Microchip Technology

MCP3909ISS - 16-Bit Energy Metering AFE | Microchip

料号: MCP3909ISS ✓ 量产中
有现货 1-3 个工作日内发货
4.5 V to 5.5 V Vdss 2.3 mA Id IEC 1036, IEC 61036, and IEC 687 Rds(on) 24-SSOP, 0.209 inch / 5.30 mm width Package
联系我们 询价
最小起订量: 1 |
价格更新于: 2026-10-20
批量定价
数量 单价 小计
1 $3.1385 $3.14
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ 所有价格均以 USD 计价

MCP3909ISS 概述

The Microchip Technology MCP3909ISS is a 16-bit energy-metering analog front-end IC with SPI interface, active-power pulse output, and single-phase metering support. The verified product data identifies a 4.5 V to 5.5 V supply range, 2.3 mA supply current, 390 kOhm input impedance, and 0.1% measurement error. It is supplied in a 24-SSOP package, making it suitable for compact single-phase energy-metering designs.

An energy-metering AFE is a signal-chain IC that measures voltage and current channels and converts their analog inputs into digital information for energy calculation. In the broader hierarchy, an energy-metering IC belongs to the AFE and power-measurement semiconductor category, where accurate current and voltage acquisition supports utility meters, load monitoring, industrial energy management, and building-energy systems. The MCP3909 is designed around the IEC 62053 international metering specification and also references legacy IEC 1036, IEC 61036, and IEC 687 requirements in the verified data.

The MCP3909 combines simultaneous serial access to ADC channels with multiplier output data and a frequency output proportional to average active real power. These features allow a host processor to retrieve measurements while the hardware provides a convenient active-power pulse indication. The 16-bit ADC architecture is intended for metering applications where measurement resolution and energy accuracy are more important than low-cost general-purpose signal acquisition.

Typical uses include single-phase utility meters, residential energy monitors, industrial submeters, appliance energy measurement, and embedded power-monitoring equipment. In these systems, the AFE accepts voltage and current information, performs analog-to-digital conversion, and supplies measurement data through its serial interface. The active-power output can provide a low-frequency measurement signal for meter calibration, energy accumulation, or system monitoring.

The principal design considerations are input filtering, calibration, reference stability, signal integrity, and correct implementation of the current and voltage channels. Designers should follow the manufacturer datasheet for the exact pin functions, recommended external components, analog input limits, digital interface timing, and calibration procedure. The verified web data confirms the 24-SSOP package and tube packaging information, while some detailed electrical limits and pin-level details require datasheet confirmation.

This page combines verified manufacturer and distributor information with application guidance and design considerations. It also identifies the MCP3909 as a single-phase 24-SSOP energy-metering IC with SPI connectivity, active-power pulse output, a 16-bit ADC, and support for IEC 62053-oriented metering designs.

直接替换替代料: MCP3909ISS ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

MCP3909T-I/SS

✅ 直接替换
📦 24-SSOP
Verified web comparison lists the same MCP3909 family and 24-SSOP form, but the supplied data does not quantify suffix-specific electrical or pin differences; treat equivalence as requiring manufacturer confirmation.

📋 参考替代料(不在目录中)

MCP3909ISS 最大额定值与电气特性

Product Type Single-phase energy-metering AFE IC
ADC Resolution 16 bit
Supply Voltage Range 4.5 V to 5.5 V
电源电流 2.3 mA
Input Impedance 390 kOhm
Measurement Error 0.1%
接口 SPI
Active Power Output Frequency output proportional to average active real power
Measurement Channels Voltage and current measurement channels
Metering Standard IEC 62053 international energy metering specification
Legacy Standards Referenced IEC 1036, IEC 61036, and IEC 687
封装 24-SSOP, 0.209 inch / 5.30 mm width
Packaging Tube
安装类型 Surface mount
Application Single-phase energy metering
Digital Data Access Simultaneous serial access to ADC channels and multiplier output data

MCP3909ISS 24-ssop, 0.209 inch / 5.30 mm width 引脚配置指南

MCP3909ISS(24-ssop, 0.209 inch / 5.30 mm width 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

MCP3909ISS 的 24-ssop, 0.209 inch / 5.30 mm width 封装引脚图

暂无详细引脚数据: MCP3909ISS.

请参阅 数据手册 以查看完整引脚配置。

典型应用

MCP3909ISS 适用于 6 应用s: Single-Phase Residential Utility Meter, Industrial Submetering, Residential Energy Monitor, Appliance Energy Measurement, Building Energy Management, Power-Quality Monitoring Front End.

💡

Single-Phase Residential Utility Meter

The MCP3909ISS fits a residential meter because it combines a 16-bit energy-metering ADC with voltage and current measurement channels, SPI access, and an active-power frequency output. A host controller can read converted channel data and accumulate energy while the frequency output provides a measurement signal for system monitoring. The verified 4.5 V to 5.5 V supply range and 0.1% stated measurement error are suitable starting points for accurate single-phase metering. Final accuracy depends on current and voltage sensors, analog filtering, calibration, reference stability, and compliance testing.

🏭

Industrial Submetering

Use the MCP3909ISS as the measurement front end in an industrial submeter when the equipment must acquire voltage and current information for energy accounting. Its 16-bit ADC and simultaneous serial access to ADC channels support synchronized digital readings, while the active-power pulse output offers a hardware indication of average active real power. The 390 kOhm input impedance is a verified parameter that must be considered with the sensor network and filtering choices. Designers should verify industrial temperature, EMC, isolation, and regulatory requirements separately.

📱

Residential Energy Monitor

The MCP3909ISS can serve as the metering AFE in a residential energy monitor that reports load consumption to a display, gateway, or communications module. The SPI interface allows a host processor to retrieve ADC channel information and multiplier output data, while the frequency output proportional to average active real power can assist with energy accumulation or calibration workflows. The 2.3 mA supply current is useful for low-power meter electronics, but the complete system budget includes sensors, host MCU, communications, and regulators.

🔧

Appliance Energy Measurement

For appliance energy measurement, the MCP3909ISS can acquire the voltage and current channels required by an embedded energy-calculation system. Its 16-bit conversion resolution and 0.1% stated measurement error are relevant when the appliance load varies across a broad operating range. The active-power frequency output provides a convenient signal for an energy accumulator or measurement verification path. Engineers should optimize the current-sensor input network, maintain low-noise analog routing, and calibrate across expected voltage, current, and temperature conditions.

🧩

Building Energy Management

The MCP3909ISS is appropriate for a building energy-management node that measures one load or branch circuit and reports consumption to a building controller. Simultaneous serial access to ADC channels allows the controller to coordinate voltage and current readings, while the active-power output can provide a convenient power-proportional indication. The 4.5 V to 5.5 V supply range simplifies integration with regulated 5 V meter electronics. In deployed products, validate the complete signal chain for line transients, temperature drift, EMC, safety isolation, and applicable metering standards.

⚡

Power-Quality Monitoring Front End

The MCP3909ISS can form part of a power-monitoring front end when the system needs simultaneous voltage and current acquisition for energy or load analysis. The SPI interface supports integration with a digital controller, and the active-power frequency output can be used as a reference measurement channel for system-level algorithms. The device is an energy-metering AFE rather than a complete power-quality analyzer, so harmonic, transient, and waveform requirements need separate verification. Preserve analog signal integrity and follow the manufacturer input-conditioning recommendations.

推荐产品汇总

MCP3909T-I/SS Related Microchip MCP3909 family listing 用于: Single-Phase Residential Utility Meter, Industrial Submetering, Residential Energy Monitor, Appliance Energy Measurement, Building Energy Management, Power-Quality Monitoring Front End
What is the MCP3909ISS used for?
The MCP3909ISS is a single-phase energy-metering analog front-end IC used to measure voltage and current signals for energy-metering equipment. According to the Microchip product page, it supports the IEC 62053 international energy-metering specification and provides serial ADC access plus an active-power frequency output. It is suitable for utility meters, residential monitors, and industrial energy-measurement systems.
What are the key specifications of MCP3909ISS?
The MCP3909ISS is a 16-bit energy-metering AFE with a 4.5 V to 5.5 V supply range, 2.3 mA supply current, 390 kOhm input impedance, and 0.1% measurement error. The verified product data also identifies an SPI interface, active-power pulse output, simultaneous serial access to ADC channels, and a 24-SSOP package. These specifications make it suitable for accurate single-phase metering designs.
What is the operating voltage of MCP3909ISS?
The MCP3909ISS operates from 4.5 V to 5.5 V according to the verified datasheet specifications. The 2.3 mA supply-current value indicates a relatively low-power metering signal-chain device, although the complete application power budget also depends on external sensors, regulators, and host circuitry. Use a supply design that remains within this stated voltage range across temperature and tolerance conditions.
Where to download the MCP3909ISS datasheet PDF?
The official MCP3909 datasheet and product resources are available through Microchip's MCP3909 product page at https://www.microchip.com/en-us/product/MCP3909. The verified distributor references also identify MCP3909-I/SS documentation, while the requested MCP3909ISS ordering code uses the same core device family. Download the manufacturer datasheet for the authoritative pinout, electrical limits, timing, calibration, and application information.
Where can I find the MCP3909ISS pinout?
The MCP3909ISS pinout should be taken from the manufacturer datasheet for the MCP3909 family because the verified data confirms a 24-SSOP package but does not provide the complete pin-number table. The device includes power, ground, analog measurement, SPI, and active-power-output functions. Do not infer pin assignments from distributor search snippets; verify the exact package drawing before PCB release.
Does MCP3909ISS include an SPI interface?
Yes. The MCP3909ISS includes an SPI interface for serial access to ADC channels and multiplier output data. The verified distributor and manufacturer descriptions specifically identify SPI connectivity and simultaneous serial access. SPI clock rate, mode, chip-select behavior, and data-register details should be checked in the official datasheet before firmware is finalized.
What is the measurement error of MCP3909ISS?
The verified specification states a measurement error of 0.1% for the MCP3909ISS. This figure is appropriate for energy-metering signal acquisition when used with the application circuit and calibration process specified by Microchip. Actual end-product accuracy also depends on current and voltage sensor quality, analog filtering, reference accuracy, layout, and calibration.
Where can I buy MCP3909ISS online and what does it cost?
The MCP3909ISS can be purchased from electronics distributors including DigiKey, Mouser, and LCSC. The verified LCSC result lists a starting price of $3.1385, while DigiKey and Mouser provide product, inventory, and ordering information. Prices and stock change by quantity, region, and supplier, so verify the current quote as of 2026-10-21 before placing an order.
Is MCP3909ISS in stock?
The verified LCSC result identifies MCP3909-I/SS as in stock and gives a starting price of $3.1385, but the exact inventory for the MCP3909ISS ordering code is not specified in the supplied data. DigiKey and Mouser pages provide availability information for the related MCP3909-I/SS listing. Confirm the exact suffix, quantity, and current stock status with the distributor before procurement.
What is the lead time for MCP3909ISS?
The supplied distributor data does not state a guaranteed lead time for MCP3909ISS. Availability must therefore be confirmed directly with DigiKey, Mouser, LCSC, or Microchip for the exact ordering code and requested quantity. Do not treat a distributor listing or historical inventory indication as a committed delivery date; request a written quotation and current stock confirmation.
MCP3909ISS vs MCP3909T-I/SS: which part is the same?
The verified comparison result identifies MCP3909-I/SS and MCP3909T-I/SS as related Microchip listings, but it does not establish that the requested MCP3909ISS is an exact drop-in replacement for either device. Verify the full ordering suffix, package, temperature grade, and pin functions in Microchip documentation. Similar energy-metering functionality does not automatically guarantee pin-to-pin or specification compatibility.
When should I choose MCP3909ISS for a single-phase meter?
Choose MCP3909ISS when the design requires a dedicated single-phase energy-metering AFE with a 16-bit ADC, SPI data access, and active-power frequency output. The verified 4.5 V to 5.5 V supply range, 390 kOhm input impedance, and 0.1% stated measurement error support metering signal-chain designs. Confirm the exact pinout, sensor interface, calibration method, and environmental requirements before production.
Is MCP3909ISS suitable for industrial energy monitoring?
MCP3909ISS can be suitable for industrial energy-monitoring equipment when its 4.5 V to 5.5 V supply, analog inputs, SPI interface, and measurement accuracy match the system requirements. It is specifically identified as a single-phase metering IC supporting IEC 62053-oriented designs. Industrial products should additionally verify temperature limits, isolation requirements, regulatory targets, EMC behavior, and long-term calibration stability.
What can replace MCP3909ISS?
A replacement for MCP3909ISS must use the same package footprint and provide compatible power, analog-input, SPI, and active-power-output functions. The supplied cross-reference search found generic lookup tools but no verified Microchip or cross-brand MPN that is confirmed pin-to-pin compatible. Therefore, no drop-in replacement is asserted here; use the manufacturer cross-reference tool and compare the complete datasheets before substituting any part.
What is the best Microchip equivalent for MCP3909ISS?
The verified data does not identify a Microchip MPN that can be confirmed as a drop-in equivalent for MCP3909ISS. MCP3909T-I/SS appears in a comparison result, but that listing alone does not prove package, pin, or electrical equivalence. Ask Microchip's competitor cross-reference tool or an authorized distributor to compare the exact suffix and obtain a validated replacement recommendation.

工程参考数据: MCP3909ISS ——对比、设计指导和合规信息。

选型指南

Choose MCP3909ISS for a new single-phase metering design when the system needs a dedicated 16-bit energy-metering AFE, SPI connectivity, and active-power frequency output. Its verified 4.5 V to 5.5 V supply range, 390 kOhm input impedance, and 0.1% stated measurement error are useful starting points for analog-front-end design. The MCP3909T-I/SS appears in the supplied comparison data, but it should be selected only after Microchip confirms that its package, pinout, electrical limits, and suffix-specific functions match the target board. Do not use a generic energy-metering IC as a drop-in substitute unless the manufacturer explicitly confirms pin compatibility and parameter equivalence.

与替代料对比

参数 本产品 MCP3909T-I/SS
Brand Microchip Technology Microchip Technology
Package 24-SSOP 24-SSOP
Product Type Single-phase energy-metering AFE IC Related MCP3909 energy-metering IC listing
Interface SPI Related MCP3909 family listing; exact interface verification required

关键差异点

  • Dedicated single-phase metering function (对比 MCP3909T-I/SS)
  • 16-bit measurement resolution (对比 MCP3909T-I/SS)
  • Integrated active-power indication (对比 MCP3909T-I/SS)
  • SPI-connected measurement data (对比 MCP3909T-I/SS)

设计说明

Keep the MCP3909ISS analog voltage and current inputs short, shielded from switching nodes, and surrounded by a quiet ground return. The verified 390 kOhm input impedance should be included in the complete source-impedance and filter design. Place input-network components close to the device and follow the manufacturer datasheet for component values, grounding, and maximum input conditions.

Separate the SPI and digital-control traces from sensitive analog inputs, especially when the meter also contains switching power supplies or communication transceivers. Use a compact analog section with continuous ground-plane reference, minimize loop area around sensor and filtering networks, and provide decoupling close to the 4.5 V to 5.5 V supply pins. Confirm the final layout against the official MCP3909 recommended application circuit.

Do not assume that a similar MCP3909 ordering suffix is a drop-in replacement without checking the complete Microchip datasheet. Verify package pin numbering, temperature grade, calibration settings, register behavior, SPI timing, and electrical limits. The verified data supports the MCP3909 family's energy-metering function but does not provide a complete pinout or suffix-to-suffix equivalence matrix.

The verified supply-current value is 2.3 mA, but the complete power budget must also include the regulator, sensors, host controller, communications, and output circuitry. Use a regulated 5 V source within the stated 4.5 V to 5.5 V range and account for startup, transient, and tolerance requirements. Estimate rail dissipation only from measured or specified loads and verify it against the final supply design.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The verified data identifies support for the IEC 62053 international energy metering specification and references legacy IEC 1036, IEC 61036, and IEC 687. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-mineral status were not provided and therefore remain unknown.

数据核验日期: 2026-10-21 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MCP3909ISS MCP3909ISS datasheet Microchip MCP3909ISS 16-bit energy metering AFE MCP3909ISS 4.5 V 5.5 V 24-SSOP energy metering IC MCP3909ISS SPI interface single phase energy meter IC MCP3909ISS active power output MCP3909ISS vs MCP3909T-I/SS MCP3909ISS buy price MCP3909ISS stock MCP3909ISS pinout MCP3909ISS IEC 62053 MCP3909ISS replacement

相关元器件 & 术语

Microchip Technology MCP3909ISS MCP3909 MCP3909T-I/SS Single-phase energy-metering IC Energy-metering AFE Analog front end 16-bit ADC SPI Active-power frequency output Voltage measurement channel Current measurement channel IEC 62053 IEC 1036 IEC 61036 IEC 687 24-SSOP Surface-mount package Residential utility meter Industrial submetering Building energy management Power-monitoring front end Measurement error Input impedance
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情