Texas Instruments

INA2126PG4 - Dual 200 kHz Micropower INA | Texas Instruments

MPN: INA2126PG4 ✓ সক্রিয়
1.35 V to 36 V Vdss 175 µA per channel Id 16-pin PDIP, 0.300 inch width, 7.62 mm Package
সর্বনিম্ন অর্ডার পরিমাণ: 1 |

INA2126PG4 সারাংশ

The Texas Instruments INA2126PG4 is a dual-channel, micropower precision instrumentation amplifier designed for accurate differential signal acquisition. It operates from ±1.35 V to ±18 V, or 1.35 V to 36 V across the supply range, and provides a bandwidth of 200 kHz. The device combines a two-op-amp instrumentation-amplifier architecture with very low quiescent current of 175 µA per channel, making it suitable for portable measurement systems, industrial sensor interfaces, battery-powered equipment, and low-power data-acquisition designs. The INA2126PG4 is packaged in a 16-pin PDIP package.

An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the difference between two input voltages while rejecting common-mode interference. The INA2126 belongs to the instrumentation-amplifier hierarchy of analog ICs and is designed to provide high input impedance, low offset voltage, and accurate differential gain. Its two-op-amp design provides a practical balance between low power consumption and signal fidelity, making it useful when common-mode noise, source impedance, or limited supply energy restricts simpler amplifier arrangements.

The INA2126PG4 is specified with 175 µA per-channel quiescent current, up to 250 µV maximum offset voltage, 83 dB CMRR, and 200 kHz bandwidth according to the Texas Instruments product information. The device also supports a supply voltage from 1.35 V to 36 V, allowing operation from low-voltage portable systems through higher-voltage industrial rails. Its dual-channel configuration permits simultaneous acquisition of two differential signals, reducing the number of separate instrumentation amplifiers required on a measurement board.

The two-op-amp architecture is intended for accurate, low-noise differential-signal acquisition. Input bias current is listed as 10 nA in product information, helping preserve accuracy when connected to high-impedance sensors. The 0.4 V/µs slew rate supports amplification of changing sensor signals, while the 200 kHz bandwidth covers many pressure, temperature, strain, and low-frequency industrial measurement applications. The instrumentation-amplifier function converts a small differential input into a larger single-ended signal for an ADC or downstream measurement circuit.

Typical uses include portable medical and laboratory instruments, low-power industrial controllers, battery-operated sensor interfaces, bridge and thermocouple signal conditioning, and general-purpose data-acquisition systems. The dual architecture is especially useful when two channels must be acquired at similar signal levels, such as paired strain-gauge or pressure-sensor channels. Design engineers should select external gain and filtering components to match the sensor output, required bandwidth, and input common-mode range.

For layout, keep input and feedback components close to the corresponding pins and maintain a symmetric differential signal path. Place decoupling capacitors near the supply pins and route high-impedance input traces away from switching nodes and digital return currents. Verify the actual gain equation, common-mode range, output swing, and supply limits against the manufacturer datasheet before production release. This page combines Texas Instruments product specifications, package information, sourcing guidance, and practical design notes for engineers evaluating the INA2126PG4.

এর জন্য ড্রপ-ইন বিকল্প INA2126PG4 — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

এই পণ্যের জন্য কোনো ড্রপ-ইন বিকল্প পাওয়া যায়নি।

বিকল্প অনুরোধ করুন

INA2126PG4 সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য

Product Type Dual precision instrumentation amplifier
Number of Channels 2 channels
Supply Voltage Range 1.35 V to 36 V
Bipolar Supply Range ±1.35 V to ±18 V
কুইসেন্ট কারেন্ট 175 µA per channel
Maximum Offset Voltage 250 µV
Minimum Input Offset Voltage 50 µV
Bandwidth 200 kHz
CMRR 83 dB
Input Bias Current 10 nA
Slew Rate 0.4 V/µs
Amplifier Architecture Two-op-amp instrumentation amplifier
প্যাকেজ 16-pin PDIP, 0.300 inch width, 7.62 mm
মাউন্টিং টাইপ Through-hole
Application Low-noise differential signal acquisition

INA2126PG4 16-pin pdip, 0.300 inch width, 7.62 mm পিন কনফিগারেশন গাইড

INA2126PG4 (16-pin pdip, 0.300 inch width, 7.62 mm প্যাকেজ)-এর পিন কনফিগারেশন। এই অ্যানালগ কম্পোনেন্টে ইনপুট, আউটপুট ও পাওয়ার সাপ্লাই পিন রয়েছে। অফসেট নাল, কম্পেনসেশন ও এনেবল পিন কনফিগারেশনের জন্য প্রস্তুতকারকের ডেটাশিট দেখুন। সিগন্যাল কন্ডিশনিং ও অ্যামপ্লিফায়ার সার্কিটের জন্য আদর্শ।

INA2126PG4-এর জন্য 16-pin pdip, 0.300 inch width, 7.62 mm প্যাকেজ পিনআউট ডায়াগ্রাম

এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি INA2126PG4.

দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।

সাধারণ ব্যবহার

INA2126PG4 এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Portable sensor measurement, Industrial bridge sensor interface, Battery-powered data acquisition, Medical and laboratory instrumentation, Thermocouple and low-level sensor conditioning, Process-control signal input.

📱

Portable sensor measurement

The INA2126PG4 fits portable sensor measurement because its 175 µA per-channel quiescent current limits the power required by the analog front end. The dual architecture supports two low-level differential channels, while the 10 nA input bias current helps maintain accuracy with high-impedance sources. The 200 kHz bandwidth covers many pressure, temperature, and strain signals without requiring a high-speed, high-power instrumentation amplifier.

🏭

Industrial bridge sensor interface

The INA2126PG4 is appropriate for industrial bridge and strain-gauge interfaces where the useful signal is differential and common-mode interference must be rejected. Its 83 dB CMRR and 250 µV maximum offset voltage support accurate measurement of small bridge outputs. The 16-pin PDIP package also remains practical for through-hole industrial instrumentation and prototype boards where a dual analog channel is required.

🔋

Battery-powered data acquisition

For battery-powered data acquisition, the INA2126PG4 combines a 1.35 V minimum supply capability with 175 µA per-channel quiescent current. These characteristics help reduce power consumed when the system is monitoring differential sensors over long intervals. The dual-channel configuration lets one IC acquire two related signals, reducing board area while preserving the precision required for low-level measurements.

💊

Medical and laboratory instrumentation

The INA2126PG4 can serve in medical and laboratory instruments when the design needs low offset, high input impedance, and common-mode rejection for small differential signals. The 50 µV minimum offset voltage and 10 nA input bias current help preserve measurement integrity with sensitive probes. Its 200 kHz bandwidth is suitable for many physiological and laboratory signals that do not require high-frequency acquisition.

🌡️

Thermocouple and low-level sensor conditioning

The INA2126PG4 is useful for thermocouple and other low-level sensor conditioning because it amplifies a differential input rather than a signal referenced directly to ground. The 250 µV maximum offset specification and 83 dB CMRR help reduce errors in millivolt-level measurements. The dual architecture allows related sensor channels to be conditioned together, provided each channel's common-mode and output limits are checked independently.

🏭

Process-control signal input

The INA2126PG4 is appropriate for process-control equipment that receives differential signals from pressure, level, or flow transmitters. Its low 175 µA per-channel quiescent current reduces auxiliary power consumption, while the 0.4 V/µs slew rate and 200 kHz bandwidth accommodate changing process signals. Designers should place input filtering close to the device and verify that transmitter common-mode voltage remains within the specified range.

সুপারিশকৃত পণ্যের সারসংক্ষেপ

INA2126 Same INA2126 instrumentation-amplifier family ব্যবহৃত হয়: Portable sensor measurement, Industrial bridge sensor interface, Battery-powered data acquisition, Medical and laboratory instrumentation, Thermocouple and low-level sensor conditioning, Process-control signal input TS974IDT STMicroelectronics ব্যবহৃত হয়: Portable sensor measurement, Battery-powered data acquisition, Thermocouple and low-level sensor conditioning AK5383VS TI ব্যবহৃত হয়: Industrial bridge sensor interface, Process-control signal input AK4495EQ AKM (Asahi Kasei Microdevices) ব্যবহৃত হয়: Medical and laboratory instrumentation
What is the INA2126PG4 used for?
The INA2126PG4 is a dual precision instrumentation amplifier for low-noise differential signal acquisition. According to the Texas Instruments product page, the INA2126 family provides 175 µA per channel, 250 µV maximum offset voltage, and 200 kHz bandwidth. It is used to amplify small sensor signals while rejecting common-mode interference in industrial, portable, and data-acquisition systems.
What is the operating voltage range of INA2126PG4?
The INA2126PG4 operates from 1.35 V to 36 V, equivalent to a stated bipolar range of ±1.35 V to ±18 V. According to the Texas Instruments product information, this wide supply range supports low-voltage portable instruments and higher-voltage industrial measurement circuits, subject to the limits of the selected supply configuration.
How much current does the INA2126PG4 consume?
The INA2126PG4 has a quiescent current of 175 µA per channel according to the Texas Instruments product page. This micropower level is a key advantage for battery-powered instrumentation and portable sensor systems because it reduces the standby power required by the analog front end when the measurement is not dominated by external load current.
Is INA2126PG4 a dual instrumentation amplifier?
Yes. The INA2126PG4 is a two-channel instrumentation amplifier, with two amplifier functions in a 16-pin PDIP package. Texas Instruments describes the INA2126 as a dual micropower precision instrumentation amplifier intended for accurate, low-noise differential-signal acquisition.
What is the bandwidth of the INA2126PG4?
The INA2126PG4 has a 200 kHz bandwidth. This bandwidth is suitable for many low-frequency sensor and industrial measurement signals, including pressure, temperature, strain, and bridge-transducer outputs. The Texas Instruments product information also lists a 0.4 V/µs slew rate for the device.
What is the CMRR of the INA2126PG4?
The INA2126PG4 is specified with 83 dB CMRR according to the Texas Instruments product information. CMRR, or common-mode rejection ratio, describes the device's ability to reject voltage common to both differential inputs, which is important when the sensor signal is small and the surrounding system contains switching or ground-related interference.
Where can I download the INA2126PG4 datasheet PDF?
The manufacturer datasheet is available through the Texas Instruments INA2126 product page and the linked INA2126 datasheet PDF at https://www.ti.com/lit/gpn/INA2126. The PDF contains the authoritative ordering information, pin description, electrical characteristics, gain equation, common-mode-range information, and application guidance for the INA2126 family.
Where can I find the INA2126PG4 pinout?
The INA2126PG4 pinout is identified in the Texas Instruments INA2126 datasheet, whose family datasheet is available at https://www.ti.com/lit/gpn/INA2126. Use the pin-description table in that datasheet when assigning the 16 PDIP connections and PCB tracks, especially for supply, ground, reference, input, feedback, and output connections.
Can INA2126PG4 replace an INA126P?
The INA2126PG4 should not be treated as a direct replacement for an INA126P without verifying the pinout and gain implementation. The INA126P is a single-channel, 8-pin PDIP device, whereas the INA2126PG4 is a dual-channel, 16-pin PDIP device. The shared instrumentation-amplifier function does not make the packages pin-to-pin compatible.
What is the difference between INA2126PG4 and INA2126U?
The INA2126PG4 and INA2126U are both associated with the dual INA2126 family, but their package suffixes indicate different package configurations. The INA2126PG4 is a 16-pin PDIP part, while the INA2126U is listed as an 8-SOIC option in the comparison information. They are not drop-in replacements for one another because their package pin counts and physical footprints differ.
Is INA2126PG4 suitable for low-voltage sensor interfaces?
The INA2126PG4 is suitable for low-voltage sensor interfaces when the input common-mode and output swing remain inside the device's operating limits. Its 1.35 V minimum supply, 175 µA per-channel quiescent current, 50 µV minimum offset voltage, and 10 nA input bias current support precision and low-power acquisition.
What is the INA2126PG4 offset voltage?
The INA2126PG4 has a maximum offset voltage of 250 µV, with a minimum input offset voltage of 50 µV reported in the product information. Offset voltage is the small differential voltage that can appear at the output even when the differential input is zero, so it matters directly in precision measurement systems.
How do I choose the gain for the INA2126PG4?
Choose the gain using the INA2126 gain equation and the input common-mode and output voltage limits in the Texas Instruments datasheet. The device uses external resistors for its instrumentation-amplifier gain, so resistor tolerance, thermal noise, and parasitic resistance affect accuracy. Confirm that the sensor voltage, output range, and selected gain remain within the specified operating envelope.
Where can I buy INA2126PG4 and what is its current price?
Use the Request a Quote form on this page to request current INA2126PG4 availability, unit pricing, and lead time from XAIPART. The Texas Instruments product page identifies the device as the dual 36 V micropower INA2126, while distributor listings identify the INA2126PG4 as a 16-PDIP instrumentation amplifier.
What is the lead time for INA2126PG4?
Current INA2126PG4 lead time and stock status should be requested through the Request a Quote form on this page. One distributor listing states that its lead time is to be confirmed, so the order-specific schedule should be confirmed before committing a production schedule. The manufacturer product page is the appropriate starting point for lifecycle and quality information.
What should I check before placing the INA2126PG4 in a PCB design?
Check the 16-pin PDIP pinout, supply limits, common-mode input range, output swing, gain resistor values, and stability recommendations in the Texas Instruments datasheet. Keep input and feedback paths short, place decoupling capacitors near the supply pins, and isolate high-impedance input traces from switching and digital return paths.
Does the INA2126PG4 need a heatsink?
The INA2126PG4 is a micropower instrumentation amplifier with 175 µA per-channel quiescent current, so it generally does not require a large heatsink in typical signal-conditioning applications. Actual thermal requirements depend on supply voltage, load, output swing, ambient temperature, and PCB copper. Texas Instruments specifies the device's operating characteristics and thermal limits in the INA2126 datasheet.
Is INA2126PG4 RoHS compliant?
The RoHS status of the INA2126PG4 is not stated in the available manufacturer product information, so compliance should be confirmed with Texas Instruments or the current product documentation before release. The same caution applies to REACH and lead-free status. Use the Request a Quote form on this page to request current compliance and traceability documentation for the exact orderable MPN.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা INA2126PG4 — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose the INA2126PG4 when the design needs a dual, micropower instrumentation amplifier for low-level differential signals. Its 175 µA per-channel quiescent current is appropriate for portable and battery-powered equipment, while 250 µV maximum offset voltage, 83 dB CMRR, and 10 nA input bias current support precision acquisition. The 200 kHz bandwidth is suitable for many pressure, temperature, strain, bridge, and laboratory signals. Use an alternative only after confirming that the replacement has the same 16-pin PDIP footprint, two channels, compatible pinout, suitable common-mode range, and equivalent gain network. A single-channel 8-pin instrument amplifier may be adequate when one signal is required, but it is not a drop-in substitute for this dual-channel part.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য
Product Type Dual precision instrumentation amplifier
Number of Channels 2
Supply Voltage Range 1.35 V to 36 V
Quiescent Current 175 µA per channel
Offset Voltage 250 µV maximum
Bandwidth 200 kHz
CMRR 83 dB
Package 16-pin PDIP
Brand Texas Instruments
Input Bias Current 10 nA
Slew Rate 0.4 V/µs
Architecture Two-op-amp instrumentation amplifier

মূল পার্থক্যসমূহ

  • Dual-channel micropower instrumentation amplification (বনামINA126P)
  • Wide single-supply operating range (বনামINA126P)
  • Precision differential acquisition (বনামINA126P)

ডিজাইন নোট

Place the external gain-setting resistors and input filtering components close to the INA2126PG4 pins. Keep the two input traces short, matched in length where practical, and routed away from switching-node and high-current return paths. High source impedance makes the 10 nA input bias current and board leakage important contributors to input error.

Add supply decoupling close to the power pins and confirm the selected supply voltage against the 1.35 V to 36 V operating range. Because the INA2126PG4 is intended for low-power operation, verify that the external resistor values and output load do not dominate the total system current. Use the datasheet's recommended bypass and output-feedback network when designing the final circuit.

Do not assume that any instrumentation amplifier with a similar bandwidth is a drop-in replacement. INA2126PG4 is a dual 16-pin PDIP device, so a candidate must have the same package, pin assignments, channel count, gain architecture, supply limits, and common-mode behavior. Verify the gain equation and input/output common-mode limits before changing the amplifier in an existing PCB design.

কমপ্লায়েন্স তথ্য

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
লিড ফ্রি
Unknown
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

The available manufacturer product information identifies the INA2126 family and its electrical characteristics but does not state the individual RoHS, REACH, lead-free, halogen-free, or conflict-minerals status of INA2126PG4. Current compliance documentation should be requested for the exact orderable part.

ডেটা যাচাই করা হয়েছে: 2026-11-14 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

INA2126PG4 datasheet INA2126PG4 pinout INA2126PG4 datasheet pdf INA2126PG4 specifications INA2126PG4 equivalent INA2126PG4 replacement INA2126PG4 cross reference INA2126PG4 price INA2126PG4 stock INA2126PG4 16 pin PDIP INA2126PG4 200 kHz instrumentation amplifier INA2126PG4 vs INA126P INA2126PG4 application circuit Texas Instruments INA2126PG4 INA2126PG4 low power sensor amplifier

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

Texas Instruments INA2126PG4 INA2126 INA126P precision instrumentation amplifier dual instrumentation amplifier analog signal-conditioning IC differential signal acquisition common-mode rejection ratio CMRR input offset voltage input bias current quiescent current gain bandwidth two-op-amp architecture 16-pin PDIP surface-mount and through-hole integrated circuits portable instrumentation industrial sensor interface battery-powered data acquisition process-control signal conditioning Texas Instruments product page INA2126 datasheet
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন