INA118UG4 - 800 kHz Low-Power Instrumentation Amplifier | Texas Instruments
MPN: INA118UG4 ✓ সক্রিয়INA118UG4 সারাংশ
An instrumentation amplifier is a differential amplifier optimized for amplifying a small voltage difference between two inputs while rejecting signals common to both inputs. Its hierarchy includes instrumentation amplifier, differential amplifier, analog amplifier, and integrated circuit. This application-specific architecture is more useful than a general-purpose op amp when the source is a low-level bridge, strain gauge, thermocouple, or current-sense element surrounded by substantial common-mode voltage.
Key features include a three-op-amp internal architecture, current-feedback input circuitry, 800 kHz bandwidth, 25 uV input offset voltage, and 98 dB CMRR. A single external resistor establishes gains from 1 to 10,000, simplifying circuit configuration while retaining the internal resistor matching needed for accurate differential gain. The low-power design also supports portable and compact measurement systems that cannot accommodate a large analog signal chain.
The current-feedback input stage preserves useful bandwidth at high closed-loop gain. According to the Texas Instruments INA118 product information, bandwidth remains 70 kHz at a gain of 100, an important consideration for systems that must preserve sensor-response speed without operating at unity gain. Supply operation from ±1.35 V to ±18 V permits use in both compact dual-rail systems and conventional analog power rails up to ±15 V typical.
Typical applications include bridge-based pressure and load-cell measurement, low-voltage current sensing, isolated sensor interfaces, biomedical instrumentation, and industrial process monitoring. INA118UG4 is particularly appropriate when differential signal integrity matters more than absolute accuracy at low cost, because its internal three-op-amp design provides matched gain resistors and high common-mode rejection in one package.
Designers should verify common-mode input range, output swing, supply polarity, and gain-bandwidth requirements at the actual operating voltage. A precision gain resistor, stable reference potential, and careful grounding of the reference and supply-return pins are important for low-offset measurements. Decoupling capacitors should be placed close to the supply pins using a layout that minimizes sensitive input-node coupling.
This product page consolidates the INA118UG4 electrical characteristics, family replacements, application guidance, and practical design considerations into an engineering-focused selection resource. It also distinguishes direct family drop-ins from broader functional alternatives so designers can reuse a PCB only after verifying package dimensions, pinout, supply range, and gain-setting behavior.
এর জন্য ড্রপ-ইন বিকল্প INA118UG4 — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই সিরিজের ভ্যারিয়েন্ট
একই সিরিজের মডেল যেগুলো drop-in compatible INA118UG4 (একই form factor এবং footprint) — পার্থক্য রয়েছে Package, Gain Range, Input Offset Voltage, Number of Circuits, Operating Temperature Range.
INA118U
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA118UB
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA118UBG4
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA118UA
✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
INA118UG4 সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য
| Product Type | Precision low-power instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Amplifier Architecture | Three-op-amp architecture |
| Small-Signal Bandwidth | 800 kHz |
| Bandwidth at Gain 100 | 70 kHz |
| Input Offset Voltage | 25 uV |
| Common-Mode Rejection Ratio | 98 dB |
| Gain Range | 1 to 10,000 |
| Gain Configuration | One external resistor |
| Input Circuitry | Current-feedback |
| Minimum Total Supply Voltage | ±1.35 V |
| Typical Dual Supply Voltage | ±15 V |
| Maximum Total Supply Voltage | ±18 V |
| Minimum Operating Temperature | -40 °C |
| প্যাকেজ | 8-SOIC |
| Package Width | 3.90 mm |
| Package Pitch | 1.27 mm |
INA118UG4 পিন কনফিগারেশন
| পিন 1 | RG — External gain resistor connection |
| পিন 2 | IN- — Inverting input |
| পিন 3 | IN+ — Noninverting input |
| পিন 4 | V- — Negative supply connection |
| পিন 5 | REF — Reference input |
| পিন 6 | OUT — Amplified output |
| পিন 7 | V+ — Positive supply connection |
| পিন 8 | RG — External gain resistor connection |
সাধারণ ব্যবহার
INA118UG4 এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Strain-Gauge Bridge Measurement, Precision Current Sensing, Medical and Biosignal Front Ends, Thermocouple Measurement, Industrial Process Sensing, Portable Instrumentation.
Strain-Gauge Bridge Measurement
The INA118UG4 fits strain-gauge and load-cell front ends that produce a small differential signal on a substantial common-mode voltage. Its 25 uV input offset and 98 dB CMRR help preserve the integrity of the bridge output, while the three-op-amp architecture provides matched gain resistors in an 8-SOIC package. One external resistor sets gain from 1 to 10,000, simplifying range adjustment. For slowly varying loads, use the full 800 kHz device bandwidth only when necessary, and verify the bridge excitation voltage, common-mode range, and output swing before fixing the gain.
সুপারিশকৃত
Precision Current Sensing
The INA118UG4 is appropriate for low-side or isolated current-sense circuits where a small differential voltage must be amplified in the presence of a larger common-mode voltage. A 25 uV offset is useful near the measurement floor, and 98 dB CMRR suppresses supply and ground disturbances that appear equally on both inputs. The 8-SOIC package reduces board area, while the 1-to-10,000 gain range supports both millivolt and sub-millivolt sense elements. Confirm that the shunt common-mode voltage remains inside the amplifier limits and that the amplified output does not saturate the supply rails.
সুপারিশকৃত
Medical and Biosignal Front Ends
The INA118UG4 can condition low-level differential bio-sensor signals when the design requires better common-mode rejection than a general-purpose op-amp network provides. Its 98 dB CMRR reduces interference from physiological excitation or shared ground paths, and the 25 uV offset supports high-gain measurement stages. The single-resistor gain setting from 1 to 10,000 makes it practical to match the input range to a sensor interface. Medical designs must additionally address patient protection, isolation, leakage current, electrode compliance, and applicable safety requirements outside the device's basic analog specifications.
সুপারিশকৃত
Thermocouple Measurement
The INA118UG4 is suitable for precision thermocouple interfaces because the thermocouple produces a low-level differential voltage and the amplifier offers 25 uV offset with 98 dB CMRR. An external gain resistor allows the circuit to cover different thermocouple sensitivities, while the 8-SOIC package supports compact multi-channel measurement boards. The principal design constraints are cold-junction compensation, input protection, wiring error, and thermoelectric leakage. Verify the common-mode voltage during startup and ensure the selected gain does not saturate the output while the thermocouple is disconnected or exposed to temperature extremes.
সুপারিশকৃত
Industrial Process Sensing
The INA118UG4 supports industrial process-measurement modules that combine a low-level sensor with controller-based data acquisition. The 98 dB CMRR is useful when sensor wiring introduces common-mode pickup, and the three-op-amp architecture reduces the need for separate precision gain networks. With gain adjustable from 1 to 10,000 and bandwidth up to 800 kHz, the device accommodates slow process variables and faster dynamic sensors. Protect the input path from industrial transients, isolate analog ground currents carefully, and confirm that the operating-temperature grade and lifecycle status satisfy the deployment environment.
সুপারিশকৃত
Portable Instrumentation
The INA118UG4 suits portable measurement equipment where a three-op-amp instrumentation amplifier must occupy little board area without relying on discrete precision networks. The 8-SOIC package, single external gain resistor, and 25 uV offset support compact sensor interfaces, while 98 dB CMRR helps reject interference from nearby digital and switching circuitry. Low-power operation also makes the device relevant to battery-powered instruments. Battery life still depends on total supply current, regulator efficiency, duty cycle, and the selected gain, so evaluate those parameters at system level rather than inferring consumption from the amplifier's bandwidth alone.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা INA118UG4 — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | INA118U | INA118UB | INA118UBG4 | INA118UA |
|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-SOIC | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same |
| Product Type | Precision low-power instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier |
| Gain Range | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 |
| Architecture | Three-op-amp with current-feedback inputs | INA118 family architecture | INA118 family architecture | INA118 family architecture | INA118 family architecture |
মূল পার্থক্যসমূহ
- Compact complete differential gain stage (বনামINA118U)
- High common-mode rejection for differential sensing (বনামINA118UBG4)
- Useful bandwidth at elevated gain (বনামINA118UB)
ডিজাইন নোট
Route the IN- and IN+ connections as a compact, symmetric differential pair and keep them away from switching nodes, relay contacts, and high-current return paths. Place the external gain resistor close to the RG pins, and connect the REF bypass capacitor directly to the reference pin with a short ground return. The differential inputs are high-impedance nodes, so leaked PCB contamination or flux residue can create an offset larger than the 25 uV input specification.
Check the actual input common-mode voltage and output swing against the selected supply rails; the ±1.35 V to ±18 V operating range does not imply rail-to-rail input or output behavior. Use a quiet, low-noise supply for sensitive measurements and place supply-decoupling capacitors close to V+ and V-. If a regulated supply introduces ripple, verify its attenuation at the selected gain rather than assuming that the 98 dB CMRR specification alone removes all in-band noise.
A common design mistake is treating the INA118 as a unity-gain op amp and ignoring the relationship among external gain resistance, gain, bandwidth, and output range. Gain is set by one resistor, but the selected resistor must match the intended gain and remain stable over temperature. Also ground the REF pin appropriately rather than leaving it floating. Verify the exact package lead geometry and pin numbering against the manufacturer drawing before releasing PCB artwork.
কমপ্লায়েন্স তথ্য
Exact-order compliance attributes were not established by the listed product and comparison pages. Check the Texas Instruments product documentation and applicable material declarations before making a compliance claim.