INA122PAG4 - Low-Power Instrumentation Amplifier | Texas Instruments
MPN: INA122PAG4 ✓ نشطINA122PAG4 نظرة عامة
An instrumentation amplifier is a specialized amplifier that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. Its internal resistor arrangement and two-op-amp topology provide accurate gain control, low offset voltage, and strong common-mode rejection. The INA122 extends this architecture into a micropower package, making it particularly appropriate for portable medical instruments, battery-powered data-acquisition systems, and other low-power measurement equipment.
The INA122 can operate from either a single positive supply or dual supplies. Its 2.2 V minimum operating voltage supports low-voltage portable systems, while the 36 V maximum rating provides flexibility in industrial and instrumentation circuits. The approximately 60 µA quiescent current limits the static power requirement and helps conserve battery capacity when continuous signal acquisition is required.
Gain is set by an external resistor, allowing the circuit designer to select the sensitivity required for the sensor or measurement system. Because this is an instrumentation amplifier, input impedance remains high across the differential signal path, helping minimize loading of high-impedance sources. The device is intended for precision acquisition rather than high-speed waveform amplification, making it particularly suitable for slow sensor signals, strain-gauge bridges, biomedical instrumentation, and general-purpose data acquisition.
A practical design must keep input and output voltages within the device's operating limits and provide adequate bypassing around the supply pins. Input common-mode voltage and output swing are constrained by the selected supply configuration, so system-level headroom should be checked before scaling a sensor output. The external gain resistor should be located close to the gain-setting pin to limit parasitic resistance and preserve gain accuracy.
The INA122PAG4 is also suited to portable measurement systems where low quiescent current is more important than high bandwidth. Its compact 8-pin PDIP package is easy to prototype and inspect, making it useful for laboratory instruments, educational equipment, medical monitoring prototypes, and low-channel-count acquisition boards. This page combines the manufacturer specifications, package information, sourcing guidance, application guidance, and a practical comparison framework for engineers evaluating the INA122 and compatible instrumentation-amplifier options.
بدائل مباشرة لـ INA122PAG4 — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع INA122PAG4 (نفس عامل الشكل والبصمة) — يختلف في Gain Range, Quiescent Current, Package, Architecture, Common-Mode Rejection Ratio.
INA122PA
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←INA121PA
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←INA126PA
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←INA128PA
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←INA129PA
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←INA122PAG4 الحدود القصوى والخصائص الكهربائية
| لا تتوفر مواصفات |
دليل تكوين أطراف INA122PAG4 standard
تكوين الأطراف لـ INA122PAG4 (حزمة standard). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ INA122PAG4.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
INA122PAG4 مناسب لـ 6 التطبيقs: Portable Medical Signal Acquisition, Battery-Powered Data Acquisition, Strain-Gauge Bridge Measurement, Industrial Sensor Interface, Low-Level Voltage Measurement, Portable Test and Measurement Instrument.
Portable Medical Signal Acquisition
The INA122PAG4 fits portable medical monitoring equipment that acquires low-level differential sensor signals under strict power constraints. Its approximately 60 µA quiescent current minimizes the static burden imposed by the amplifier, while operation from 2.2 V supports compact battery-powered systems. The two-op-amp differential architecture can acquire physiological or diagnostic signals with high input impedance, reducing loading on sensitive transducers. Design the input network around the sensor's common-mode voltage and confirm the required output swing before choosing the external gain resistor. Single-supply operation is especially useful when the system must operate near zero volts, although safety, isolation, and regulatory requirements remain system-level considerations.
موصى به
Battery-Powered Data Acquisition
The INA122PAG4 is appropriate for multichannel or multiplexed data-acquisition systems in which each measurement path must conserve power. The approximately 60 µA quiescent current is a central benefit because the amplifier can remain present in a portable acquisition chain without dominating the power budget. A 2.2 V minimum operating voltage also allows direct compatibility with low-energy system rails. Use the external gain resistor to establish the required signal scaling, and place the device where sensor traces can remain short. The INA122 is optimized for precision, low-bandwidth measurement rather than high-speed sampling, so anti-aliasing and channel-switching effects should be included in the complete acquisition design.
موصى به
Strain-Gauge Bridge Measurement
The INA122PAG4 can amplify the small differential output of a strain-gauge bridge while rejecting common-mode voltage and electrical disturbances that affect both bridge inputs. Its differential-input architecture preserves measurement quality when the source impedance is relatively high, while the 2.2 V to 36 V supply range supports multiple instrumentation systems. External gain selection allows the circuit to be matched to the bridge sensitivity and excitation voltage. The bridge excitation itself should be referenced to the same system ground strategy to prevent excessive common-mode voltage. Because the INA122 is intended for precision acquisition, thermal drift, offset, gain error, and input bias effects must be included in the overall measurement uncertainty.
موصى به
Industrial Sensor Interface
The INA122PAG4 is useful at the front end of industrial sensor interfaces that convert low-level differential outputs into a voltage suitable for an ADC or controller. The high-input-impedance instrumentation-amplifier topology minimizes loading, and the broad 2.2 V to 36 V supply range accommodates both compact sensors and higher-voltage instrumentation interfaces. The approximately 60 µA quiescent current is valuable in remote or distributed monitoring equipment where power is constrained. Designers should check the input common-mode range against the sensor's output, verify headroom at the amplifier output, and use supply bypassing close to the package. Protection structures may also be needed when sensor wiring is long or exposed to industrial transients.
موصى به
Low-Level Voltage Measurement
The INA122PAG4 is suited to precision measurement of small differential voltages where a conventional single-ended amplifier would be sensitive to ground offsets or common-mode disturbances. Its two-op-amp instrumentation-amplifier configuration supports accurate gain setting with one external resistor and maintains balanced differential inputs. The low 60 µA quiescent current allows continuous monitoring from battery or energy-harvested systems. In implementation, verify that the input and output remain inside the datasheet limits at every process, temperature, and load condition. Keeping the gain resistor and input traces compact helps reduce sensitivity to parasitic resistance and unwanted pickup, particularly in low-level signals where microvolt-scale variations can affect the result.
موصى به
Portable Test and Measurement Instrument
The INA122PAG4 supports handheld and laboratory measurement products that combine precision signal conditioning with low power consumption. Its 8-pin PDIP package is straightforward to prototype, troubleshoot, and replace in educational or instrumentation hardware. The approximately 60 µA quiescent current helps extend operating time in battery-assisted instruments, while operation down to 2.2 V supports compact mixed-signal designs. The amplifier can condition differential sensor, transducer, or test-probe signals before conversion by an ADC. Gain must be chosen to keep the output within its swing range, and common-mode voltage must remain valid at both power-up and overload. The resulting circuit should also include protection appropriate to the probe connection and environment.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ INA122PAG4 — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | INA122PA | INA121PA | INA126PA | INA128PA | INA129PA |
|---|---|---|---|---|---|---|
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Mounting Type | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP |
أبرز الفروقات
- Lowest-power option among the listed same-package family choices (مقابلINA128PA)
- Broader stated supply capability than low-voltage instrumentation-amplifier alternatives (مقابلINA121PA)
- Direct same-family package option for prototype and replacement planning (مقابلINA122PA)
- Low-power differential acquisition with external gain control (مقابلINA129PA)
ملاحظات التصميم
Place the external gain-setting resistor close to the corresponding INA122 gain pin and keep differential input traces short and symmetrical. Long, mismatched traces can add parasitic capacitance, pickup, and effective resistance that disturb gain accuracy. Route inputs away from switching-converter nodes and high-current return paths. For a differential sensor, maintain similar geometry and grounding on both input branches whenever practical.
Check input common-mode voltage and output swing against the supply configuration before selecting the gain. The INA122 supports single- and dual-supply operation from 2.2 V to 36 V, but those supply limits do not permit every input or output voltage. Confirm that the sensor can remain within the common-mode range at minimum and maximum conditions and that the amplified output retains headroom for the ADC input range.
Do not assume that an 8-pin PDIP package alone guarantees interchangeability. Although the listed alternatives share the same package format, gain-setting pins, supply limits, common-mode range, offset, gain accuracy, and output behavior can differ. Compare the manufacturer pin-configuration and electrical-characteristics tables before substituting a part, and verify the exact ordering suffix used in the original bill of materials.
Decouple the supply pins near the package with the capacitance and layout recommended in the Texas Instruments INA122 datasheet. Keep the switching loop of any upstream converter physically separated from the input and reference connections. In a portable design, the INA122's approximately 60 µA quiescent current helps reduce static demand, but total power also depends on sensor current, output load, reference circuitry, and conversion electronics.
معلومات الامتثال
Compliance status was not established for this exact ordering code. Review the manufacturer product page, material declaration, and current quality documentation before making a compliance claim.