MCP3464RT-E/NC - 16-Bit 153.6kSPS ADC | Microchip Technology
料号: MCP3464RT-E/NC ✓ 量产中MCP3464RT-E/NC 概述
A delta-sigma ADC is an analog-to-digital converter category that uses oversampling, digital filtering, and noise shaping to achieve high resolution in low-bandwidth measurement systems. The MCP3464 belongs to the ADC > data converter > mixed-signal IC hierarchy, where its role is to convert accurately measured analog voltages into digital data for processing by a microcontroller, embedded controller, or industrial control system.
The principal features include 16-bit resolution, a selectable maximum conversion rate of 153.6 kSPS, four differential or eight single-ended input channels, and an integrated voltage reference. The converter supports analog inputs from 2.7 V to 3.6 V and digital interfaces from 1.8 V to 3.7 V. Its operating temperature range extends from -40 C to +125 C, supporting industrial and temperature-sensitive measurement designs.
The delta-sigma architecture is particularly suitable for precision acquisition rather than high-frequency waveform capture. Conversion latency, digital filter settling, and the selected output data rate determine how quickly a new result becomes available. The integrated reference and low-noise design reduce the number of external precision components required, while the serial interface supports compact embedded systems in which board area is constrained.
Typical uses include industrial process monitoring, sensor-interface modules, portable measurement instruments, environmental data acquisition, medical instrumentation, and embedded condition-monitoring systems. Multiple analog inputs allow one converter to service several transducers, while differential operation can help reject common-mode noise when appropriately paired with sensor and reference arrangements.
The exposed-pad package requires careful PCB layout for thermal and electrical performance. Place the required bypass capacitors close to their associated supply pins, connect the exposed pad to the appropriate ground plane, and route high-impedance inputs away from switching nodes and digital return currents. Follow the manufacturer datasheet for the exact pin assignments, recommended network, and exposed-pad land pattern.
This product page combines the manufacturer’s device characteristics, verified distributor availability information, package details, application guidance, and qualified family alternatives. It also highlights the important engineering distinctions among the MCP3464 variants so designers can select a pin-compatible option without confusing package, reference, or temperature-code differences.
直接替换替代料: MCP3464RT-E/NC ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: MCP3464RT-E/NC (相同外形与封装尺寸) ——差异在于 Converter Architecture, Internal Oscillator, Internal Voltage Reference, Package.
MCP3464RT-E/ST
✅ 直接替换📋 参考替代料(不在目录中)
MCP3464RT-E/NC 最大额定值与电气特性
| 分辨率 | 16 bit |
| Maximum Conversion Rate | 153.6 kSPS |
| Input Configuration | 8 single-ended or 4 differential inputs |
| Input Type | Single-ended or differential |
| Converter Architecture | Delta-sigma |
| Internal Voltage Reference | Yes |
| Internal Oscillator | Yes |
| 内部温度传感器 | Yes |
| Analog Supply Voltage Range | 2.7 V to 3.6 V |
| Digital Supply Voltage Range | 1.8 V to 3.7 V |
| 工作温度范围 | -40 C to +125 C |
| 封装 | 20-pin UQFN with exposed pad, 3 x 3 mm |
| Surface-Mount Package Type | UQFN-20 |
| 引脚数 | 20 pins |
| Output Data Format | 16-bit serial data |
| 安装类型 | Surface mount |
| Shipping Package | Tape and reel |
MCP3464RT-E/NC tape and reel 引脚配置指南
MCP3464RT-E/NC(tape and reel 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: MCP3464RT-E/NC.
请参阅 数据手册 以查看完整引脚配置。
典型应用
MCP3464RT-E/NC 适用于 6 应用s: Industrial Process Monitoring, Portable Environmental Sensors, Medical Measurement Instruments, Condition Monitoring Systems, Data Acquisition Modules, Battery-Powered Embedded Measurement.
Industrial Process Monitoring
The MCP3464RT-E/NC fits industrial process monitoring where several slowly changing sensor signals must be digitized with high resolution. Its eight single-ended or four differential input configuration allows pressure, temperature, level, and current-sense channels to share one converter, while 16-bit resolution and a maximum rate of 153.6 kSPS provide useful measurement headroom. Differential inputs are especially valuable when sensor wiring is exposed to common-mode industrial noise. Place the converter close to the analog inputs, use shielded or carefully routed sensor traces, and follow the manufacturer datasheet for bypass capacitance and input filtering. The -40 C to +125 C operating range also supports equipment intended for harsh ambient conditions.
推荐
Portable Environmental Sensors
The MCP3464RT-E/NC is useful in compact environmental sensor nodes that measure temperature, humidity, gas, pressure, or light levels with low-bandwidth analog front ends. Its 3 x 3 mm UQFN exposed-pad package preserves PCB area, and the internal voltage reference, oscillator, and temperature sensor can simplify the supporting circuitry. The 153.6 kSPS maximum rate supports programmable filtering and averaging while favoring low-bandwidth measurements over waveform capture. Because portable systems share grounds with radios, displays, and actuators, route analog inputs away from switching currents and use the manufacturer’s recommended supply and reference layout to preserve conversion accuracy.
推荐
Medical Measurement Instruments
The MCP3464RT-E/NC can support precision front ends in medical and laboratory instruments when the signal bandwidth is appropriately low for a delta-sigma converter. The 16-bit resolution and four differential inputs suit multiple biopotential, pressure, or sensor-conditioning channels, while the internal reference helps reduce external component count. Differential pairing should be used to control common-mode noise, and analog isolation requirements must be addressed separately from the ADC itself. The 3 x 3 mm package supports compact instrument designs, but exposed-pad construction demands correct thermal-pad assembly and careful separation between analog input routing and digital clock lines.
推荐
Condition Monitoring Systems
The MCP3464RT-E/NC is appropriate for vibration, motor-current, and asset-condition monitoring systems that sample low-frequency or narrow-band sensor data. Its four differential inputs can monitor multiple sensing axes or channels with common-mode rejection, while 153.6 kSPS allows configurable digital filtering and averaging. The 16-bit format preserves low-level measurement detail, but the design must account for delta-sigma filter settling and aliasing rather than treating the maximum sample rate as a streaming waveform rate. Use separate analog and digital supply routing, quiet reference connections, and short sensor traces to prevent motor switching noise from degrading the conversion result.
推荐
Data Acquisition Modules
The MCP3464RT-E/NC works well in compact standalone data-acquisition modules that must present accurate, serial conversion data to a host controller or embedded processor. Eight single-ended inputs allow one module to monitor several analog channels, while the exposed-pad UQFN package maximizes usable board area. The internal reference and oscillator reduce external dependencies, and the 1.8 V to 3.7 V digital supply range provides flexibility in mixed-voltage systems. Designers should verify the supported serial protocol and conversion timing in the manufacturer datasheet, then reserve routing space for the exposed pad and place input and bypass networks directly beside their associated pins.
推荐
Battery-Powered Embedded Measurement
The MCP3464RT-E/NC can serve battery-powered embedded systems that repeatedly measure low-bandwidth analog quantities rather than continuously stream high-rate samples. Its low-noise delta-sigma architecture and programmable rate up to 153.6 kSPS allow the system to select an appropriate conversion speed and filter bandwidth for the duty cycle. The 2.7 V to 3.6 V analog supply and 1.8 V to 3.7 V digital supply support low-voltage system partitioning. Power budgeting should include the converter, external sensors, and digital interface activity, while the exposed pad should be connected to the recommended ground construction to preserve thermal performance during repeated conversion bursts.
推荐
推荐产品汇总
工程参考数据: MCP3464RT-E/NC ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | MCP3464RT-E/ST |
|---|---|---|
| Brand | Microchip Technology | Microchip Technology |
| Package | 20-pin UQFN with exposed pad, 3 x 3 mm | 20-pin UQFN with exposed pad |
| Resolution | 16 bit | 16 bit |
| Maximum Conversion Rate | 153.6 kSPS | 153.6 kSPS |
| Differential Input Channels | 4 inputs | 4 inputs |
| Converter Architecture | Delta-sigma | Delta-sigma |
| Analog Supply Voltage | 2.7 V to 3.6 V | 2.7 V to 3.6 V |
| Digital Supply Voltage | 1.8 V to 3.7 V | 1.8 V to 3.7 V |
| Operating Temperature | -40 C to +125 C | -40 C to +125 C |
| Internal Voltage Reference | Yes | Yes |
| Internal Oscillator | Yes | Yes |
关键差异点
- Four-channel differential acquisition in a compact exposed-pad package (对比 MCP3464RT-E/ST)
- Integrated measurement support reduces external circuitry (对比 MCP3464RT-E/ST)
- Broad industrial temperature range (对比 MCP3464RT-E/ST)
设计说明
Treat the exposed pad as both a thermal connection and a mandatory land-pattern feature. Follow the manufacturer datasheet for the exposed-pad dimensions, solder-mask opening, and paste volume, then connect the pad to the recommended ground-plane construction. Place input, reference, and bypass components close to their associated pins; excessive trace length between the capacitor and supply pin adds supply impedance that can degrade converter performance.
Keep the eight analog inputs away from the serial clock, data lines, switching regulators, and high-current return paths. Differential pairs should be routed consistently with continuous reference grounding and without intervening layer changes where practical. Because the MCP3464RT-E/NC supports four differential channels, preserving channel symmetry helps prevent common-mode conversion and timing differences from appearing as measurement errors.
Do not treat the 153.6 kSPS maximum conversion rate as a zero-latency real-time sampling rate. Delta-sigma outputs pass through a digital filter, so the selected data rate and filter configuration determine settling time and usable bandwidth. Confirm output-data timing, serial interface mode, and channel sequencing in the manufacturer datasheet before designing a control loop that assumes immediate conversion results.
Use separate, well-decoupled analog and digital supply paths and observe the specified 2.7 V to 3.6 V analog and 1.8 V to 3.7 V digital limits. Place the required bypass capacitors at the pins, provide a low-impedance return for digital interface current, and avoid routing clock edges beneath sensitive analog inputs. If an external reference is permitted, validate its accuracy and noise against the accuracy budget for the complete measurement chain.
合规信息
The manufacturer product page identifies the MCP3464 family as active, but no specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations are included in the available device information. Confirm these compliance statements for the exact orderable MPN and current package documentation before environmental or automotive qualification.