SI3068-B-FT - Integrated V.92 DAA Interface IC | Skyworks
料号: SI3068-B-FT ✗ 停产SI3068-B-FT 概述
A direct access arrangement is the line-side interface between a telephone network and a data-processing system. In this product category, the DAA integrates functions that might otherwise require a discrete analog front end, isolation transformer, relays, optoisolator, and a two-wire-to-four-wire hybrid. The SI3068-B-FT is therefore positioned as a compact interface IC for modem and system-side communication equipment rather than as a general-purpose signal-processing device.
The principal feature is integration of the V.92-quality codec with DC termination, AC termination, and the hybrid circuitry. This integration reduces the number of external line-interface components required by a system-side DAA implementation. The 10-pin MSOP format supports compact surface-mount layouts, while the 9 mA supply current provides a defined operating point for power-budget analysis in line-powered and powered communication equipment.
The SI3068-B-FT belongs to a specialized telecom-interface family whose architecture targets compact system-side modules. Its design consolidates the codec and hybrid-related functions into one IC, supporting manufacturers that want to reduce board area and component count. Because the integration changes the external design requirements, layouts should be based on the pin-description table, recommended application circuit, and decoupling guidance in the manufacturer datasheet rather than on generic analog-layout assumptions.
Typical uses include V.92 modem hardware, system-side DAA modules, telephone-line data equipment, central-office line-card interfaces, and compact embedded communications platforms. In these systems, the IC can serve as the central line-side interface when the host processor or modem subsystem requires a compact integrated DAA rather than discrete termination and hybrid components.
Designers should verify the exact pin assignments, external component requirements, operating voltage, clocking method, line-side impedance settings, and temperature limits in the manufacturer datasheet before layout release. The 10-MSOP package has a narrow pin pitch, so land-pattern accuracy, solder-paste control, and careful routing around high-impedance line-interface nodes are important. Tube packaging should also be handled according to the manufacturer’s moisture-sensitivity and reflow requirements.
This product record combines the SI3068-B-FT ordering information, manufacturer datasheet, package data, lifecycle indication, replacement analysis, and application guidance into an engineering-focused resource. It helps designers distinguish the tube-packaged FT ordering code from related FS and FTR variants while focusing attention on the verified V.92 DAA function, 9 mA supply current, and 10-MSOP implementation.
直接替换替代料: SI3068-B-FT ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
SI3068-B-FTR
✅ 直接替换📋 参考替代料(不在目录中)
SI3068-B-FS
✅ 直接替换📋 参考替代料(不在目录中)
SI3068-B-FT 规格参数
| Product Type | Integrated direct access arrangement (DAA) interface IC |
| Codec Standard | V.92 quality |
| DC Termination | Integrated |
| AC Termination | Integrated |
| Hybrid Circuitry | Integrated |
| 电源电流 | 9 mA |
| Number of Circuits | 1 circuit |
| 封装 | 10-MSOP, 0.118 inch width, 3.00 mm width |
| Alternate Package Designation | 10-TFSOP |
| 安装类型 | Surface Mount (SMT) |
| Packaging Type | Tube |
| Standard Package Quantity | 50 units |
| RoHS 状态 | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | not_applicable |
SI3068-B-FT 50 units 引脚配置指南
SI3068-B-FT(50 units 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: SI3068-B-FT.
请参阅 数据手册 以查看完整引脚配置。
典型应用
SI3068-B-FT 适用于 6 应用s: V.92 System-Side Modem, Central-Office Line Card, Telephone-Line Data Terminal, Embedded Communications Platform, Industrial Telemetry Gateway, Network Voice Adapter.
V.92 System-Side Modem
The SI3068-B-FT fits a V.92 system-side modem because the manufacturer identifies a V.92-quality codec, DC termination, AC termination, and integrated hybrid in one 10-MSOP device. This consolidates the principal line-interface functions into one IC and can reduce the board area occupied by discrete termination, transformer-interface, and analog-front-end circuitry. The defined 9 mA supply current also provides a concrete starting point for the modem’s power budget. Implementers should reproduce the manufacturer application circuit, external line-network values, and decoupling arrangement to preserve signal and ringing behavior.
推荐
Central-Office Line Card
A central-office line card can use the SI3068-B-FT where each channel requires an integrated voice-band line interface rather than a collection of discrete termination and hybrid components. The single-circuit 10-MSOP implementation supports compact channel layouts, while the V.92-quality codec provides a defined modulation path. Its 9 mA operating supply current is useful when estimating thermal load across many channels. Before production, verify the card’s line impedance, protection network, isolation boundary, clocking, and exact pin assignments against the manufacturer datasheet.
推荐
Telephone-Line Data Terminal
The SI3068-B-FT is suitable for a telephone-line data terminal that needs a compact V.92-quality line-side DAA. Integrating the codec, DC termination, AC termination, and hybrid reduces the number of separate line-interface blocks and can shorten the path between the analog line and the modem logic. The 10-MSOP package allows the interface to be placed close to the line-network components, which is valuable in compact terminal designs. Use the specified 9 mA supply condition as the electrical baseline and follow the manufacturer layout for all sensitive nodes.
推荐
Embedded Communications Platform
An embedded communications platform can place the SI3068-B-FT beside a host processor or modem controller when a standardized V.92 line interface is required. The 10-MSOP package provides a manageable surface-mount footprint, and the integrated hybrid and termination functions allow the design to avoid a larger discrete analog front end. Because the device is listed as obsolete, engineers should first confirm lifecycle availability and the suitability of the exact ordering code. The 9 mA supply current and 10-pin layout should be included in the platform’s thermal and PCB planning.
推荐
Industrial Telemetry Gateway
A legacy industrial telemetry gateway can use the SI3068-B-FT when its modem still relies on a V.92-quality telephone-line interface. The integration of the codec and termination circuitry reduces maintenance complexity compared with a board containing many discrete line-interface components. The 10-MSOP format also allows replacement within an existing compact design if the land pattern and pinout match. Because lifecycle status is obsolete, validate the operating temperature, supply voltage, and external component values before approving the part for sustained industrial use.
推荐
Network Voice Adapter
The SI3068-B-FT can support a dedicated network voice adapter that bridges a telephone line and digital processing circuitry. Its V.92-quality codec provides the voice-band conversion function, while integrated DC termination, AC termination, and hybrid circuitry simplify the line-side front end. The 9 mA operating supply current allows engineers to estimate the adapter’s contribution to the overall power envelope. Reproduce the manufacturer’s recommended network and component values, and treat the obsolete designation as a production-risk item requiring explicit lifecycle approval.
推荐
推荐产品汇总
工程参考数据: SI3068-B-FT ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | SI3068-B-FTR | SI3068-B-FS |
|---|---|---|---|
| Package | 10-MSOP | 10-MSOP | 10-MSOP |
| Brand | Skyworks Solutions | Skyworks Solutions | Skyworks Solutions |
| Device Function | Integrated V.92-quality DAA | Integrated V.92-quality DAA | FCC+ embedded DAA |
| DC Termination | Integrated | Integrated | Integrated |
| AC Termination | Integrated | Integrated | Integrated |
| Hybrid Circuitry | Integrated | Integrated | Integrated |
关键差异点
- Integration reduces the required discrete line-interface blocks (对比 SI3068-B-FS)
- Direct tube-packaged ordering configuration (对比 SI3068-B-FTR)
- Defined low operating supply current (对比 SI3068-B-FS)
设计说明
Use the manufacturer’s 10-MSOP land pattern and place the required external network components close to their associated pins. Keep sensitive line-side and hybrid nodes short, avoid unnecessary copper extensions, and route return-current paths continuously to the device ground reference. Confirm the pin-description table before assigning tracks because the public listing confirms the package but does not provide a complete numbered pin map.
Do not substitute only on the basis of the SI3068 family name. Confirm the suffix-specific package, operating voltage, temperature grade, pin mapping, and external component values before using SI3068-B-FS as a replacement. The FT and FTR codes identify different shipping formats, with FT supplied in a tube and FTR supplied on tape and reel, so production automation and moisture-handling requirements can differ.
Budget the SI3068-B-FT from its stated 9 mA operating supply current and apply the actual system supply voltage to calculate device power. Estimated: P = 9 mA × VIN; for example, a 3.3 V rail produces 29.7 mW if the device operates at that voltage. Confirm the permitted supply range and operating mode in the manufacturer datasheet before using this estimate as a design limit.
Treat the codec, termination, and hybrid sections as one coordinated line-interface subsystem. Preserve the recommended component values and placement because changing termination balance can alter line impedance, return loss, or codec performance. If the PCB differs from the reference design, validate the interface with line-network measurements and compare voice-band operation across worst-case line conditions.
合规信息
The device is a telecom interface IC rather than an automotive component. No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact ordering code.