MAX3232EWE+T - 1Mbps RS-232 Transceiver | Analog Devices
MPN: MAX3232EWE+T ✓ সক্রিয়MAX3232EWE+T সারাংশ
A true RS-232 transceiver converts logic-level signals from a UART, microcontroller, or host into balanced, bipolar serial-port levels, then converts incoming serial signals back into CMOS-compatible logic. Within the interface hierarchy, the MAX3232E is a full-duplex RS-232 transceiver, a line-driver and line-receiver circuit, and a serial interface IC commonly used for legacy serial ports, industrial equipment, and embedded control links.
Key features include a 3.0 V minimum supply voltage, a 5.5 V maximum supply voltage, and an operating data rate of up to 1 Mbps. The MAX3232E adds plus or minus 15 kV ESD protection, while its low-power design supports shutdown and reduced-power operating modes for portable or space-constrained equipment. Four external 0.1 uF capacitors allow the on-chip charge pump to generate the positive and negative voltages required by true RS-232 drivers.
Internally, the device combines two line drivers, two line receivers, and a dual charge-pump circuit. The charge-pump architecture supports operation from a single 3.0 V to 5.5 V supply instead of a plus or minus voltage source. This simplifies board design, although external capacitor placement and connector-side transient protection remain essential for reliable serial links in industrial environments.
Typical applications include RS-232 connections to test and measurement equipment, database controllers, modems, point-of-sale terminals, industrial control panels, and legacy service-port interfaces. The 1 Mbps capability is useful for short, point-to-point links where legacy software expects standard RS-232 signaling, while the 16-SOIC package simplifies assembly on through-hole-compatible boards.
When laying out this transceiver, place the four 0.1 uF charge-pump capacitors close to their designated pins and route connector-side signals away from sensitive logic. Keep the interface ground reference close to the connector ground and confirm that the host UART voltage levels match the MAX3232E logic supply.
This page organizes the MAX3232EWE+T specifications, package details, drop-in alternatives, application guidance, and design notes into a single engineering reference for RS-232 interface design and sourcing decisions.
এর জন্য ড্রপ-ইন বিকল্প MAX3232EWE+T — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই সিরিজের ভ্যারিয়েন্ট
একই সিরিজের মডেল যেগুলো drop-in compatible MAX3232EWE+T (একই form factor এবং footprint) — পার্থক্য রয়েছে Package, Charge-Pump Architecture, Maximum Data Rate, Supply Voltage Range, ESD Protection.
MAX3232EWE+
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
MAX3232CDW
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →MAX3232CWE+
✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়মূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →MAX3232EUE+T
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →MAX3232ESE+T
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →MAX3232EWE+T বিশেষণ
| Product Type | True RS-232 transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Supply Voltage Range | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps |
| ESD Protection | +/-15 kV on serial-port connection pins |
| Low-Power Shutdown Current | Down to 10 nA |
| Charge-Pump Capacitors | 4 x 0.1 uF |
| Charge-Pump Architecture | Dual on-chip charge pump |
| প্যাকেজ | 16-SOIC |
| পিন সংখ্যা | 16 pins |
| মাউন্টিং টাইপ | Surface mount |
| Signal Standard | TIA/EIA-232-F / true RS-232 |
| Production Status | Production |
MAX3232EWE+T 16-soic পিন কনফিগারেশন গাইড
MAX3232EWE+T (16-soic প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।
এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি MAX3232EWE+T.
দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।
সাধারণ ব্যবহার
MAX3232EWE+T এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Industrial Controller RS-232 Port, Test and Measurement Equipment, Database and Legacy Service Interfaces, Point-of-Sale and Retail Terminals, Embedded UART-to-RS-232 Bridges, Portable and Service Diagnostic Equipment.
Industrial Controller RS-232 Port
The MAX3232EWE+T fits industrial controller boards that must communicate with legacy RS-232 equipment through a DB9 connector. Its two-driver, two-receiver arrangement supports full-duplex links, while the 3.0 V to 5.5 V supply range allows operation from a 3.3 V system rail. The documented up-to-1-Mbps capability supports short service links, and plus or minus 15 kV ESD protection strengthens the connector-facing pins. Route the four 0.1 uF charge-pump capacitors exactly as shown in the pin-configuration table.
সুপারিশকৃত
Test and Measurement Equipment
The MAX3232EWE+T provides a practical single-supply RS-232 interface for oscilloscopes, bench instruments, and laboratory controllers that retain serial-port connectors. Two drivers and two receivers support bidirectional command and response traffic, while the true RS-232 charge pump generates the bipolar voltage levels expected by older equipment. The 1 Mbps rate provides margin for short direct connections, and the low-power shutdown mode helps reduce standby consumption in portable test setups.
সুপারিশকৃত
Database and Legacy Service Interfaces
The MAX3232EWE+T is suited to controllers, adapters, and service equipment that connect to legacy DB9 RS-232 ports. Because the transceiver operates from a single 3.0 V to 5.5 V supply, it avoids the negative rail and discrete charge-pump circuitry once associated with older RS-232 designs. The plus or minus 15 kV ESD rating on serial-port pins provides useful connector-side protection. For cables leaving an enclosure, still add coordinated surge protection and a low-impedance chassis-ground path.
সুপারিশকৃত
Point-of-Sale and Retail Terminals
Point-of-sale terminals, receipt printers, scanners, and payment peripherals can use the MAX3232EWE+T where their host interface requires true RS-232 rather than USB or a differential bus. The 2/2 driver-receiver configuration supports bidirectional service traffic on one connector, and the 16-SOIC package is practical for medium-density control boards. The 1 Mbps maximum rate covers short service connections, while the low-power shutdown current down to 10 nA helps when the terminal spends substantial time idle.
সুপারিশকৃত
Embedded UART-to-RS-232 Bridges
The MAX3232EWE+T bridges a microcontroller UART to a true RS-232 port without requiring a separate negative power rail. Its 3.0 V minimum supply voltage suits 3.3 V embedded systems, and the dual charge pump plus four external 0.1 uF capacitors keeps the interface compact. The 1 Mbps capability covers short diagnostic and configuration links. Confirm UART logic thresholds, connect the transceiver ground reference to the equipment ground, and keep charge-pump routing away from sensitive analog sections.
সুপারিশকৃত
Portable and Service Diagnostic Equipment
Handheld service tools and portable diagnostic devices benefit from the MAX3232EWE+T because it provides true RS-232 signaling from a 3.0 V to 5.5 V supply without a negative rail. The low-power design and shutdown current down to 10 nA reduce the burden on battery-powered systems when the serial interface is inactive. The up-to-1-Mbps rate allows short local connections to equipment consoles, while plus or minus 15 kV ESD protection helps manage electrostatic discharge encountered during field servicing.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা MAX3232EWE+T — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | MAX3232EWE+ | MAX3232CDW | MAX3232CWE+ | MAX3232EUE+T | MAX3232ESE+T |
|---|---|---|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Transceiver Configuration | 2/2 full RS-232 | 2/2 full RS-232 | 2/2 full RS-232 | 2/2 full RS-232 | 2/2 full RS-232 | 2/2 full RS-232 |
| Supply Voltage Range | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps |
| Number of Drivers and Receivers | 2 drivers, 2 receivers | 2 drivers, 2 receivers | 2 drivers, 2 receivers | 2 drivers, 2 receivers | 2 drivers, 2 receivers | 2 drivers, 2 receivers |
মূল পার্থক্যসমূহ
- Documented high-level ESD protection on serial-port pins (বনামMAX3232CDW)
- Very low shutdown current for power-managed interfaces (বনামMAX3232CDW)
- Full-duplex interface in a widely used 16-SOIC format (বনামMAX3221IPWR)
- Single-supply true RS-232 operation with a 1 Mbps ceiling (বনামMAX3232ESE+T)
ডিজাইন নোট
Place the four required 0.1 uF charge-pump capacitors directly beside their corresponding MAX3232EWE+T pins and keep the associated traces short. Use the manufacturer pin-configuration table to confirm capacitor orientation and connection. Keep switching charge-pump nodes away from receiver inputs and sensitive analog circuitry to minimize radiated and coupled noise on the serial interface.
Do not treat the MAX3232EWE+T as a 5 V TTL transceiver; it generates true bipolar RS-232 levels through its charge pump. Verify that the host UART uses compatible logic levels, connect the interface ground to the equipment ground, and install the four 0.1 uF capacitors. A missing or incorrectly valued charge-pump capacitor can prevent negative-voltage generation and cause communication failures.
For connector-side cables, route TXD and RXD traces away from clocks, switching regulators, and sensitive analog inputs. Maintain a continuous interface-ground reference between the transceiver and connector ground. The plus or minus 15 kV ESD rating is a component-level protection feature, but board layout, chassis grounding, and coordinated external surge protection remain necessary for cables exposed to industrial transients.
Decouple the MAX3232EWE+T supply at the device with local high-frequency and bulk capacitance, following the manufacturer layout guidance. The 3.0 V to 5.5 V operating range permits a 3.3 V system rail, but confirm UART logic thresholds before connecting. When shutdown current down to 10 nA is important, drive the shutdown control correctly and account for leakage from the external capacitor network.
কমপ্লায়েন্স তথ্য
The Analog Devices product page identifies the MAX3232E family as being in production. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals statements were not confirmed in the retrieved product information.