Texas Instruments

TCAN332DCNR - 3.3V 1Mbps CAN Transceiver | Texas Instruments

料号: TCAN332DCNR ✓ 量产中
3.0 V to 3.63 V Vdss 8-pin SOT-23 (DCN) Package
最小起订量: 1 |

TCAN332DCNR 概述

Texas Instruments TCAN332DCNR is a 3.3 V, 1 Mbps CAN FD transceiver with one CAN channel, available in an 8-pin SOT-23 (DCN) package. It operates from 3.0 V to 3.63 V across a -40°C to +125°C temperature range, combining classic CAN communication with CAN FD support in a compact surface-mount footprint.

A CAN transceiver is an interface IC that connects a host controller's digital logic to a differential CAN bus. Within the CAN interface hierarchy, the TCAN332 belongs to the physical-layer transceiver class, converting logic-level TXD and RXD signals into bus-level CANH and CANL signals and receiving bus data for the controller. Its 3.3 V supply operation suits modern embedded systems, while its low pin count assists compact industrial and automotive electronics designs.

Key features include support for CAN and CAN FD protocols, 1 Mbps maximum data rate, and receiver operation over common-mode input voltages from -2 V to 7 V. The TCAN332 family also provides low-power shutdown and standby operating modes for battery-powered or intermittently connected equipment. These characteristics make the device suitable where low supply voltage and compact packaging are more important than 5 V compatibility.

The device combines a CAN transmitter, CAN receiver, bus-driver protection, and digital interface functions in one package. Its DCN SOT-23 package reduces board area compared with larger SOIC options, although careful placement of input and bus components is important in systems with fast CAN edges or electrically noisy environments. The operating temperature range covers industrial temperature requirements from -40°C through +125°C.

Typical applications include industrial automation controllers, building automation nodes, battery-powered condition monitoring, electric-vehicle subsystems, robotics, and compact CAN-based sensor networks. The TCAN332DCNR is especially appropriate when the controller operates from a 3.3 V rail and the system requires CAN FD capability without a separate physical-layer transceiver.

Design with the manufacturer's recommended CAN bus protection and termination arrangements. Keep the transceiver close to the connector or bus stub, use a continuous ground reference beneath the bus route, and follow the datasheet layout guidance for decoupling capacitors and exposed-pad thermal management. Verify logic levels, loopback behavior, standby polarity, and bus fault handling in the final firmware.

This product page consolidates the exact package, electrical limits, protocol capabilities, drop-in alternatives, comparison parameters, and PCB guidance needed to evaluate the TCAN332DCNR for a 3.3 V CAN FD design.

直接替换替代料: TCAN332DCNR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: TCAN332DCNR (相同外形与封装尺寸) ——差异在于 Product Type, Operating Temperature Range, Package, Supply Voltage, Number of Channels.

Texas Instruments
Product Type: 1/1 CAN bus transceiver
Supply Voltage: 3.3V
对比 TCAN332DCNR →
Texas Instruments
Product Type: 3.3 V CAN transceiver
Package: 8-pin SOIC
Supply Voltage: 3 V to 3.63 V
对比 TCAN332DCNR →
Texas Instruments
Product Type: 3.3 V CAN transceiver
Package: 8-pin SOIC
Supply Voltage: 3 V to 3.63 V
对比 TCAN332DCNR →
Texas Instruments
Product Type: CAN Transceiver (CAN FD, High-Speed)
Operating Temperature Range: -40 C to +125 C
Package: SOT-23-8 (DCN)
对比 TCAN332DCNR →
Texas Instruments
Product Type: 3.3 V CAN FD transceiver
Operating Temperature Range: -40°C to 125°C
对比 TCAN332DCNR →

TCAN330DCNR

✅ 直接替换 ⚠️ 规格未核验
Texas Instruments
📦 8-pin SOT-23 (DCN)
1/1 CAN bus transceiver · 3V to 3.6V · 1Mbps · 1 · 1 · 20uA · 60mA · -40°C to +125°C

联系询价

查看数据手册 →

TCAN331DCNR

✅ 直接替换 ⚠️ 规格未核验
📦 8-pin SOT-23 (DCN)
Classic CAN operation with a higher maximum data rate than the 1 Mbps TCAN332DCNR

📋 参考替代料(不在目录中)

TCAN334DCNT

✅ 直接替换 ⚠️ 规格未核验
Texas Instruments
📦 8-pin SOT-23 (DCN)
3.3 V CAN FD transceiver · 3 V to 3.6 V · 1 Mbps · Supported · 1/1 half duplex · 8-pin SOT-23 (DCN) · 8 pins · -40°C to 125°C

联系询价

查看数据手册 →

TCAN1042DCNR

✅ 直接替换 ⚠️ 规格未核验
📦 8-pin SOT-23 (DCN)
Different low-power sleep-mode implementation while retaining the 3.3 V CAN physical-layer function

📋 参考替代料(不在目录中)

TCAN2302DCNR

✅ 直接替换 ⚠️ 规格未核验
📦 8-pin SOT-23 (DCN)
Family-level shutdown and standby behavior differs while the 3.3 V CAN interface and 8-pin footprint remain aligned

📋 参考替代料(不在目录中)

TCAN332DCNR 规格参数

Product Type CAN FD transceiver
电源电压 3.0 V to 3.63 V
Nominal Supply Voltage 3.3 V
Maximum Data Rate 1 Mbps
Supported Protocols CAN and CAN FD
Number of Channels 1 channel
Receiver Common-Mode Input Range -2 V to 7 V
工作温度范围 -40°C to +125°C
封装 8-pin SOT-23 (DCN)
引脚数 8 pins
安装类型 Surface mount
Power-Down and Standby Modes Supported
MSL 等级 MSL 1 at 260°C
MSL Duration Unlimited
RoHS 状态 Compliant

TCAN332DCNR 8-pin sot-23 (dcn) 引脚配置指南

TCAN332DCNR(8-pin sot-23 (dcn) 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。

TCAN332DCNR 的 8-pin sot-23 (dcn) 封装引脚图

暂无详细引脚数据: TCAN332DCNR.

请参阅 数据手册 以查看完整引脚配置。

典型应用

TCAN332DCNR 适用于 6 应用s: Industrial Automation Controllers, Building Automation and HVAC Nodes, Battery-Powered Condition Monitoring, Electric Vehicle Subsystems, Robotics and Sensor Networks, CAN-Based Diagnostic Gateways.

🏭

Industrial Automation Controllers

The TCAN332DCNR fits industrial automation nodes that communicate over a 3.3 V CAN bus and may later add CAN FD-capable equipment. Its 3.0 V to 3.63 V supply range, 1 Mbps maximum data rate, and -40°C to +125°C operating range support controller, sensor-hub, and actuator-gateway designs in factory environments. The single-channel DCN package saves board area, while shutdown and standby modes help satisfy power-management targets. In a typical controller, the transceiver connects the CANH and CANL bus terminals to a local CAN controller and receives TXD and RXD logic signals. Designers should use the manufacturer-recommended decoupling and protection arrangements and verify that all field-bus timing remains compatible with the selected CAN FD network.

🏭

Building Automation and HVAC Nodes

TCAN332DCNR is appropriate for compact building-automation and HVAC controller modules that use a 3.3 V embedded processor and a shared CAN backbone. The 8-pin SOT-23 footprint preserves board area compared with larger transceivers, while CAN FD support provides protocol headroom for mixed building systems. Its 1 Mbps maximum data rate is suitable for common controller, damper, sensor, and gateway traffic. Place the transceiver near the bus connector or short bus stub, maintain a continuous ground reference, and apply the datasheet's recommended protection. Because standby and wake behavior influence building power budgets, the system firmware should coordinate the transceiver state with the host controller rather than treating the interface as continuously active.

🧩

Battery-Powered Condition Monitoring

The TCAN332DCNR supports compact battery-operated monitoring equipment that must communicate through a low-voltage CAN network. Its 3.3 V operating class, shutdown mode, and standby mode provide useful power-control options when measurements are taken intermittently. The -40°C to +125°C specification also supports equipment intended for wide environmental ranges. A typical implementation places the transceiver beside a low-power MCU and a protected CAN connector, allowing the controller to wake the network only when a measurement or diagnostic message must be transmitted. The shutdown and standby levels must be coordinated with the MCU's I/O voltages, and the complete node's sleep current should be measured because transceiver consumption alone does not determine the final battery life.

🚗

Electric Vehicle Subsystems

TCAN332DCNR can interface 3.3 V embedded controllers in electric-vehicle subsystems that use CAN FD, such as body, thermal-management, or seat electronics. Its 1 Mbps maximum data rate and wide -40°C to +125°C operating range fit many distributed control networks, while the compact DCN package supports dense electronics. The 3.0 V to 3.63 V supply range permits direct use with a regulated 3.3 V rail. In a vehicle installation, the designer must add the surge, ESD, load-dump, and transient protection required by the applicable OEM specification. The transceiver's -2 V to +7 V receiver common-mode range should not be treated as a substitute for external vehicle-bus protection.

⚙️

Robotics and Sensor Networks

The TCAN332DCNR is useful in robot controllers, actuator modules, and distributed sensor networks where a CAN bus connects multiple nodes under a 3.3 V power budget. CAN FD support can improve payload efficiency compared with classic CAN, while the single-channel SOT-23 package leaves more PCB area for sensors or processing. The 1 Mbps rate and wide temperature range suit many compact industrial and mobile systems. Keep CAN routing away from high-current motor traces, provide a solid ground plane, and place protection close to external connectors. The host controller should verify nominal and fault-mode bus timing because a network that relies on 1 Mbps classic CAN operation must also remain compatible with the CAN FD-capable transceiver.

🖥️

CAN-Based Diagnostic Gateways

TCAN332DCNR supports diagnostic gateways that translate between a 3.3 V host processor and an external CAN bus. Its CAN FD capability permits efficient transfer of diagnostic data, event logs, and configuration payloads while its 1 Mbps maximum data rate covers conventional CAN networks. The compact 8-pin DCN package helps gateways placed at the edge of machinery or vehicle systems. A gateway implementation should use the manufacturer's recommended ground and capacitor layout, confirm standby polarity, and include bus protection appropriate to the installation. If the gateway must remain in a low-power state while preserving diagnostics, coordinate the transceiver's shutdown or standby mode with the host wake strategy and verify recovery time before the first transmitted frame.

What is the TCAN332DCNR?
The TCAN332DCNR is a Texas Instruments 3.3 V, single-channel CAN FD physical-layer transceiver rated for operation from 3.0 V to 3.63 V and data rates up to 1 Mbps. According to the TCAN332 manufacturer datasheet, it supports CAN and CAN FD communication in an 8-pin SOT-23 DCN package. It is intended for controllers operating from a 3.3 V supply.
What are the key specifications of TCAN332DCNR that engineers should know?
The TCAN332DCNR combines a 3.3 V supply range of 3.0 V to 3.63 V, one CAN channel, a maximum 1 Mbps data rate, and CAN FD support. According to the Texas Instruments TCAN332 product page and datasheet, the device is offered in an 8-pin SOT-23 DCN package and operates from -40°C to +125°C. Its receiver accepts common-mode voltages from -2 V to 7 V.
Where can I download the TCAN332DCNR datasheet PDF?
The TCAN332DCNR datasheet PDF is available from the official Texas Instruments document link on this page. The document is titled for the TCAN33x 3.3 V CAN transceivers with CAN FD and covers the TCAN332 family. According to the manufacturer document, the TCAN332DCNR operates from a 3.0 V to 3.63 V supply and supports data rates up to 1 Mbps.
Where can I find the TCAN332DCNR pinout?
Use the pin-description table and package drawing in the Texas Instruments TCAN332 manufacturer datasheet to identify the TCAN332DCNR connections. The DCN package contains eight pins and includes the CAN bus, digital interface, supply, ground, and control or enable functions required for operation. The public product result identifies the device specifically as an 8-pin SOT-23 package.
Is TCAN332DCNR suitable for 3.3 V CAN FD applications?
Yes, the TCAN332DCNR is suitable for 3.3 V CAN FD applications. According to the Texas Instruments TCAN332 product page, the device is a 3.3 V CAN transceiver with CAN FD support, a 1 Mbps maximum data rate, and a 3.0 V to 3.63 V operating supply range. It also supports shutdown and standby modes for reduced-power designs.
What is the difference between TCAN332DCNR and TCAN330DCNR?
The TCAN332DCNR supports CAN FD, while the TCAN330DCNR is the classic-CAN member of the related 3.3 V family. Both use the 8-pin DCN SOT-23 format, making TCAN330DCNR the relevant choice when classic CAN is sufficient and CAN FD is unnecessary. Confirm every pin function, power-state behavior, and timing requirement against the manufacturer datasheet before exchanging the devices.
When should I choose TCAN332DCNR over TCAN330DCNR?
Choose the TCAN332DCNR when the CAN bus must carry CAN FD frames or when future protocol compatibility is important. Choose the TCAN330DCNR only when the network is restricted to classic CAN and the application does not require CAN FD signaling. Both devices use the compact 8-pin DCN package, but protocol capability is the decisive selection criterion.
What can replace the TCAN332DCNR?
The closest same-manufacturer drop-in choices include the TCAN330DCNR for classic CAN, the TCAN331DCNR for higher-rate classic CAN, and the TCAN334DCNT for faster CAN FD operation. All are 3.3 V TCAN-family devices in the 8-pin DCN footprint. Because bus timing, standby behavior, and selected features can differ, verify the complete datasheet requirements before approving a replacement.
Can TCAN330DCNR replace TCAN332DCNR?
The TCAN330DCNR can serve as a pin-compatible classic-CAN alternative when CAN FD is not required, because both devices use the 8-pin DCN SOT-23 footprint and 3.3 V supply class. It is not an equivalent choice for a CAN FD network. According to the manufacturer family documentation, protocol support and low-power operating details must be checked before substitution.
What is the best cross-brand equivalent for TCAN332DCNR?
No verified cross-brand drop-in equivalent is established for the TCAN332DCNR. The documented replacement path points to other members of the Texas Instruments TCAN family, including the TCAN330DCNR and TCAN334DCNT. A cross-brand candidate should not be selected solely from its package name; its pinout, supply voltage, CAN FD timing, standby polarity, and bus-fault behavior must be independently verified.
Is TCAN332DCNR the same as TCAN334DCNT?
No, the TCAN332DCNR and TCAN334DCNT are related 3.3 V, 8-pin DCN CAN transceivers but are not functionally identical. The TCAN332DCNR supports CAN FD up to 1 Mbps, while the TCAN334 variant is positioned for higher CAN FD data rates. Their shared footprint permits board-level replacement in suitable designs, but timing and network requirements still require verification.
Where can I buy TCAN332DCNR online?
Use the Request a Quote form on this page to ask about TCAN332DCNR availability, current pricing, and order handling. The manufacturer identifies the TCAN332DCNR as an active 3.3 V, 8-pin SOT-23 CAN FD transceiver, but current stock, lot allocation, and lead time can vary by quantity. A formal quote provides the most appropriate response for production procurement.
What is the price of TCAN332DCNR?
Current TCAN332DCNR pricing is available through the Request a Quote form on this page. Pricing can depend on quantity, order breaks, inventory, and device markings, so a fixed figure may not reflect the purchasing quantity or delivery schedule. Submit the required quantity and target date with the quote request for a current commercial response.
What is the lead time for TCAN332DCNR?
The current TCAN332DCNR lead time should be confirmed through the Request a Quote form on this page. Lead time depends on order quantity, manufacturing allocation, packaging requirements, and current channel inventory. Include your annual usage, forecast, target date, and required package or reel configuration in the request so the supplier can respond with an actionable schedule.
Is TCAN332DCNR in stock?
Current TCAN332DCNR stock status should be checked through the Request a Quote form on this page. Inventory can vary by lot, quantity, and shipment destination, and the manufacturer product page identifies the part as a 3.3 V, 8-pin SOT-23 transceiver. Submit the required quantity and delivery region for an availability response tied to your order.
Does TCAN332DCNR meet industrial temperature requirements?
The TCAN332DCNR is specified for operation from -40°C to +125°C, covering the range commonly required by industrial equipment. According to the Texas Instruments TCAN332 product page and distributor listing, the -40°C to 125°C rating applies directly to the DCN package. Confirm enclosure temperatures and thermal conditions at the PCB level before treating the device as thermally sufficient.
How should the TCAN332DCNR be protected on a CAN bus?
Use the protection and termination approach shown in the Texas Instruments TCAN332 manufacturer datasheet for the target bus topology and fault environment. The transceiver's receiver accepts common-mode voltages from -2 V to 7 V, but that operating range does not remove the need for surge, ESD, or automotive transient protection. Match the protection device to the required CAN bus waveform and installation environment.
Can TCAN332DCNR be used in a battery-powered CAN node?
The TCAN332DCNR can be used in a battery-powered 3.3 V CAN node because it operates from 3.0 V to 3.63 V and provides shutdown and standby modes. According to the Texas Instruments TCAN332 family documentation, these low-power states can reduce consumption when communication is not continuously required. The host controller should also disable unused transceiver functions to control the complete node's standby current.

工程参考数据: TCAN332DCNR ——对比、设计指导和合规信息。

选型指南

Choose the TCAN332DCNR for a 3.3 V system that requires CAN FD communication, a compact 8-pin SOT-23 footprint, and operation across -40°C to +125°C. Select the TCAN330DCNR when the bus is permanently classic CAN and CAN FD capability is unnecessary; it provides the closest protocol simplification while retaining the same DCN footprint. Consider the TCAN331DCNR when classic CAN operation at a higher data rate is required, and consider the TCAN334DCNT when the design needs faster CAN FD performance. The TCAN1042DCNR is more appropriate when sleep-mode architecture drives the power-management decision, while the TCAN2302DCNR fits related 3.3 V interface requirements. For every alternative, verify the pin functions, timing limits, standby polarity, fault-mode behavior, and protection requirements in the manufacturer datasheet before releasing a production PCB.

与替代料对比

参数 本产品 TCAN330DCNR TCAN331DCNR TCAN334DCNT TCAN1042DCNR TCAN2302DCNR
Package 8-pin SOT-23 (DCN) 8-pin SOT-23 (DCN) 8-pin SOT-23 (DCN) 8-pin SOT-23 (DCN) 8-pin SOT-23 (DCN) 8-pin SOT-23 (DCN)
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Number of Channels 1 channel 1 channel 1 channel 1 channel 1 channel 1 channel

关键差异点

  • CAN FD capability in a 3.3 V single-channel transceiver (对比 TCAN330DCNR)
  • Matches the 1 Mbps class of TCAN330DCNR while adding FD protocol support (对比 TCAN330DCNR)
  • Compact 8-pin SOT-23 integration with low-power control (对比 TCAN1042DCNR)

设计说明

Place the TCAN332DCNR close to the CAN connector or short bus stub and follow the manufacturer's DCN layout example for the input, output, and bypass capacitors. Keep the CANH and CANL route as a compact differential pair, avoid routing it alongside switching nodes, and provide a continuous ground reference beneath the bus path. This reduces external pickup and helps maintain predictable CAN signal integrity.

Decouple the 3.3 V transceiver supply locally and keep the return-current path short and low impedance. The device operates from 3.0 V to 3.63 V, so confirm that supply tolerance, startup droop, and transient behavior remain inside that range at the TCAN332DCNR pins. Coordinate standby and shutdown levels with the host controller so an undriven input cannot place the interface into an unintended operating state.

Do not substitute a classic-only CAN device when the connected network may transmit CAN FD frames, and do not assume a higher-speed TCAN variant is automatically preferable. Check protocol support, maximum data rate, recessive-dominant timing, standby polarity, fault behavior, and loopback timing against the complete system requirements. Reconfirm every DCN pin function before replacing the TCAN332DCNR.

The CAN bus is a differential physical-layer interface, but poor grounding or external protection placement can still introduce emissions and susceptibility problems. Use a short CANH-to-CANL route, avoid large loops, bond the interface ground to the main ground plane, and mount bus protection close to the connector. Apply termination only where required by the bus topology, following the manufacturer's guidance rather than adding arbitrary parallel resistance.

合规信息

RoHS
Compliant
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

RoHS-compliant status and MSL 1 at 260°C unlimited floor-life information are identified for the TCAN332DCNR. Other compliance and qualification attributes require confirmation from the manufacturer.

数据核验日期: 2026-11-10 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

TCAN332DCNR datasheet TCAN332DCNR pinout TCAN332DCNR datasheet pdf TCAN332DCNR equivalent TCAN332DCNR replacement TCAN332DCNR vs TCAN330DCNR TCAN332DCNR vs TCAN334DCNT TCAN332DCNR SOT-23-8 TCAN332DCNR 3.3V CAN FD TCAN332DCNR price TCAN332DCNR stock Texas Instruments TCAN332DCNR TCAN332DCNR industrial CAN TCAN332DCNR automotive CAN bus What is TCAN332DCNR used for?

相关元器件 & 术语

Texas Instruments TCAN332DCNR TCAN330DCNR TCAN331DCNR TCAN334DCNT TCAN1042DCNR TCAN2302DCNR CAN transceiver CAN FD Controller Area Network physical-layer interface 3.3 V transceiver 1 Mbps CAN SOT-23-8 DCN package surface-mount IC differential bus CANH CANL shutdown mode standby mode common-mode voltage RoHS REACH
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达