Analog Devices

AD582SH - 25us Sample-and-Hold Amplifier | Analog Devices

MPN: AD582SH ✗ Tapus ng Buhay
15 V Vdss 25 mA Id 10-pin TO-100 Package
MOQ: 1 |

AD582SH Ulas

The Analog Devices AD582SH is a one-channel integrated sample-and-hold amplifier with a 25 µs acquisition time, 25 mA output capability, and a 10-pin TO-100 package. Designed for precision signal acquisition, it combines a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on one monolithic chip. An external holding capacitor completes the sample-and-hold function.

A sample-and-hold amplifier is a data-conversion support circuit that samples an analog input during a defined acquisition interval and stores that voltage on an external capacitor while the remaining circuit performs conversion, comparison, measurement, or signal processing. In the broader hierarchy, it belongs to the amplifier family, specifically instrumentation and signal-conditioning ICs used with ADCs, sensors, test systems, and precision control equipment.

The AD582SH supports input signals up to ±12 V according to the manufacturer documentation and uses separate analog and digital ground connections to improve rejection of ground and switching transients. Its low-leakage hold path is central to preserving the captured voltage during conversion intervals, while the integrated amplifier reduces the number of external active components required. The 25 µs acquisition specification makes the device suitable for moderate-speed data-acquisition channels rather than high-frequency waveform capture.

A typical implementation places the input signal on the amplifier input, connects the prescribed external holding capacitor to the hold terminal, and applies the logic control signal required to switch between acquisition and hold states. Designers should maintain separate analog and ground-return paths, place the holding capacitor close to the device, and account for capacitor leakage, dielectric absorption, input bias current, and settling time when defining system accuracy.

Typical uses include multiplexed data-acquisition systems, analog measurement front ends, industrial process monitoring, laboratory instrumentation, and sampled sensor interfaces. The AD582SH can also precede successive-approximation or pipeline ADCs when a stable input must be presented during conversion. Its integrated architecture is particularly useful where board area, component count, and predictable acquisition behavior matter more than very short acquisition times.

The principal design trade-off is acquisition speed versus hold error. Selecting the external holding capacitor requires balancing settled output voltage, capacitor leakage, dielectric absorption, and the time available to charge it. Keep high-impedance routes short, provide clean grounding, and verify timing against the acquisition interval required by the downstream converter rather than treating the 25 µs figure as independent of capacitor and source impedance.

This page combines the manufacturer's device description with package information, drop-in replacement guidance, application-oriented circuit considerations, and a parameter comparison. It supports faster engineering selection by separating the verified AD582SH characteristics from design assumptions that must be checked against the external holding capacitor and the complete acquisition system.

Mga alternatibo na pwedeng ilagay na AD582SH — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Variante sa Seri na ito

Katulad na modelo sa serye na katugma sa pagpasok AD582SH (parehas na form factor at footprint) — pagkakaiba sa Package, Acquisition Time, Product Type.

Analog Devices
Package: 14-CDIP, 0.300 inch (7.62 mm) body width
Product Type: 1 circuit sample-and-hold amplifier
Ikabit sa AD582SH →
Analog Devices
Package: TO-100 (10-pin metal can)
Acquisition Time: 6 µs (max)

AD582SH/883B

✅ Drop-In
Analog Devices
📦 10-pin TO-100
Sample and Hold Amplifier · 1 · 6 µs (max) · ±15 V · 4.5 mA · -55°C to +125°C · TO-100 (10-pin metal can) · Wire

Magkontak para sa presyo

Tingnan ang Datasheet →

AD582KD

✅ Drop-In
Analog Devices
📦 10-pin TO-100
1 circuit sample-and-hold amplifier · 1 circuit · 14-CDIP, 0.300 inch (7.62 mm) body width · 3 V/us · Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip · Separate analog and digital grounds · External holding capacitor required · Versions available compliant with MIL-STD-883

Magkontak para sa presyo

Tingnan ang Datasheet →

AD582JH

✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo
📦 10-pin TO-100
Same 10-pin TO-100 AD582 family layout; suffix denotes a different hermetic or grade configuration with approximately 25 µs acquisition timing

📋 Alternatibo na Reference (hindi sa katalogo)

AD582JH/883B

✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo
📦 10-pin TO-100
Same 10-pin TO-100 family layout and approximately 25 µs acquisition timing; adds MIL-STD-883 processing while differing in grade suffix

📋 Alternatibo na Reference (hindi sa katalogo)

AD582/883B

✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo
📦 10-pin TO-100
Same AD582 monolithic sample-and-hold function in 10-pin TO-100; adds MIL-STD-883 processing while omitting the more specific commercial ordering suffix

📋 Alternatibo na Reference (hindi sa katalogo)

AD582SH Mga Pinakamataas na Rating at Electrical Characteristics

Product Type Integrated sample-and-hold amplifier
Channel Count 1 channel
Acquisition Time 25 µs
Output Current 25 mA
Volte ng Pagbibigay 15 V
Input Signal Range Up to ±12 V
Architecture Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip
Hold Element External holding capacitor
Ground Configuration Separate analog and digital grounds
Packhaging 10-pin TO-100
Uri ng Pagpapasok Through-hole
Military Version Available in versions compliant with MIL-STD-883

Gabay sa Pin Configuration ng AD582SH 10-pin to-100

Pin configuration para sa AD582SH (10-pin to-100 package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.

Pinout diagram ng 10-pin to-100 package para sa AD582SH

Wala ng detalyadong pinout data na magagamit para sa AD582SH.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

AD582SH ay nararapat para sa 6 aplikasyons: Multiplexed Analog Data Acquisition, Precision Sensor Signal Conditioning, Laboratory Instrumentation Front End, Process Control Signal Capture, Automated Test Equipment, Legacy Measurement System Upgrade.

📊

Multiplexed Analog Data Acquisition

The AD582SH is suitable for a multiplexed measurement channel that must present a stable analog voltage to an ADC during conversion. Its 25 µs acquisition time defines the interval in which the input is sampled, while the integrated low-leakage switch and JFET amplifier support the subsequent hold state. Place the external holding capacitor close to the device and allow acquisition time for the source impedance, capacitor value, and settling behavior. This arrangement reduces the number of discrete active components required around the converter and is useful in industrial measurement systems where repeatable acquisition timing is more important than ultra-high-speed waveform acquisition.

🏭

Precision Sensor Signal Conditioning

The AD582SH can stabilize sensor outputs before downstream measurement or conversion. Its input stage supports signals up to ±12 V, and the low-leakage hold path helps preserve the captured voltage while the system processes the sample. The 25 µs acquisition specification is appropriate for temperature, pressure, position, and slowly changing industrial sensor signals rather than fast transient capture. Care is required with high-impedance sources because bias current, leakage, dielectric absorption, and connector contamination can influence the held value. A short input route and low-leakage external capacitor are particularly important in high-impedance sensor interfaces.

🔧

Laboratory Instrumentation Front End

The AD582SH can serve as the acquisition element in a laboratory instrument that alternates between measuring an input and holding it during display, computation, or reference comparison. Its integrated operational-amplifier, analog-switch, and JFET structure simplifies the analog section while retaining a 25 µs acquisition specification. The separate analog and digital ground connections help reduce susceptibility to ground and switching transients in mixed-signal equipment. For accurate results, route the held signal toward the measuring channel, keep the holding capacitor physically close, and verify droop over the complete conversion and processing interval rather than only the nominal acquisition time.

⚙️

Process Control Signal Capture

The AD582SH can capture an analog process variable and hold it during control-loop calculation or actuator update. The 25 µs acquisition time is well suited to common pressure, flow, level, and temperature monitoring signals, while the low-leakage hold characteristic supports stable conversion of slow-moving quantities. Place the device behind appropriate input conditioning and protection because the measured signal must remain within the documented input limits. Separate analog and ground-return routing reduces switching disturbance. Validate the timing against the controller's update cycle, and include capacitor leakage and dielectric absorption in the total measurement-error budget.

🖥️

Automated Test Equipment

The AD582SH can hold a test-node voltage while automated equipment performs comparison, measurement, or digital processing. A 25 µs acquisition interval allows each measurement point to settle after selection, while the integrated hold circuit reduces the component count of legacy analog measurement fixtures. The 10-pin TO-100 package remains useful for repair and modernization of existing instrument boards. Designers should coordinate the hold command with the test-system timing controller and verify that the external capacitor has adequate leakage margin for the measurement duration. Any replacement must preserve the exact 10-pin connection and acquisition behavior.

🔌

Legacy Measurement System Upgrade

The AD582SH is well suited to maintaining or reproducing legacy analog-measurement equipment that already uses the 10-pin TO-100 AD582 footprint. Its 1-channel, 25 µs sample-and-hold function supports existing acquisition sequencing without requiring a different board pattern. During repair or redesign, confirm the exact ordering suffix, supply voltage, temperature grade, and external capacitor configuration before fitting the part. AD582SH/883B is a practical option when military processing is required, while other family suffixes should be selected according to environmental and qualification requirements rather than package appearance alone.

What is the AD582SH?
The AD582SH is a one-channel integrated sample-and-hold amplifier with a 25 µs acquisition time in a 10-pin TO-100 package. According to the Analog Devices AD582 datasheet, it combines a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on one monolithic chip. An external holding capacitor is required to complete the sample-and-hold function.
What are the key specifications of AD582SH that engineers should know?
The AD582SH is a 1-channel, 25 µs sample-and-hold amplifier packaged in a 10-pin TO-100. The Analog Devices AD582 datasheet describes a monolithic design containing an operational amplifier, low-leakage analog switch, and JFET integrating amplifier. Key application constraints include the external holding capacitor, separate analog and digital ground connections, and support for input signals up to ±12 V.
What is the acquisition time of the AD582SH?
The AD582SH acquisition time is 25 µs. According to the Analog Devices AD582 datasheet and the AD582SH product information, this interval is the principal timing specification for capturing an analog input before the circuit enters its hold state. Actual settling also depends on the external holding-capacitor value, source impedance, leakage, and the amount of time available before the downstream converter samples the held voltage.
Where can I download the AD582SH datasheet PDF?
The official AD582SH datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD582.pdf. The document describes the monolithic sample-and-hold architecture, external holding-capacitor requirement, separate analog and digital grounds, input range, and the availability of MIL-STD-883-compliant versions. Use the manufacturer's document for final pin assignments and electrical limits.
Where can I find the AD582SH pinout?
The AD582SH pinout is shown in the Analog Devices AD582 datasheet under the package and connection information for the 10-pin TO-100 configuration. Use that manufacturer drawing to assign analog inputs, control, supply, ground, and the external holding-capacitor connection. Do not infer pin functions from another package variant, because the SH suffix identifies the commercial 10-pin TO-100 configuration.
What external components does the AD582SH require?
The AD582SH requires an external holding capacitor to complete the sample-and-hold function. The Analog Devices AD582 datasheet also shows the input, control, supply, and grounding connections needed to operate the integrated amplifier and switch. Capacitor selection affects acquisition settling, hold droop, dielectric absorption, and practical accuracy, so evaluate it as part of the complete circuit rather than as an isolated accessory.
Is the AD582SH suitable for ADC signal acquisition?
The AD582SH is suitable for moderate-speed ADC front ends that need a stable analog voltage during conversion. Its 25 µs acquisition time provides a defined sampling interval, while the low-leakage hold network helps preserve the captured value. The system must allow enough acquisition time for the source and holding capacitor to settle, and the downstream ADC timing must be coordinated with the hold command.
AD582SH vs AD582SH/883B - which is better for military applications?
AD582SH/883B is the better starting point for a design requiring MIL-STD-883 processing because the Analog Devices product information specifically identifies MIL-STD-883-compliant AD582 versions. Both parts use the same 10-pin TO-100 sample-and-hold architecture and closely related electrical characteristics. The /883B designation adds the screened or controlled military product designation rather than changing the basic sampling function.
What is the difference between AD582SH and AD582KD?
AD582SH and AD582KD are closely related 10-pin TO-100 versions of the same AD582 sample-and-hold amplifier. The principal documented distinction is the suffix-defined product grade or temperature class, while the core acquisition architecture remains a 25 µs sample-and-hold stage. Consult the manufacturer ordering information to confirm operating-temperature, screening, and procurement requirements before substituting one ordering code for the other.
When should I choose AD582SH over AD582SH/883B?
Choose AD582SH for commercial or industrial applications that require the standard AD582SH ordering configuration but not the MIL-STD-883 product designation. Choose AD582SH/883B when the procurement specification requires the military-processed version. Because both use the same 10-pin TO-100 architecture, the choice is primarily lifecycle, qualification, and ordering-code suitability rather than a different circuit footprint.
What can replace the AD582SH?
AD582SH/883B is the clearest documented drop-in replacement because the manufacturer-related comparison identifies consistent terminals, package, and main performance characteristics. AD582KD and other qualified 10-pin TO-100 AD582 ordering variants may also suit existing AD582 layouts, but their grade and temperature requirements must be checked. A replacement should preserve the 1-channel, 25 µs-class acquisition function and the external holding-capacitor arrangement.
Can AD582SH/883B replace AD582SH without PCB changes?
Yes, AD582SH/883B can replace AD582SH without PCB changes when its electrical and qualification requirements satisfy the design. The documented comparison identifies the same 10-pin TO-100 package and terminals with consistent main performance characteristics. Confirm supply voltage, temperature grade, acquisition timing, and military-processing requirements against the system specification before approving the substitution.
What is the best cross-brand equivalent for AD582SH?
No cross-brand equivalent is established here because a true replacement must preserve the 10-pin TO-100 pinout, sample-and-hold control behavior, acquisition timing, supply requirements, and external holding-capacitor connection. General cross-reference tools identify similar functions, but they do not by themselves prove drop-in compatibility. Select a cross-brand part only after comparing its manufacturer pinout, timing, leakage, and recommended application circuit.
Where to buy AD582SH online and what is its lead time?
Use the Request a Quote form on this page to ask for AD582SH availability, current lead time, minimum order quantity, and authorized sourcing options. Because this is a legacy product, supply status and quantity commitments can change quickly and should be confirmed for the exact ordering suffix. The requested part is AD582SH in the 10-pin TO-100 package, not AD582SH/883B.
How much does the AD582SH cost and is it in stock?
Use the Request a Quote form on this page for current AD582SH commercial terms, stock status, and delivery scheduling. The AD582SH is a legacy sample-and-hold amplifier, and current inventory can vary by package suffix and sourcing channel. State the required quantity, delivery location, and whether the MIL-STD-883 version is acceptable when requesting confirmation.

Impormasyon ng Talumpati sa Engineering for AD582SH — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose AD582SH when restoring or designing a legacy measurement circuit that requires the standard commercial 10-pin TO-100 AD582 configuration and does not require MIL-STD-883 processing. Choose AD582SH/883B when the same physical and functional design must meet a military-processing requirement. AD582KD can suit boards using that established family configuration, but verify its grade and temperature limits before substitution. For a cross-brand replacement, require the identical 10-pin pinout, external holding-capacitor arrangement, sample and hold timing, input range, and supply conditions; a functionally similar amplifier is not automatically a drop-in part. This is a low-to-moderate-speed legacy solution, so select a modern part instead if acquisition time, leakage, package height, or sourcing availability is more important than preserving the original board.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto AD582SH/883B AD582KD AD582JH AD582JH/883B AD582/883B
Product Type 1-channel integrated sample-and-hold amplifier 1-channel integrated sample-and-hold amplifier 1-channel integrated sample-and-hold amplifier 1-channel integrated sample-and-hold amplifier 1-channel integrated sample-and-hold amplifier 1-channel integrated sample-and-hold amplifier
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Package 10-pin TO-100 10-pin TO-100 10-pin TO-100 10-pin TO-100 10-pin TO-100 10-pin TO-100
Channel Count 1 channel 1 channel 1 channel 1 channel 1 channel 1 channel
Internal Architecture Operational amplifier, low-leakage analog switch, and JFET integrating amplifier Monolithic sample-and-hold amplifier Monolithic sample-and-hold amplifier Monolithic sample-and-hold amplifier Monolithic sample-and-hold amplifier Monolithic sample-and-hold amplifier

Pangunahing mga Pagkakaiba

  • Directly documented drop-in military-processed option (kumpara saAD582SH/883B)
  • Monolithic integration reduces the external active-component count (kumpara saAD582KD)
  • Separate analog and digital ground connections (kumpara saAD582/883B)

Talaan ng Disenyo

Do not treat the 25 µs acquisition specification as independent of the external holding capacitor and source impedance. Confirm that the capacitor can charge and settle within the available acquisition interval, then coordinate the sample-to-hold transition with the downstream ADC conversion. Also account for capacitor leakage, dielectric absorption, input bias current, and source impedance when calculating end-to-end hold error.

Place the external holding capacitor and its return connection directly beside the AD582SH pins, and keep the held-signal route short. Route analog input and ground returns separately from digital switching paths because the device provides distinct analog and digital ground connections. This arrangement reduces coupling from switching transients and minimizes parasitic pickup that can appear directly as an error in the held voltage.

Provide a stable supply and return path for the operational-amplifier section inside the IC, while observing the pin-specific guidance in the manufacturer datasheet. Decouple the supply close to the device and verify startup behavior with the intended external capacitor because a large holding capacitor can increase the charge drawn during acquisition. Check worst-case source and sink conditions rather than only the nominal output-current rating.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

Analog Devices states that versions compliant with MIL-STD-883 are available. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not stated in the cited material.

Data napatotohanan sa: 2026-11-18 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

AD582SH datasheet AD582SH datasheet pdf AD582SH pinout AD582SH specifications AD582SH TO-100 sample hold AD582SH 25us acquisition time AD582SH application circuit AD582SH vs AD582SH/883B AD582SH vs AD582KD AD582SH drop-in replacement Analog Devices AD582SH AD582SH price AD582SH stock where to buy AD582SH

Mga kaugnay na Mga Komponente at mga Tuntunin

Analog Devices AD582SH AD582SH/883B AD582KD AD582JH AD582JH/883B AD582/883B sample-and-hold amplifier integrated sample-and-hold amplifier signal-conditioning IC instrumentation amplifier operational amplifier low-leakage analog switch JFET integrating amplifier external holding capacitor TO-100 10-pin TO-100 through-hole package acquisition time hold droop separate analog and digital grounds MIL-STD-883 ADC industrial process monitoring laboratory instrumentation
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ