG?
Yes, the MAX190BCWG+ can drop-in replace the MAX190ACWG. Both share the same SOIC-24 (WG) package and pinout. The only meaningful difference is INL: MAX190ACWG specifies ±0.5 LSB (max), MAX190BCWG specifies ±1 LSB (max). For applications tolerant of lower linearity, the B-grade is a direct functional replacement.

工程参考数据: MAX190ACWG ——对比、设计指导和合规信息。

选型指南

Choose the MAX190ACWG when you need a 12-bit, 75 ksps SAR ADC with ±0.5 LSB INL for commercial-temperature instrumentation, data loggers, or process-control designs and you want to keep a parallel interface. Choose the MAX190BCWG+ for lower-cost designs tolerant of ±1 LSB INL. Choose the MAX190AEWG+ for extended-temperature (industrial −40°C to +85°C) applications — same SOIC-24 footprint, drop-in upgrade. For new designs, Maxim recommends the MAX1290 (serial interface) or MAX191 (lower-power) successors; the MAX190 family is marked NRND. All five parts in the alternatives list share the SOIC-24 (WG) package footprint except the MAX190BCNG, which uses the DIP-24 (NG) through-hole package.

与替代料对比

参数 本产品 MAX190AEWG+ MAX190BCWG+ MAX190BEWG+ MAX190ACWG+ MAX190BCNG
Package 24-pin SOIC (WG) 24-pin SOIC (WG) - same 24-pin SOIC (WG) - same 24-pin SOIC (WG) - same 24-pin SOIC (WG) - same 24-pin DIP (NG) - through-hole
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Resolution 12 bits 12 bits 12 bits 12 bits 12 bits 12 bits
Sample Rate 75 ksps 75 ksps 75 ksps 75 ksps 75 ksps 75 ksps
INL (max) ±0.5 LSB (A-grade) ±0.5 LSB (A-grade) ±1 LSB (B-grade) ±1 LSB (B-grade) ±0.5 LSB (A-grade) ±1 LSB (B-grade)
Operating Temperature 0 °C to +70 °C −40 °C to +85 °C (extended) 0 °C to +70 °C −40 °C to +85 °C (extended) 0 °C to +70 °C 0 °C to +70 °C
Internal Reference 4.096 V 4.096 V 4.096 V 4.096 V 4.096 V 4.096 V
Power-Down Current 60 µA 60 µA 60 µA 60 µA 60 µA 60 µA
Active Supply Current 3 mA (typ) 3 mA (typ) 3 mA (typ) 3 mA (typ) 3 mA (typ) 3 mA (typ)

关键差异点

  • A-grade linearity ( ±0.5 LSB INL) (对比 MAX190BCWG+)
  • Commercial temperature grade pricing advantage (对比 MAX190AEWG+)
  • Integrated precision reference eliminates external components (对比 MAX1290 (successor))

设计说明

Power the MAX190ACWG from a clean +5V analog supply; add a 10 µF tantalum or ceramic + 0.1 µF ceramic bypass as close as possible to the AVDD pin (pin 6). The DVDD pin (pin 7) should be tied to the same +5V supply but bypassed separately to avoid digital switching noise coupling into the analog domain. Estimated: with 3 mA active current and 5V supply, the ADC dissipates approximately 15 mW — a negligible thermal load.

Use a separate analog ground plane and a separate digital ground plane on the PCB, joining them at a single point directly under the MAX190ACWG (the AGND/DGND pins). Route digital output lines (DOUT0-DOUT11) away from the analog input and REF pins to avoid coupling switching transients into the input signal path. Place the 10 µF supply bypass capacitor on the same layer as the IC to minimize via inductance.

Do not exceed the absolute maximum analog input voltage of ±15 V on AIN (pin 2) — over-voltage on the analog input can permanently damage the device. Tie the BIPOLAR pin (pin 21) HIGH for ±5V bipolar mode and LOW for 0-5V unipolar mode; software-controlled input range is not supported. The CLK pin (pin 22) requires an external 2.5-5 MHz clock — operation without a clock will halt conversion. Ensure HBEN (pin 24) is tied LOW for low-byte-first reads or HIGH for high-byte-first reads.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
无铅
Yes
无卤
Unknown
冲突矿物
Compliant

MAX190ACWG is lead-free and RoHS compliant per Maxim/Analog Devices product page. Not AEC-Q100 qualified — this is a commercial/industrial part, not an automotive-grade ADC. For automotive designs choose MAX190xEWG variants only after qualifying for the specific automotive environment.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MAX190ACWG MAX190ACWG datasheet MAX190ACWG price MAX190ACWG pinout MAX190ACWG replacement MAX190ACWG vs MAX190BCWG 12-bit 75 ksps SAR ADC SOIC-24 Analog Devices 12-bit ADC with internal reference MAX190ACWG industrial process control low power 12-bit ADC data logger what is the sample rate of MAX190ACWG MAX190ACWG SOIC-24 alternative MAX190ACWG distributor stock MAX190ACWG lead time MAX190AEWG vs MAX190ACWG

相关元器件 & 术语

Analog Devices Maxim Integrated MAX190ACWG MAX190AEWG MAX190BCWG MAX190BEWG MAX190BCNG MAX1290 MAX191 SAR ADC successive approximation register analog-to-digital converter data converter ADC/DAC byte-wide parallel interface internal 4.096 V reference bandgap reference 12-bit resolution 75 ksps sample rate ±0.5 LSB INL SOIC-24 (WG) wide-body SOIC surface mount RoHS compliant industrial process control data logger pen digitizer battery-powered measurement
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情