ICL7136CPL+3 - 3.5-Digit LCD ADC | Analog Devices
MPN: ICL7136CPL+3 ✓ نشطICL7136CPL+3 نظرة عامة
A 3.5-digit ADC is a metering converter designed to resolve approximately 1999 count increments when paired with its decimal display. This resolution class is commonly used for panel meters, laboratory instruments, scales, process monitors, and portable measurement equipment where a readable numeric display is more important than high-resolution waveform acquisition. The ICL7136 belongs to the ADC/DAC and data-converter hierarchy within integrated circuit and display-interface applications.
The principal advantages of the ICL7136 are its very high input impedance, low-power operation, integrated reference and clock, and direct non-multiplexed LCD drive. These characteristics reduce external component count and simplify instrumentation designs. Seven-segment decoders and segment drivers are integrated on-chip, while the voltage reference and clock circuit establish the internal operating conditions needed for repeatable measurements.
The converter uses a dual-slope conversion technique suited to low-speed precision measurement. Dual-slope operation integrates the unknown input for a defined interval and compares the result against an internally generated reference interval. This architecture favors predictable behavior, resistance to noise within the designed bandwidth, and good performance when measuring slowly changing sensor signals rather than high-frequency waveforms. The integrated clock removes the need for an external timing source.
Typical ICL7136CPL+3 applications include digital panel meters, temperature indicators, pressure and force displays, laboratory bench instruments, medical equipment, and industrial process readouts. In these systems, the device converts a differential analog input and drives a dedicated LCD, simplifying the front end while preserving the familiar 3.5-digit presentation.
PCB design should preserve analog signal integrity around the input and reference nodes and provide suitable bypass capacitance near the supply pins. Because this is a through-hole PDIP device, designers should also account for its larger footprint compared with surface-mount converter packages. Confirm display polarity, segment wiring, input range, reference details, and timing requirements against the manufacturer datasheet before layout release.
This product page combines manufacturer and distributor information with a pin-compatible comparison, application guidance, and practical design notes. It is intended to help engineers evaluate the ICL7136CPL+3 for legacy instrumentation, retrofit programs, and new low-speed metering designs that require a self-contained 3.5-digit ADC and LCD driver.
بدائل مباشرة لـ ICL7136CPL+3 — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع ICL7136CPL+3 (نفس عامل الشكل والبصمة) — يختلف في Package, Resolution.
ICL7136CPL+
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←ICL7136CPL+
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←ICL7136CPLZ
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
ICL7109CPL
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←ICL7107CPLZ
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
ICL7136CPL+3 الحدود القصوى والخصائص الكهربائية
| ADC Resolution | 3.5 digits |
| Converter Architecture | Dual-slope ADC |
| Display Output | Direct non-multiplexed LCD drive |
| العلبة | 40-pin PDIP |
| Package Dimensions | 0.600 in (15.24 mm) width |
| نوع التركيب | Through-hole |
| Input Type | Differential |
| Number of Analog Input Channels | 1 |
| Input Impedance | Very high input impedance |
| Integrated Reference | Yes |
| Integrated Clock | Yes |
| Integrated Segment Decoders | Yes |
| Integrated Display Drivers | Yes |
دليل تكوين أطراف ICL7136CPL+3 0.600 in (15.24 mm) width
تكوين الأطراف لـ ICL7136CPL+3 (حزمة 0.600 in (15.24 mm) width). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ ICL7136CPL+3.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
ICL7136CPL+3 مناسب لـ 6 التطبيقs: Digital Temperature Panel Meter, Pressure and Force Indicator, Laboratory Bench Instrument, Process Monitoring Readout, Medical Measurement Readout, Legacy Meter Retrofit.
Digital Temperature Panel Meter
The ICL7136CPL+3 fits temperature instruments that present a stable numerical value on a dedicated 3.5-digit LCD. Its very high input impedance helps isolate the sensor interface from the conversion process, while the integrated reference, clock, seven-segment decoders, and segment drivers reduce the number of external support blocks. Place the converter behind the front-end amplifier or sensor network and connect the LCD according to the manufacturer pin table. The main benefit is a compact instrument architecture that preserves a familiar direct-display measurement format without requiring a separate display-driver IC.
موصى به
Pressure and Force Indicator
The ICL7136CPL+3 is appropriate for slow pressure or force measurements displayed as 3.5 decimal digits. The dual-slope conversion method is suited to relatively stable transducer outputs rather than rapidly changing waveforms, and the integrated clock provides repeatable conversion timing. Its integrated reference and direct LCD drivers allow the analog front end to feed a dedicated display without an external display-driver package. Engineers should select the input range, scaling network, and sensor excitation so the complete measurement remains within the converter's specified operating limits.
موصى به
Laboratory Bench Instrument
A bench meter can use the ICL7136CPL+3 when the required result is a stable, directly displayed measurement rather than a high-speed digital waveform. The device's high input impedance helps preserve sensor signals, while the integrated seven-segment decoders and LCD drivers simplify display integration. The 40-pin PDIP package is practical for hand-assembled, educational, and legacy laboratory equipment where through-hole construction supports manual assembly and repair. Validate the selected LCD's segment and common-plane connections against the manufacturer pinout before fabrication.
موصى به
Process Monitoring Readout
The ICL7136CPL+3 suits industrial process readouts that convert a slowly varying analog signal into a 3.5-digit LCD value. Its low-power, self-contained architecture can simplify local panel instruments, and the integrated reference and clock remove two common external support components. Place the converter in a protected analog section and maintain separation between sensitive input routing and multiplexed LCD drive connections. For deployed equipment, confirm the exact ordering code's temperature range and operating supply limits against the intended ambient environment.
موصى به
Medical Measurement Readout
The ICL7136CPL+3 can form the numerical display section of a low-speed medical or laboratory instrument that reports a bounded physiological or analytical value. Its high input impedance is useful when driving the converter from a carefully designed sensor amplifier, and the direct LCD output reduces display-system complexity. Because the device provides measurement conversion and display drive rather than clinical safety isolation, the complete system must supply the required isolation, protection, and validation. Verify medical qualification requirements separately from the component's electrical specifications.
موصى به
Legacy Meter Retrofit
The ICL7136CPL+3 is well suited to repairing or extending an existing 3.5-digit meter built around the ICL7136 architecture. Its 40-pin PDIP format supports direct board-level replacement when the display wiring, supply arrangement, input polarity, and reference network match the original design. The integrated clock, reference, decoders, and display drivers make it particularly useful where the original circuit depended on the ICL7136's monolithic architecture. Before installation, verify every connector and pin function against the manufacturer table rather than relying only on package dimensions.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ ICL7136CPL+3 — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | ICL7136CPL | ICL7136CPL+ | ICL7136CPLZ | ICL7109CPL | ICL7107CPLZ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Renesas Electronics | Analog Devices | Renesas Electronics |
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Converter Type | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC |
| Resolution | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 12 bits | 3.5 digits |
| Display Interface | Direct non-multiplexed LCD drive | Direct non-multiplexed LCD drive | Direct non-multiplexed LCD drive | Direct LCD drive | LCD driver | LCD driver |
| Primary Function | 3.5-digit LCD display driver ADC | 3.5-digit LCD display driver ADC | 3.5-digit LCD display driver ADC | 3.5-digit LCD display driver ADC | 12-bit LCD driver ADC | Low-power LCD ADC |
أبرز الفروقات
- Directly integrated LCD display path (مقابلICL7109CPL)
- Exact ICL7136 family architecture (مقابلICL7107CPLZ)
- High input impedance for measurement interfaces (مقابلICL7109CPL)
- Reduced external support circuitry (مقابلICL7136CPLZ)
ملاحظات التصميم
Route the analog input as a short, guarded trace away from LCD segment outputs, clock signals, and switching supply nodes. Place the input and reference components near the corresponding ICL7136CPL+3 pins to minimize parasitic pickup and impedance effects. Because a high-impedance input can be sensitive to leakage, keep board contamination and connector leakage in mind during leakage-sensitive measurements.
Install the recommended bypass capacitance between the supply pins and ground with the shortest practical connection. Keep the ground return from the analog input and reference network separate from noisy LCD-drive returns where the layout permits. Confirm the exact supply voltage, capacitor values, and allowable operating range in the manufacturer datasheet before populating the board.
Treat the 40-pin PDIP footprint as a through-hole layout rather than a compact surface-mount conversion. Maintain adequate clearance around adjacent pins and account for display cables and wiring strain. If modernizing an existing design, verify the replacement's pin numbering, LCD common connections, and pin-1 orientation physically before insertion to avoid damaging a legacy display assembly.
Do not assume that every ICL71xx 40-pin converter is electrically interchangeable with the ICL7136CPL+3. Resolution, display drive, segment mapping, reference behavior, and timing can differ even when the package outline matches. Check the manufacturer ordering table and pin-description table for each proposed alternative, and verify the LCD polarity and common-plane configuration before power is applied.
معلومات الامتثال
No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was identified for the exact ordering code.