INA125PAG4 - Precision Instrumentation Amplifier | Texas Instruments
MPN: INA125PAG4 ✓ সক্রিয়INA125PAG4 সারাংশ
An instrumentation amplifier is a specialized amplifier category designed to provide high input impedance, accurate differential gain, and excellent rejection of common-mode signals. This is especially important when a small sensor differential voltage is measured in the presence of a much larger common-mode voltage. The INA125PAG4 provides the internal gain network and precision reference needed for complete bridge excitation and signal conditioning, reducing the number of external precision components required in a measurement front end.
The principal benefits of this device include integrated precision voltage-reference capability, differential input architecture, programmable gain using external resistors, and a single-ended output suitable for connection to analog-to-digital converters or control systems. The device is identified as a 1-circuit instrumentation amplifier in a 16-PDIP package. Its input offset voltage is listed as 500 microvolts, and its bandwidth is listed as 150 kHz. These characteristics support moderate-bandwidth industrial measurement systems where accurate signal amplification is more important than very high-speed conversion.
The INA125 family is suitable for applications involving resistive bridges and other small differential signals. The integrated reference can provide a stable excitation voltage for a bridge, while the instrumentation amplifier rejects common-mode voltage and applies a selected gain to the differential sensor output. Designers should account for the input common-mode range, output voltage swing, reference accuracy, resistor tolerance, and supply requirements when selecting the operating gain and external network.
Typical uses include industrial process monitoring, load-cell signal conditioning, strain-gauge bridges, pressure transducers, laboratory instrumentation, and embedded data-acquisition systems. In a bridge circuit, the transducer changes resistance according to the measured physical quantity, creating a differential voltage that the INA125PAG4 amplifies relative to the supplied excitation. The resulting analog signal can then be sampled by an ADC after appropriate filtering and level adjustment.
For PCB implementation, use a clean analog ground strategy, route the differential input pair as a tightly matched pair, and keep the gain-setting and reference-related components close to the device. Verify the actual supply, common-mode, output-swing, and gain limits against the manufacturer datasheet before releasing the design. The DIP package also provides generous pin spacing for prototyping and through-hole assembly, although a surface-mount package is preferable when board area or production routing is a primary constraint.
This page provides a structured view of the INA125PAG4's instrumentation-amplifier role, package characteristics, verified operating highlights, application guidance, and design considerations. It is intended to help engineers evaluate the device for bridge-sensing and precision analog measurement systems without overlooking the electrical limits that determine gain, bandwidth, and signal integrity.
এর জন্য ড্রপ-ইন বিকল্প INA125PAG4 — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই সিরিজের ভ্যারিয়েন্ট
একই সিরিজের মডেল যেগুলো drop-in compatible INA125PAG4 (একই form factor এবং footprint) — পার্থক্য রয়েছে Package, Product Type, Quiescent Current.
INA125P
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA125PA
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA125PAG4 সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য
| Device Type | Single-circuit instrumentation amplifier |
| Integrated Voltage Reference | Yes |
| Input Type | Differential |
| আউটপুট টাইপ | Single-ended |
| Number of Amplifiers | 2 |
| Input Offset Voltage | 500 microvolts |
| Bandwidth | 150 kHz |
| প্যাকেজ | 16-PDIP, through-hole |
| Number of Terminals | 16 |
| Package Shape | Rectangular |
| Temperature Grade | Industrial |
| মাউন্টিং টাইপ | Through-hole |
INA125PAG4 rectangular পিন কনফিগারেশন গাইড
INA125PAG4 (rectangular প্যাকেজ)-এর পিন কনফিগারেশন। এই অ্যানালগ কম্পোনেন্টে ইনপুট, আউটপুট ও পাওয়ার সাপ্লাই পিন রয়েছে। অফসেট নাল, কম্পেনসেশন ও এনেবল পিন কনফিগারেশনের জন্য প্রস্তুতকারকের ডেটাশিট দেখুন। সিগন্যাল কন্ডিশনিং ও অ্যামপ্লিফায়ার সার্কিটের জন্য আদর্শ।
এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি INA125PAG4.
দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।
সাধারণ ব্যবহার
INA125PAG4 এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Load-Cell Signal Conditioning, Pressure Transducer Interface, Strain-Gauge Measurement, Industrial Process Monitoring, Laboratory Data-Acquisition, Precision Voltage Reference Output.
Load-Cell Signal Conditioning
The INA125PAG4 is suitable for conditioning the small differential output of a resistive load cell because it combines differential amplification with an integrated precision reference for bridge excitation. The 500 microvolt input offset and 150 kHz bandwidth provide a practical starting point for static force and weight measurement. Place the amplifier close to the bridge and use a matched, shielded differential route to reduce pickup from motors, switching supplies, and adjacent digital circuitry.
সুপারিশকৃত
Pressure Transducer Interface
A resistive pressure transducer benefits from the INA125PAG4's integrated reference and differential input stage because sensor excitation and signal amplification can be handled in one controlled analog section. The 150 kHz bandwidth supports many process-monitoring signals without requiring a high-speed instrumentation amplifier. Calibration should include zero offset, span, reference accuracy, bridge tolerance, and the input offset specified for the device.
সুপারিশকৃত
Strain-Gauge Measurement
The INA125PAG4 can amplify the differential output of a strain-gauge bridge while rejecting common-mode voltage that may be much larger than the sensor signal. Its 500 microvolt input offset is relevant when the selected gain multiplies small strains into a small output voltage. Use stable excitation, low-noise reference grounding, careful resistor selection, and a mechanical design that minimizes parasitic strain and temperature gradients.
সুপারিশকৃত
Industrial Process Monitoring
The INA125PAG4 is appropriate for industrial process-monitoring modules that accept low-level differential sensor signals and require an integrated excitation source. The 16-pin DIP package is convenient for prototype boards and through-hole industrial assemblies. For field reliability, isolate noisy inputs, provide filtering, maintain a clean analog return path, and verify the complete supply and common-mode limits in the manufacturer datasheet.
সুপারিশকৃত
Laboratory Data-Acquisition
The INA125PAG4 can provide the analog front end for laboratory data-acquisition systems using resistive dividers, strain gauges, or other bridge sensors. Its single-ended output is compatible with a general-purpose ADC input when the output range is scaled appropriately. The 150 kHz bandwidth is suitable for many slowly varying or moderately sampled measurements, while calibration and connector design determine achievable laboratory accuracy.
সুপারিশকৃত
Precision Voltage Reference Output
Because the INA125 includes a precision voltage reference, it can support measurement systems that need both differential signal conditioning and a stable excitation or reference node. The reference output should be checked against the datasheet's specified accuracy, drift, load capability, and decoupling requirements. Avoid using the reference terminal to power unrelated loads, and keep its return path close to the device ground.
সুপারিশকৃত
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা INA125PAG4 — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | INA125P | INA125PA |
|---|---|---|---|
| Device Type | Instrumentation amplifier with precision voltage reference | INA125-family instrumentation amplifier | INA125-family instrumentation amplifier |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit |
| Integrated Voltage Reference | Yes | Yes | Yes |
| Package | 16-PDIP | 16-PDIP | 16-PDIP |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Mounting Type | Through-hole | Through-hole | Through-hole |
| Input Configuration | Differential input | Differential input | Differential input |
মূল পার্থক্যসমূহ
- Integrated precision reference in the same instrumentation-amplifier package (বনামINA125P)
- Differential signal conditioning with 500 microvolt input offset (বনামINA125PA)
- Through-hole industrial DIP implementation (বনামINA125P)
ডিজাইন নোট
Route the differential sensor inputs as a close, matched pair and connect the amplifier ground to the quiet analog-ground system. Keep the INA125PAG4 close to the bridge or sensor connector so that cable pickup is minimized before amplification. Place the input filtering and gain-setting components near the relevant pins, and avoid routing sensitive input traces beneath switching-regulator or digital-clock areas.
Do not select the gain solely from the nominal bridge output range. The maximum input differential voltage, common-mode range, output swing, supply voltage, reference load capability, and bandwidth all change with gain and operating conditions. Verify these limits in the INA125 datasheet, and include offset, gain error, drift, reference accuracy, and resistor tolerance in the measurement uncertainty budget.
For long sensor cables, use suitable input filtering and guarding rather than relying on the amplifier alone to reject noise. Maintain symmetric input paths, provide a stable analog reference return, and keep the reference node free from unwanted loading. When the signal bandwidth is close to the listed 150 kHz value, check gain-dependent bandwidth and output-swing behavior before selecting the final filter bandwidth.
The 16-pin DIP package is straightforward to assemble but does not minimize board area. Preserve the manufacturer's recommended decoupling connections and place them directly between the supply and ground pins. Keep the analog signal path away from the package's unused or adjacent digital-capable pins, and follow the datasheet pin configuration when assigning every net to avoid reversed power or reference connections.
কমপ্লায়েন্স তথ্য
The available product excerpts identify the INA125 as a Texas Instruments industrial instrumentation amplifier but do not provide explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statements.