AD582SH - 25us Sample-and-Hold Amplifier | Analog Devices
MPN: AD582SH ✗ کۆتایی ژیانAD582SH گشتی
A sample-and-hold amplifier is a data-conversion support circuit that samples an analog input during a defined acquisition interval and stores that voltage on an external capacitor while the remaining circuit performs conversion, comparison, measurement, or signal processing. In the broader hierarchy, it belongs to the amplifier family, specifically instrumentation and signal-conditioning ICs used with ADCs, sensors, test systems, and precision control equipment.
The AD582SH supports input signals up to ±12 V according to the manufacturer documentation and uses separate analog and digital ground connections to improve rejection of ground and switching transients. Its low-leakage hold path is central to preserving the captured voltage during conversion intervals, while the integrated amplifier reduces the number of external active components required. The 25 µs acquisition specification makes the device suitable for moderate-speed data-acquisition channels rather than high-frequency waveform capture.
A typical implementation places the input signal on the amplifier input, connects the prescribed external holding capacitor to the hold terminal, and applies the logic control signal required to switch between acquisition and hold states. Designers should maintain separate analog and ground-return paths, place the holding capacitor close to the device, and account for capacitor leakage, dielectric absorption, input bias current, and settling time when defining system accuracy.
Typical uses include multiplexed data-acquisition systems, analog measurement front ends, industrial process monitoring, laboratory instrumentation, and sampled sensor interfaces. The AD582SH can also precede successive-approximation or pipeline ADCs when a stable input must be presented during conversion. Its integrated architecture is particularly useful where board area, component count, and predictable acquisition behavior matter more than very short acquisition times.
The principal design trade-off is acquisition speed versus hold error. Selecting the external holding capacitor requires balancing settled output voltage, capacitor leakage, dielectric absorption, and the time available to charge it. Keep high-impedance routes short, provide clean grounding, and verify timing against the acquisition interval required by the downstream converter rather than treating the 25 µs figure as independent of capacitor and source impedance.
This page combines the manufacturer's device description with package information, drop-in replacement guidance, application-oriented circuit considerations, and a parameter comparison. It supports faster engineering selection by separating the verified AD582SH characteristics from design assumptions that must be checked against the external holding capacitor and the complete acquisition system.
جێگرەوەکانی جێگۆڕکێ بۆ AD582SH — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ AD582SH (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Acquisition Time, Product Type.
AD582SH/883B
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD582KD
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD582JH
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD582JH/883B
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD582/883B
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD582SH زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | Integrated sample-and-hold amplifier |
| Channel Count | 1 channel |
| Acquisition Time | 25 µs |
| Output Current | 25 mA |
| ڤۆڵتیەی دابینکردن | 15 V |
| Input Signal Range | Up to ±12 V |
| Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip |
| Hold Element | External holding capacitor |
| Ground Configuration | Separate analog and digital grounds |
| پاکێج | 10-pin TO-100 |
| جۆری دامەزراندن | Through-hole |
| Military Version | Available in versions compliant with MIL-STD-883 |
ڕێنمایی ڕێکخستنی پینی AD582SH 10-pin to-100
ڕێکخستنی پین بۆ AD582SH (پاکێجی 10-pin to-100). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ AD582SH.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
AD582SH گونجاوە بۆ 6 بەکارھێنانs: Multiplexed Analog Data Acquisition, Precision Sensor Signal Conditioning, Laboratory Instrumentation Front End, Process Control Signal Capture, Automated Test Equipment, Legacy Measurement System Upgrade.
Multiplexed Analog Data Acquisition
The AD582SH is suitable for a multiplexed measurement channel that must present a stable analog voltage to an ADC during conversion. Its 25 µs acquisition time defines the interval in which the input is sampled, while the integrated low-leakage switch and JFET amplifier support the subsequent hold state. Place the external holding capacitor close to the device and allow acquisition time for the source impedance, capacitor value, and settling behavior. This arrangement reduces the number of discrete active components required around the converter and is useful in industrial measurement systems where repeatable acquisition timing is more important than ultra-high-speed waveform acquisition.
پێشنیارکراو
Precision Sensor Signal Conditioning
The AD582SH can stabilize sensor outputs before downstream measurement or conversion. Its input stage supports signals up to ±12 V, and the low-leakage hold path helps preserve the captured voltage while the system processes the sample. The 25 µs acquisition specification is appropriate for temperature, pressure, position, and slowly changing industrial sensor signals rather than fast transient capture. Care is required with high-impedance sources because bias current, leakage, dielectric absorption, and connector contamination can influence the held value. A short input route and low-leakage external capacitor are particularly important in high-impedance sensor interfaces.
پێشنیارکراو
Laboratory Instrumentation Front End
The AD582SH can serve as the acquisition element in a laboratory instrument that alternates between measuring an input and holding it during display, computation, or reference comparison. Its integrated operational-amplifier, analog-switch, and JFET structure simplifies the analog section while retaining a 25 µs acquisition specification. The separate analog and digital ground connections help reduce susceptibility to ground and switching transients in mixed-signal equipment. For accurate results, route the held signal toward the measuring channel, keep the holding capacitor physically close, and verify droop over the complete conversion and processing interval rather than only the nominal acquisition time.
پێشنیارکراو
Process Control Signal Capture
The AD582SH can capture an analog process variable and hold it during control-loop calculation or actuator update. The 25 µs acquisition time is well suited to common pressure, flow, level, and temperature monitoring signals, while the low-leakage hold characteristic supports stable conversion of slow-moving quantities. Place the device behind appropriate input conditioning and protection because the measured signal must remain within the documented input limits. Separate analog and ground-return routing reduces switching disturbance. Validate the timing against the controller's update cycle, and include capacitor leakage and dielectric absorption in the total measurement-error budget.
پێشنیارکراو
Automated Test Equipment
The AD582SH can hold a test-node voltage while automated equipment performs comparison, measurement, or digital processing. A 25 µs acquisition interval allows each measurement point to settle after selection, while the integrated hold circuit reduces the component count of legacy analog measurement fixtures. The 10-pin TO-100 package remains useful for repair and modernization of existing instrument boards. Designers should coordinate the hold command with the test-system timing controller and verify that the external capacitor has adequate leakage margin for the measurement duration. Any replacement must preserve the exact 10-pin connection and acquisition behavior.
پێشنیارکراو
Legacy Measurement System Upgrade
The AD582SH is well suited to maintaining or reproducing legacy analog-measurement equipment that already uses the 10-pin TO-100 AD582 footprint. Its 1-channel, 25 µs sample-and-hold function supports existing acquisition sequencing without requiring a different board pattern. During repair or redesign, confirm the exact ordering suffix, supply voltage, temperature grade, and external capacitor configuration before fitting the part. AD582SH/883B is a practical option when military processing is required, while other family suffixes should be selected according to environmental and qualification requirements rather than package appearance alone.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ AD582SH — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | AD582SH/883B | AD582KD | AD582JH | AD582JH/883B | AD582/883B |
|---|---|---|---|---|---|---|
| Product Type | 1-channel integrated sample-and-hold amplifier | 1-channel integrated sample-and-hold amplifier | 1-channel integrated sample-and-hold amplifier | 1-channel integrated sample-and-hold amplifier | 1-channel integrated sample-and-hold amplifier | 1-channel integrated sample-and-hold amplifier |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 10-pin TO-100 | 10-pin TO-100 | 10-pin TO-100 | 10-pin TO-100 | 10-pin TO-100 | 10-pin TO-100 |
| Channel Count | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel |
| Internal Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier | Monolithic sample-and-hold amplifier | Monolithic sample-and-hold amplifier | Monolithic sample-and-hold amplifier | Monolithic sample-and-hold amplifier | Monolithic sample-and-hold amplifier |
جیاکەرەوە سەرەکییەکان
- Directly documented drop-in military-processed option (بەراورد بەAD582SH/883B)
- Monolithic integration reduces the external active-component count (بەراورد بەAD582KD)
- Separate analog and digital ground connections (بەراورد بەAD582/883B)
تێبینییەکانی دیزاین
Do not treat the 25 µs acquisition specification as independent of the external holding capacitor and source impedance. Confirm that the capacitor can charge and settle within the available acquisition interval, then coordinate the sample-to-hold transition with the downstream ADC conversion. Also account for capacitor leakage, dielectric absorption, input bias current, and source impedance when calculating end-to-end hold error.
Place the external holding capacitor and its return connection directly beside the AD582SH pins, and keep the held-signal route short. Route analog input and ground returns separately from digital switching paths because the device provides distinct analog and digital ground connections. This arrangement reduces coupling from switching transients and minimizes parasitic pickup that can appear directly as an error in the held voltage.
Provide a stable supply and return path for the operational-amplifier section inside the IC, while observing the pin-specific guidance in the manufacturer datasheet. Decouple the supply close to the device and verify startup behavior with the intended external capacitor because a large holding capacitor can increase the charge drawn during acquisition. Check worst-case source and sink conditions rather than only the nominal output-current rating.
زانیاری پابەندبوون
Analog Devices states that versions compliant with MIL-STD-883 are available. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not stated in the cited material.