MPVZ5010G7U 概述

The NXP MPVZ5010G7U is an integrated silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, delivering an analog output of 0.2 V to 4.7 V proportional to a 0 kPa to 10 kPa (1.45 PSI) vented gauge pressure range, housed in an 8-pin DIP through-hole module.

What is a board-mount pressure sensor? A board-mount pressure sensor (also called a board-mount pressure transducer) is a self-contained module that converts an applied pressure into an electrical signal using a micromachined silicon diaphragm and on-chip signal conditioning. Pressure sensors sit within the broader sensor hierarchy as: pressure sensor -> force/pressure transducer -> board-mount sensor -> MEMS device -> semiconductor component. The "vented gauge" configuration means the sensor references atmospheric pressure on one side via an integrated vent tube, so the output reflects differential pressure relative to ambient.

Key features include a supply voltage range of 4.75 V to 5.25 V (5 V typical), a calibrated analog output spanning 0.2 V at 0 kPa to 4.7 V at 10 kPa, ±1.5 %FS accuracy over 0 °C to 85 °C, and integral temperature compensation that eliminates the need for external calibration. The device also provides EMC hardening, RFI protection, and a rugged epoxy package rated for -10 °C to +60 °C compensation with 0 °C to 85 °C operating range.

The MPVZ5010G7U combines advanced micromachining, thin-film metallization, and bipolar semiconductor processing to provide an accurate, ratiometric analog output signal proportional to the applied pressure. Because the output scales with supply voltage (Vout/Vcc ratio), straightforward ADC conversion is achieved with any microcontroller featuring a 5 V-tolerant A/D input.

Typical applications include HVAC variable-air-volume (VAV) control, building/Room pressure monitoring, weather station pressure sensing, medical respiratory equipment (CPAP, ventilators), and industrial process control.

When designing with this device, ensure that the high-impedance ADC input of the host microcontroller does not load the sensor output and that adequate decoupling is placed near Vcc. The vent tube must remain free of obstruction for accurate gauge readings.

This page synthesizes distributor pricing, drop-in alternative cross-reference data, and practical design notes not consolidated in the manufacturer datasheet.

直接替换替代料: MPVZ5010G7U ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPVZ5010G7U (相同外形与封装尺寸) ——差异在于 Output Type, Operating Pressure Range, Supply Voltage, Package, Accuracy.

NXP Semiconductors
Output Type: Analog, ratiometric voltage
Operating Pressure Range: 0 kPa to 3.92 kPa
Supply Voltage: 2.7 V to 3.3 V (3 V typical)
对比 MPVZ5010G7U →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Supply Voltage: 2.7 V to 3.3 V (3 V nominal)
Package: SOP-8 (Case 1368-01), 8-SMD Module
对比 MPVZ5010G7U →
STMicroelectronics
Output Type: Analog Voltage (ratiometric)
Operating Pressure Range: 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
对比 MPVZ5010G7U →
NXP Semiconductors
Output Type: Analog Voltage, Ratiometric
Operating Pressure Range: 0 kPa to 10 kPa (1.45 PSI)
Supply Voltage: 4.75 V to 5.25 V
对比 MPVZ5010G7U →
STMicroelectronics
Output Type: Analog ratiometric
Operating Pressure Range: 0 kPa to 6 kPa
Supply Voltage: 5 V (typ)
对比 MPVZ5010G7U →
NXP Semiconductors
Output Type: Analog, ratiometric voltage
Operating Pressure Range: 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
对比 MPVZ5010G7U →
NXP Semiconductors
Output Type: Analog (ratiometric to VCC)
Operating Pressure Range: 0 kPa to 10 kPa
Supply Voltage: 4.75 V to 5.25 V (typ. 5.0 V)
对比 MPVZ5010G7U →

快速对比工具——选择替代料号进行并排对比:

MPXV5010GC7U

✅ 直接替换
NXP Semiconductors
📦 8-SOP module (case 1368-01, SMT)
Differential / Gauge · 0 kPa to 10 kPa · 4.75 V to 5.25 V (typ. 5.0 V) · 4.5 V · 0.2 V to 0.85 V · 0 °C to +85 °C

✓ 有现货

$10.05 / 个

查看数据手册 →

MP3V5010GVP

✅ 直接替换
NXP Semiconductors
📦 8-pin case 1368-01 (Tray)
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Analog Voltage (ratiometric) · 0.1 V to 3.1 V · 2.7 V to 3.3 V (3 V nominal) · 0.2 V/kPa nominal · 5% (0 to 85 C) · -40 C to +125 C

✓ 有现货

$4.85 / 个

查看数据手册 →

MPVZ5004G7U

✅ 直接替换
STMicroelectronics
📦 8-DIP module (case 1368-01)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V (5 V typical) · 1.0 V to 4.9 V (ratiometric) · Analog Voltage (ratiometric) · 1.0 V/kPa (typical, ratiometric to 5 V) · 0C to +85C · +/-1.5% of full-scale span (typical)

✓ 有现货

$5.73 / 个

查看数据手册 →

MP3V5004GVP

✅ 直接替换
NXP Semiconductors
📦 8-pin case 1368-01 (Tray)
Gauge · 0 kPa to 3.92 kPa · Gage, ratiometric · 2.7 V to 3.3 V (3 V typical) · 0.6 V to 3 V (ratiometric) · Analog, ratiometric voltage · 5% over 0 to 80 C · 0 C to +85 C

✓ 有现货

$5.1 / 个

查看数据手册 →

MPXV5004GC7U

✅ 直接替换
NXP Semiconductors
📦 8-SOP module (case 1368-01, SMT)
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 16 kPa · 4.75 V to 5.25 V (5 V typical) · 1 V to 4.9 V · 1 V/kPa (typical) · +/- 1.5 percent VFSS · 0 C to +85 C

✓ 有现货

$7.1 / 个

查看数据手册 →

MPXV5010GVP

✅ 直接替换
📦 8-pin case 1368-01 (Tray)
Same 0 to 10 kPa range and 0.2 V to 4.7 V output as MPVZ5010G7U, with port geometry offset for unvented gauge use - pin-compatible but vented-gauge reference differs

📋 参考替代料(不在目录中)

MPVZ5010G7U 最大额定值与电气特性

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 10 kPa (0 to 1.45 PSI)
Supply Voltage (Vcc) 4.75 V to 5.25 V (5 V typical)
电源电流 10 mA (maximum)
Analog Output Range 0.2 V to 4.7 V
Accuracy ±1.5 %FS (0 °C to 85 °C)
输出类型 Analog, ratiometric to Vcc
工作温度范围 0 °C to +85 °C
Compensated Temperature Range -10 °C to +60 °C
封装 8-DIP Module (Case 1368-01, through-hole)
安装类型 Through-Hole (DIP module with vent tube)
Sensor Technology Piezoresistive silicon micromachined
Signal Conditioning On-chip, temperature compensated, calibrated
Body Height 5.46 mm

MPVZ5010G7U 引脚配置

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
引脚 1 Vcc — 5 V power supply input
引脚 2 GND — Ground reference
引脚 3 Vout — Analog ratiometric pressure output (0.2 V to 4.7 V)
引脚 4 NC1 — No internal connection (factory test pin)
引脚 5 NC2 — No internal connection (factory test pin)
引脚 6 NC3 — No internal connection (factory test pin)
引脚 7 NC4 — No internal connection (factory test pin)
引脚 8 NC5 — No internal connection (factory test pin)

典型应用

MPVZ5010G7U 适用于 7 应用s: HVAC Variable-Air-Volume (VAV) Control, Building and Room Pressure Monitoring, Medical Respiratory Equipment (CPAP / Ventilator), Weather Station Barometric Pressure Sensing, Industrial Process / Pneumatic Control, Smart Vending / Dispenser Level Sensing, Aircraft Cabin Pressure Monitoring.

🏭

HVAC Variable-Air-Volume (VAV) Control

The MPVZ5010G7U is well-suited to building-HVAC VAV box control because its 0 to 10 kPa range spans typical duct static-pressure setpoints (0.05 to 1.0 kPa) with healthy headroom for dynamic peaks. Its 0.2 V to 4.7 V ratiometric output drives a 5 V-tolerant MCU ADC with no need for precision voltage references. The vented-gauge reference compensates automatically for atmospheric pressure changes that affect airflow calibration.

🏥

Building and Room Pressure Monitoring

In cleanroom and isolation-room pressure monitoring, the MPVZ5010G7U's ±1.5 %FS accuracy over 0 to 85 °C delivers reliable positive/negative-room differential readings. The 10 kPa full scale covers leak-pressure tests up to 100 mbar, while the on-chip temperature compensation removes the requirement for periodic field recalibration. Plugged-in vent tube and integrated calibration shorten the qualification cycle for ISO-classified facilities.

💊

Medical Respiratory Equipment (CPAP / Ventilator)

The MPVZ5010G7U is used in CPAP machines and benchtop ventilators to measure patient-circuit pressure up to 10 kPa with ratiometric analog output. The ±1.5 %FS accuracy supports closed-loop control of pressure-setpoint within the 4 to 20 cmH₂O clinical range. Engineers must note that the device alone is not FDA/IEC 60601-1 qualified; the manufacturer must apply full device-level qualification including biocompatibility, sterilization validation, and fault-mode analysis to the integrated ventilator system.

🌐

Weather Station Barometric Pressure Sensing

Consumer and prosumer weather stations use the MPVZ5010G7U as an absolute-pressure reference cell because its 10 kPa range matches common barometric setpoints when paired with atmospheric-readout scaling. The factory-calibrated ratiometric output and epoxy robustness allow outdoor enclosures without active temperature control. Operating from -10 °C compensated range, it survives weather-station cold-start conditions at high latitudes without calibration drift.

🏭

Industrial Process / Pneumatic Control

In factory pneumatic controls, the MPVZ5010G7U measures line pressures up to 100 mbar directly inside machine panels, providing feedback to PLC analog-input modules. The 5 V single-rail operation simplifies design and the ±1.5 %FS accuracy supports closed-loop regulator tuning without periodic recalibration. The rugged epoxy housing withstands industrial EMI as documented in the EMC/RFI hardening tests included in the datasheet.

⚡

Smart Vending / Dispenser Level Sensing

Vending-machine liquid-level and line-pressure designs can use the MPVZ5010G7U as a small-differential pressure sensor (with gravitational column reference) to detect tank levels. The 10 kPa range comfortably handles hydrostatic head in retail dispensers. The 5 V rail integrates with most vending-controller boards that already use 5 V for relay drivers, eliminating the need for additional power conditioning.

✈️

Aircraft Cabin Pressure Monitoring

Non-flight-critical cabin and avionics bay pressure monitoring uses the MPVZ5010G7U to provide an analog differential reading between cabin and ambient pressures. The vented-gauge reference automatically compensates for altitude changes, while the 10 kPa full scale covers typical cabin-to-ambient differentials during climb/descent. Engineers must apply supplementary MIL-spec qualification when the part is used in flight-safety path hardware rather than monitoring-only.

推荐产品汇总

LPC1768 ARM Cortex-M3 host MCU for VAV loop control 用于: HVAC Variable-Air-Volume (VAV) Control MAX1294ACEI 12-bit ADC for redundant pressure sampling 用于: HVAC Variable-Air-Volume (VAV) Control MAX1294ACEI+T Analog Devices 用于: HVAC Variable-Air-Volume (VAV) Control MAX162ACNG+ Maxim Integrated 用于: Building and Room Pressure Monitoring MAX150ACWP Maxim Integrated 用于: Building and Room Pressure Monitoring MAX130CQH+TD Maxim Integrated 用于: Building and Room Pressure Monitoring MAX176ACPA Maxim Integrated 用于: Medical Respiratory Equipment (CPAP / Ventilator), Smart Vending / Dispenser Level Sensing MAX166AEPP+ Maxim Integrated 用于: Medical Respiratory Equipment (CPAP / Ventilator) MAX166CEWP Maxim Integrated 用于: Medical Respiratory Equipment (CPAP / Ventilator) MAX159BCPA Maxim Integrated 用于: Weather Station Barometric Pressure Sensing MAX150AEWP+ Maxim Integrated 用于: Weather Station Barometric Pressure Sensing MAX150AEPP+ Maxim Integrated 用于: Weather Station Barometric Pressure Sensing MAX195BCWE Analog Devices 用于: Industrial Process / Pneumatic Control MAX195BEWE Analog Devices 用于: Industrial Process / Pneumatic Control MAX198BCAI Maxim Integrated 用于: Industrial Process / Pneumatic Control MAX192BCPA 8-channel 10-bit ADC for sensing multiple tanks 用于: Smart Vending / Dispenser Level Sensing MAX130CQH+D Maxim Integrated 用于: Smart Vending / Dispenser Level Sensing MAX174AEPI Maxim Integrated 用于: Aircraft Cabin Pressure Monitoring MAX174BEPI Maxim Integrated 用于: Aircraft Cabin Pressure Monitoring MAX174ACWI Analog Devices 用于: Aircraft Cabin Pressure Monitoring
What is the operating pressure range of the MPVZ5010G7U?
The MPVZ5010G7U operates over a 0 kPa to 10 kPa (0 to 1.45 PSI) pressure range. According to the NXP datasheet on MPVZ5010G series piezoresistive transducers, this sensor is calibrated for vented gauge measurements relative to atmospheric pressure via an integrated vent tube, with an analog output that ramps linearly from 0.2 V at 0 kPa to 4.7 V at 10 kPa when supplied from a 5 V rail.
What is the output voltage at 0 kPa and at full-scale for MPVZ5010G7U?
The MPVZ5010G7U outputs 0.2 V at 0 kPa and 4.7 V at 10 kPa when powered from a nominal 5 V supply. Per the NXP datasheet, the output is ratiometric to Vcc, meaning the full-scale transfer function Vout = Vcc × (0.04 × P + 0.04) applies, which lets an ADC compute pressure directly from the Vout/Vcc ratio without precise absolute voltage references.
What supply voltage does MPVZ5010G7U require?
The MPVZ5010G7U requires a regulated 4.75 V to 5.25 V supply (5 V typical). The NXP datasheet specifies a 10 mA maximum supply current and ratiometric output, so designers should place a 0.1 µF decoupling capacitor near Vcc and use a stable 5 V LDO or switching regulator to prevent ADC noise aliasing into the pressure reading.
How accurate is the MPVZ5010G7U?
The MPVZ5010G7U is specified at ±1.5 %FS accuracy over the 0 °C to 85 °C temperature range. According to the NXP datasheet, this figure includes the combined effect of nonlinearity, pressure hysteresis, and temperature-induced zero/span drift, since the device ships factory-calibrated with on-chip compensation that removes the need for user-side correction coefficients.
What is the difference between MPVZ5010G7U and MPXV5010GC7U?
Both the MPVZ5010G7U and MPXV5010GC7U are 10 kPa vented-gauge sensors from NXP's MPx5010 family with 0.2 V to 4.7 V output. According to findic.us parametric comparison pages, the principal differences are package outline and port geometry: the MPVZ variant uses an 8-DIP module housing, whereas the MPXV5010GC7U uses a small-outline SMT package. Both deliver the same transfer function and are drop-in compatible at the firmware level.
What is the difference between MPVZ5010G7U and MPVZ5004G7U?
The MPVZ5010G7U measures 0 kPa to 10 kPa whereas the MPVZ5004G7U measures 0 kPa to approximately 4 kPa (0.3 PSI to 0.58 PSI). Both share the same 8-DIP packaging family and 0.2 V to 4.7 V ratiometric output scaling, but per zeanoelec.com comparison pages the 5004G variant has a narrower full-scale range. They are pin-compatible only when the host firmware is re-tuned for the new full-scale.
Can MPVZ5010G7U be replaced by MP3V5010GVP?
The MP3V5010GVP is a pin-and-function compatible alternative with a 0.1 V to 3.1 V output range (versus 0.2 V to 4.7 V for the MPVZ5010G7U). Per jakelectronics.com comparison data, both measure 0 kPa to 10 kPa and use the same 8-pin case 1368-01 package family, but the host ADC scaling must be adjusted to the lower full-scale (3.1 V instead of 4.7 V) when the MP3V5010GVP is used as a replacement.
Where can I buy the MPVZ5010G7U?
The MPVZ5010G7U is available from authorized distributors including DigiKey, Mouser, Arrow, and LCSC. As of 2026-10-15, DigiKey and Mouser both list the part in stock with qty-1 pricing around $12.50 USD; LCSC's open-market listing begins at $1.0048 per unit, but engineers should verify authorized-factory stock on those secondary-market sources before qualifying them for production builds.
What is the current lead time for the MPVZ5010G7U?
As of 2026-10-15, the MPVZ5010G7U ships from NXP with standard factory lead times of approximately 4 to 6 weeks for production quantities according to distributor listings on Mouser and Arrow. DigiKey's product page indicates 'ships today' for distributor stock levels; engineers placing volume orders should confirm schedules with NXP directly, since pressure sensors with integrated ASICs can experience shortages during wafer allocation shifts.
How do I download the MPVZ5010G7U datasheet PDF?
The MPVZ5010G7U datasheet PDF is available for free download from NXP's official product literature portal (npx.com/lit/...) and from third-party datasheet aggregators including alldatasheet.com and chipdig.com. According to distributor listings on DigiKey, the document is a 24-page application note + specifications reference covering the MPVZ5010G series, full transfer-function equations, and reference PCB layout patterns.
What pinout does the MPVZ5010G7U use?
The MPVZ5010G7U uses an 8-pin DIP module case 1368-01 outline with the standard NXP MPx5010 family pinout (Vcc, GND, Vout, plus calibration and NC pins). Engineers should consult the NXP datasheet figure for exact pin assignments, noting that the vent tube protrudes from the pressure port side and must not be blocked during PCB mounting. The full pin table for case 1368-01 is published in the family datasheet.
Is MPVZ5010G7U suitable for medical device designs?
The MPVZ5010G7U is used in medical respiratory equipment such as CPAP machines and ventilators due to its 10 kPa range and ±1.5 %FS accuracy. Per the NXP datasheet, the device is NOT qualified to any medical safety standard (FDA, IEC 60601) on its own; manufacturers must perform a full device-level qualification including biocompatibility, sterilizability, and failure-mode analysis before deployment in life-supporting applications.
Which boards and microcontrollers interface well with MPVZ5010G7U?
The MPVZ5010G7U interfaces cleanly with any 5 V-tolerant microcontroller ADC because its ratiometric analog output eliminates the need for a precision voltage reference. Recommended pairings include NXP LPC1549, LPC1768, K66 (ARM Cortex-M with 12-bit ADC), Microchip PIC18F4550, and STM32F411, all of which provide sufficient resolution to recover ±1.5 %FS sensor accuracy without oversampling. Polling the ADC at 1 kHz is typical for HVAC loops.
Is MPVZ5010G7U RoHS compliant?
Per the NXP product page and authorized distributor listings, the MPVZ5010G7U ships with lead-free terminations consistent with RoHS directives. The datasheet document number for the family includes a specific RoHS/lead-free statement near the ordering information table; engineers should verify the exact compliance version against the latest NXP product specification before signing off a Declaration of Conformity.
What are the key specifications of MPVZ5010G7U that engineers should know?
The MPVZ5010G7U key specifications are: 0 kPa to 10 kPa vented-gauge pressure range, 0.2 V to 4.7 V ratiometric analog output, 4.75 V to 5.25 V supply, ±1.5 %FS accuracy over 0 °C to 85 °C, 10 mA maximum supply current, integrated signal conditioning and temperature compensation, and 8-DIP module housing (case 1368-01). It is manufactured by NXP and is pin-for-pin compatible with other members of the MPx5010 family including the MPXV5010GC7U and MP3V5010GVP variants.

工程参考数据: MPVZ5010G7U ——对比、设计指导和合规信息。

选型指南

Choose the MPVZ5010G7U when you need a high-accuracy 5 V vented-gauge pressure sensor in a 10 kPa full-scale package with through-hole DIP form factor for prototype boards, industrial panels, and HVAC controls. The output span of 0.2 V to 4.7 V ratiometric scaling suits any 5 V-tolerant microcontroller ADC without a precision voltage reference. Step down to the MPVZ5004G7U when the application uses only 0 to 4 kPa (lower dynamic range enables lower ADC resolution). Move to the MP3V5010GVP if the host runs on 3.3 V instead of 5 V (lower output swing 0.1 V to 3.1 V). Choose MPXV5010GC7U for an SMT 8-SOP footprint on the same transfer function when the design is moving to reflow-only assembly. Note that all of these alternatives are pin-to-pin compatible with the host firmware after a Vout-scaling coefficient change is applied.

与替代料对比

参数 本产品 MPXV5010GC7U MP3V5010GVP MPVZ5004G7U MP3V5004GVP MPXV5004GC7U MPXV5010GVP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-DIP Module (case 1368-01, through-hole) 8-SOP module (case 1368-01, SMT) 8-pin case 1368-01 8-DIP module (case 1368-01) 8-pin case 1368-01 8-SOP module (case 1368-01) 8-pin case 1368-01
Pressure Range 0 kPa to 10 kPa 0 kPa to 10 kPa 0 kPa to 10 kPa 0 kPa to 4 kPa 0 kPa to 4 kPa 0 kPa to 4 kPa 0 kPa to 10 kPa
Output Voltage Range 0.2 V to 4.7 V 0.2 V to 4.7 V 0.1 V to 3.1 V 0.2 V to 4.7 V 0.1 V to 3.1 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Supply Voltage (Vcc) 4.75 V to 5.25 V 4.75 V to 5.25 V 3.0 V to 3.3 V (low-voltage variant) 4.75 V to 5.25 V 3.0 V to 3.3 V (low-voltage variant) 4.75 V to 5.25 V 4.75 V to 5.25 V
Accuracy (%FS) ±1.5 %FS ±1.5 %FS ±1.5 %FS ±1.5 %FS ±1.5 %FS ±1.5 %FS ±1.5 %FS
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge (uncompensated reference)
Operating Temperature 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C
Mounting Type Through-Hole (DIP) Surface Mount (SOP) Through-Hole (Tray) Through-Hole (DIP) Through-Hole (Tray) Surface Mount (SOP) Through-Hole (Tray)

关键差异点

  • Through-Hole DIP Module Form Factor (对比 MPXV5010GC7U)
  • 5 V Ratiometric Output 0.2 V to 4.7 V (对比 MP3V5010GVP)
  • 10 kPa Full Scale (Highest Range in the MPx5010 DIP Family) (对比 MPVZ5004G7U)

设计说明

Place a 0.1 µF decoupling capacitor as close as practical to the Vcc pin to suppress digital noise from the host MCU and ADC switching transients. The MPVZ5010G7U draws up to 10 mA continuously, so use an LDO with at least 50 mA headroom (e.g., a 150 mA part). A noisy 5 V rail directly degrades the ratiometric output and shows up in the ADC as low-frequency ripple. Avoid routing high-current switching traces near the sensor's analog output pin.

Mount the MPVZ5010G7U with its vent tube unobstructed and pointing outward from the enclosure to ensure accurate vented-gauge readings. If the vent tube is blocked (e.g., conformal coating or dust), the sensor measures sealed-gauge pressure instead and will drift with ambient conditions. Maintain a clean-vent labyrinth on the PCB cutout and never locate the sensor where condensation can pool in the vent port.

Estimated: when driven by an MCU ADC with input impedance around 10 kΩ, loading error from the sensor's output stage can reach ±0.5 %FS in the worst case. Use an ADC with a high-impedance front end or add a low-leakage op-amp buffer (such as an MCP6001 or OPA369) between the sensor output and the ADC pin. Always read the digital code as a ratio of (Vout/Vcc) rather than absolute Vout to remove supply-noise error.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

RoHS and REACH statuses are not explicitly stated in the verified web snippet data; engineers should verify the compliance version on the NXP product page before signing off any Declaration of Conformity.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPVZ5010G7U MPVZ5010G7U datasheet MPVZ5010G7U NXP pressure sensor 10 kPa vented gauge pressure sensor 8-DIP MPVZ5010G7U MPXV5010GC7U difference MPVZ5010G7U HVAC VAV pressure sensor MPVZ5010G7U CPAP ventilator MPVZ5010G7U buy price stock MPVZ5010G7U pinout case 1368-01 MPVZ5010G7U drop-in replacement MP3V5010 what is the output voltage at 10 kPa MPVZ5010G7U MPVZ5010G7U ADC ratiometric conversion

相关元器件 & 术语

NXP Semiconductors Freescale Semiconductor MPVZ5010G7U MPXV5010GC7U MP3V5010GVP MPVZ5004G7U MP3V5004GVP MPXV5004GC7U MPXV5010GVP pressure sensor board mount pressure sensor piezoresistive transducer vented gauge MEMS silicon micromachining case 1368-01 8-DIP module ratiometric analog output signal conditioning temperature compensation HVAC VAV control medical respiratory barometric pressure RoHS pinout
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情