INA126UA - 36V Precision MicroPower Instrumentation Amplifier | TI
MPN: INA126UA ✓ چالاکINA126UA گشتی
An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals embedded in larger common-mode voltages. Its internal gain stage rejects common-mode noise and converts the differential difference between two inputs into a single-ended output. The INA126 belongs to the broader hierarchy of instrumentation amplifier, precision amplifier, analog signal-conditioning IC, and semiconductor.
The INA126UA uses a two-op-amp architecture with external gain-setting resistors. Its precision input offset voltage supports accurate bridge, current-sense, and sensor measurements, while the 175 µA per channel quiescent current suits battery-powered and portable equipment. The 250 µV input offset specification is particularly useful when the measured differential signal is small relative to the allowed error.
The device supports supply voltages from 2.7 V to 36 V total, corresponding to the documented operating range of ±1.35 V to ±18 V. Its 200 kHz bandwidth suits relatively slow precision measurements rather than high-speed waveform capture. The two-op-amp topology balances low noise and low quiescent current with a practical gain-setting arrangement using an external resistor.
Typical uses include strain-gauge and RTD signal conditioning, low-side current measurement, bridge excitation, biomedical instrumentation, and portable sensor acquisition. For bridge-based sensors, the instrumentation amplifier rejects ground offsets and common-mode interference before the signal reaches an ADC. For battery-powered systems, the 175 µA per channel current helps limit standby consumption.
Choose the INA126UA when the design requires a precision single-channel amplifier with an 8-pin SOIC footprint and very low quiescent current. Verify the selected gain, output swing, supply voltage, bandwidth, and output-reference arrangement against the manufacturer datasheet. Input and reference pins should be routed away from switching nodes and noisy return currents.
This page combines device specifications, verified drop-in alternatives, application guidance, package details, and selection trade-offs to help engineers evaluate the INA126UA before circuit implementation.
جێگرەوەکانی جێگۆڕکێ بۆ INA126UA — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ INA126UA (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Architecture, Common-Mode Rejection Ratio, Supply Voltage Range, Quiescent Current.
INA125U/2K5
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA121UG4
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
INA128UA
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →INA129UA
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →INA142UA
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
INA126UA زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Amplifier Type | Single-channel precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Maximum Supply Voltage | 36 V |
| Minimum Total Supply Voltage | 2.7 V |
| Dual-Supply Operating Range | ±1.35 V to ±18 V |
| ئێستای ئارام | 175 µA per channel |
| Input Offset Voltage | 250 µV maximum |
| Gain Bandwidth | 200 kHz |
| Common-Mode Rejection Ratio | 74 dB minimum |
| Architecture | Two-op-amp instrumentation amplifier |
| Gain Configuration | External resistor configuration |
| پاکێج | 8-pin SOIC |
| جۆری دامەزراندن | Surface mount |
| Signal Type | Differential input, single-ended output |
| Application Category | Low-noise differential signal acquisition |
| دۆخی RoHS | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | unknown |
ڕێنمایی ڕێکخستنی پینی INA126UA 8-pin soic
ڕێکخستنی پین بۆ INA126UA (پاکێجی 8-pin soic). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ INA126UA.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
INA126UA گونجاوە بۆ 6 بەکارھێنانs: Strain-Gauge Bridge Measurement, Portable Battery-Powered Sensor Interface, Low-Side Current Measurement, Medical and Physiological Instrumentation, RTD Temperature Measurement, Industrial Pressure and Level Sensing.
Strain-Gauge Bridge Measurement
The INA126UA fits precision strain-gauge bridge measurement because its differential input architecture rejects common-mode voltage while the 250 µV maximum input offset limits signal-chain error. It can amplify the small millivolt-level differential output generated by a resistive bridge without requiring a separate differential ADC front end. The 36 V maximum supply and 200 kHz bandwidth provide adequate range for slow mechanical or load-cell signals. Set the gain with the manufacturer-specified resistor arrangement, verify input and output common-mode limits, and connect the reference pin according to the required output-zero level.
پێشنیارکراو
Portable Battery-Powered Sensor Interface
The INA126UA is well suited to portable sensor interfaces because its quiescent current is only 175 µA per channel and its total supply range begins at 2.7 V. These characteristics help conserve energy in battery-operated monitors, environmental sensors, and handheld diagnostic instruments. The 250 µV input offset specification supports small differential sensor outputs, while the two-op-amp architecture provides straightforward gain setup. Power-gating and analog settling should be evaluated at the system level, and the reference and feedback paths should be kept quiet to prevent offset and noise from dominating the measurement.
پێشنیارکراو
Low-Side Current Measurement
The INA126UA can acquire a low-side shunt voltage when the shunt common-mode voltage remains within the amplifier's input range. Its 74 dB minimum common-mode rejection ratio helps reject supply ripple and other common-mode disturbances present in power-system return paths. The 250 µV maximum input offset is important because shunt drops at low current can approach the same scale as the error voltage. Use a Kelvin connection from the shunt terminals, maintain the differential input pair over the PCB, and verify that the gain setting keeps the output within the selected supply's output-swing range.
پێشنیارکراو
Medical and Physiological Instrumentation
The INA126UA is appropriate for low-level differential physiological or biomedical signals when the system requires precise offset control, common-mode rejection, and low power consumption. Its 250 µV maximum input offset, 74 dB minimum CMRR, and 175 µA per channel current are useful in compact sensor-conditioning equipment. The 200 kHz bandwidth is suitable for many slow physiological and biochemical signals but not for wideband ECG acquisition. Medical designs must additionally satisfy isolation, leakage-current, safety, and electromagnetic-compatibility requirements at the complete-system level rather than treating the amplifier qualification as a system approval.
پێشنیارکراو
RTD Temperature Measurement
The INA126UA can serve as the low-noise input stage of an RTD measurement circuit when the bridge excitation and output voltage remain within its supply and common-mode limits. The instrumentation-amplifier configuration rejects excitation-signal feedthrough and ground offsets that would otherwise reduce measurement accuracy. Its 250 µV maximum offset supports fine temperature-resolution objectives, and the 36 V maximum supply provides headroom for bridge excitation systems. Select the gain resistor for the RTD and bridge values, account for the amplifier input bias current, and keep the excitation return path separate from sensitive measurement traces.
پێشنیارکراو
Industrial Pressure and Level Sensing
The INA126UA is suitable for precision industrial pressure, level, and position sensors that present differential outputs with substantial common-mode voltage. Its 74 dB minimum CMRR reduces interference from motor drives, switching supplies, and long cable runs, while the 250 µV maximum offset supports low-level sensor accuracy. The 200 kHz bandwidth accommodates most slow process-control signals without requiring a high-speed amplifier. Place input traces as a differential pair, isolate them from switching nodes, and verify surge, isolation, and industrial environmental requirements separately because those protections are not inherent to the 8-pin SOIC amplifier.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ INA126UA — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | INA125U/2K5 | INA121UG4 | INA128UA | INA129UA | INA142UA |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Gain Architecture | INA126 two-op-amp external-resistor configuration | INA125 gain architecture | INA121 gain architecture | INA128 gain architecture | INA129 gain architecture | INA142 gain architecture |
| Signal Type | Differential input, single-ended output | Differential input, single-ended output | Differential input, single-ended output | Differential input, single-ended output | Differential input, single-ended output | Differential input, single-ended output |
جیاکەرەوە سەرەکییەکان
- Lower quiescent current within the comparison set (بەراورد بەINA128UA)
- Precision 250 µV offset specification (بەراورد بەINA121UG4)
- 36 V supply capability for industrial signal ranges (بەراورد بەINA125U/2K5)
تێبینییەکانی دیزاین
Route the two input signals as a closely spaced differential pair and connect directly to the INA126UA input pins. Keep switching-regulator traces, high-current return paths, and digital clocks away from this pair. Use a continuous ground reference beneath the analog section and connect the feedback and reference components close to their associated pins. This layout reduces conversion of common-mode switching noise into differential error before the amplifier's 74 dB CMRR acts on the signal.
Place the supply bypass capacitor immediately across the INA126UA power and ground pins, with the shortest possible ground connection. Add additional bulk capacitance near the source when the amplifier is powered from a long trace or a switching converter. Although the IC consumes only 175 µA per channel, regulator noise can still enter through the supply pins and gain error. Check the amplifier output across the intended frequency range with the actual source impedance and load.
Do not treat a shared SOIC package as proof of functional interchangeability. INA125U/2K5, INA121UG4, INA128UA, INA129UA, and INA142UA use related instrumentation-amplifier architectures but differ in gain selection and performance. Before replacing the INA126UA, compare every numbered pin, gain-setting resistor, output-reference connection, input common-mode range, output swing, bandwidth, and supply requirement. Revalidate the modified circuit at the minimum and maximum operating conditions.
Calculate the effective error from the 250 µV input offset against the smallest differential signal expected from the sensor. If that signal approaches the offset magnitude, consider averaging, higher resolution, calibration, or a lower-offset amplifier family. For bridge or current-shunt measurements, preserve Kelvin connections so voltage-drop in power and ground conductors does not appear as differential input error. The 200 kHz bandwidth must also remain above the intended signal and measurement bandwidth.
زانیاری پابەندبوون
No definitive RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statement was identified in the cited product information. Confirm current declarations with the manufacturer before using the component in a regulated production design.