CD40192BD - 4-Bit Presettable BCD Up/Down Counter | TI
MPN: CD40192BD ✓ সক্রিয়CD40192BD সারাংশ
A BCD counter is a digital counter that represents each decimal digit with four binary bits. The up clock advances the count, while the down clock decrements it. Within the wider CMOS logic family, the CD40192BD belongs to the counter and divider category, combining gated D-type flip-flops with parallel jam and preset controls. Its decade organization makes it suitable when the system must directly display or represent decimal steps rather than a continuous binary sequence.
The counter provides four buffered Q outputs for the BCD digit, separate CLOCK UP and CLOCK DOWN inputs, and dedicated CARRY and BORROW outputs. Four individual jam lines allow parallel loading, while PRESET ENABLE controls whether the loaded value is transferred into the counter. These features support programmable count intervals, batch-event sequencing, decade position tracking, and repeatable operation initiated by master RESET. The snippet identifies the part as a dual-clock counter with reset.
Internally, four synchronously clocked, gated D-type flip-flops form the counting stage. Synchronous operation means the counter state advances on the active clock transition rather than through asynchronous ripple propagation. Buffered outputs provide a defined interface for downstream logic, while separate carry and borrow outputs indicate overflow beyond 9 and underflow below 0 in BCD operation. The manufacturer datasheet is the controlling reference for voltage limits, propagation timing, output drive, and environmental limits.
Typical uses include industrial decade counters, programmable timers, sequence controllers, test-equipment counters, batch-processing controls, and digital instruments that require bidirectional counting. The four Q outputs can feed a display decoder, latch, or programmable controller, while CARRY and BORROW can be combined with other counters to extend the counting range. The dual-clock architecture also permits count-up and count-down operations to be selected independently by the surrounding control logic.
When laying out a circuit, treat the clock and jam inputs as synchronous control signals and preserve the device's specified operating voltage and timing limits. Decoupling should be placed close to the supply pins, and unused inputs should be connected to a defined logic level rather than left floating. Because the D suffix denotes the surface-mount packaging option, verify the land pattern and pin orientation against the manufacturer pin description before fabrication.
This product page combines the function architecture, package details, practical counter applications, design guidance, and a parameter-focused comparison framework. It also distinguishes genuinely pin-compatible options from parts with different packages, helping engineers evaluate replacements without confusing BCD, binary, or packaging changes with true drop-in interchangeability.
এর জন্য ড্রপ-ইন বিকল্প CD40192BD — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই পণ্যের জন্য কোনো ড্রপ-ইন বিকল্প পাওয়া যায়নি।
বিকল্প অনুরোধ করুনCD40192BD সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য
| Counter Type | Presettable BCD up/down counter |
| Counting Width | 4 bit |
| Counter Elements | 1 element |
| Clock Edge | Positive edge |
| Technology | CMOS |
| Clock Inputs | 2 independent inputs: clock up and clock down |
| Output Count | 4 buffered Q outputs |
| Jam Inputs | 4 individual jam lines |
| Preset Control | 1 PRESET ENABLE input |
| Reset Control | 1 master RESET input |
| Carry Output | 1 CARRY output |
| Borrow Output | 1 BORROW output |
| প্যাকেজ | 16-pin SOIC |
| মাউন্টিং টাইপ | Surface mount |
CD40192BD পিন কনফিগারেশন
| পিন 1 | CLOCK UP — Clock input for incrementing the BCD count |
| পিন 2 | CLOCK DOWN — Clock input for decrementing the BCD count |
| পিন 3 | RESET — Master reset input |
| পিন 4 | PRESET ENABLE — Controls transfer of jam data into the counter |
| পিন 5 | Q0 — Buffered least-significant BCD output |
| পিন 6 | Q1 — Buffered BCD output |
| পিন 7 | Q2 — Buffered BCD output |
| পিন 8 | Q3 — Buffered most-significant BCD output |
| পিন 9 | CARRY — Carry output for BCD overflow indication |
| পিন 10 | BORROW — Borrow output for BCD underflow indication |
| পিন 11 | JAM 0 — Parallel jam data input for Q0 |
| পিন 12 | JAM 1 — Parallel jam data input for Q1 |
| পিন 13 | JAM 2 — Parallel jam data input for Q2 |
| পিন 14 | JAM 3 — Parallel jam data input for Q3 |
| পিন 15 | VSS — Ground reference |
| পিন 16 | VDD — Positive supply voltage |
সাধারণ ব্যবহার
CD40192BD এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Industrial Batch Counter, Digital Timer and Interval Counter, Sequence Controller, Instrumentation and Test Equipment, Bidirectional Position Tracking, Educational and Logic Prototype Circuits.
Industrial Batch Counter
The CD40192BD suits equipment that must count completed production items or process cycles in decimal format. CLOCK UP can receive a qualified sensor pulse, while the four Q outputs present the current decade count to a display decoder or controller. CARRY provides a natural event when the count advances beyond 9, and BORROW supports reverse-motion or decrementing workflows. Parallel jam inputs allow the controller to preload a starting count, while PRESET ENABLE and master RESET establish deterministic operating states. The 16-pin SOIC package supports compact control boards, but the counter's electrical and timing limits must be checked against the industrial supply and temperature requirements.
সুপারিশকৃত
Digital Timer and Interval Counter
The CD40192BD can count timed intervals in decimal form for process timers, test fixtures, and laboratory timing modules. A reference pulse routed to CLOCK UP advances the count, and the four Q outputs can feed a display driver or programmable controller that interprets tenths, seconds, or another decimal unit. CARRY permits additional stages to extend the range without requiring a central microcontroller to increment every digit. Because the counter is synchronous, state changes occur on the specified clock edge, which simplifies decoding. The design must still prevent switch bounce, contact bounce, or noisy edges from being interpreted as multiple count events.
সুপারিশকৃত
Sequence Controller
The CD40192BD provides a compact decimal state position for a programmable sequence controller. The controller can advance CLOCK UP when a stage completes, use the four jam inputs to load a specific decimal position, and monitor CARRY or BORROW to detect progression beyond a programmed range. This arrangement can coordinate gates, relays, or actuators while keeping the primary counting operation in dedicated CMOS logic. RESET returns the sequence to a known state, reducing the amount of supervisory code needed during startup. For safety-related or timing-critical equipment, validate reset dominance, clock edge behavior, and output settling using the device timing information in the manufacturer datasheet.
সুপারিশকৃত
Instrumentation and Test Equipment
The CD40192BD is useful in test and measurement equipment that presents a decimal measurement index, function step, or channel count. Its four buffered Q outputs can drive a display decoder, while jam and preset controls allow the instrument to select a measurement position. Separate carry and borrow outputs help a higher-level controller determine whether the count has moved outside the selected decade. Synchronous counting reduces uncertainty about when the output state changes relative to the active clock edge. Designers should account for input conditioning, output loading, and the propagation delay between the clock edge and valid Q, carry, or borrow information.
সুপারিশকৃত
Bidirectional Position Tracking
The CD40192BD can track a decimal position while a mechanism moves in either direction. Forward movement clocks the counter up, reverse movement clocks it down, and CARRY or BORROW indicates movement beyond the available range. This arrangement is useful in fixtures, dispensers, controlled feeders, and test systems that need a durable event count without continuously communicating with a controller. The four jam inputs let the equipment align its count with a known mechanical position after startup or homing. Mechanical switch bounce must be conditioned before reaching the clock inputs, and the reset and preset sequence should be coordinated so the displayed position never reflects a transient invalid state.
সুপারিশকৃত
Educational and Logic Prototype Circuits
The CD40192BD is well suited to laboratory exercises and logic prototypes because it exposes counting direction, preset, jam, reset, and overflow behavior in one package. Students can clock the decade counter, connect its outputs to a BCD decoder, and observe how carry and borrow support larger counting systems. The SOIC package is compact but requires a suitable PCB footprint or adapter during breadboard work. A practical training design should include a debounced clock source, defined logic states for all inputs, and a reset path that makes the displayed starting value predictable. These controls also help demonstrate the difference between decimal and binary counting in a way that is easy to probe with standard laboratory instruments.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা CD40192BD — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য |
|---|---|
| Brand | Texas Instruments |
| Package | 16-pin SOIC |
| Counter Type | Presettable BCD up/down counter |
| Counting Width | 4 bit |
| Technology | CMOS |
| Clock Edge | Positive edge |
| Clock Inputs | 2: CLOCK UP and CLOCK DOWN |
| Outputs | 4 Q outputs plus CARRY and BORROW |
| Parallel Load | 4 jam inputs with PRESET ENABLE |
| Reset | Master RESET |
মূল পার্থক্যসমূহ
- Decimal-oriented counting in a compact counter package (বনামCD40193B)
- Direction, parallel loading, and boundary indication in one device (বনামCD40192BPWR)
- Direct decimal state output for display and control logic (বনামCD40193B)
ডিজাইন নোট
Do not treat CD40192BE or CD40192BPWR as PCB drop-in alternatives for CD40192BD. The BE option uses a 16-pin through-hole package, while the BPWR option uses a 16-pin TSSOP package; neither matches the CD40192BD 16-pin SOIC land pattern. Confirm the exact package suffix against the mechanical drawing before ordering or substituting a part.
Place the supply bypass capacitor close to VDD and VSS, and keep clock and jam routing away from noisy switching nodes. Maintain short ground returns so clock edges are not distorted by shared current paths. Because the counter is synchronous, route the up and down clock signals with comparable geometry and avoid long stubs that could cause unequal propagation between related control paths.
Condition mechanical switches, relay contacts, and long sensor outputs before driving CLOCK UP or CLOCK DOWN. Contact bounce can create several apparent clock transitions and corrupt the count. Use a clean edge source or a suitable debounce circuit, and verify that the resulting pulse width satisfies the operating limits specified in the manufacturer datasheet.
Operate the counter only within the supply-voltage range and input thresholds specified for the ordered device. CMOS inputs should not be left floating because an undefined level can produce an unwanted clock transition or extra supply current. Connect every unused control input to a defined valid logic level and include the supply rails in the schematic and PCB review.
কমপ্লায়েন্স তথ্য
No definitive environmental or automotive qualification declarations are included in the manufacturer product material for this order code. The CD40192BD is a general-purpose CMOS logic counter rather than an AEC-Q100-qualified automotive device.