INA2126PG4 - Dual 200 kHz Micropower INA | Texas Instruments
Артикул: INA2126PG4 ✓ АктивенINA2126PG4 Обзор
An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the difference between two input voltages while rejecting common-mode interference. The INA2126 belongs to the instrumentation-amplifier hierarchy of analog ICs and is designed to provide high input impedance, low offset voltage, and accurate differential gain. Its two-op-amp design provides a practical balance between low power consumption and signal fidelity, making it useful when common-mode noise, source impedance, or limited supply energy restricts simpler amplifier arrangements.
The INA2126PG4 is specified with 175 µA per-channel quiescent current, up to 250 µV maximum offset voltage, 83 dB CMRR, and 200 kHz bandwidth according to the Texas Instruments product information. The device also supports a supply voltage from 1.35 V to 36 V, allowing operation from low-voltage portable systems through higher-voltage industrial rails. Its dual-channel configuration permits simultaneous acquisition of two differential signals, reducing the number of separate instrumentation amplifiers required on a measurement board.
The two-op-amp architecture is intended for accurate, low-noise differential-signal acquisition. Input bias current is listed as 10 nA in product information, helping preserve accuracy when connected to high-impedance sensors. The 0.4 V/µs slew rate supports amplification of changing sensor signals, while the 200 kHz bandwidth covers many pressure, temperature, strain, and low-frequency industrial measurement applications. The instrumentation-amplifier function converts a small differential input into a larger single-ended signal for an ADC or downstream measurement circuit.
Typical uses include portable medical and laboratory instruments, low-power industrial controllers, battery-operated sensor interfaces, bridge and thermocouple signal conditioning, and general-purpose data-acquisition systems. The dual architecture is especially useful when two channels must be acquired at similar signal levels, such as paired strain-gauge or pressure-sensor channels. Design engineers should select external gain and filtering components to match the sensor output, required bandwidth, and input common-mode range.
For layout, keep input and feedback components close to the corresponding pins and maintain a symmetric differential signal path. Place decoupling capacitors near the supply pins and route high-impedance input traces away from switching nodes and digital return currents. Verify the actual gain equation, common-mode range, output swing, and supply limits against the manufacturer datasheet before production release. This page combines Texas Instruments product specifications, package information, sourcing guidance, and practical design notes for engineers evaluating the INA2126PG4.
Аналоги без доработки для INA2126PG4 — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Для этого товара нет аналогов без доработки.
Запросить аналогиINA2126PG4 Максимальные параметры и электрические характеристики
| Product Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 channels |
| Supply Voltage Range | 1.35 V to 36 V |
| Bipolar Supply Range | ±1.35 V to ±18 V |
| Ток покоя | 175 µA per channel |
| Maximum Offset Voltage | 250 µV |
| Minimum Input Offset Voltage | 50 µV |
| Bandwidth | 200 kHz |
| CMRR | 83 dB |
| Input Bias Current | 10 nA |
| Slew Rate | 0.4 V/µs |
| Amplifier Architecture | Two-op-amp instrumentation amplifier |
| Корпус | 16-pin PDIP, 0.300 inch width, 7.62 mm |
| Тип монтажа | Through-hole |
| Application | Low-noise differential signal acquisition |
Руководство по цоколевке INA2126PG4 в корпусе 16-pin pdip, 0.300 inch width, 7.62 mm
Цоколевка для INA2126PG4 (корпус 16-pin pdip, 0.300 inch width, 7.62 mm). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.
Нет подробных данных о распиновке для INA2126PG4.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
INA2126PG4 подходит для 6 применениеs: Portable sensor measurement, Industrial bridge sensor interface, Battery-powered data acquisition, Medical and laboratory instrumentation, Thermocouple and low-level sensor conditioning, Process-control signal input.
Portable sensor measurement
The INA2126PG4 fits portable sensor measurement because its 175 µA per-channel quiescent current limits the power required by the analog front end. The dual architecture supports two low-level differential channels, while the 10 nA input bias current helps maintain accuracy with high-impedance sources. The 200 kHz bandwidth covers many pressure, temperature, and strain signals without requiring a high-speed, high-power instrumentation amplifier.
Рекомендуется
Industrial bridge sensor interface
The INA2126PG4 is appropriate for industrial bridge and strain-gauge interfaces where the useful signal is differential and common-mode interference must be rejected. Its 83 dB CMRR and 250 µV maximum offset voltage support accurate measurement of small bridge outputs. The 16-pin PDIP package also remains practical for through-hole industrial instrumentation and prototype boards where a dual analog channel is required.
Рекомендуется
Battery-powered data acquisition
For battery-powered data acquisition, the INA2126PG4 combines a 1.35 V minimum supply capability with 175 µA per-channel quiescent current. These characteristics help reduce power consumed when the system is monitoring differential sensors over long intervals. The dual-channel configuration lets one IC acquire two related signals, reducing board area while preserving the precision required for low-level measurements.
Рекомендуется
Medical and laboratory instrumentation
The INA2126PG4 can serve in medical and laboratory instruments when the design needs low offset, high input impedance, and common-mode rejection for small differential signals. The 50 µV minimum offset voltage and 10 nA input bias current help preserve measurement integrity with sensitive probes. Its 200 kHz bandwidth is suitable for many physiological and laboratory signals that do not require high-frequency acquisition.
Рекомендуется
Thermocouple and low-level sensor conditioning
The INA2126PG4 is useful for thermocouple and other low-level sensor conditioning because it amplifies a differential input rather than a signal referenced directly to ground. The 250 µV maximum offset specification and 83 dB CMRR help reduce errors in millivolt-level measurements. The dual architecture allows related sensor channels to be conditioned together, provided each channel's common-mode and output limits are checked independently.
Рекомендуется
Process-control signal input
The INA2126PG4 is appropriate for process-control equipment that receives differential signals from pressure, level, or flow transmitters. Its low 175 µA per-channel quiescent current reduces auxiliary power consumption, while the 0.4 V/µs slew rate and 200 kHz bandwidth accommodate changing process signals. Designers should place input filtering close to the device and verify that transmitter common-mode voltage remains within the specified range.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для INA2126PG4 — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар |
|---|---|
| Product Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 |
| Supply Voltage Range | 1.35 V to 36 V |
| Quiescent Current | 175 µA per channel |
| Offset Voltage | 250 µV maximum |
| Bandwidth | 200 kHz |
| CMRR | 83 dB |
| Package | 16-pin PDIP |
| Brand | Texas Instruments |
| Input Bias Current | 10 nA |
| Slew Rate | 0.4 V/µs |
| Architecture | Two-op-amp instrumentation amplifier |
Ключевые отличия
- Dual-channel micropower instrumentation amplification (против INA126P)
- Wide single-supply operating range (против INA126P)
- Precision differential acquisition (против INA126P)
Заметки по проектированию
Place the external gain-setting resistors and input filtering components close to the INA2126PG4 pins. Keep the two input traces short, matched in length where practical, and routed away from switching-node and high-current return paths. High source impedance makes the 10 nA input bias current and board leakage important contributors to input error.
Add supply decoupling close to the power pins and confirm the selected supply voltage against the 1.35 V to 36 V operating range. Because the INA2126PG4 is intended for low-power operation, verify that the external resistor values and output load do not dominate the total system current. Use the datasheet's recommended bypass and output-feedback network when designing the final circuit.
Do not assume that any instrumentation amplifier with a similar bandwidth is a drop-in replacement. INA2126PG4 is a dual 16-pin PDIP device, so a candidate must have the same package, pin assignments, channel count, gain architecture, supply limits, and common-mode behavior. Verify the gain equation and input/output common-mode limits before changing the amplifier in an existing PCB design.
Информация о соответствии
The available manufacturer product information identifies the INA2126 family and its electrical characteristics but does not state the individual RoHS, REACH, lead-free, halogen-free, or conflict-minerals status of INA2126PG4. Current compliance documentation should be requested for the exact orderable part.