MAX3388EEUG+ - 2.5V ESD-Protected RS-232 | Maxim
料号: MAX3388EEUG+ ✓ 量产中MAX3388EEUG+ 概述
An RS-232 transceiver is a semiconductor interface device that converts logic-level signals into RS-232 line levels and converts incoming RS-232 signals back into CMOS-compatible logic. The MAX3388EEUG+ supports EIA/TIA-232 and V.28/V.24 communications interfaces. Its low 2.5V supply design is particularly useful for portable equipment, personal digital assistants, and cellular-phone systems where power consumption and circuit area are important constraints.
The three transmitter and two receiver arrangement gives the device a 3/2 channel configuration. Additional standout characteristics include ±15kV ESD protection and operation from a 2.5V supply. These features help protect the interface pins when cables are connected, removed, or exposed to electrostatic discharge during handling. The MAX3388E family is also identified as providing high data-rate capability and low power requirements.
The 24-TSSOP package provides a surface-mount implementation with gull-wing terminals and a rectangular body. The industrial temperature grade makes the MAX3388EEUG+ appropriate for equipment operating across an industrial environment. Its three transmitters also allow a single package to support multiple outgoing RS-232 lines, reducing the number of interface components required on a board.
Typical applications include handheld and portable communication equipment, personal digital assistants, cellular-phone accessories, point-of-sale terminals, diagnostic equipment, and embedded serial-port systems. The two receiver channels can support two incoming signals while the three transmitter channels serve outbound links or status and control lines.
Designers should place required charge-pump and interface capacitors according to the manufacturer application circuit, maintain the specified supply range, and provide direct protection and layout measures for exposed cable connectors. The 24-pin TSSOP footprint is also sensitive to assembly and soldering practices, so the recommended land pattern and reflow profile should be followed.
This page organizes the RS-232 channel configuration, supply voltage, ESD rating, package information, drop-in replacement analysis, comparison parameters, and practical interface-layout guidance into one engineering-focused resource for component selection and PCB design.
直接替换替代料: MAX3388EEUG+ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: MAX3388EEUG+ (相同外形与封装尺寸) ——差异在于 Interface Standard, Product Type.
MAX3388ECUG+
✅ 直接替换联系询价
查看数据手册 →MAX3388EEUG+ 规格参数
| Product Type | RS-232 transceiver |
| Transmitter Channels | 3 channels |
| Receiver Channels | 2 channels |
| 电源电压 | 2.5 V |
| ESD Protection | ±15 kV |
| Communication Standard | EIA/TIA-232 |
| Interface Standard | V.28/V.24 |
| Operating Temperature Grade | Industrial |
| Package Type | 24-pin TSSOP |
| Terminal Count | 24 terminals |
| 安装方式 | Surface mount |
| Terminal Form | Gull wing |
| Package Shape | Rectangular |
| Lead-Free Status | Lead-free |
MAX3388EEUG+ rectangular 引脚配置指南
MAX3388EEUG+(rectangular 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: MAX3388EEUG+.
请参阅 数据手册 以查看完整引脚配置。
典型应用
MAX3388EEUG+ 适用于 6 应用s: Personal Digital Assistant Serial Port, Cellular Phone Accessory Interface, Point-of-Sale Terminal, Portable Diagnostic Equipment, Embedded Serial Communication System, Communication and Control Interface.
Personal Digital Assistant Serial Port
The MAX3388EEUG+ fits a compact personal digital assistant that needs several outbound RS-232 signals and two inbound signals. Its three transmitters and two receivers provide a 3/2 channel arrangement without requiring separate driver and receiver packages. The 2.5V operating supply aligns with the low-voltage design direction used in portable equipment, while ±15kV ESD protection adds interface ruggedness for a frequently handled cable connection. Place the transceiver near the connector-side protection and follow the manufacturer application circuit for the charge-pump components.
Cellular Phone Accessory Interface
The MAX3388EEUG+ is suitable for cellular-phone accessories requiring a low-voltage RS-232 communications path. Its 2.5V supply supports compact portable architectures, and the three transmitters can carry multiple outbound control or data signals while two receivers handle incoming communications or status information. The ±15kV ESD rating is valuable in cable-connected accessories where electrostatic discharge can occur during connection. Maintain short protected routes between the transceiver and connector and validate the external connector's own discharge requirements.
Point-of-Sale Terminal
The MAX3388EEUG+ can support a point-of-sale terminal that communicates with peripheral equipment through multiple RS-232 ports. Three transmitter channels permit outbound command and control lines, while two receiver channels accept responses from peripherals, reducing component count compared with separate interface packages. The 24-pin TSSOP keeps the implementation surface-mount and compact. For countertop equipment exposed to user-handled cables, retain the transceiver's ±15kV ESD capability and use the manufacturer-recommended capacitor placement for reliable charge-pump operation.
Portable Diagnostic Equipment
The MAX3388EEUG+ is appropriate for portable diagnostic equipment that needs a flexible mix of outgoing and incoming RS-232 links. The asymmetric 3/2 configuration lets an instrument send commands or data on three channels and receive information on two, while operating from a 2.5V supply. Its industrial temperature designation supports industrial-oriented equipment, although the complete environmental requirements must still be checked. The ±15kV ESD protection helps reduce susceptibility to transients encountered when connecting diagnostic leads or service cables.
Embedded Serial Communication System
The MAX3388EEUG+ fits embedded systems requiring legacy RS-232 connectivity alongside modern low-voltage logic. Three drivers can support command, status, and alarm outputs, while two receivers can collect asynchronous responses from another subsystem. Its EIA/TIA-232 and V.28/V.24 support makes it appropriate for conventional point-to-point serial interfaces. The surface-mount 24-TSSOP package simplifies board integration, but the layout should preserve short interface routes and the manufacturer-specified charge-pump capacitor arrangement.
Communication and Control Interface
The MAX3388EEUG+ can divide an RS-232 interface into three communication or control outputs and two inputs within one package. This is useful when a controller must issue several commands while monitoring two return channels, and it can reduce board area compared with separate one-channel devices. The 2.5V supply supports low-voltage systems, while ±15kV ESD protection strengthens cable-facing circuitry. Validate logic levels, shutdown behavior, and grounding against the complete Maxim Integrated datasheet before finalizing a multi-drop or long-cable system.
工程参考数据: MAX3388EEUG+ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | MAX3388ECUG+ |
|---|---|---|
| Package | 24-pin TSSOP | 24-pin TSSOP |
| Brand | Maxim Integrated | Maxim Integrated |
| Product Type | RS-232 transceiver | RS-232 interface transceiver |
| Transmitter Channels | 3 channels | 3 channels |
| Receiver Channels | 2 channels | 2 channels |
| Supply Voltage | 2.5 V | 2.5 V |
| ESD Protection | ±15 kV | ±15 kV |
| Communication Standard | EIA/TIA-232 and V.28/V.24 | RS-232 |
| Mounting Style | Surface mount | Surface mount |
| Lead-Free Status | Lead-free | Lead-free |
关键差异点
- Three transmitters provide more outbound channels than receivers (对比 MAX3388ECUG+)
- Package-compatible replacement path (对比 MAX3388ECUG+)
- Low-voltage portable-device positioning (对比 MAX3388ECUG+)
设计说明
Place the MAX3388EEUG+ between the RS-232 connector and the system logic, keeping each protected line as short and direct as practical. Follow the Maxim Integrated application circuit for charge-pump capacitor placement, and avoid routing connector-facing traces beneath noisy digital or switching-power nodes. Confirm all 24 pin assignments against the manufacturer pin-description table before releasing the layout.
RS-232 driver outputs are intentionally high-voltage, bipolar signals and should not be routed alongside sensitive analog or low-level clock inputs. Keep ground returns associated with each cable-facing interface continuous and evaluate the system grounding strategy with the ESD and connector circuitry in place. The MAX3388EEUG+ includes ±15kV ESD protection, but proper layout and external connector protection remain necessary parts of a complete interface solution.
The MAX3388EEUG+ operates from a 2.5V supply, so the bypass network and charge-pump components must follow the manufacturer reference design. Decouple the supply close to the device with low-inductance routing, verify capacitor voltage ratings and tolerances, and avoid long shared supply paths between the transceiver and fast-switching circuitry. Confirm startup and shutdown sequencing against the logic requirements of the connected system.
Do not treat a package-compatible replacement as automatically equivalent without checking its complete orderable suffix. MAX3388EEUG+ is identified as an industrial-temperature-grade 24-pin TSSOP part, while the alternative is documented as a complete replacement but uses a different suffix. Confirm the ordering code, temperature range, supply limits, and lifecycle status in the Maxim Integrated documentation before substituting it in production.
合规信息
The product is identified as lead-free. RoHS, REACH, AEC-Q100, halogen-free, and conflict-minerals declarations were not explicitly established by the available manufacturer product listing.