INA122PAG4 - Low-Power Instrumentation Amplifier | Texas Instruments
MPN: INA122PAG4 ✓ 啟用中INA122PAG4 概覽
An instrumentation amplifier is a specialized amplifier that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. Its internal resistor arrangement and two-op-amp topology provide accurate gain control, low offset voltage, and strong common-mode rejection. The INA122 extends this architecture into a micropower package, making it particularly appropriate for portable medical instruments, battery-powered data-acquisition systems, and other low-power measurement equipment.
The INA122 can operate from either a single positive supply or dual supplies. Its 2.2 V minimum operating voltage supports low-voltage portable systems, while the 36 V maximum rating provides flexibility in industrial and instrumentation circuits. The approximately 60 µA quiescent current limits the static power requirement and helps conserve battery capacity when continuous signal acquisition is required.
Gain is set by an external resistor, allowing the circuit designer to select the sensitivity required for the sensor or measurement system. Because this is an instrumentation amplifier, input impedance remains high across the differential signal path, helping minimize loading of high-impedance sources. The device is intended for precision acquisition rather than high-speed waveform amplification, making it particularly suitable for slow sensor signals, strain-gauge bridges, biomedical instrumentation, and general-purpose data acquisition.
A practical design must keep input and output voltages within the device's operating limits and provide adequate bypassing around the supply pins. Input common-mode voltage and output swing are constrained by the selected supply configuration, so system-level headroom should be checked before scaling a sensor output. The external gain resistor should be located close to the gain-setting pin to limit parasitic resistance and preserve gain accuracy.
The INA122PAG4 is also suited to portable measurement systems where low quiescent current is more important than high bandwidth. Its compact 8-pin PDIP package is easy to prototype and inspect, making it useful for laboratory instruments, educational equipment, medical monitoring prototypes, and low-channel-count acquisition boards. This page combines the manufacturer specifications, package information, sourcing guidance, application guidance, and a practical comparison framework for engineers evaluating the INA122 and compatible instrumentation-amplifier options.
直接替換替代品,適用於 INA122PAG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA122PAG4 (相同外形與佔位) — 差異在於 Gain Range, Quiescent Current, Package, Architecture, Common-Mode Rejection Ratio.
INA122PA
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →INA121PA
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →INA126PA
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →INA122PAG4 最大額定值與電氣特性
| 無規格資料 |
INA122PAG4 standard 腳位配置指南
INA122PAG4(standard 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA122PAG4.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA122PAG4 適用於 6 應用s: Portable Medical Signal Acquisition, Battery-Powered Data Acquisition, Strain-Gauge Bridge Measurement, Industrial Sensor Interface, Low-Level Voltage Measurement, Portable Test and Measurement Instrument.
Portable Medical Signal Acquisition
The INA122PAG4 fits portable medical monitoring equipment that acquires low-level differential sensor signals under strict power constraints. Its approximately 60 µA quiescent current minimizes the static burden imposed by the amplifier, while operation from 2.2 V supports compact battery-powered systems. The two-op-amp differential architecture can acquire physiological or diagnostic signals with high input impedance, reducing loading on sensitive transducers. Design the input network around the sensor's common-mode voltage and confirm the required output swing before choosing the external gain resistor. Single-supply operation is especially useful when the system must operate near zero volts, although safety, isolation, and regulatory requirements remain system-level considerations.
推薦
Battery-Powered Data Acquisition
The INA122PAG4 is appropriate for multichannel or multiplexed data-acquisition systems in which each measurement path must conserve power. The approximately 60 µA quiescent current is a central benefit because the amplifier can remain present in a portable acquisition chain without dominating the power budget. A 2.2 V minimum operating voltage also allows direct compatibility with low-energy system rails. Use the external gain resistor to establish the required signal scaling, and place the device where sensor traces can remain short. The INA122 is optimized for precision, low-bandwidth measurement rather than high-speed sampling, so anti-aliasing and channel-switching effects should be included in the complete acquisition design.
推薦
Strain-Gauge Bridge Measurement
The INA122PAG4 can amplify the small differential output of a strain-gauge bridge while rejecting common-mode voltage and electrical disturbances that affect both bridge inputs. Its differential-input architecture preserves measurement quality when the source impedance is relatively high, while the 2.2 V to 36 V supply range supports multiple instrumentation systems. External gain selection allows the circuit to be matched to the bridge sensitivity and excitation voltage. The bridge excitation itself should be referenced to the same system ground strategy to prevent excessive common-mode voltage. Because the INA122 is intended for precision acquisition, thermal drift, offset, gain error, and input bias effects must be included in the overall measurement uncertainty.
推薦
Industrial Sensor Interface
The INA122PAG4 is useful at the front end of industrial sensor interfaces that convert low-level differential outputs into a voltage suitable for an ADC or controller. The high-input-impedance instrumentation-amplifier topology minimizes loading, and the broad 2.2 V to 36 V supply range accommodates both compact sensors and higher-voltage instrumentation interfaces. The approximately 60 µA quiescent current is valuable in remote or distributed monitoring equipment where power is constrained. Designers should check the input common-mode range against the sensor's output, verify headroom at the amplifier output, and use supply bypassing close to the package. Protection structures may also be needed when sensor wiring is long or exposed to industrial transients.
推薦
Low-Level Voltage Measurement
The INA122PAG4 is suited to precision measurement of small differential voltages where a conventional single-ended amplifier would be sensitive to ground offsets or common-mode disturbances. Its two-op-amp instrumentation-amplifier configuration supports accurate gain setting with one external resistor and maintains balanced differential inputs. The low 60 µA quiescent current allows continuous monitoring from battery or energy-harvested systems. In implementation, verify that the input and output remain inside the datasheet limits at every process, temperature, and load condition. Keeping the gain resistor and input traces compact helps reduce sensitivity to parasitic resistance and unwanted pickup, particularly in low-level signals where microvolt-scale variations can affect the result.
推薦
Portable Test and Measurement Instrument
The INA122PAG4 supports handheld and laboratory measurement products that combine precision signal conditioning with low power consumption. Its 8-pin PDIP package is straightforward to prototype, troubleshoot, and replace in educational or instrumentation hardware. The approximately 60 µA quiescent current helps extend operating time in battery-assisted instruments, while operation down to 2.2 V supports compact mixed-signal designs. The amplifier can condition differential sensor, transducer, or test-probe signals before conversion by an ADC. Gain must be chosen to keep the output within its swing range, and common-mode voltage must remain valid at both power-up and overload. The resulting circuit should also include protection appropriate to the probe connection and environment.
推薦
推薦產品摘要
工程參考資料,適用於 INA122PAG4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA122PA | INA121PA | INA126PA | INA128PA | INA129PA |
|---|---|---|---|---|---|---|
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Mounting Type | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP | Through-hole PDIP |
主要差異化特點
- Lowest-power option among the listed same-package family choices (對比INA128PA)
- Broader stated supply capability than low-voltage instrumentation-amplifier alternatives (對比INA121PA)
- Direct same-family package option for prototype and replacement planning (對比INA122PA)
- Low-power differential acquisition with external gain control (對比INA129PA)
設計說明
Place the external gain-setting resistor close to the corresponding INA122 gain pin and keep differential input traces short and symmetrical. Long, mismatched traces can add parasitic capacitance, pickup, and effective resistance that disturb gain accuracy. Route inputs away from switching-converter nodes and high-current return paths. For a differential sensor, maintain similar geometry and grounding on both input branches whenever practical.
Check input common-mode voltage and output swing against the supply configuration before selecting the gain. The INA122 supports single- and dual-supply operation from 2.2 V to 36 V, but those supply limits do not permit every input or output voltage. Confirm that the sensor can remain within the common-mode range at minimum and maximum conditions and that the amplified output retains headroom for the ADC input range.
Do not assume that an 8-pin PDIP package alone guarantees interchangeability. Although the listed alternatives share the same package format, gain-setting pins, supply limits, common-mode range, offset, gain accuracy, and output behavior can differ. Compare the manufacturer pin-configuration and electrical-characteristics tables before substituting a part, and verify the exact ordering suffix used in the original bill of materials.
Decouple the supply pins near the package with the capacitance and layout recommended in the Texas Instruments INA122 datasheet. Keep the switching loop of any upstream converter physically separated from the input and reference connections. In a portable design, the INA122's approximately 60 µA quiescent current helps reduce static demand, but total power also depends on sensor current, output load, reference circuitry, and conversion electronics.
合規資訊
Compliance status was not established for this exact ordering code. Review the manufacturer product page, material declaration, and current quality documentation before making a compliance claim.