INA125PAG4 Tóm tắt

The Texas Instruments INA125PAG4 is a single-circuit instrumentation amplifier with an integrated precision voltage reference, designed for accurate differential-input amplification and bridge excitation. The device combines a low-noise amplifier core, matched input stages, gain-setting resistors, and a reference output in one integrated circuit, making it useful for pressure, load-cell, strain-gauge, and other bridge-based measurement systems. The INA125PAG4 is offered in a 16-pin through-hole DIP package for industrial temperature-grade applications.

An instrumentation amplifier is a specialized amplifier category designed to provide high input impedance, accurate differential gain, and excellent rejection of common-mode signals. This is especially important when a small sensor differential voltage is measured in the presence of a much larger common-mode voltage. The INA125PAG4 provides the internal gain network and precision reference needed for complete bridge excitation and signal conditioning, reducing the number of external precision components required in a measurement front end.

The principal benefits of this device include integrated precision voltage-reference capability, differential input architecture, programmable gain using external resistors, and a single-ended output suitable for connection to analog-to-digital converters or control systems. The device is identified as a 1-circuit instrumentation amplifier in a 16-PDIP package. Its input offset voltage is listed as 500 microvolts, and its bandwidth is listed as 150 kHz. These characteristics support moderate-bandwidth industrial measurement systems where accurate signal amplification is more important than very high-speed conversion.

The INA125 family is suitable for applications involving resistive bridges and other small differential signals. The integrated reference can provide a stable excitation voltage for a bridge, while the instrumentation amplifier rejects common-mode voltage and applies a selected gain to the differential sensor output. Designers should account for the input common-mode range, output voltage swing, reference accuracy, resistor tolerance, and supply requirements when selecting the operating gain and external network.

Typical uses include industrial process monitoring, load-cell signal conditioning, strain-gauge bridges, pressure transducers, laboratory instrumentation, and embedded data-acquisition systems. In a bridge circuit, the transducer changes resistance according to the measured physical quantity, creating a differential voltage that the INA125PAG4 amplifies relative to the supplied excitation. The resulting analog signal can then be sampled by an ADC after appropriate filtering and level adjustment.

For PCB implementation, use a clean analog ground strategy, route the differential input pair as a tightly matched pair, and keep the gain-setting and reference-related components close to the device. Verify the actual supply, common-mode, output-swing, and gain limits against the manufacturer datasheet before releasing the design. The DIP package also provides generous pin spacing for prototyping and through-hole assembly, although a surface-mount package is preferable when board area or production routing is a primary constraint.

This page provides a structured view of the INA125PAG4's instrumentation-amplifier role, package characteristics, verified operating highlights, application guidance, and design considerations. It is intended to help engineers evaluate the device for bridge-sensing and precision analog measurement systems without overlooking the electrical limits that determine gain, bandwidth, and signal integrity.

Bộ thay thế dễ dàng lắp đặt cho INA125PAG4 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA125PAG4 (cùng hình factor và footprint) — khác nhau ở Package, Product Type, Quiescent Current.

Texas Instruments
Package: 16-pin plastic DIP, through-hole
Product Type: Instrumentation amplifier with precision voltage reference
Quiescent Current: 460 µA typical
So sánh với INA125PAG4 →
Texas Instruments
Package: 16-pin PDIP
Product Type: Single-channel instrumentation amplifier with precision voltage reference
Quiescent Current: 460 µA
So sánh với INA125PAG4 →

INA125P

✅ Drop-In
Texas Instruments
📦 16-PDIP
Instrumentation amplifier with precision voltage reference · 1 circuit · 250 µV · 2 µV/°C · 0.02 V/µs · 150 kHz · 2.7 V to 36 V · 460 µA typical

Liên hệ để biết giá

Xem tài liệu →

INA125PA

✅ Drop-In
Texas Instruments
📦 16-PDIP
Single-channel instrumentation amplifier with precision voltage reference · 1 circuit · 4 to 10,000 · Single external resistor · 10 V · 1.35 V to 18 V · 460 µA · 250 µV maximum

Liên hệ để biết giá

Xem tài liệu →

INA125PAG4 Tỷ lệ tối đa & tính chất điện

Device Type Single-circuit instrumentation amplifier
Integrated Voltage Reference Yes
Input Type Differential
Kiểu đầu ra Single-ended
Number of Amplifiers 2
Input Offset Voltage 500 microvolts
Bandwidth 150 kHz
Hộp 16-PDIP, through-hole
Number of Terminals 16
Package Shape Rectangular
Temperature Grade Industrial
Kiểu lắp đặt Through-hole

Hướng dẫn cấu hình chân INA125PAG4 rectangular

Cấu hình chân cho INA125PAG4 (rectangular gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.

Bảng cấu hình chân rectangular cho INA125PAG4

Không có dữ liệu chân cụ thể sẵn có cho INA125PAG4.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

INA125PAG4 phù hợp cho 6 Áp dụngs: Load-Cell Signal Conditioning, Pressure Transducer Interface, Strain-Gauge Measurement, Industrial Process Monitoring, Laboratory Data-Acquisition, Precision Voltage Reference Output.

⚡

Load-Cell Signal Conditioning

The INA125PAG4 is suitable for conditioning the small differential output of a resistive load cell because it combines differential amplification with an integrated precision reference for bridge excitation. The 500 microvolt input offset and 150 kHz bandwidth provide a practical starting point for static force and weight measurement. Place the amplifier close to the bridge and use a matched, shielded differential route to reduce pickup from motors, switching supplies, and adjacent digital circuitry.

🏭

Pressure Transducer Interface

A resistive pressure transducer benefits from the INA125PAG4's integrated reference and differential input stage because sensor excitation and signal amplification can be handled in one controlled analog section. The 150 kHz bandwidth supports many process-monitoring signals without requiring a high-speed instrumentation amplifier. Calibration should include zero offset, span, reference accuracy, bridge tolerance, and the input offset specified for the device.

📱

Strain-Gauge Measurement

The INA125PAG4 can amplify the differential output of a strain-gauge bridge while rejecting common-mode voltage that may be much larger than the sensor signal. Its 500 microvolt input offset is relevant when the selected gain multiplies small strains into a small output voltage. Use stable excitation, low-noise reference grounding, careful resistor selection, and a mechanical design that minimizes parasitic strain and temperature gradients.

🏭

Industrial Process Monitoring

The INA125PAG4 is appropriate for industrial process-monitoring modules that accept low-level differential sensor signals and require an integrated excitation source. The 16-pin DIP package is convenient for prototype boards and through-hole industrial assemblies. For field reliability, isolate noisy inputs, provide filtering, maintain a clean analog return path, and verify the complete supply and common-mode limits in the manufacturer datasheet.

🖥️

Laboratory Data-Acquisition

The INA125PAG4 can provide the analog front end for laboratory data-acquisition systems using resistive dividers, strain gauges, or other bridge sensors. Its single-ended output is compatible with a general-purpose ADC input when the output range is scaled appropriately. The 150 kHz bandwidth is suitable for many slowly varying or moderately sampled measurements, while calibration and connector design determine achievable laboratory accuracy.

🔧

Precision Voltage Reference Output

Because the INA125 includes a precision voltage reference, it can support measurement systems that need both differential signal conditioning and a stable excitation or reference node. The reference output should be checked against the datasheet's specified accuracy, drift, load capability, and decoupling requirements. Avoid using the reference terminal to power unrelated loads, and keep its return path close to the device ground.

What is the INA125PAG4?
The INA125PAG4 is a single-circuit, precision instrumentation amplifier with an integrated voltage reference, packaged in a 16-pin DIP. According to the Texas Instruments product description, it combines bridge excitation and precision differential-input amplification in one integrated circuit. It is intended for resistive-bridge and other low-level differential measurement systems.
What is the operating voltage range of INA125PAG4?
The INA125PAG4 operating supply range is listed in the Texas Instruments datasheet, but the supplied product excerpts do not state the numeric minimum and maximum voltages. Use the Electrical Characteristics table in the manufacturer datasheet to confirm the supply limits before design release. The supply choice must also support the required output swing, input common-mode range, and reference behavior.
What are the key specifications of INA125PAG4 that engineers should know?
The INA125PAG4 combines a 1-circuit instrumentation amplifier, an integrated precision voltage reference, differential inputs, and a single-ended output in a 16-PDIP package. The available component data identifies 500 microvolts of input offset voltage and 150 kHz bandwidth. The manufacturer describes the device as a low-power, high-accuracy bridge-excitation and differential-amplification solution.
Where can I download the INA125PAG4 datasheet PDF?
The official INA125PAG4 datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina125.pdf. The same document covers the INA125 family, including electrical characteristics, gain configuration, reference behavior, pin descriptions, typical application circuits, and package information. Use the ordering information in the datasheet to confirm that the INA125PAG4 suffix corresponds to the industrial 16-pin DIP configuration.
Where can I find the INA125PAG4 pinout?
The INA125PAG4 pinout is shown in the Pin Configuration and Typical Application Circuit sections of the Texas Instruments INA125 datasheet. Because the exact pin-by-pin table is not included in the available product excerpts, use the manufacturer diagram to assign signal names and package orientation. Confirm every connection against the datasheet rather than relying on a generic 16-pin DIP drawing.
Can INA125PAG4 measure load cells and strain gauges?
Yes, the INA125PAG4 is well suited to load-cell and strain-gauge front ends because it combines differential input amplification with a precision voltage reference for bridge excitation. The 500 microvolt input offset and 150 kHz bandwidth are appropriate for many static and moderate-dynamic measurement systems. Mechanical and thermal design, input filtering, and calibration remain necessary for high-accuracy results.
What is the difference between INA125PAG4 and INA125PA?
The INA125PAG4 and INA125PA are both identified as INA125-family instrumentation amplifiers, but their orderable suffix and package details must be checked in the ordering table. The INA125PAG4 is confirmed as a 16-pin industrial DIP ordering. Because the available excerpts do not reproduce the complete suffix matrix, verify the exact temperature grade, lead style, and performance limits before treating one as a substitution.
Is INA125PAG4 the same as INA125P?
The INA125PAG4 and INA125P are closely related INA125 orderable versions, and both are associated with the 16-pin DIP family in the available comparison information. They should not be treated as automatically identical without checking the manufacturer ordering table, because suffix codes can indicate grade, lead style, or packaging differences. Verify the full ordering information and datasheet parameters before substitution.
What is the best drop-in replacement for INA125PAG4?
The INA125PAG4 is best replaced by an orderable INA125-family device that retains the same 16-pin DIP footprint, pin functions, supply limits, gain network, and reference configuration. The available cross-reference information identifies INA125P and INA125PA as related candidates, but it does not establish full pin-to-pin equivalence. Validate the manufacturer ordering table and critical electrical parameters before approving a replacement.
When should I choose INA125PAG4 over another instrumentation amplifier?
Choose the INA125PAG4 when the design needs a bridge-ready front end with an integrated precision reference and a 16-pin DIP footprint. It is a sensible option for prototypes and industrial measurement equipment where 500 microvolt input offset and 150 kHz bandwidth are sufficient. Choose another device when wider bandwidth, lower offset, smaller packaging, lower supply voltage, or different reference requirements are essential.
Is INA125PAG4 suitable for pressure transducer measurement?
Yes, the INA125PAG4 is suitable for many pressure-transducer and resistive-bridge measurement circuits because it provides differential amplification and an integrated excitation reference. Its 500 microvolt input offset and 150 kHz bandwidth support moderate-accuracy, moderate-bandwidth measurements. The final error budget should also include bridge resistance, reference tolerance, resistor matching, ADC resolution, and sensor temperature effects.
How should I configure gain on the INA125PAG4?
The INA125 uses its external gain-setting resistors to determine the differential gain while maintaining the internal matched resistor network. The exact resistor values and supported gain steps are defined in the manufacturer datasheet rather than the available excerpts. Follow the gain-table procedure, include the recommended feedback and compensation network, and verify accuracy across temperature and the required input-frequency range.
How much bandwidth does INA125PAG4 have?
The available component data lists the INA125PAG4 bandwidth as 150 kHz. Actual usable signal bandwidth also depends on the selected gain, external gain resistor, output loading, and input capacitance. Check the manufacturer gain-versus-frequency information and the complete electrical characteristics table when designing a high-gain or precision measurement channel.
What is the input offset voltage of INA125PAG4?
The listed input offset voltage for the INA125PAG4 is 500 microvolts. Input offset contributes directly to the output error after the selected differential gain is applied, so its significance grows in high-gain measurements. For precision bridge systems, include offset, drift, bias-current effects, reference accuracy, resistor tolerance, and calibration error in the end-to-end uncertainty budget.
Where can I buy INA125PAG4 and what is the lead time?
Use the Request a Quote form on this page to request current INA125PAG4 availability, commercial terms, and lead time for the exact 16-pin DIP ordering. The manufacturer identifies the part as an industrial-grade INA125-family device, but current inventory and production timing can change. Do not substitute a different package or suffix without confirming the complete ordering information.

Dữ liệu tham khảo kỹ thuật cho INA125PAG4 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose the INA125PAG4 for a resistive-bridge measurement system that needs differential amplification, an integrated excitation reference, and a 16-pin through-hole DIP footprint. Its 500 microvolt input offset and 150 kHz bandwidth are appropriate for many static and moderate-bandwidth industrial measurements. Choose INA125P when its exact ordering characteristics better match the required grade or lead configuration, and choose INA125PA only after confirming that its suffix-specific electrical and packaging requirements are acceptable. A different instrumentation amplifier may be preferable when the application requires lower offset, wider bandwidth, a smaller package, lower supply voltage, rail-to-rail output, or a different reference architecture. For all three INA125-family choices, confirm the complete ordering table, pin configuration, supply limits, common-mode range, output swing, gain network, and reference requirements before approving a substitution.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này INA125P INA125PA
Device Type Instrumentation amplifier with precision voltage reference INA125-family instrumentation amplifier INA125-family instrumentation amplifier
Number of Circuits 1 circuit 1 circuit 1 circuit
Integrated Voltage Reference Yes Yes Yes
Package 16-PDIP 16-PDIP 16-PDIP
Brand Texas Instruments Texas Instruments Texas Instruments
Mounting Type Through-hole Through-hole Through-hole
Input Configuration Differential input Differential input Differential input

Bảo phân biệt quan trọng

  • Integrated precision reference in the same instrumentation-amplifier package (vsINA125P)
  • Differential signal conditioning with 500 microvolt input offset (vsINA125PA)
  • Through-hole industrial DIP implementation (vsINA125P)

Ghi chú thiết kế

Route the differential sensor inputs as a close, matched pair and connect the amplifier ground to the quiet analog-ground system. Keep the INA125PAG4 close to the bridge or sensor connector so that cable pickup is minimized before amplification. Place the input filtering and gain-setting components near the relevant pins, and avoid routing sensitive input traces beneath switching-regulator or digital-clock areas.

Do not select the gain solely from the nominal bridge output range. The maximum input differential voltage, common-mode range, output swing, supply voltage, reference load capability, and bandwidth all change with gain and operating conditions. Verify these limits in the INA125 datasheet, and include offset, gain error, drift, reference accuracy, and resistor tolerance in the measurement uncertainty budget.

For long sensor cables, use suitable input filtering and guarding rather than relying on the amplifier alone to reject noise. Maintain symmetric input paths, provide a stable analog reference return, and keep the reference node free from unwanted loading. When the signal bandwidth is close to the listed 150 kHz value, check gain-dependent bandwidth and output-swing behavior before selecting the final filter bandwidth.

The 16-pin DIP package is straightforward to assemble but does not minimize board area. Preserve the manufacturer's recommended decoupling connections and place them directly between the supply and ground pins. Keep the analog signal path away from the package's unused or adjacent digital-capable pins, and follow the datasheet pin configuration when assigning every net to avoid reversed power or reference connections.

Thông tin tuân thủ

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Không chì
Unknown
Không halogen
Unknown
Khoáng vật xung đột
Unknown

The available product excerpts identify the INA125 as a Texas Instruments industrial instrumentation amplifier but do not provide explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statements.

Dữ liệu được xác minh vào: 2026-11-14 — dữ liệu được xác minh và quản lý bởi đội ngũ kỹ thuật phần cứng của XAIPART

Tìm kiếm liên quan

INA125PAG4 datasheet INA125PAG4 pinout INA125PAG4 datasheet pdf INA125PAG4 equivalent INA125PAG4 replacement INA125PAG4 vs INA125P INA125PAG4 vs INA125PA INA125PAG4 16-PDIP INA125PAG4 load cell amplifier INA125PAG4 pressure transducer INA125PAG4 price INA125PAG4 stock Texas Instruments INA125PAG4 INA125PAG4 500 microvolt offset INA125PAG4 150 kHz bandwidth

Các bộ phận và thuật ngữ liên quan

Texas Instruments INA125PAG4 INA125P INA125PA Instrumentation Amplifier Precision Voltage Reference Differential Amplifier Bridge Excitation Signal Conditioning Load Cell Strain Gauge Pressure Transducer Industrial Process Monitoring Data Acquisition 500 microvolt input offset 150 kHz bandwidth 16-PDIP Through-Hole Package Single-Ended Output Common-Mode Voltage Gain-Setting Resistors Analog-to-Digital Converter
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ