INA2126PG4 - Dual 200 kHz Micropower INA | Texas Instruments
MPN: INA2126PG4 ✓ 啟用中INA2126PG4 概覽
An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the difference between two input voltages while rejecting common-mode interference. The INA2126 belongs to the instrumentation-amplifier hierarchy of analog ICs and is designed to provide high input impedance, low offset voltage, and accurate differential gain. Its two-op-amp design provides a practical balance between low power consumption and signal fidelity, making it useful when common-mode noise, source impedance, or limited supply energy restricts simpler amplifier arrangements.
The INA2126PG4 is specified with 175 µA per-channel quiescent current, up to 250 µV maximum offset voltage, 83 dB CMRR, and 200 kHz bandwidth according to the Texas Instruments product information. The device also supports a supply voltage from 1.35 V to 36 V, allowing operation from low-voltage portable systems through higher-voltage industrial rails. Its dual-channel configuration permits simultaneous acquisition of two differential signals, reducing the number of separate instrumentation amplifiers required on a measurement board.
The two-op-amp architecture is intended for accurate, low-noise differential-signal acquisition. Input bias current is listed as 10 nA in product information, helping preserve accuracy when connected to high-impedance sensors. The 0.4 V/µs slew rate supports amplification of changing sensor signals, while the 200 kHz bandwidth covers many pressure, temperature, strain, and low-frequency industrial measurement applications. The instrumentation-amplifier function converts a small differential input into a larger single-ended signal for an ADC or downstream measurement circuit.
Typical uses include portable medical and laboratory instruments, low-power industrial controllers, battery-operated sensor interfaces, bridge and thermocouple signal conditioning, and general-purpose data-acquisition systems. The dual architecture is especially useful when two channels must be acquired at similar signal levels, such as paired strain-gauge or pressure-sensor channels. Design engineers should select external gain and filtering components to match the sensor output, required bandwidth, and input common-mode range.
For layout, keep input and feedback components close to the corresponding pins and maintain a symmetric differential signal path. Place decoupling capacitors near the supply pins and route high-impedance input traces away from switching nodes and digital return currents. Verify the actual gain equation, common-mode range, output swing, and supply limits against the manufacturer datasheet before production release. This page combines Texas Instruments product specifications, package information, sourcing guidance, and practical design notes for engineers evaluating the INA2126PG4.
直接替換替代品,適用於 INA2126PG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此產品無可直接替換的替代品。
申請替代品INA2126PG4 最大額定值與電氣特性
| Product Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 channels |
| Supply Voltage Range | 1.35 V to 36 V |
| Bipolar Supply Range | ±1.35 V to ±18 V |
| 靜態電流 | 175 µA per channel |
| Maximum Offset Voltage | 250 µV |
| Minimum Input Offset Voltage | 50 µV |
| Bandwidth | 200 kHz |
| CMRR | 83 dB |
| Input Bias Current | 10 nA |
| Slew Rate | 0.4 V/µs |
| Amplifier Architecture | Two-op-amp instrumentation amplifier |
| 封裝 | 16-pin PDIP, 0.300 inch width, 7.62 mm |
| 安裝類型 | Through-hole |
| Application | Low-noise differential signal acquisition |
INA2126PG4 16-pin pdip, 0.300 inch width, 7.62 mm 腳位配置指南
INA2126PG4(16-pin pdip, 0.300 inch width, 7.62 mm 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA2126PG4.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA2126PG4 適用於 6 應用s: Portable sensor measurement, Industrial bridge sensor interface, Battery-powered data acquisition, Medical and laboratory instrumentation, Thermocouple and low-level sensor conditioning, Process-control signal input.
Portable sensor measurement
The INA2126PG4 fits portable sensor measurement because its 175 µA per-channel quiescent current limits the power required by the analog front end. The dual architecture supports two low-level differential channels, while the 10 nA input bias current helps maintain accuracy with high-impedance sources. The 200 kHz bandwidth covers many pressure, temperature, and strain signals without requiring a high-speed, high-power instrumentation amplifier.
推薦
Industrial bridge sensor interface
The INA2126PG4 is appropriate for industrial bridge and strain-gauge interfaces where the useful signal is differential and common-mode interference must be rejected. Its 83 dB CMRR and 250 µV maximum offset voltage support accurate measurement of small bridge outputs. The 16-pin PDIP package also remains practical for through-hole industrial instrumentation and prototype boards where a dual analog channel is required.
推薦
Battery-powered data acquisition
For battery-powered data acquisition, the INA2126PG4 combines a 1.35 V minimum supply capability with 175 µA per-channel quiescent current. These characteristics help reduce power consumed when the system is monitoring differential sensors over long intervals. The dual-channel configuration lets one IC acquire two related signals, reducing board area while preserving the precision required for low-level measurements.
推薦
Medical and laboratory instrumentation
The INA2126PG4 can serve in medical and laboratory instruments when the design needs low offset, high input impedance, and common-mode rejection for small differential signals. The 50 µV minimum offset voltage and 10 nA input bias current help preserve measurement integrity with sensitive probes. Its 200 kHz bandwidth is suitable for many physiological and laboratory signals that do not require high-frequency acquisition.
推薦
Thermocouple and low-level sensor conditioning
The INA2126PG4 is useful for thermocouple and other low-level sensor conditioning because it amplifies a differential input rather than a signal referenced directly to ground. The 250 µV maximum offset specification and 83 dB CMRR help reduce errors in millivolt-level measurements. The dual architecture allows related sensor channels to be conditioned together, provided each channel's common-mode and output limits are checked independently.
推薦
Process-control signal input
The INA2126PG4 is appropriate for process-control equipment that receives differential signals from pressure, level, or flow transmitters. Its low 175 µA per-channel quiescent current reduces auxiliary power consumption, while the 0.4 V/µs slew rate and 200 kHz bandwidth accommodate changing process signals. Designers should place input filtering close to the device and verify that transmitter common-mode voltage remains within the specified range.
推薦
推薦產品摘要
工程參考資料,適用於 INA2126PG4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Product Type | Dual precision instrumentation amplifier |
| Number of Channels | 2 |
| Supply Voltage Range | 1.35 V to 36 V |
| Quiescent Current | 175 µA per channel |
| Offset Voltage | 250 µV maximum |
| Bandwidth | 200 kHz |
| CMRR | 83 dB |
| Package | 16-pin PDIP |
| Brand | Texas Instruments |
| Input Bias Current | 10 nA |
| Slew Rate | 0.4 V/µs |
| Architecture | Two-op-amp instrumentation amplifier |
主要差異化特點
- Dual-channel micropower instrumentation amplification (對比INA126P)
- Wide single-supply operating range (對比INA126P)
- Precision differential acquisition (對比INA126P)
設計說明
Place the external gain-setting resistors and input filtering components close to the INA2126PG4 pins. Keep the two input traces short, matched in length where practical, and routed away from switching-node and high-current return paths. High source impedance makes the 10 nA input bias current and board leakage important contributors to input error.
Add supply decoupling close to the power pins and confirm the selected supply voltage against the 1.35 V to 36 V operating range. Because the INA2126PG4 is intended for low-power operation, verify that the external resistor values and output load do not dominate the total system current. Use the datasheet's recommended bypass and output-feedback network when designing the final circuit.
Do not assume that any instrumentation amplifier with a similar bandwidth is a drop-in replacement. INA2126PG4 is a dual 16-pin PDIP device, so a candidate must have the same package, pin assignments, channel count, gain architecture, supply limits, and common-mode behavior. Verify the gain equation and input/output common-mode limits before changing the amplifier in an existing PCB design.
合規資訊
The available manufacturer product information identifies the INA2126 family and its electrical characteristics but does not state the individual RoHS, REACH, lead-free, halogen-free, or conflict-minerals status of INA2126PG4. Current compliance documentation should be requested for the exact orderable part.