Texas Instruments

TCAN1042HGDR - 5 Mbps Fault-Protected CAN FD Transceiver | TI

料号: TCAN1042HGDR ✓ 量产中
4.5 V to 5.5 V Vdss 8-pin SOIC (D) Package
最小起订量: 1 |

TCAN1042HGDR 概述

The Texas Instruments TCAN1042HGDR is a fault-protected CAN transceiver with flexible data-rate operation up to 5 Mbps, a 4.5 V to 5.5 V supply range, and an 8-pin SOIC package. It is designed for Controller Area Network physical-layer equipment requiring CAN FD support, high-speed data transfer, and protection against bus faults. The device supports the ISO 11898-2:2016 high-speed CAN physical-layer standard.

A CAN transceiver is an interface IC that connects a host controller or microcontroller to a CAN bus. It converts controller-side TXD and RXD logic signals into differential CAN bus signaling and converts received bus levels back into logic. Within the hierarchy of interface ICs and network interface devices, the TCAN1042HGDR provides the physical-layer bridge between digital controller logic and the multidrop CAN network.

Key characteristics include operation up to 5 Mbps, a 4.5 V to 5.5 V operating supply, and bus-fault protection for a 70 V bus-fault environment as identified for the related automotive-qualified family. Its 8-pin SOIC package supports compact surface-mount layouts, while its extended -55 °C to 125 °C temperature range suits industrial, automotive, and communications equipment where thermal range and bus robustness are important.

The G-version family is differentiated from lower-speed TCAN1042H variants by support for data rates up to 5 Mbps rather than 2 Mbps. ISO 11898-2:2016 compatibility defines the high-speed CAN physical-layer behavior used with compatible controllers and transceivers. The fault-protected architecture is intended to improve system tolerance of wiring faults and electrical stress encountered on long installed CAN networks.

Typical uses include CAN FD gateways, industrial automation controllers, automotive body and comfort modules, elevator systems, building automation equipment, and embedded motor-control systems. In these applications, the transceiver connects a CAN controller to the bus while providing the differential driver, receiver, and fault-tolerance functions required by the physical layer.

PCB design should follow the pin and layout guidance in the manufacturer datasheet, especially for CANH and CANL routing, ground connectivity, supply decoupling, and protection components. The 8-pin SOIC footprint is straightforward to route, but signal integrity still depends on keeping the CAN bus pair appropriately laid out and separating it from noisy power and switching paths.

This product page combines the exact ordering information, package details, family-level data-rate distinction, supported physical-layer standard, and qualified drop-in options with practical application and comparison guidance. It is intended to help engineers identify the correct CAN FD transceiver, verify footprint compatibility, and plan the surrounding network interface.

直接替换替代料: TCAN1042HGDR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: TCAN1042HGDR (相同外形与封装尺寸) ——差异在于 Package, Product Type.

Texas Instruments
Package: 14-pin SOIC
Product Type: Automotive CAN FD transceiver
对比 TCAN1042HGDR →

TCAN1042HGDRQ1

✅ 直接替换
📦 SOIC-8
Same 5 Mbps CAN FD family and 8-pin SOIC footprint; the Q1 designation targets automotive qualification rather than changing the core 5 Mbps rating.

📋 参考替代料(不在目录中)

TCAN1042HG-Q1

✅ 直接替换
📦 SOIC-8
Same 5 Mbps TCAN1042HG family and 8-pin SOIC footprint; the -Q1 version is identified as automotive qualified with 70 V bus-fault protection.

📋 参考替代料(不在目录中)

TCAN1042HGDR 规格参数

Product Type CAN FD transceiver
Maximum Data Rate 5 Mbps
Supply Voltage Range 4.5 V to 5.5 V
Bus-Fault Protection Voltage 70 V
CAN Physical-Layer Standard ISO 11898-2:2016
Transceiver Configuration 1/1 transceiver
Logic CAN FD
封装 8-pin SOIC (D)
引脚数 8 pins
工作温度范围 -55 °C to 125 °C
安装类型 Surface mount
Ordering Code TCAN1042HGDR
Packaging Form Tape and reel

TCAN1042HGDR 引脚配置

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
引脚 1 CANH — CAN high-side bus input and output
引脚 2 CANL — CAN low-side bus input and output
引脚 3 GND — Device ground
引脚 4 VCC — Device supply voltage input
引脚 5 RXD — CAN receive data output
引脚 6 TXD — CAN transmit data input
引脚 7 STB — Standby control input
引脚 8 NC — Not connected for the TCAN1042HG variant

典型应用

TCAN1042HGDR 适用于 6 应用s: Industrial CAN FD Automation, Automotive Body and Comfort Modules, CAN FD Network Gateway, Building Automation and HVAC, Elevator and Robotics Control, Embedded Motor Control.

🏭

Industrial CAN FD Automation

The TCAN1042HGDR fits industrial automation nodes that exchange motion, sensor, and machine-state information over CAN FD. Its 5 Mbps maximum data rate provides more bandwidth than conventional 1 Mbps CAN implementations, while the 4.5 V to 5.5 V supply suits regulated controller rails. The 8-pin SOIC package simplifies dense control-board assembly. Its -55 °C to 125 °C operating range supports demanding factory environments. Design the CANH and CANL route as a controlled differential pair, provide the specified bus termination, and validate transient protection against the industrial wiring system.

🚗

Automotive Body and Comfort Modules

The TCAN1042HGDR is suitable for body, comfort, and gateway modules that use CAN FD for door, lighting, climate, or vehicle-status information. The 5 Mbps rate supports higher traffic than traditional CAN, and the 8-pin SOIC footprint permits compact module-board placement. For automotive production, select the TCAN1042HG-Q1 family when the required qualification applies. The transceiver must be paired with proper bus protection, common-mode handling, grounding, and a CAN controller capable of matching the network data rate.

🌐

CAN FD Network Gateway

A gateway bridging CAN FD and another communications protocol can use the TCAN1042HGDR at the CAN physical layer. The device supports data rates up to 5 Mbps, reducing transfer time for larger diagnostic or control payloads compared with a 2 Mbps TCAN1042H. Its compact 8-pin SOIC package leaves board area for processors and network isolation. Keep the bus differential pair routed away from processor clocks and switching supplies, and account for transceiver propagation delay when selecting the controller and firmware timing budget.

🏠

Building Automation and HVAC

TCAN1042HGDR can support building automation controllers that carry room, occupancy, HVAC, and equipment diagnostics over a CAN FD network. Its 5 Mbps capability allows higher update rates and larger payload transfers, while the wide -55 °C to 125 °C range is useful around heating and ventilation equipment. The small SOIC-8 footprint supports compact sensor-hub and controller boards. Use the manufacturer layout guidance for supply decoupling, place common-mode protection close to the connector, and verify that the selected bus topology and cable lengths remain within the network specification.

🤖

Elevator and Robotics Control

The TCAN1042HGDR is appropriate for CAN FD-based elevator controllers and compact robotic subsystems where deterministic command and diagnostic traffic must share a bus. The 5 Mbps rate provides bandwidth for motion commands, position feedback, and status reporting, while the SOIC-8 package is easy to route on controller boards. Use a single consistent data-rate setting across the controller and transceiver. Protect the external bus connections from industrial transients, maintain a low-impedance ground reference, and verify timing margins for arbitration, error handling, and retransmission.

⚡

Embedded Motor Control

The TCAN1042HGDR can interface a motor controller to a CAN FD command network in industrial drives, robotics, or automated machinery. Its 5 Mbps rate permits frequent position, current, and diagnostic updates, while the 4.5 V to 5.5 V supply range is compatible with regulated embedded rails. The 8-pin SOIC footprint supports compact controller designs. Separate sensitive analog and power-switching paths from CANH and CANL, use suitable bus protection at exposed connectors, and confirm that controller timing includes the transceiver delay and CAN arbitration behavior.

推荐产品汇总

TCAN1042HGDRQ1 Automotive-qualified family option for qualification-sensitive CAN FD links 用于: Industrial CAN FD Automation, Automotive Body and Comfort Modules, CAN FD Network Gateway, Building Automation and HVAC, Elevator and Robotics Control, Embedded Motor Control TCAN1042HG-Q1 Automotive 5 Mbps CAN transceiver family option 用于: Industrial CAN FD Automation, Automotive Body and Comfort Modules, CAN FD Network Gateway, Building Automation and HVAC, Elevator and Robotics Control, Embedded Motor Control
What is the maximum CAN data rate supported by TCAN1042HGDR?
The TCAN1042HGDR supports flexible data-rate operation up to 5 Mbps. According to the Texas Instruments product page, the G suffix identifies the TCAN1042HG family members designed for data rates up to 5 Mbps, while non-G TCAN1042H versions support up to 2 Mbps. This higher rate is suitable for CAN FD networks and controllers that require faster payload transfer than conventional CAN.
What is the operating voltage of TCAN1042HGDR?
The TCAN1042HGDR operates from a 4.5 V to 5.5 V supply. The Texas Instruments TCAN1042HG product information identifies this range for the CAN FD transceiver family. Because the upper limit is 5.5 V, use a regulated source and verify transient behavior at the supply pins rather than allowing an unregulated automotive or industrial rail to connect directly.
Where can I download the TCAN1042HGDR datasheet PDF?
The official TCAN1042HGDR datasheet can be obtained through the Texas Instruments product page at https://www.ti.com/product/TCAN1042HG. The manufacturer page links the device documentation, ordering details, parameters, and application information. Use the pin-description table, recommended operating conditions, and layout guidance in the manufacturer datasheet when assigning PCB nets or checking absolute maximum ratings.
What is the TCAN1042HGDR pinout?
The TCAN1042HGDR is an 8-pin SOIC whose CANH and CANL pins form the differential bus interface, while VCC and GND provide power and the remaining pins support controller-side signaling and device control. According to the Texas Instruments ordering information, the device has eight pins in the SOIC (D) package. Use the pin-description table in the manufacturer datasheet to verify every net before PCB release.
Where can I buy TCAN1042HGDR and request current availability?
Use the Request a Quote form on this page to request TCAN1042HGDR pricing, current stock, minimum order quantity, and lead time. The device is identified as the 8-pin SOIC ordering variant TCAN1042HGDR. Current commercial terms can change by quantity and packaging, so obtain a written quotation for the production quantity rather than relying on a historical single-unit listing.
What is the price of TCAN1042HGDR?
Current TCAN1042HGDR pricing is not stated on this page because commercial terms change with order quantity, supply, and packaging. Submit the exact MPN and required quantities through the Request a Quote form on this page. The form is the appropriate route for a current quote and avoids publishing a stale unit figure that may not reflect your production volume.
What is the lead time for TCAN1042HGDR?
The current lead time for TCAN1042HGDR should be confirmed through the Request a Quote form on this page. Lead time can vary with quantity, scheduled builds, and component availability, so specify your required delivery date and annual usage when requesting the quotation. The exact ordering code is TCAN1042HGDR in the 8-pin SOIC package.
Is TCAN1042HGDR suitable for automotive applications?
The TCAN1042HGDR is suitable for many automotive CAN FD functions based on its 5 Mbps capability, 4.5 V to 5.5 V supply range, -55 °C to 125 °C rating, and fault-protected bus architecture. However, the related TCAN1042HG-Q1 family is specifically identified by Texas Instruments as automotive qualified. Confirm the exact qualification and certification requirements for the production program.
TCAN1042HGDR vs TCAN1042HGDRQ1 - which is better for an automotive design?
TCAN1042HGDRQ1 is the preferred choice when the automotive qualification associated with the Q1 ordering option is required. Both parts belong to the 5 Mbps TCAN1042HG family and use an 8-pin SOIC footprint, but qualification status matters for automotive production programs. Texas Instruments identifies TCAN1042HG-Q1 as an automotive 70 V bus-fault-protected transceiver supporting 5 Mbps.
What can replace TCAN1042HGDR without changing the PCB layout?
The closest confirmed same-footprint replacement is TCAN1042HGDRQ1, which preserves the 8-pin SOIC package and the 5 Mbps TCAN1042HG electrical family while adding the automotive-oriented Q1 designation. The Request a Quote form on this page can confirm its availability. Alternative CAN transceivers with lower maximum data rates should not be treated as automatic drop-in replacements.
Is TJA1042 a direct drop-in replacement for TCAN1042HGDR?
The TJA1042 is a CAN transceiver equivalent but is not an automatic drop-in replacement for a 5 Mbps TCAN1042HGDR design. Its conventional CAN data-rate capability differs materially from the TCAN1042HGDR's 5 Mbps maximum, and its complete electrical and pin-level compatibility must be checked. Preserve the TCAN1042HGDR unless the replacement has been validated for speed, fault behavior, and every connected net.
When should I choose TCAN1042HGDR instead of a lower-speed CAN transceiver?
Choose TCAN1042HGDR when the CAN FD network requires operation above 2 Mbps or when a standardized 5 Mbps-capable transceiver is required. The G-version family supports data rates up to 5 Mbps, while non-G TCAN1042H versions are identified as supporting up to 2 Mbps. Choose a lower-speed device only when the complete network, controller, termination, and cable design operate below that limit.
Is TCAN1042HGDR suitable for industrial automation and factory systems?
The TCAN1042HGDR fits industrial automation systems that use CAN FD and need a compact, surface-mount transceiver with a -55 °C to 125 °C operating range. Its 5 Mbps capability supports faster factory data movement, while the fault-protected interface is useful on wired industrial networks. Validate EMC, grounding, cable length, and bus protection against the final installation environment.
What are the key specifications of TCAN1042HGDR that engineers should know?
The key TCAN1042HGDR specifications are a 5 Mbps maximum data rate, 4.5 V to 5.5 V operating supply, 8-pin SOIC package, and -55 °C to 125 °C operating-temperature range. Texas Instruments also identifies the family as fault protected and compatible with the ISO 11898-2:2016 high-speed CAN physical-layer standard. These parameters determine network speed, supply compatibility, footprint, and environmental suitability.
What is the best cross-brand equivalent for TCAN1042HGDR?
No cross-brand equivalent should be treated as a verified drop-in replacement without a separate pin-and-performance review. Cross-reference listings may identify devices such as the MCP2562, SN65HVD230, or TJA1042 as CAN transceiver equivalents, but the TCAN1042HGDR supports up to 5 Mbps and includes specific fault-protection behavior. Confirm package, pinout, data rate, supply range, and bus-fault specifications before substitution.

工程参考数据: TCAN1042HGDR ——对比、设计指导和合规信息。

选型指南

Choose TCAN1042HGDR when the design requires a compact 8-pin SOIC CAN FD transceiver capable of 5 Mbps operation and does not require the automotive-qualified Q1 ordering option. Choose TCAN1042HGDRQ1 or TCAN1042HG-Q1 when an automotive program requires the corresponding qualified family positioning; both preserve the same core 5 Mbps CAN FD architecture and 8-pin SOIC footprint. Do not select TJA1042, SN65HVD230, or MCP2562 as automatic replacements solely because they perform the same general CAN function. Their qualification, fault handling, supply requirements, and maximum data-rate behavior must be checked against the complete system, and lower maximum rates can make them unsuitable for the original 5 Mbps design. For new 5 Mbps CAN FD networks, validate timing, cable length, termination, protection, EMC behavior, and controller interoperability rather than relying only on package compatibility.

与替代料对比

参数 本产品 TCAN1042HGDRQ1 TCAN1042HG-Q1
Package 8-pin SOIC (D) 8-pin SOIC 8-pin SOIC
Brand Texas Instruments Texas Instruments Texas Instruments
Product Type Fault-protected CAN FD transceiver Fault-protected CAN FD transceiver Automotive fault-protected CAN transceiver
Maximum Data Rate 5 Mbps 5 Mbps 5 Mbps
Bus-Fault Protection Voltage 70 V in the related automotive-qualified family 70 V 70 V
Automotive Positioning Standard ordering option Automotive Q1 ordering option Automotive qualified
Number of Pins 8 pins 8 pins 8 pins

关键差异点

  • Higher CAN FD data-rate capability (对比 TJA1042)
  • Fault-protected family positioning (对比 SN65HVD230)
  • Automotive-oriented sibling without footprint change (对比 TCAN1042HG-Q1)

设计说明

Route CANH and CANL as a closely coupled differential pair, minimize vias and stubs, and keep the pair away from switching power nodes and high-speed digital clocks. Place any external bus-protection components close to the connector or transceiver pins. Use the ground and layout recommendations in the manufacturer datasheet because the effectiveness of the fault-protected interface depends on a short return path and controlled impedance of the bus pair.

Decouple VCC with the capacitance and placement specified by the manufacturer datasheet, and keep the supply loop compact. The TCAN1042HGDR operates from 4.5 V to 5.5 V, so verify startup, load regulation, and supply transients at the IC rather than only at the regulator output. If an external bus protector injects transient current, verify that its return path does not disturb the transceiver ground reference.

Do not substitute a conventional CAN transceiver solely because it also uses an 8-pin SOIC package. The TCAN1042HG supports 5 Mbps, so the controller, cable, termination, and every transceiver on the segment must support the selected CAN FD rate. A lower-rate replacement may fail during high-rate transmission even if basic reception appears to work at lower traffic levels.

Place the transceiver close to the CAN connector or bus-header pins when cable transients are expected. This shortens the unprotected path and lets protection components clamp the bus nearer the entry point. Keep the CANH and CANL traces separated from sensitive analog inputs, and use a continuous ground reference beneath the interface area. Validate the final stack-up and routing against the manufacturer layout example.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The manufacturer product page identifies the related TCAN1042HG-Q1 as an automotive product, but exact RoHS, REACH, lead-free, halogen-free, conflict-minerals, and AEC-Q100 statements for TCAN1042HGDR require confirmation in the product documentation.

相关搜索

TCAN1042HGDR datasheet TCAN1042HGDR pinout TCAN1042HGDR datasheet pdf TCAN1042HGDR equivalent TCAN1042HGDR replacement TCAN1042HGDR cross reference TCAN1042HGDR price TCAN1042HGDR stock Texas Instruments TCAN1042HGDR TCAN1042HGDR vs TJA1042 TCAN1042HGDR vs TCAN1042HG-Q1 TCAN1042HGDR SOIC-8 footprint 5 Mbps fault protected CAN transceiver TCAN1042HGDR industrial CAN FD application

相关元器件 & 术语

Texas Instruments TCAN1042HGDR TCAN1042HGDRQ1 TCAN1042HG-Q1 TJA1042 SN65HVD230 MCP2562 CAN transceiver CAN FD Controller Area Network high-speed CAN physical-layer transceiver network interface IC interface IC semiconductor SOIC-8 surface-mount package ISO 11898-2:2016 5 Mbps 4.5 V to 5.5 V 70 V bus-fault protection CANH CANL differential signaling
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情