TCAN1042VDQ1 - 2Mbps Automotive CAN FD | Texas Instruments
料号: TCAN1042VDQ1 ✓ 量产中TCAN1042VDQ1 概述
A CAN transceiver is the physical-layer interface between a CAN controller and a CAN bus. It converts controller logic levels into differential bus signals and receives differential bus signals back into digital data. As a member of the CAN FD-capable TCAN1042V-Q1 family, the TCAN1042VDQ1 combines automotive qualification features, flexible data-rate capability, bus fault tolerance, and an I/O level-shifting supply for flexible integration with automotive electronic control units.
The principal operating features include support for both CAN and CAN FD protocols, a maximum signaling rate of 2 Mbps, one CAN channel, a nominal 5 V supply, and an operating temperature range from -55 °C to 125 °C. The V-prefixed family also provides a secondary power-supply input for I/O level shifting, allowing the transceiver interface voltage to be adjusted independently from the primary supply. Normal and standby operating modes support low-power system behavior.
The device combines transmit, receive, bus-driver, bus-receiver, and fault-protection functions in one package. Its differential bus architecture supports communication with CAN controllers while protecting the interface against excessive bus voltage conditions. The reported bus-fault operating range extends from -58 V to 58 V, making the device appropriate for automotive environments where transient and fault conditions can exceed normal logic voltages.
Typical uses include body-control modules, powertrain controllers, electric-vehicle electronics, gateway units, engine-control modules, lighting controllers, and other ECUs connected to 2 Mbps CAN FD networks. The I/O level-shifting function is especially useful when a controller operates from a voltage different from the transceiver's primary 5 V supply, while fault protection improves robustness in electrically demanding vehicle networks.
PCB design should preserve the pin assignment specified in the manufacturer datasheet, place transceiver and bus-path components close to their relevant pins, and provide a low-impedance return path through the ground plane. The I/O supply and primary supply must meet their specified operating ranges, and external protection or filtering should be selected without unnecessarily degrading CAN edge rates or receiver sensitivity.
This page organizes the automotive CAN FD feature set, verified operating limits, package information, replacement comparisons, and practical integration guidance into one engineering-focused resource. It helps designers evaluate the TCAN1042VDQ1 for new 2 Mbps CAN FD designs or as a replacement candidate for an existing 8-pin SOIC implementation.
直接替换替代料: TCAN1042VDQ1 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: TCAN1042VDQ1 (相同外形与封装尺寸) ——差异在于 Package, Fault Protection, I/O Level Shifting, Maximum CAN FD Data Rate, Product Type.
TCAN1042HDRQ1
✅ 直接替换📋 参考替代料(不在目录中)
TCAN1042HGVDRBTQ1
✅ 直接替换📋 参考替代料(不在目录中)
TCAN1042HVDR
✅ 直接替换联系询价
查看数据手册 →TCAN1042VDRQ1
✅ 直接替换✓ 有现货
$0.33923 / 个
查看数据手册 →TCAN1042VDRBRQ1
✅ 直接替换📋 参考替代料(不在目录中)
TCAN1042VDQ1 规格参数
| Product Type | Automotive CAN FD transceiver |
| Protocol Support | CAN and CAN FD |
| Maximum Signaling Rate | 2 Mbps |
| CAN Channel Count | 1 channel |
| Primary Supply Voltage | 4.5 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| Bus Fault Voltage Range | -58 V to 58 V |
| 工作温度范围 | -55 °C to 125 °C |
| 封装 | 8-pin SOIC |
| 安装类型 | Surface mount |
| I/O Level Shifting | Supported through secondary power-supply input |
| Fault Protection | Automotive fault-protected bus interface |
| Operating Modes | Normal and standby |
| Automotive Classification | Automotive |
TCAN1042VDQ1 8-pin soic 引脚配置指南
TCAN1042VDQ1(8-pin soic 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: TCAN1042VDQ1.
请参阅 数据手册 以查看完整引脚配置。
典型应用
TCAN1042VDQ1 适用于 6 应用s: Automotive Body Control Modules, Powertrain and Engine Control, Electric Vehicle Network Gateway, Industrial CAN FD Control, Vehicle Lighting Controller, Diagnostic and Test Equipment.
Automotive Body Control Modules
The TCAN1042VDQ1 fits body-control modules that exchange commands and sensor data over a 2 Mbps CAN FD network. Its 1-channel CAN interface, 4.5 V to 5.5 V primary supply, and -55 °C to 125 °C operating range support harsh automotive environments. The V-series secondary I/O supply allows interface-level adjustment when the associated controller does not operate from the same logic voltage as the transceiver. Use the exact datasheet pin descriptions to connect CANH, CANL, supplies, ground, mode control, and receive output. Bus termination and protection components should remain compatible with 2 Mbps edge rates.
Powertrain and Engine Control
The TCAN1042VDQ1 is appropriate for powertrain controllers requiring a protected physical-layer link between a CAN controller and vehicle network wiring. Its fault-protected design and reported -58 V to 58 V bus-fault range add robustness against abnormal bus voltages, while the -55 °C to 125 °C rating covers temperature variation around the engine compartment. The transceiver supports CAN FD up to 2 Mbps for sensors, actuator commands, and diagnostic data. Keep the differential bus routing short, provide the specified termination, and use an uninterrupted ground reference so common-mode noise does not degrade signal quality.
Electric Vehicle Network Gateway
The TCAN1042VDQ1 can serve as the CAN physical-layer interface in an electric-vehicle gateway that coordinates battery, inverter, charger, and thermal-management controllers. CAN FD operation up to 2 Mbps supports the increased data volume associated with vehicle electrical systems, while the level-shifting supply permits interface-voltage coordination with a controller operating at a different logic level. Automotive fault protection is valuable in a gateway where harness transients and wiring faults are possible. The design should include common-mode choke or filtering only when its impedance and transient response remain suitable for the 2 Mbps bus configuration.
Industrial CAN FD Control
The TCAN1042VDQ1 can be used in industrial CAN FD control equipment whenever the specified automotive temperature range, fault tolerance, and standby operation provide a useful design margin. Its 2 Mbps signaling rate supports machine-control data exchanges, while the single-channel CAN interface keeps the implementation focused. The secondary I/O supply provides useful flexibility when the system controller and transceiver use different interface voltages. For industrial cabinets, maintain a low-impedance common ground and isolate external cabling where necessary. Validate the completed bus network at the intended baud rate because transceiver compatibility alone does not guarantee system-level timing performance.
Vehicle Lighting Controller
The TCAN1042VDQ1 fits lighting and body-electronics controllers that receive commands across a CAN FD network. A maximum signaling rate of 2 Mbps provides ample bandwidth for status, diagnostic, and lighting-control messages, while normal and standby modes help manage power state. The 8-pin SOIC package supports compact PCB layouts, although placement must follow the exact pin diagram and preserve a short CAN bus path. External bus protection should be selected to handle the vehicle electrical environment without increasing capacitive loading enough to degrade the specified 2 Mbps signaling performance.
Diagnostic and Test Equipment
The TCAN1042VDQ1 is suitable for vehicle diagnostic interfaces and CAN FD test equipment that needs a rugged 2 Mbps physical-layer connection. Its automotive fault protection, 5 V operating range, and extended temperature coverage make it appropriate for test equipment deployed in harsh environments. The I/O level-shifting supply can simplify interface arrangement with a controller using a different logic voltage. During bench validation, verify receiver output levels, standby-state behavior, propagation delay, and bus fault recovery using the manufacturer timing and test information. Avoid adding long unprotected cable stubs because they can create reflections at 2 Mbps.
工程参考数据: TCAN1042VDQ1 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | TCAN1042HDRQ1 | TCAN1042HGVDRBTQ1 | TCAN1042HVD | TCAN1042VDRQ1 | TCAN1042VDRBRQ1 |
|---|---|---|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Protocol | CAN, CAN FD | CAN, CAN FD | CAN, CAN FD | High-speed CAN | CAN, CAN FD | CAN, CAN FD |
关键差异点
- Provides V-series I/O level shifting in an automotive CAN FD interface (对比 TCAN1042HDRQ1)
- Matches the common 2 Mbps automotive CAN FD target (对比 TCAN1042HGVDRBTQ1)
- Uses a documented 8-pin SOIC footprint with automotive fault protection (对比 TCAN1042HVD)
- Matches the V-series electrical configuration (对比 TCAN1042HDRQ1)
设计说明
Place the transceiver close to the CANH and CANL connector or protection network, and route the differential pair as a tightly coupled pair with a continuous ground reference. Avoid routing the CAN bus beneath switching regulators, digital clocks, or other high-current paths. Keep the external protection and termination network close to the bus entry so parasitic inductance does not create additional edge-rate distortion.
Provide the primary 5 V rail and the V-series secondary I/O supply within their manufacturer-specified operating ranges, with local high-frequency bypass capacitance at the relevant pins. Confirm that the controller interface voltage and transceiver I/O level match before enabling the device. Sequencing matters in multi-rail automotive ECUs because powering the transceiver before its controller or receiving rail can create undefined interface conditions.
Do not select a candidate from package appearance alone. TCAN1042HDRQ1 omits the V-series level-shifting supply, while the G suffix used by TCAN1042HGVDRBTQ1 supports a higher signaling rate. Confirm exact pin functions, standby behavior, supply limits, bus-fault range, and package orientation against the manufacturer datasheet before treating any listed alternative as a drop-in production replacement.
Use the exact 8-pin SOIC pin configuration and observe the package orientation marker when assigning the CAN, supply, ground, mode-control, and receive-output connections. Keep the ground connection short and use a solid ground plane rather than a narrow thermal-relief route. Verify CAN bus timing, reflections, and common-mode margin after PCB assembly because schematic correctness alone does not guarantee compliance at 2 Mbps.
合规信息
The device is classified as automotive by Texas Instruments, but the exact TCAN1042VDQ1 RoHS, REACH, lead-free, halogen-free, conflict-minerals, and AEC-Q100 statements are not stated in the referenced product listings.