The Texas Instruments TMP117 is a high-accuracy, low-power digital temperature sensor delivering a 16-bit result with 0.0078°C resolution and up to ±0.1°C accuracy from -20°C to 50°C without calibration, in a 6-pin WSON (DRV) or WCSP-6 (YBGR) package. It is designed to meet ASTM E1112 and ISO 80601 requirements for electronic patient thermometers and serves as a single-chip digital alternative to PT100/PT1000 platinum RTDs.

A digital temperature sensor is an IC that measures its own die temperature and outputs the value over a serial bus such as I2C or SMBus. Within the semiconductor hierarchy, the TMP117 belongs to the local digital temperature sensor family under temperature sensor ICs. Compared with analog solutions (thermistors, RTDs), it eliminates signal conditioning, ADCs, and calibration while improving linearity and system accuracy.

Key features include a 1.8V to 5.5V supply range (operating from 1.7V per TI datasheet SBOS961), 3.5uA typical operating current for battery-powered designs, and a 48-bit onboard EEPROM storing configuration and temperature offset calibration. Programmable high/low limit registers drive an ALERT interrupt pin, enabling autonomous over-temperature monitoring without host polling.

Technically, the TMP117 uses a bandgap-based sensing element digitized by a precision ADC. It is factory-calibrated and NIST-traceable, and supports four I2C/SMBus addresses (0x48 to 0x4B) via the ADD0 pin, so up to four devices can share one bus. Low 3.5uA consumption minimizes self-heating error, which is often the dominant accuracy limit in tiny WSON and WCSP packages. Accuracy is ±0.15°C across the extended -40°C to 125°C range.

Typical applications include medical patient thermometers, wearable health monitors, cold-chain data loggers, HVAC systems, and precision instrumentation RTD replacement. Its ±0.1°C uncalibrated accuracy outperforms most competitive digital sensors such as the DS18B20 or HDC1080.

Design tip: place the sensor thermally close to the measured source; per TI layout guidance, keep the decoupling capacitor within 5mm and I2C pull-up resistors at least 10mm away to minimize self-heating and noise. Prices as of 2026-08-30.

直接替换替代料: TMP117 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

TMP116

✅ 直接替换
📦 WSON-6 (DRV)
TI-listed drop-in replacement, same 6-pin DRV package and I2C operation, fewer EEPROM/offset features

📋 参考替代料(不在目录中)

TMP117-Q1

✅ 直接替换
Texas Instruments
📦 WSON-6 (DRV)
Digital temperature sensor, I2C/SMBus · +/-0.1 C (-20 C to +50 C) · 16-bit, 0.0078 C · -55 C to +150 C · I2C-compatible, SMBus-compatible, up to 2 Mbps · 1.8 V to 5.5 V · 9 addresses, no address strap pin required

✓ 有现货

$1.29 / 个

查看数据手册 →

TMP117M

✅ 直接替换 ⚠️ 规格未核验
📦 WSON-6 (DRV)
medical-recalibrated variant, guaranteed ±0.1°C over 0°C to 50°C patient range

📋 参考替代料(不在目录中)

TMP118

✅ 直接替换
📦 WSON-6 (DRV)
lower-cost newer variant, reduced EEPROM/offset features, register differences to verify

📋 参考替代料(不在目录中)

ℹ️ 1 个跨封装料号已隐藏——不同封装需要 PCB 改动,并非真正的直接替换。 联系我们 如果您需要跨封装建议。

TMP117 最大额定值与电气特性

传感器类型 Digital, Local Temperature Sensor
Accuracy ±0.1°C (-20°C to +50°C)
Extended Accuracy ±0.15°C (-40°C to +125°C)
测量范围 -55°C to +150°C
分辨率 0.0078°C (16-bit)
接口 I2C / SMBus, 2-wire
I2C Addresses 4 (0x48 to 0x4B) via ADD0 pin
电源电压 1.8 V to 5.5 V
电源电流 3.5 uA (typical)
Onboard Memory 48-bit EEPROM (config + offset calibration)
Alert Function Programmable ALERT pin, high/low limit registers
Calibration Factory-calibrated, NIST-traceable
Medical Compliance ASTM E1112, ISO 80601 (patient thermometers)
Package (DRV) WSON-6 (DRV) 2x2 mm
Package (YBGR) WCSP-6 (YBGR) 1.49x0.95 mm
安装类型 Surface Mount
RoHS 状态 Compliant

TMP117 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 SDA — I2C/SMBus serial data
引脚 2 ADD0 — Address select pin (0x48-0x4B)
引脚 3 ALERT — Alert interrupt output
引脚 4 GND — Ground
引脚 5 SCL — I2C/SMBus serial clock
引脚 6 VDD — Power supply, 1.8V to 5.5V

典型应用

TMP117 适用于 6 应用s: Medical Patient Thermometers, Wearable Health Monitors, Cold-Chain Data Loggers, RTD Replacement in Precision Instrumentation, HVAC and Building Automation, Battery Management and Power Supply Monitoring.

💊

Medical Patient Thermometers

The TMP117 was explicitly designed to meet ASTM E1112 and ISO 80601 requirements for electronic patient thermometers. Its ±0.1°C accuracy from -20°C to +50°C with no field calibration and NIST-traceable factory calibration satisfy clinical accuracy demands directly. The TMP117M variant guarantees ±0.1°C over the 0°C to 50°C patient range. Its 3.5uA consumption extends battery life in handheld thermometers, and the EEPROM offset register supports per-device calibration for clinical audits.

📱

Wearable Health Monitors

Wearables need skin-temperature accuracy with minimal self-heating and ultra-low power. The TMP117's 3.5uA typical current and 1.8V-5.5V operation fit small lithium-cell designs, while the 1.49x0.95mm WCSP-6 (YBGR) package minimizes thermal mass for fast skin-temperature response. The ALERT pin allows autonomous threshold interrupts without waking the host MCU continuously. Compared with thermistor solutions, the digital output eliminates ADC noise and calibration drift in humid, thermally noisy body-worn environments.

🧩

Cold-Chain Data Loggers

Cold-chain monitoring demands verified accuracy across shipping temperature extremes. The TMP117 measures -55°C to +150°C with ±0.15°C from -40°C to +125°C, covering freezer-to-ambient excursions without degradation. The 48-bit EEPROM stores logger configuration and calibration offsets locally, and the factory NIST-traceable calibration removes per-unit field calibration cost. Its 3.5uA consumption supports months-long battery logging, and I2C multi-addressing lets one logger MCU monitor up to four thermal points.

🔧

RTD Replacement in Precision Instrumentation

For non-medical precision sensing, the TMP117 replaces PT100/PT1000 platinum RTDs as a single-chip digital solution. A classic RTD chain requires an excitation current source, instrumentation amplifier, precision ADC, and ratiometric calibration; the TMP117 achieves ±0.1°C accuracy with only I2C wiring, cutting BOM cost and board area. Its digital output is immune to lead-wire resistance errors that plague 2-wire and 3-wire RTD installations, and long-term stability benefits from the EEPROM offset-compensation register.

🏭

HVAC and Building Automation

HVAC thermostats and zone controllers benefit from the TMP117's ±0.1°C room-temperature accuracy, which directly improves comfort-band control and energy efficiency. Four selectable I2C addresses (0x48-0x4B) allow multiple sensors on a single two-wire bus run, simplifying multi-zone boards. The programmable ALERT thresholds enable autonomous over-temperature protection of equipment (fans, dampers) without continuous host polling, and the 5.5V maximum supply tolerates common 5V logic rails in building controllers.

⚡

Battery Management and Power Supply Monitoring

Battery packs and power supplies need temperature monitoring for charging safety and derating. The TMP117 monitors -55°C to +150°C, covering lithium-cell charge/discharge windows and hot-spot tracking near power stages. Its 1.8V-5.5V supply and 3.5uA draw integrate easily into battery-monitor front ends, while the ALERT pin provides hardware-level over-temperature interrupt to the pack controller independent of firmware polling. The digital I2C output avoids ADC channel loading in multi-cell gauging architectures.

What is the accuracy of the TMP117 temperature sensor?
The TMP117 provides up to ±0.1°C accuracy from -20°C to +50°C with no calibration, and ±0.15°C across the wider -40°C to +125°C range. According to TI datasheet SBOS961, the 16-bit result has 0.0078°C resolution and the device is factory-calibrated and NIST-traceable.
What is the best drop-in replacement for TMP117?
The TI TMP116 is the best drop-in replacement: it is pin-compatible in the same WSON-6 (DRV) package with similar 16-bit I2C operation and ±0.1°C-class accuracy, though it lacks some TMP117 features such as the extended EEPROM capabilities. The TMP117-Q1 offers the same die with AEC-Q100 automotive qualification. Both require no PCB changes.
TMP117 vs TMP116 - which is better for medical thermometers?
For medical patient thermometers, choose the TMP117: it is explicitly designed to meet ASTM E1112 and ISO 80601 requirements and provides ±0.1°C accuracy from -20°C to +50°C with a 48-bit EEPROM offset register. The TMP116 shares the same DRV package and I2C interface but is targeted at general precision sensing rather than medical compliance.
What is the difference between TMP117 and TMP118?
The TMP118 is a newer, more cost-effective variant that is pin-compatible with the TMP117 but omits some features - notably the EEPROM offset-calibration flexibility and certain register behaviors are reduced. According to TI E2E forum discussions, wearables considering TMP117-to-TMP118 migration mainly trade away the on-chip calibration memory for lower price; verify register compatibility in your firmware before switching.
What supply voltage and current does the TMP117 require?
The TMP117 operates from 1.7V to 5.5V and typically consumes 3.5uA, making it well suited to battery-powered wearables and data loggers. According to TI datasheet SBOS961, low current consumption minimizes self-heating error, which is often the dominant accuracy limit in the small 2x2mm WSON-6 package.
How many TMP117 sensors can share one I2C bus?
Up to four TMP117 devices can share a single I2C or SMBus. The ADD0 pin selects one of four addresses: 0x48, 0x49, 0x4A, or 0x4B. This multi-drop capability lets designers monitor several thermal zones with one controller, and the shared ALERT functionality still supports per-device limit registers stored in each device's EEPROM.
Where to buy TMP117 and what does it cost?
The TMP117 is available from authorized distributors including DigiKey (TMP117AIYBGR and DRV variants), Mouser, and on XAIPART. Pricing as of 2026-08-30 is approximately $1.15-$2.05 per unit depending on quantity, with 1000-piece pricing near $1.15. Check distributor stock pages for live availability and reel pricing.
Is the TMP117 in stock and what is the lead time?
Yes, the TMP117 is an active, high-volume TI part generally stocked by DigiKey and Mouser with same-day shipping for small quantities, per DigiKey listings. Lead times for production quantities typically range from a few days (in-stock reels) to standard factory lead time of several weeks. Confirm current stock at your distributor before scheduling builds.
Where can I download the TMP117 datasheet PDF?
The official TMP117 datasheet PDF is available from TI at https://www.ti.com/lit/ds/symlink/tmp117.pdf (document SBOS961, 45 pages). It includes the full pinout for both WSON-6 (DRV) and WCSP-6 (YBGR) packages, register maps, EEPROM programming details, and PCB layout guidance for medical thermometer designs.
What are the key specifications of the TMP117 engineers should know?
Key TMP117 specifications: ±0.1°C accuracy (-20°C to +50°C, no calibration), 16-bit resolution (0.0078°C), -55°C to +150°C measurement range, 1.8V-5.5V supply, 3.5uA typical current, I2C/SMBus interface with 4 selectable addresses (0x48-0x4B), 48-bit EEPROM, programmable ALERT pin, and ASTM E1112/ISO 80601 medical compliance. Source: TI datasheet SBOS961.
Is the TMP117 suitable for replacing PT100/PT1000 RTDs?
Yes, for non-medical precision applications the TMP117 serves as a single-chip digital alternative to platinum RTDs. It provides ±0.1°C accuracy without the excitation current sources, instrumentation amplifiers, ADCs, and calibration that a PT100/PT1000 system requires, cutting BOM cost and board area dramatically while improving long-term stability, per TI datasheet SBOS961.
What is the best cross-brand equivalent for TMP117?
There is no true cross-brand pin-to-pin equivalent for the TMP117 in the WSON-6 (DRV) package. Functionally comparable high-accuracy digital sensors include the Analog Devices ADT7422 and Silicon Labs Si7051, both offering ±0.1°C-class accuracy with I2C, but they use different packages and pinouts, so PCB layout changes and firmware register updates are required for substitution.
What layout precautions does the TMP117 need for accuracy?
Follow TI's layout guidance: place the decoupling capacitor within 5mm of the sensor supply pin and keep I2C pull-up resistors at least 10mm away to minimize self-heating and noise coupling. The sensor should be thermally close to the measured source, and trace widths to the package should be minimized so copper does not act as a heat sink biasing the reading.

工程参考数据: TMP117 ——对比、设计指导和合规信息。

选型指南

Choose the TMP117 when you need ±0.1°C uncalibrated accuracy, medical compliance (ASTM E1112/ISO 80601), or single-chip RTD replacement: no competitive digital sensor combines all three in a 2x2mm WSON package at 3.5uA. Choose TMP116 if you need a verified drop-in and can forgo some EEPROM/offset features. Choose TMP117-Q1 for AEC-Q100 automotive programs - identical die and footprint. Choose TMP118 when cost dominates and your firmware can tolerate register/EEPROM differences. Choose the WCSP-6 (YBGR) variant when thermal response speed or size matters more than assembly ease. Cross-brand alternatives (ADT7422, Si7051) match accuracy class but require PCB rework - reserve them for new designs, not substitutions.

与替代料对比

参数 本产品 TMP116 TMP117-Q1 TMP118 TMP117AIYBGR
Package WSON-6 (DRV) 2x2mm WSON-6 (DRV) - same WSON-6 (DRV) - same WSON-6 (DRV) - same WCSP-6 (YBGR) - different
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Accuracy (-20 to 50C) ±0.1°C ±0.1°C class ±0.1°C ±0.1°C ±0.1°C
Resolution 0.0078°C (16-bit) 16-bit 0.0078°C (16-bit) 16-bit 0.0078°C (16-bit)
Onboard EEPROM 48-bit (config + offset) Yes (reduced) 48-bit Yes (reduced features) 48-bit
AEC-Q100 Qualification No (standard) No Yes No No

关键差异点

  • Uncalibrated ±0.1°C accuracy with medical compliance (对比 TMP116)
  • Automotive option on identical die (对比 TMP117-Q1)
  • Full EEPROM calibration flexibility vs low-cost variant (对比 TMP118)

设计说明

Per TI layout guidance (datasheet SBOS961 and TI E2E forum), place the decoupling capacitor within 5mm of the VDD pin and keep I2C pull-up resistors at least 10mm away from the sensor. Pull-up traces carry current that self-heats the tiny 2x2mm package; even milliwatts can bias readings above the ±0.1°C target.

Self-heating is the dominant accuracy limit. The 3.5uA operating current produces negligible dissipation, but the ALERT pin sinking external loads or long copper traces to the thermal source will bias measurements. Thermally isolate the sensor from hot components and, for skin measurements, choose the WCSP-6 (YBGR) variant for lower thermal mass and faster response.

Do not omit the EEPROM configuration write in firmware: reset defaults may not match your averaging/alert settings. Use 1% or better I2C pull-ups sized for bus capacitance at 400kHz. When substituting TMP118 for TMP117 to cut cost, verify register map and EEPROM behavior differences first - some offset-calibration workflows are not identical.

合规信息

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Yes
无卤
Unknown
冲突矿物
Unknown

RoHS compliant per TI product page. Meets ASTM E1112 and ISO 80601 medical thermometer requirements. AEC-Q100 available via TMP117-Q1 variant. REACH/halogen status [DATA_NEEDED] - verify on TI quality pages.

数据核验日期: 2026-08-30 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

TMP117 TMP117 datasheet Texas Instruments TMP117 TMP117 ±0.1°C digital temperature sensor TMP117 WSON-6 DRV package pinout TMP117 medical thermometer ASTM E1112 TMP117 vs TMP116 TMP117 drop-in replacement equivalent TMP117 buy price what is the accuracy of TMP117 TMP117 PT100 RTD replacement TMP117 I2C address ADD0

相关元器件 & 术语

Texas Instruments TMP117 TMP116 TMP117-Q1 TMP118 TMP117AIYBGR digital temperature sensor temperature sensor IC I2C SMBus platinum RTD PT100 ASTM E1112 ISO 80601 WSON-6 WCSP-6 RoHS EEPROM offset calibration self-heating error patient thermometer cold-chain data logger
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情