A CMOS counter is a synchronous digital-logic circuit that stores a multi-bit count in flip-flop stages and advances that count in response to clock edges. The CD40192 belongs to the CMOS logic IC hierarchy, where it is a specialized decade counter rather than a general-purpose binary counter. Its BCD organization means the four output bits represent the ten states from zero through nine, making it suitable for decimal displays, decade sequencing, and programmable event counting.
Each counter stage is a synchronously clocked, gated D-type flip-flop. Four individual jam inputs allow the count to be preset in parallel, while a PRESET ENABLE input controls whether those jam levels are transferred to the internal stages. Separate CLOCK UP and CLOCK DOWN inputs permit increment or decrement operation, and a master RESET input returns the counter to its zero state. Buffered Q outputs expose the four BCD count bits directly.
The CD40192BE uses complementary MOS technology and operates across a 3V to 18V supply range. The 11 MHz maximum operating frequency provides ample margin for digital control, instrumentation, and pulse-counting systems. Because it operates from a single supply, the device simplifies designs that do not require split-rail logic. Its counter output logic and separate directional clocks make it easy to build bidirectional step sequences, decade dividers, and programmable timing chains.
Typical uses include decimal counter and display modules, industrial sequencing controllers, frequency-divider chains, event counters, laboratory pulse-counting equipment, and embedded control systems that interface mechanical switches or sensors to digital logic. It is particularly useful when a project needs true BCD counting rather than binary counting, since binary-to-decimal conversion can be avoided in LED display applications.
When designing around the CD40192BE, keep clock traces short and isolate switching or inductive sources from the counter inputs. Decoupling capacitors should be placed close to the supply pins, and unused input pins must be tied to a defined logic level. Confirm that the required count direction and preset behavior match the intended jam and preset-enable logic before laying out the circuit.
This page combines manufacturer specifications, verified distributor listings, pin-level implementation guidance, and function-level comparisons with available 16-pin CMOS counter alternatives. It also identifies where the CD40192BE should not be selected, such as designs that require binary counting or a surface-mount footprint.
Drop-in alternatives for CD40192BE — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
CD40192BCN
✅ Drop-In📋 Reference alternative (not in catalog)
HCF40192BE
✅ Drop-In📋 Reference alternative (not in catalog)
HEF40192BP
✅ Drop-In📋 Reference alternative (not in catalog)
MC140192BCP
✅ Drop-In📋 Reference alternative (not in catalog)
TC40192BP
✅ Drop-In📋 Reference alternative (not in catalog)
CD40192BE Maximum Ratings & Electrical Characteristics
| Counter Type | 4-bit presettable BCD up/down counter |
| Logic Family | CMOS |
| Supply Voltage Range | 3 V to 18 V |
| Maximum Clock Frequency | 11 MHz |
| Number of Count Elements | 4 |
| Counting Sequence | BCD decade, 0 to 9 |
| Clock Edge | Positive edge |
| Clock Inputs | Separate clock up and clock down inputs |
| Jam Inputs | 4 individual jam inputs |
| Preset Control | PRESET ENABLE control input |
| Reset | Master RESET input |
| Counter Outputs | 4 buffered Q outputs |
| Carry Output | CARRY output |
| Borrow Output | BORROW output |
| Internal Counter Stage | 4 synchronously clocked gated D-type flip-flops |
| Package | PDIP (N), 16 pins |
| Mounting Type | Through-hole |
CD40192BE Pin Configuration
| Pin 1 | CLOCK UP — Positive-edge clock input for counting upward |
| Pin 2 | CLOCK DOWN — Positive-edge clock input for counting downward |
| Pin 3 | RESET — Master reset input |
| Pin 4 | PRESET ENABLE — Control input for the jam or preset function |
| Pin 5 | JAM 0 — Parallel jam input for counter bit 0 |
| Pin 6 | JAM 1 — Parallel jam input for counter bit 1 |
| Pin 7 | JAM 2 — Parallel jam input for counter bit 2 |
| Pin 8 | JAM 3 — Parallel jam input for counter bit 3 |
| Pin 9 | Q 0 — Buffered BCD count output, least significant bit |
| Pin 10 | Q 1 — Buffered BCD count output |
| Pin 11 | Q 2 — Buffered BCD count output |
| Pin 12 | Q 3 — Buffered BCD count output, most significant bit |
| Pin 13 | CARRY — Carry output for upward counting |
| Pin 14 | BORROW — Borrow output for downward counting |
| Pin 15 | VSS — Ground reference |
| Pin 16 | VDD — Positive supply input |
Typical Applications
CD40192BE is suitable for 6 applications: Decimal Counter and LED Display, Industrial Pulse and Event Counting, Programmable Step Sequencer, Frequency Divider and Decade Chain, Laboratory and Test Instrumentation, Directional Control and Bidirectional Counters.
Decimal Counter and LED Display
The CD40192BE is well suited to decimal display sequencing because its four outputs represent BCD values from 0 to 9 rather than binary states from 0 to 15. Each positive edge on CLOCK UP advances one decade, while CLOCK DOWN reverses the sequence. The buffered Q outputs can drive display-decoder inputs or a multiplexed LED display controller. The separate CARRY and BORROW outputs also permit additional CD40192 stages to form larger decimal counting chains. Designers should account for propagation delay when cascading stages and should confirm that the selected display decoder accepts the counter's BCD output format.
Recommended
Industrial Pulse and Event Counting
The CD40192BE provides a compact decimal event-counting function for industrial control systems that must accumulate pulses from switches, sensors, or machine events. Its separate directional clock inputs allow the count to be incremented or decremented by the same interface, while the master RESET clears the total and the jam inputs support parallel loading. With operation specified across 3V to 18V, the counter can be used with legacy 5V industrial logic as well as newer control rails. In noisy installations, shield the clock path and use filtering or Schmitt-trigger conditioning before allowing external events to drive the counter inputs.
Recommended
Programmable Step Sequencer
The CD40192BE can implement a compact programmable decade sequencer by combining its BCD count outputs with preset and reset control. A preset value loaded through the four jam inputs establishes the starting state, and successive clock-up edges move through the remaining decimal positions. Logic decoding of the four Q outputs can then select which output device or process stage is active. The 11 MHz maximum operating rate leaves substantial timing headroom for ordinary control sequences, but actual delay includes counter propagation time and any decoding gates. The design should prevent simultaneous activity on the up and down clock inputs to maintain an unambiguous count direction.
Recommended
Frequency Divider and Decade Chain
The CD40192BE can divide an incoming event stream into predictable decimal intervals, making it useful in timing, test, and repetitive-sequence systems. CARRY indicates a forward count transition at the end of a decade, while BORROW provides the corresponding indication during downward counting. These outputs may be used to trigger a parallel counter stage or a divider of the same family. Since each stage introduces propagation delay, cascaded designs should be checked for cumulative timing offset at the operating frequency. The device's 11 MHz capability is substantially above the rates normally required for basic decade division.
Recommended
Laboratory and Test Instrumentation
In laboratory instrumentation, the CD40192BE can count test pulses and present a decimal total rather than requiring binary-to-decimal conversion. Its master reset provides a repeatable measurement start, while the jam inputs permit a known preset count for calibration or offset correction. The buffered Q outputs offer a convenient logic-level interface to external display or measurement equipment. Because the counter responds to positive clock edges, source conditioning should preserve clean edge transitions and avoid double counting. For low-noise analog measurement systems, keep the counter and its clock source physically separated from high-impedance analog nodes to minimize coupling.
Recommended
Directional Control and Bidirectional Counters
The CD40192BE is useful when a system must count in either direction without changing the counter's counting base. A forward command pulses CLOCK UP, while a reverse command pulses CLOCK DOWN; the resulting BCD count appears on the four Q outputs. This arrangement simplifies mechanical joggers, position indicators, and reversible event counters compared with a design that needs a separate direction-control multiplexer. Firmware or external logic must ensure that both clocks are never asserted together. CARRY and BORROW provide boundary events that can be used to detect the ends of the decimal range or coordinate a multi-digit display.
Recommended
Recommended Products Summary
Engineering reference data for CD40192BE — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | CD40192BCN | HCF40192BE | HEF40192BP | MC140192BCP | TC40192BP |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | onsemi | STMicroelectronics | NXP Semiconductors | onsemi | Toshiba |
| Package | PDIP-16 | PDIP-16 | PDIP-16 | PDIP-16 | PDIP-16 | PDIP-16 |
| Counter Function | Presettable BCD up/down counter | Presettable BCD up/down counter | BCD up/down counter | BCD up/down counter | BCD up/down counter | BCD up/down counter |
| Number of Count Elements | 4 bits | 4 bits | 4 bits | 4 bits | 4 bits | 4 bits |
| Counting Sequence | BCD, 0 to 9 | BCD, 0 to 9 | BCD, 0 to 9 | BCD, 0 to 9 | BCD, 0 to 9 | BCD, 0 to 9 |
| Clock Direction Inputs | Separate clock up and clock down inputs | Separate clock up and clock down inputs | Separate clock up and clock down inputs | Separate clock up and clock down inputs | Separate clock up and clock down inputs | Separate clock up and clock down inputs |
| Preset and Jam Control | 4 jam inputs with PRESET ENABLE control | 4 jam inputs with PRESET ENABLE control | 4 jam inputs with PRESET ENABLE control | 4 jam inputs with PRESET ENABLE control | 4 jam inputs with PRESET ENABLE control | 4 jam inputs with PRESET ENABLE control |
| Output Functions | 4 buffered Q outputs plus CARRY and BORROW | 4 Q outputs plus CARRY and BORROW | 4 Q outputs plus CARRY and BORROW | 4 Q outputs plus CARRY and BORROW | 4 Q outputs plus CARRY and BORROW | 4 Q outputs plus CARRY and BORROW |
| Logic Technology | CMOS | CMOS | CMOS | CMOS | CMOS | CMOS |
Key Differentiators
- Direct BCD decade output for decimal display and sequencing (vs CD40193BE)
- Independent directional counting in one counter (vs CD40193BE)
- Broad single-supply operating range (vs HCF40192BE)
Design Notes
Place the supply bypass capacitor directly between pins 16 and 15, with the ground end connected to a low-impedance return plane. CMOS counters can switch their internal clock nodes quickly, so adequate local decoupling reduces supply transients that might appear on clock or preset pins. Use separate routing for the supply and jam inputs, and avoid sharing a narrow trace between sensitive analog nodes and counter output signals.
Keep the CLOCK UP and CLOCK DOWN traces short and provide a defined state for each input when it is not being driven. Because the counter reacts to positive edges, slow or noisy source transitions can produce multiple counts. For switches, sensors, or long wires, use a conditioning stage with hysteresis before connecting the signal to a clock input. Do not allow both directional clocks to pulse simultaneously.
Confirm that the required count base is BCD rather than binary before selecting CD40192BE over the CD40193 family. During normal counting, PRESET ENABLE must remain inactive, and the jam inputs should not inadvertently disturb the loaded count. For cascaded decimal stages, include the propagation delay of each stage in the timing budget and use CARRY or BORROW for the intended chaining direction.