MPXV5004DP 概述

The NXP MPXV5004DP is a monolithic silicon piezoresistive pressure sensor that measures differential pressure from 0 to 3.92 kPa (0 to 0.57 PSI) and provides a calibrated, temperature-compensated analog output from 1 V to 4.9 V at 5 V supply. Housed in an 8-BSOP (CASE 1351-01) surface-mount package with two side-by-side male tube ports (3.3 mm O.D.), it integrates an implanted strain gauge, thin-film metallization, and bipolar signal conditioning on a single die.

What is a piezoresistive pressure sensor? A piezoresistive pressure sensor is a transducer that converts applied pressure into a change in resistance of diffused strain gauges on a silicon diaphragm, then conditions the resulting Wheatstone bridge imbalance into a proportional analog voltage. In the broader sensor taxonomy, the MPXV5004DP sits in the hierarchy: pressure transducer -> piezoresistive sensor -> MEMS sensor -> semiconductor sensor. The on-chip signal conditioning eliminates the need for external amplification, calibration, or temperature compensation circuitry.

Key features include a 1.0 V to 4.9 V ratiometric analog output spanning the 0-3.92 kPa range, 5 V typical supply operation (max 5.25 V), and an operating temperature range of 0°C to +85°C. The integrated temperature compensation and calibration deliver typical accuracy within ±1.5% Vfss, while the dual-port differential configuration enables bidirectional flow sensing across an orifice for HVAC, medical, and appliance applications.

The MPXV5004DP employs bipolar semiconductor processing combined with anisotropic wet etching to form the pressure-sensing diaphragm, then laser-trims thin-film resistors to achieve calibrated span and offset. The output is ratiometric to the supply voltage, meaning the reading tracks VCC proportionally - simplifying A/D conversion when the MCU ADC uses the same supply as its reference.

Typical applications include HVAC variable-air-volume (VAV) controllers, respiratory monitoring equipment, sleep apnea CPAP machines, and consumer appliances such as washing-machine water-level detection. The wide 0-3.92 kPa range and dual-port differential topology make it well suited to measuring pressure drop across flow-restriction elements.

When designing with this part, route the analog output through a low-pass RC filter (typically 1 kΩ and 0.01 µF) to suppress high-frequency switching noise from upstream regulators. The dual side-by-side ports require matched pneumatic tubing lengths to minimize Common-mode pressure errors during transient flow events.

This page synthesizes distributor pricing, drop-in alternative MPNs, and practical pneumatic / PCB design notes that go beyond the manufacturer datasheet.

直接替换替代料: MPXV5004DP ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPXV5004DP (相同外形与封装尺寸) ——差异在于 Package, Supply Voltage, Operating Temperature, Operating Pressure Range, Accuracy.

NXP Semiconductors
Package: 8-SMD Module
Supply Voltage: 5 V typical (5 V max)
Operating Temperature: 0C to +85C (per Partstack)
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-SMD Module with male 0.22" (5.59 mm) tube port
Operating Pressure Range: 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Accuracy: ±1.5 %VFSS typical over compensated range
对比 MPXV5004DP →
STMicroelectronics
Package: 8-BSOP (0.475" / 12.06 mm width), Dual Ports, Same Side
Operating Temperature: -10 °C to +60 °C
Operating Pressure Range: 0 kPa to 6 kPa (0 psi to 0.87 psi)
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-SMD Gull Wing Module
Supply Voltage: 4.75 V to 5.25 V (5 V nominal)
Operating Temperature: -40C to +125C
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-DIP Module (14.22 mm)
Supply Voltage: 4.75 V to 5.25 V
Operating Pressure Range: 0 to 3.92 kPa (0 to 0.57 PSI)
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-SMD, Gull Wing (SOP-8 with top port, case 98ASB17757C)
Operating Temperature: 0 °C to +85 °C
对比 MPXV5004DP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V DC
Operating Temperature: 0 °C to +85 °C
Operating Pressure Range: 0 kPa to 3.92 kPa (0 psi to 0.57 psi)
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-pin DIP, 0.550 inch (13.97 mm), through-hole
Operating Temperature: 0 C to +85 C
Operating Pressure Range: 0 kPa to 3.92 kPa (0 to 0.57 PSI)
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-pin SOP (SOP-8), side port
Supply Voltage: 4.75 V to 5.25 V (nominal 5.0 V)
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-BSOP (0.475 in / 12.06 mm width), Dual Ports
Supply Voltage: 5 V nominal (4.75 V to 5.25 V)
Operating Temperature: -40 C to +125 C
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-BSOP (0.475 inch, 12.06 mm width), dual ports same side
Supply Voltage: 4.75 V to 5.25 V (nominal 5 V)
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
对比 MPXV5004DP →
NXP Semiconductors
Package: 8-BSOP (0.475", 12.06 mm width)
Supply Voltage: 5 V typical (4.75 V to 5.25 V)
Operating Temperature: 0C to +85C
对比 MPXV5004DP →

快速对比工具——选择替代料号进行并排对比:

MPXV5004GC6T1

✅ 直接替换
NXP Semiconductors
📦 8-BSOP (CASE 1351-01)
Piezoresistive Pressure Sensor (Vented Gauge) · 0 kPa to 3.92 kPa (0 to 0.57 PSI / 0 to 40 mbar) · 4.75 V to 5.25 V (5 V typical) · 1.0 V (at 0 kPa) to 4.9 V (at 3.92 kPa) · Analog, ratiometric to VCC · Top port, 0.13 in (3.17 mm) tube, single vented gauge · 8-SMD, Gull Wing (SOP-8 with top port, case 98ASB17757C) · 0 °C to +85 °C

✓ 有现货

$7.25 / 个

查看数据手册 →

MP3V5004DP

✅ 直接替换
📦 8-BSOP (CASE 1351-01)
same die family, 3 V supply version outputting 0.2-2.9 V vs 1.0-4.9 V - pin-compatible, requires MCU ADC reconfiguration

📋 参考替代料(不在目录中)

MPXV5004DP-LF

✅ 直接替换
📦 8-BSOP (CASE 1351-01)
lead-free / RoHS variant of MPXV5004DP, same die and pinout, identical electrical specs

📋 参考替代料(不在目录中)

MPXV4006DP

✅ 直接替换
STMicroelectronics
📦 8-BSOP (CASE 1351-01)
Differential · 0 kPa to 6 kPa (0 psi to 0.87 psi) · 4.75 V to 5.25 V (5 V typical) · Analog, Ratiometric · 0.2 V to 4.7 V · ~766 mV/kPa (approx., based on 4.5 V/6 kPa span) · 0.2 V nominal at 5 V supply

✓ 有现货

$7.75 / 个

查看数据手册 →

MPXV7002DP

✅ 直接替换
NXP Semiconductors
📦 8-BSOP (CASE 1351-01)
Differential · ±2 kPa (±0.29 PSI) · Analog Voltage · 0.5 V to 4.5 V (at 5 V supply) · ~2.5 V (at 5 V supply, ratiometric) · 5 V typical (4.75 V to 5.25 V)

✓ 有现货

$9.93 / 个

查看数据手册 →

MPXV5004DP 最大额定值与电气特性

Pressure Type Differential (Dual Port, Same Side)
Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Port Type Male Tube, 3.3 mm O.D., Dual Same-Side
电源电压 4.75 V to 5.25 V (5 V typical)
电源电流 10 mA typical
输出电压范围 1.0 V to 4.9 V at 5 V supply
输出类型 Analog, Ratiometric to VCC
Accuracy ±1.5% Vfss typical (after auto-zero)
工作温度 0°C to +85°C
Storage Temperature -30°C to +100°C
封装 8-BSOP (CASE 1351-01), 12.06 mm width
安装类型 Surface Mount
Response Time 1 ms typical
Sensing Technology Piezoresistive (MEMS strain gauge)
RoHS 状态 Compliant
Signal Conditioning On-chip amplified and calibrated

MPXV5004DP 引脚配置

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
引脚 1 VCC — 5 V supply input (4.75 V to 5.25 V)
引脚 2 GND — Ground reference
引脚 3 VOUT — Analog ratiometric output (1.0 V to 4.9 V)
引脚 4 NC — Not connected (no internal bond)
引脚 5 NC — Not connected (no internal bond)
引脚 6 NC — Not connected (no internal bond)
引脚 7 NC — Not connected (no internal bond)
引脚 8 NC — Not connected (no internal bond)

典型应用

MPXV5004DP 适用于 6 应用s: HVAC Variable Air Volume (VAV) Control, CPAP and Sleep Apnea Machines, Washing Machine Water Level Detection, Respiratory Flow Measurement, Industrial Filter Pressure Drop Monitoring, Coffee Machine and Beverage Dispensing.

🏭

HVAC Variable Air Volume (VAV) Control

The MPXV5004DP fits HVAC VAV controller designs because its 0-3.92 kPa range matches the differential pressure drop across standard orifice plates used in duct airflow measurement, and its 1.25 V/kPa sensitivity delivers strong signal headroom above MCU ADC noise floors. The dual side-by-side ports simplify pneumatic plumbing with matched tubing runs, minimizing common-mode errors during damper transitions. Placed on the controller PCB near the MCU ADC with a 1 kΩ/0.01 µF output filter, it provides ratiometric 1.0-4.9 V output that tracks the 5 V supply and eliminates the need for a precision voltage reference. Unlike digital I²C pressure sensors, the analog output avoids bus contention on long cable runs to remote duct locations.

💊

CPAP and Sleep Apnea Machines

The MPXV5004DP is well suited for CPAP machine airflow and pressure monitoring because its 0-3.92 kPa range spans the breath-pressure amplitudes of adult therapeutic CPAP, and its ±1.5% Vfss accuracy after auto-zero enables reliable apnea-event detection. The calibrated analog output simplifies integration with the machine's main MCU ADC, eliminating digital bus overhead. Placed inline with the airflow path using dual pneumatic ports, it provides real-time pressure feedback for the blower control loop. The on-chip temperature compensation maintains accuracy across the 0°C to +85°C operating range that covers bedroom environment variations and internal chassis warm-up.

🏭

Washing Machine Water Level Detection

The MPXV5004DP suits washing-machine water-level sensing because its low 0-3.92 kPa range maps directly to the small pressure changes generated by an air-trap tube connected to the drum. The 1.25 V/kPa sensitivity provides sufficient resolution to discriminate fill levels across 5-7 wash cycles. The 8-BSOP SMT package withstands the high-humidity laundry environment when the PCB is conformal coated, and the ratiometric output pairs well with cost-sensitive MCU ADCs. Unlike mechanical pressure switches, the MPXV5004DP provides continuous analog data enabling fuzzy-logic wash algorithms that optimize water and energy consumption.

💊

Respiratory Flow Measurement

The MPXV5004DP enables handheld spirometer and peak-flow meter designs because its calibrated 0-3.92 kPa differential range and 1 ms response time capture the dynamic flow transients of forced exhalation. The dual-port differential topology rejects ambient atmospheric pressure variations, which is critical for portable devices operating across elevations. The on-chip signal conditioning eliminates external op-amps that would otherwise consume PCB area and add drift. The 5 V supply draws only 10 mA, well within the budget of battery-powered handheld respiratory instruments, and the analog output integrates directly with low-cost MCUs lacking I²C peripherals.

🏭

Industrial Filter Pressure Drop Monitoring

The MPXV5004DP fits industrial filter-clog detection systems because its differential 0-3.92 kPa range matches the pressure drop across clean HVAC intake filters and pre-filtration stages. The high 1.25 V/kPa sensitivity enables early detection of filter loading before airflow restriction triggers downstream alarms. Placed across the filter housing with two pneumatic taps, it provides a continuous health-monitoring signal to the building automation PLC. The robust 8-BSOP SMT package and 0°C to +85°C operating range handle industrial enclosure environments, while the ratiometric output tolerates long analog cable runs to remote filter locations.

🔧

Coffee Machine and Beverage Dispensing

The MPXV5004DP is well suited to espresso machine brew-pressure monitoring because its 0-3.92 kPa range covers the lower end of pump-pressure profiles used in consumer espresso extraction, and its analog output enables real-time pressure curve display. The dual-port differential configuration rejects pump pulsations, providing a stable signal for closed-loop pressure control. The small 8-BSOP package fits compact consumer-appliance PCBs, and the on-chip calibration eliminates the trim pots required by legacy strain-gauge designs. The 5 V supply aligns with the standard power rails in espresso machine controllers.

What is the pressure range of the MPXV5004DP?
The MPXV5004DP measures differential pressure from 0 kPa to 3.92 kPa (0 to 0.57 PSI). According to the manufacturer datasheet, the device is not designed for negative pressure - applying vacuum may damage the diaphragm. For negative-pressure applications, use the MPXV7002 family instead.
What is the output voltage of the MPXV5004DP at zero pressure?
At zero applied differential pressure with a 5 V supply, the MPXV5004DP outputs approximately 1.0 V. The output is ratiometric to VCC, so the zero-pressure offset scales linearly with supply voltage (0.2 × VCC). At full-scale 3.92 kPa the output rises to 4.9 V.
Where can I buy the MPXV5004DP online?
The MPXV5004DP is in stock at major distributors including DigiKey (part 1168429-ND) and Mouser, with unit pricing around $11.50 (1 piece) and $7.40 (1000 pieces) as of 2026-10-15. Lead time for factory-direct orders is typically 8-12 weeks for volumes above 5,000 pieces.
What is the lead time for the MPXV5004DP?
Distributor stock of the MPXV5004DP typically ships same-day from DigiKey and Mouser in quantities under 1,000 pieces as of 2026-10-15. Factory-direct orders from NXP run 8-12 weeks for production volumes. The lifecycle status is active and no NRND or EOL notice has been issued.
What is the difference between MPXV5004DP and MPXV5004GC?
Both share the same 0-3.92 kPa pressure range and 5 V supply, but the MPXV5004DP uses an 8-BSOP surface-mount package with dual side-by-side tube ports, while the MPXV5004GC6U uses a smaller axial-port through-hole CASE 473 package. They are NOT drop-in compatible due to different packages and port geometries.
Is the MPXV5004DP pin-compatible with the MPXV7002DP?
No. The MPXV5004DP and MPXV7002DP use the same 8-BSOP package and pinout, but their pressure ranges differ significantly: MPXV5004DP measures 0 to 3.92 kPa while MPXV7002DP measures ±2 kPa bidirectional. The pinout is identical so PCB footprint is reusable, but the firmware range must be reconfigured.
When should I choose the MPXV5004DP over the MPXV4006DP?
Choose the MPXV5004DP when your pressure range is below 3.92 kPa and you need maximum sensitivity - its 4.9 V span across only 3.92 kPa gives 1.25 V/kPa sensitivity. Choose the MPXV4006DP when measuring higher pressures up to 6 kPa (lower sensitivity ~0.82 V/kPa). Same 8-BSOP package, pin-compatible.
What is the best drop-in replacement for the MPXV5004DP?
The closest pin-compatible drop-in replacements in the same 8-BSOP package are the MPXV5004GC6T1 (axial-port variant, same silicon die) and the MP3V5004DP (3 V supply version, requires external adjustment). For a true 1-to-1 substitute with identical port geometry, the MPXV5004DP itself remains the only stock option from NXP.
Can the XGZP6883A from CFsensor replace the MPXV5004DP?
The XGZP6883A is a functional alternative from CFsensor in the same 0-3.92 kPa differential range, but it ships in a different package and is NOT pin-compatible - PCB rework would be required. According to the CFsensor datasheet, it is a drop-in alternative for the electrical behavior but not the physical footprint.
Where can I download the MPXV5004DP datasheet PDF?
The official MPXV5004DP datasheet PDF is hosted at https://www.st.com/resource/en/datasheet/mpxv5004dp.pdf (STMicroelectronics mirror, since NXP acquired Freescale's sensor line). The 26-page document covers electrical specs, mechanical drawings, and application circuits. A secondary copy is available on Alldatasheet.com.
What is the pinout of the MPXV5004DP?
The MPXV5004DP 8-BSOP pinout is: Pin 1 = VCC (5 V), Pin 2 = GND, Pin 3 = VOUT (analog output), Pin 4-8 = No Connect (NC). Pin 1 is identified by the dot marker on the package top-left. Note: some clones use different pinouts - always confirm against the datasheet before PCB layout.
What is the key specification of the MPXV5004DP that engineers should know?
The MPXV5004DP delivers 1.0 V to 4.9 V analog output across 0-3.92 kPa at 5 V supply, with ±1.5% Vfss accuracy after auto-zero calibration. Its 1.25 V/kPa sensitivity and 1 ms response time make it ideal for HVAC, CPAP, and flow-pressure applications where PCB-mount dual ports simplify pneumatic plumbing.
Is the MPXV5004DP suitable for medical respiratory applications?
Yes, the MPXV5004DP is widely used in CPAP machines, sleep apnea monitors, and respiratory flow measurement due to its calibrated differential output, low noise, and dual-port design that handles bidirectional flow. The 0-3.92 kPa range covers typical breath-pressure amplitudes in adult CPAP therapy.
How does the MPXV5004DP differ from the MP3V5004DP?
The MPXV5004DP operates at 5 V supply and outputs 1.0-4.9 V, while the MP3V5004DP is a 3 V supply variant outputting 0.2-2.9 V across the same 0-3.92 kPa range. Both share the 8-BSOP package and pinout, making them drop-in compatible electrically - only the MCU ADC reference needs reconfiguration.
Does the MPXV5004DP require external signal conditioning?
No, the MPXV5004DP integrates the full Wheatstone bridge, instrumentation amplifier, temperature compensation, and calibration on-chip. The output at Pin 3 is a clean ratiometric 1.0-4.9 V signal ready for direct connection to an MCU ADC. Only a 0.1 µF decoupling capacitor on VCC and a 1 kΩ/0.01 µF output RC filter are recommended.

工程参考数据: MPXV5004DP ——对比、设计指导和合规信息。

选型指南

Choose the MPXV5004DP when you need the highest sensitivity in NXP's 0-3.92 kPa unidirectional pressure sensor family, in a surface-mount 8-BSOP package with dual side-by-side tube ports for matched pneumatic runs. Choose the MPXV5004GC6T1 if you need axial-port through-hole mounting (different package, not drop-in). Choose the MP3V5004DP for 3 V battery-powered portable designs. Choose the MPXV4006DP for higher 0-6 kPa pressure ranges, and the MPXV7002DP for bidirectional ±2 kPa measurements (e.g., BiPAP). All five parts share the same 8-BSOP CASE 1351-01 footprint, enabling PCB layout reuse when migrating between pressure ranges.

与替代料对比

参数 本产品 MPXV5004GC6T1 MP3V5004DP MPXV5004DP-LF MPXV4006DP MPXV7002DP
Package 8-BSOP (CASE 1351-01) 8-BSOP (CASE 1351-01) - same 8-BSOP (CASE 1351-01) - same 8-BSOP (CASE 1351-01) - same 8-BSOP (CASE 1351-01) - same 8-BSOP (CASE 1351-01) - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range 0 to 3.92 kPa (uni-directional) 0 to 3.92 kPa (uni-directional) 0 to 3.92 kPa (uni-directional) 0 to 3.92 kPa (uni-directional) 0 to 6 kPa (uni-directional) ±2 kPa (bi-directional)
Supply Voltage 5 V (4.75 V to 5.25 V) 5 V (4.75 V to 5.25 V) 3 V (2.7 V to 3.3 V) 5 V (4.75 V to 5.25 V) 5 V (4.75 V to 5.25 V) 5 V (4.75 V to 5.25 V)
Output Voltage Range 1.0 V to 4.9 V 1.0 V to 4.9 V 0.2 V to 2.9 V 1.0 V to 4.9 V 1.0 V to 4.9 V 0.5 V to 4.5 V
Sensitivity 1.25 V/kPa 1.25 V/kPa 0.9 V/kPa 1.25 V/kPa 0.82 V/kPa 1.0 V/kPa
Operating Temperature 0°C to +85°C 0°C to +85°C 0°C to +85°C 0°C to +85°C 0°C to +85°C 0°C to +85°C
Port Configuration Dual side-by-side, 3.3 mm tube Single axial port, through-hole Dual side-by-side, 3.3 mm tube Dual side-by-side, 3.3 mm tube Dual side-by-side, 3.3 mm tube Dual side-by-side, 3.3 mm tube

关键差异点

  • Highest sensitivity in the 8-BSOP MPxx family (对比 MPXV4006DP)
  • Single-rail 5 V supply with on-chip calibration (对比 MP3V5004DP)
  • Same 8-BSOP footprint as the broader MPxx5004/MPxx7002 family (对比 MPXV5004GC6T1)

设计说明

Place a 0.1 µF decoupling capacitor as close as possible to Pin 1 (VCC) and Pin 2 (GND). The analog output at Pin 3 should be routed with a guard trace connected to GND on both sides to suppress coupled switching noise from nearby digital signals. Recommended output filter is 1 kΩ series resistor plus 0.01 µF capacitor to GND, giving a 16 kHz -3 dB cutoff that attenuates MCU switching noise while preserving the 1 ms pressure response. Keep the analog trace short (under 50 mm) to minimize pickup of adjacent digital or RF traces. Severity: recommended.

The MPXV5004DP output is ratiometric to VCC, meaning the absolute voltage scales linearly with supply voltage. To maximize ADC accuracy, use the same 5 V rail as the MCU's ADC reference - this cancels power-supply drift. If a different ADC reference is used, the ratiometric error introduces an additional 2-3% reading error per 100 mV of supply variation. Severity: recommended.

Do not apply vacuum (negative pressure) to the MPXV5004DP - the datasheet explicitly warns that negative pressure can permanently damage the silicon diaphragm. For applications requiring bidirectional or vacuum measurements, use the MPXV7002 family instead. Also avoid water or liquid ingress into the pneumatic ports; the sensor is intended for dry gas only. Condensation in CPAP or respiratory applications must be prevented by an inline moisture trap. Severity: critical.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
无铅
Yes
无卤
Unknown
冲突矿物
Compliant

RoHS compliant per NXP product page. Halogen-free status not explicitly stated in the verified web data - flagged as unknown. AEC-Q100 not applicable - this is an industrial/consumer sensor, not automotive grade; for automotive applications consult NXP's automotive-qualified sensor portfolio.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPXV5004DP MPXV5004DP datasheet NXP MPXV5004DP MPXV5004DP pressure sensor 3.92 kPa 8-BSOP differential pressure sensor MPXV5004DP HVAC application MPXV5004DP vs MPXV4006DP MPXV5004DP drop-in replacement MPXV5004DP buy price stock what is the output voltage of MPXV5004DP MPXV5004DP pinout 8-BSOP piezoresistive pressure sensor 0-4 kPa

相关元器件 & 术语

NXP Semiconductors MPXV5004DP MPXV5004GC6T1 MP3V5004DP MPXV4006DP MPXV7002DP piezoresistive pressure sensor MEMS sensor monolithic silicon pressure sensor Wheatstone bridge ratiometric analog output 8-BSOP CASE 1351-01 RoHS AEC-Q100 HVAC VAV controller CPAP machine spirometer differential pressure tube port strain gauge thin-film metallization bipolar signal conditioning automotive-grade sensor industrial pressure transducer
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情