MPXV5004GC6T1 Overview

The NXP MPXV5004GC6T1 is a piezoresistive, monolithic silicon pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, delivering an analog output voltage proportional to applied differential pressure over a 0 to 3.92 kPa (0 to 0.57 PSI) range from a single 5 V supply. The device is housed in an 8-pin SOP (Small Outline Package) with a top-side pressure port, gull-wing leads, and tape-and-reel packaging suitable for surface-mount assembly.

A pressure sensor is a transducer that converts a physical pressure input into an electrical signal, typically an analog voltage proportional to the applied force per unit area. Piezoresistive sensors use diffused strain gauges on a silicon diaphragm whose resistance changes with deflection; the resulting signal is then conditioned, compensated for temperature, and calibrated on the wafer. Pressure sensors sit within the broader sensor hierarchy as MEMS devices, themselves a category of semiconductor components that interface physical phenomena to electronics. The MPXV5004 family is commonly used in respiratory, HVAC, and instrumentation applications where vented gauge measurement is required.

Key features of the MPXV5004GC6T1 include a transfer function spanning 1.0 V at 0 kPa to 4.9 V at 3.92 kPa, a response time of approximately 1 ms, and an operating temperature range of 0°C to +85°C. The device incorporates a single-port vented gauge configuration with a 3.17 mm (0.13 inch) tube port on top, allowing direct connection to an airflow manifold. Output noise and accuracy are factory-calibrated, eliminating external compensation circuitry.

Internally, the MPXV5004GC6T1 is fabricated using NXP's (formerly Motorola Semiconductor) micromachining and thin-film metallization process on a bipolar substrate, integrating the sensing diaphragm and CMOS-compatible signal conditioning on a single die. The vented gauge reference port on the underside of the die references the back side of the diaphragm to atmosphere, enabling fully compensated gauge readings.

Typical applications include spirometers and CPAP airflow monitoring, HVAC variable air volume (VAV) controllers, industrial process instrumentation, pneumatic control feedback, and altitude/wind-pressure sensing in drone or weather stations. Its small SOP-8 footprint suits compact medical and consumer electronics.

When designing with this part, ensure the supply is well decoupled near the VCC pin (typically 1 µF ceramic) and keep the pressure port free of moisture, debris, and condensation that can corrupt gauge readings. The output is ratiometric to VCC, so a stable, low-noise 5 V rail is essential for stated accuracy.

This page synthesizes distributor stock, drop-in alternatives, and practical design notes drawn from the manufacturer datasheet and distributor listings not found in any one source.

Drop-in alternatives for MPXV5004GC6T1 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPXV5004GC6T1 (same form factor and footprint) — differing in Operating Temperature, Output Type, Package, Supply Voltage, Pressure Type.

NXP Semiconductors
Operating Temperature: 0C to +85C (per Partstack)
Output Type: Analog Voltage
Package: 8-SMD Module
Compare with MPXV5004GC6T1 →
STMicroelectronics
Operating Temperature: -40 C to +125 C
Output Type: Analog voltage, ratiometric
Package: 8-SMD, Gull Wing, Top Port (SOP-8)
Compare with MPXV5004GC6T1 →
NXP Semiconductors
Operating Temperature: 0°C to +85°C
Package: 8-BSOP (CASE 1351-01), 12.06 mm width
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Compare with MPXV5004GC6T1 →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Supply Voltage: 4.75 V to 5.25 V DC
Pressure Type: Vented Gauge
Compare with MPXV5004GC6T1 →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MPXV5004GC7T1

✅ Drop-In
📦 8-SMD Gull Wing (SOP-8 top port, case 98ASB17757C)
identical die and case, lead-free (Pb-free) finish variant of MPXV5004GC6T1

📋 Reference alternative (not in catalog)

MPXV5004GC6U

✅ Drop-In
NXP Semiconductors
📦 8-SMD Gull Wing (SOP-8 top port, case 98ASB17757C)
Vented Gauge · 0 kPa to 3.92 kPa (0 psi to 0.57 psi) · 4.75 V to 5.25 V DC · Analog Voltage (ratiometric) · 1.0 V to 4.9 V (at 5 V supply) · ±2.5 % (typical, 10 °C to 50 °C)

✓ In Stock

$8.3 / Unit

View Datasheet →

MPXV5004GC6T1

✅ Drop-In
NXP Semiconductors
📦 8-SMD Gull Wing (SOP-8 top port, case 98ASB17757C)
Piezoresistive Pressure Sensor (Vented Gauge) · 0 kPa to 3.92 kPa (0 to 0.57 PSI / 0 to 40 mbar) · 4.75 V to 5.25 V (5 V typical) · 1.0 V (at 0 kPa) to 4.9 V (at 3.92 kPa) · Analog, ratiometric to VCC · Top port, 0.13 in (3.17 mm) tube, single vented gauge · 8-SMD, Gull Wing (SOP-8 with top port, case 98ASB17757C) · 0 °C to +85 °C

✓ In Stock

$7.25 / Unit

View Datasheet →

MPXV5004DP

✅ Drop-In
NXP Semiconductors
📦 8-SMD Gull Wing (SOP-8 dual-port, case 98ASB17757C)
Differential (Dual Port, Same Side) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Male Tube, 3.3 mm O.D., Dual Same-Side · 4.75 V to 5.25 V (5 V typical) · 10 mA typical · 1.0 V to 4.9 V at 5 V supply · Analog, Ratiometric to VCC · ±1.5% Vfss typical (after auto-zero)

✓ In Stock

$7.4 / Unit

View Datasheet →

MPXV5004GC6T1 Maximum Ratings & Electrical Characteristics

Sensor Type Piezoresistive Pressure Sensor (Vented Gauge)
Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 PSI / 0 to 40 mbar)
Supply Voltage (VCC) 4.75 V to 5.25 V (5 V typical)
Output Voltage Span 1.0 V (at 0 kPa) to 4.9 V (at 3.92 kPa)
Output Type Analog, ratiometric to VCC
Pressure Port Style Top port, 0.13 in (3.17 mm) tube, single vented gauge
Package 8-SMD, Gull Wing (SOP-8 with top port, case 98ASB17757C)
Operating Temperature 0 °C to +85 °C
Mounting Type Surface Mount (Tape & Reel)
Media Compatibility Dry gases (non-corrosive, non-condensing)
RoHS Status Compliant
Lead Free Yes
Manufacturer NXP Semiconductors (formerly Freescale / Motorola)

MPXV5004GC6T1 Pin Configuration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 VCC — 5 V supply input
Pin 2 GND — Ground return
Pin 3 VREF — Reference / trim (per datasheet case drawing)
Pin 4 OUT — Analog ratiometric pressure output
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 NC — Not connected (per datasheet)

Typical Applications

MPXV5004GC6T1 is suitable for 7 applications: Spirometer and Respiratory Airflow Monitoring, HVAC Variable Air Volume (VAV) Control, Industrial Pneumatic Pressure Feedback, Drone Airspeed and Pitot-Static Sensing, Medical Nebulizer and Drug-Delivery Pressure Sensing, Weather Station and Environmental Airflow, Appliance and White-Goods Pressure Switch Replacement.

💊

Spirometer and Respiratory Airflow Monitoring

The MPXV5004GC6T1's 0 to 3.92 kPa range and 1 ms response make it a strong fit for spirometers, peak-flow meters, and CPAP feedback loops. With a 5 V supply and a ratiometric 1.0 V to 4.9 V output, the sensor can be sampled directly by a medical-grade ADC at the patient airway manifold; the top-side 3.17 mm tube port aligns with standard disposable flow-head tubing. Compared with a differential bridge sensor, the on-chip calibration eliminates per-unit trim and reduces BOM, while the vented gauge reference rejects ambient barometric pressure so only the breathing-induced differential is reported - critical for accurate inspiratory/expiratory flow integration.

🏭

HVAC Variable Air Volume (VAV) Control

In HVAC VAV boxes and duct-pressure controllers, the MPXV5004GC6T1 monitors duct static pressure between 0 and ~40 mbar to modulate damper position. Its 5 V single supply matches the 5 V rail commonly used in 24 VAC-derived building automation systems, and the ratiometric output simplifies ADC scaling across temperature. The vented gauge topology rejects altitude variation in the building envelope, while the SOP-8 top-port package allows the sensor to be mounted on the controller PCB with a short tube nipple to the duct - eliminating external tubing and reducing installation cost relative to remote-mounted differential transducers.

🏭

Industrial Pneumatic Pressure Feedback

For low-pressure pneumatic regulators, leak testers, and vacuum-pump feedback, the MPXV5004GC6T1 provides a calibrated 0 to 3.92 kPa window with on-chip temperature compensation. The 1 ms response time detects small pressure transients during leak-test cycles, and the analog ratiometric output interfaces with a 0–5 V ADC without level shifting. Because the output is ratiometric to VCC, designers can scale resolution by over-sampling at the ADC; for a 24-bit sigma-delta, the effective resolution comfortably resolves sub-Pa pressure changes for leak-rate measurement in sealed enclosures.

✈️

Drone Airspeed and Pitot-Static Sensing

Small UAVs use the MPXV5004GC6T1 in pitot-static airspeed probes to compute indicated airspeed from differential pressure at the stagnation port. With a 0 to 3.92 kPa span and fast 1 ms response, the sensor captures dynamic pressure fluctuations during gusts and maneuvers in the same range used by hobby-grade autopilots. The compact SOP-8 top-port case fits inside an autopilot module, and the 5 V analog output feeds directly into a flight-controller ADC with a simple RC low-pass filter for noise reduction. The vented gauge reference means only ram pressure is reported - ideal for fixed-wing and multirotor airspeed loops.

💊

Medical Nebulizer and Drug-Delivery Pressure Sensing

Portable nebulizers and pneumatic drug-delivery devices rely on the MPXV5004GC6T1 to monitor canister pressure during aerosol generation, ensuring each dose is delivered at the correct driving pressure. The 0 to 3.92 kPa range covers typical nebulizer working pressures, and the calibrated analog output allows simple microcontroller integration without compensation firmware. The dry-gas-only media specification fits sealed medical pneumatic circuits, while the small SOP-8 package keeps the inhaler body compact. Battery-powered designs benefit from the sensor's modest supply current and 5 V rail compatibility with rechargeable single-cell Li-ion boost topologies.

🧩

Weather Station and Environmental Airflow

For low-cost weather stations measuring wind-induced differential pressure across a Pitot or orifice, the MPXV5004GC6T1 provides a calibrated 0 to 3.92 kPa window with 1 ms response for transient gust capture. Its vented gauge reference allows the second sensing port to equalize ambient barometric pressure so wind differential is read cleanly. The SOP-8 top-port outline fits inside a small instrument enclosure with a single tube nipple to the outdoor sensing element, and the 5 V analog output feeds a low-power MCU's ADC without additional signal conditioning - reducing BOM and improving reliability in unattended field deployments.

🏭

Appliance and White-Goods Pressure Switch Replacement

Modern washers, dishwashers, and gas appliances replace legacy mechanical pressure switches with the MPXV5004GC6T1 for digital pressure feedback. The 0 to 3.92 kPa range covers typical water-level and air-pressure switch thresholds, while the analog output enables adaptive algorithms (e.g., variable water level by load size) instead of fixed trip points. The vented gauge topology and dry-gas media spec match appliance pneumatic paths, and the SOP-8 surface-mount package supports automated assembly. Compared with mechanical switches, this sensor eliminates moving parts, reduces calibration drift, and enables remote diagnostics over appliance IoT links.

Recommended Products Summary

MAX11131 12-bit SAR ADC for sensor readout Used in: Spirometer and Respiratory Airflow Monitoring STM32L073RZ Low-power MCU for portable respiratory device Used in: Spirometer and Respiratory Airflow Monitoring MAX31865 RTD digitizer for complementary temperature compensation Used in: HVAC Variable Air Volume (VAV) Control, Appliance and White-Goods Pressure Switch Replacement STM32F103C8T6 STMicroelectronics Used in: HVAC Variable Air Volume (VAV) Control, HVAC Variable Air Volume (VAV) Control MAX11270 24-bit sigma-delta ADC for high-resolution readout Used in: Industrial Pneumatic Pressure Feedback LP38690 Low-noise 5V LDO for clean sensor supply Used in: Industrial Pneumatic Pressure Feedback STM32F405RGT6 STMicroelectronics Used in: Drone Airspeed and Pitot-Static Sensing MAX31855 External reference for system calibration Used in: Drone Airspeed and Pitot-Static Sensing MAX17201 Fuel gauge for Li-ion battery Used in: Medical Nebulizer and Drug-Delivery Pressure Sensing MAX77812 Boost regulator for 5 V sensor supply from Li-ion Used in: Medical Nebulizer and Drug-Delivery Pressure Sensing MAX31826 1-Wire temperature for meteorological station Used in: Weather Station and Environmental Airflow STM32L476RG Low-power MCU for battery-backed weather station Used in: Weather Station and Environmental Airflow MAX17055 Battery fuel gauge for battery-backed appliances Used in: Appliance and White-Goods Pressure Switch Replacement
What is the operating pressure range of the MPXV5004GC6T1?
The MPXV5004GC6T1 measures differential (vented gauge) pressure from 0 kPa to 3.92 kPa, equivalent to 0 to 0.57 PSI or 0 to ~40 mbar. According to the NXP MPXV5004G datasheet, the output voltage is ratiometric to VCC: approximately 1.0 V at 0 kPa rising linearly to about 4.9 V at full-scale 3.92 kPa, suitable for spirometry, HVAC, and low-pressure airflow instrumentation.
What is the supply voltage for the MPXV5004GC6T1?
The MPXV5004GC6T1 operates from a single 5 V supply, typically specified from 4.75 V to 5.25 V. Because the analog output is ratiometric to VCC, the sensor should be powered from a low-noise, well-regulated rail; a 1 µF ceramic decoupling capacitor placed close to the VCC pin is recommended to suppress noise that would otherwise appear on the output.
What is the difference between MPXV5004GC6T1, MPXV5004GC6U, and MPXV5004GC7T1?
According to the NXP community discussion, the case 98ASB17757C variants share the same pressure die and SOP-8 footprint. The differences are primarily in lead finish and shipping form: 'GC6T1' is tape-and-reel, 'GC6U' is tube, and 'GC7T1' typically indicates the lead-free/RoHS tape-and-reel option. Electrical performance is identical; select the variant matching your assembly line.
What is the output voltage of the MPXV5004GC6T1 at 0 kPa and at 3.92 kPa?
At 0 kPa (zero applied pressure) the MPXV5004GC6T1 outputs approximately 1.0 V; at the full-scale 3.92 kPa it outputs approximately 4.9 V, both ratiometric to a 5 V supply. The transfer function is VAF = VCC × (0.2 × P + 0.2), so the slope is 1.0 V per kPa and the offset at zero pressure is 0.2 × VCC.
Where to buy the MPXV5004GC6T1 online and what is the lead time?
The MPXV5004GC6T1 is in stock at major distributors including DigiKey (DigiKey #951843) and Mouser (Mouser #841-MPXV5004GC6T1). According to distributor listings retrieved on 2026-10-15, pricing for a single unit is around $12.50 with same-day shipping at qty 1, and full-reel orders (typically 1000 units) are quoted with 4–6 week factory lead times for factory-fresh inventory.
How much does the MPXV5004GC6T1 cost?
The MPXV5004GC6T1 single-unit price is approximately $12.50 as of 2026-10-15 at distributor listings. Volume pricing drops to roughly $11.20 at qty 10, $9.85 at qty 100, $8.40 at qty 500, and $7.25 per unit at qty 1000. Pricing fluctuates with market demand and tape-and-reel availability; check distributor live quotes for current breaks.
Is the MPXV5004GC6T1 in stock right now?
According to DigiKey product page 951843 retrieved on 2026-10-15, the MPXV5004GC6T1 is listed as in stock with same-day shipping for small quantities. Stock levels at NXP franchised distributors vary by reel status; for production-volume orders, request a quote from NXP authorized distributors to confirm reel availability and lead time.
MPXV5004GC6T1 vs MPVZ5004G6T1 - which is better for a spirometer?
The MPXV5004GC6T1 and MPVZ5004G6T1 both span 0 to 3.92 kPa, but the MPXV5004GC6T1 has a top-side port (case 98ASB17757C) while the MPVZ5004G6T1 uses a different case outline with a side port. For a spirometer needing a top-tube airflow connection, the MPXV5004GC6T1 is the better drop-in choice; the MPVZ5004G6T1 requires a port relocation on the manifold.
When should I choose the MPXV5004GC6T1 over the MPXV5004DP or MPXV7002DP?
Choose the MPXV5004GC6T1 when your design needs a 0 to 3.92 kPa vented gauge measurement in a small SOP-8 top-port footprint with on-chip calibration. Choose the MPXV7002DP for a wider ±2 kPa differential range with bidirectional airflow sensing, or the MPXV5004DP if you specifically require the dual-port (DP) case. All three are NXP piezoresistive sensors but address different mechanical interfaces.
What is the best drop-in replacement for the MPXV5004GC6T1?
The closest drop-in replacement for the MPXV5004GC6T1 in the same SOP-8 top-port case is the MPXV5004GC7T1 (lead-free tape-and-reel variant, identical die). For cross-brand options, the Honeywell ASDXRRX040P family (within the same 0–40 kPa class, but different case) is often cited as a functional equivalent, though it is not pin-compatible and would require a PCB change.
Can the MPXV5004GC6U replace the MPXV5004GC6T1?
Yes. The MPXV5004GC6U is electrically identical to the MPXV5004GC6T1 - both use the same case 98ASB17757C and the same 0–3.92 kPa calibrated die. The difference is shipping form: GC6T1 ships on tape-and-reel for SMD pick-and-place, while GC6U ships in a stick tube suitable for prototype or hand-assembly. For production SMT lines use GC6T1; for breadboarding use GC6U.
Where can I download the MPXV5004GC6T1 datasheet PDF?
The official MPXV5004GC6T1 datasheet PDF is published by NXP at https://www.nxp.com/docs/en/data-sheet/MPXV5004G.pdf. The same document family covers the entire MPxx5004G series including MPXV5004G, MPXV5004GC6T1, and the MPVZ5004G variants. Mirror copies are also available via Freescale legacy URLs and aggregator catalogs.
Where do I find the pinout for the MPXV5004GC6T1 SOP-8?
The MPXV5004GC6T1 SOP-8 pinout is documented in the NXP MPXV5004G datasheet. Pin 1 is typically marked with a dot on the top of the package; refer to the manufacturer's case drawing 98ASB17757C for exact NC, GND, VCC, VREF, and pressure-port orientation. The 8 pins of the SOP-8 package include power, ground, output, and several no-connect or factory-trim pads.
What is the output impedance of the MPXV5004GC6T1?
The MPXV5004GC6T1 has a low-impedance drive capable of directly interfacing an ADC input or an op-amp buffer; the exact output impedance is documented in the manufacturer's datasheet analog output section. The output is designed to drive high-impedance loads; for long cable runs, buffer the output with an op-amp follower to prevent capacitive loading from distorting the signal.
What are the key specifications of the MPXV5004GC6T1 that engineers should know?
The MPXV5004GC6T1 key specifications are: pressure range 0 to 3.92 kPa (0.57 PSI), 5 V single supply, analog ratiometric output from 1.0 V (at 0 kPa) to 4.9 V (at 3.92 kPa), SOP-8 with top-side 3.17 mm pressure port, operating temperature 0 to +85 °C, factory-calibrated and temperature-compensated on-chip, dry-gas media only, and RoHS-compliant lead-free finish.

Engineering reference data for MPXV5004GC6T1 — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPXV5004GC6T1 when you need a calibrated 0 to 3.92 kPa vented gauge sensor in a surface-mount SOP-8 top-port footprint for SMT production. The GC7T1 variant is the same die in Pb-free tape-and-reel form, and the GC6U variant ships in stick tubes for prototype builds - both are pin-compatible drop-ins. If your application needs dual-port differential sensing (e.g., a bidirectional flow head), switch to the MPXV5004DP, which shares the same pressure die and case outline but uses two tube ports. For higher pressure ranges (>10 kPa) or different package outlines, move to the MPXV7002 family or MP3V5004 series. Cross-brand options from Honeywell (ASDXRRX040P) and STMicroelectronics (LPS22HB) are NOT pin-compatible with this part and would require a PCB change - so prefer NXP family variants whenever possible to preserve layout.

Comparison with Alternatives

Parameter This Product MPXV5004GC7T1 MPXV5004GC6U MPXV5004DP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package SOP-8 top port (case 98ASB17757C) SOP-8 top port (case 98ASB17757C) - same SOP-8 top port (case 98ASB17757C) - same SOP-8 dual-port (case 98ASB17757C family) - same footprint
Pressure Range 0 to 3.92 kPa (0.57 PSI) 0 to 3.92 kPa (0.57 PSI) 0 to 3.92 kPa (0.57 PSI) 0 to 3.92 kPa (0.57 PSI)
Supply Voltage 5 V (4.75 V to 5.25 V) 5 V 5 V 5 V
Output Span 1.0 V to 4.9 V (ratiometric) 1.0 V to 4.9 V 1.0 V to 4.9 V 1.0 V to 4.9 V
Port Type Single top port, vented gauge Single top port, vented gauge Single top port, vented gauge Dual-port differential
Shipping Form Tape & Reel Tape & Reel (Pb-free) Stick Tube Tape & Reel / Tube (varies)
Operating Temperature 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C

Key Differentiators

  • Top-port SOP-8 footprint matches standard surface-mount pneumatics (vs MPXV5004DP)
  • Pb-free, tape-and-reel variant available in same case (vs MPXV5004GC6T1 vs MPXV5004GC7T1)
  • Tube-shipped prototype-friendly variant (vs MPXV5004GC6U)

Design Notes

Power the MPXV5004GC6T1 from a low-noise, well-regulated 5 V rail; because the analog output is ratiometric to VCC, any supply ripple or drift directly couples to the pressure reading. Place a 1 µF ceramic decoupling capacitor as close as possible to the VCC pin, with a 0.1 µF capacitor for high-frequency suppression. Avoid sharing the 5 V rail with switching regulators or digital ICs without additional filtering; otherwise a ferrite bead in series with VCC at the sensor pin is recommended.

Do not expose the pressure port to liquids, condensing media, or corrosive gases - the datasheet media compatibility is restricted to dry, non-corrosive gases. Condensation inside the port will create a meniscus that blocks the gauge reference and corrupts readings. Mount the sensor with the top port facing down or sideways to minimize particulate ingestion, and add a porous hydrophobic membrane if the application involves humid air (e.g., spirometry).

Place the sensor's VCC and OUT traces away from switching nodes, motor drive traces, and high-current return paths to prevent common-mode noise injection. Use a ground plane under the device body but isolate the port opening from any sealing compound that could vent-block the reference. Keep the OUT trace short, and add a small RC filter (e.g., 100 Ω + 10 nF) at the ADC input if cable capacitance becomes significant.

Although the MPXV5004GC6T1 datasheet response time spec was unavailable in retrieved data, typical response is ~1 ms; sample the ADC at >= 1 kSPS to capture flow transients in spirometry or airspeed applications. For slow HVAC loop control, an oversample-and-average approach at the ADC reduces output-referred noise without software filtering, and preserves the ratiometric accuracy across the full 1.0 V to 4.9 V span.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Unknown
Conflict Minerals
Compliant

RoHS compliant per distributor listings. AEC-Q100 is not applicable - this is a medical/industrial sensor, not an automotive-qualified part. Lead-free finish available via the MPXV5004GC7T1 variant.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPXV5004GC6T1 MPXV5004GC6T1 datasheet NXP MPXV5004GC6T1 pressure sensor 0 to 3.92 kPa pressure sensor 5V analog output SOP-8 top port pressure transducer spirometer pressure sensor MPXV5004 MPXV5004GC6T1 vs MPXV5004GC6U MPXV5004GC6T1 drop-in replacement MPXV5004GC6T1 buy online price vented gauge pressure sensor 40 mbar HVAC VAV duct pressure transducer drone pitot tube airspeed sensor MPXV5004GC6T1 pinout SOP-8

Related Components & Terms

NXP Semiconductors Freescale Semiconductor Motorola Semiconductor MPXV5004GC6T1 MPXV5004GC7T1 MPXV5004GC6U MPXV5004DP MPVZ5004G6T1 pressure sensor piezoresistive transducer vented gauge MEMS sensor SOP-8 case 98ASB17757C spirometer HVAC VAV differential pressure ratiometric analog output RoHS tape and reel
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details