INA129UA - Precision Instrumentation Amplifier | Texas Instruments
MPN: INA129UA ✓ چالاکINA129UA گشتی
An instrumentation amplifier is a differential amplifier optimized for measuring small signals embedded on larger common-mode voltages. Its signal-path hierarchy is instrumentation amplifier → differential amplifier → analog amplifier → semiconductor. Compared with a conventional difference amplifier, an instrumentation amplifier provides controlled input impedance and accurate differential gain while rejecting common-mode interference from sensors, industrial wiring, and power systems.
Key features include maximum input offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and input-noise performance of 8 nV/√Hz. A single external resistor programs the closed-loop gain, while the three-op-amp architecture maintains common-mode rejection over a useful signal range. Current-feedback input circuitry supports wide bandwidth even at high gain, including 200 kHz at a gain of 100.
The INA129UA combines precision offset and drift characteristics with low quiescent-current operation. Its current-feedback inputs are suited to sensing systems in which source impedance, sensor output level, and system noise must be balanced carefully. The ±40 V input protection rating adds robustness in industrial environments, although protected inputs do not remove the need for appropriate fault-current limiting and supply design.
Typical uses include bridge-amplifier front ends, strain-gauge and pressure-transducer measurement, low-current sensing, medical instrumentation, industrial process control, and battery-powered sensor interfaces. The 8-pin SOIC package supports compact analog modules and standard surface-mount assembly, while the adjustable gain makes one device usable across several signal ranges when the external resistor and sensor-network requirements are properly matched.
For a new design, check input and output common-mode limits, bandwidth at the selected gain, resistor tolerance, and the sensor source impedance before finalizing the layout. Place the gain-setting resistor close to the RG pin, keep input traces short and symmetric, and use a stable reference implementation when the measurement requires nonzero output offset correction.
This product page combines the manufacturer’s device information, pin-level guidance, application analysis, and verified drop-in alternatives to support faster component selection and board-level engineering decisions.
جێگرەوەکانی جێگۆڕکێ بۆ INA129UA — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ INA129UA (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Input Offset Voltage, Gain Range, Quiescent Current, Input Bias Current.
INA128UA
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA163UA
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD8221ARZ
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA129UA زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Amplifier Type | Precision instrumentation amplifier |
| Number of Amplifier Circuits | 1 circuit |
| Input Offset Voltage | 50 µV maximum |
| Input Offset Voltage Drift | 0.5 µV/°C maximum |
| Input Bias Current | 5 nA maximum |
| Common-Mode Rejection Ratio | 120 dB minimum |
| Input Protection Range | ±40 V |
| Supply Voltage Range | ±18 V maximum |
| Minimum Total Supply Voltage | 4.5 V |
| Maximum Gain | 10,000 V/V |
| Minimum Gain | 1 V/V |
| Gain Setting | Single external resistor |
| Bandwidth at Gain 100 | 200 kHz |
| Input Noise at 1 kHz | 8 nV/√Hz typical |
| مەودای پلەی گەرمیی کارکردن | -40 °C to +125 °C |
| پاکێج | 8-pin SOIC (D) |
| جۆری دامەزراندن | Surface mount |
ڕێکخستنی پینی INA129UA
| پین 1 | RG — Gain-setting resistor connection |
| پین 2 | IN- — Inverting input |
| پین 3 | IN+ — Noninverting input |
| پین 4 | V- — Negative supply connection |
| پین 5 | REF — Reference input for output-voltage adjustment |
| پین 6 | OUT — Amplifier output |
| پین 7 | V+ — Positive supply connection |
| پین 8 | RG — Gain-setting resistor connection |
بەکارهێنانە باوەکان
INA129UA گونجاوە بۆ 6 بەکارھێنانs: Strain-Gauge Bridge Measurement, Industrial Pressure Transducer Interface, Battery-Powered Sensor Interface, Medical Signal Acquisition, Low-Current Shunt Measurement, Process-Control Sensor Node.
Strain-Gauge Bridge Measurement
The INA129UA fits strain-gauge and load-cell front ends because its 50 µV maximum input offset voltage and 0.5 µV/°C maximum drift help preserve small full-scale bridge outputs, while its 120 dB minimum common-mode rejection suppresses the larger excitation-related voltage common to both inputs. The gain can be adjusted from 1 to 10,000 V/V with one resistor, allowing the same amplifier family to cover different bridge sensitivities. Place the gain resistor close to the RG pins, maintain symmetric input routing, and verify the amplifier’s input and output common-mode limits against the bridge excitation voltage before production use.
پێشنیارکراو
Industrial Pressure Transducer Interface
The INA129UA is appropriate for industrial pressure and displacement transducers that produce a small differential signal on a substantial common-mode voltage. Its minimum common-mode rejection of 120 dB helps reject switching and grounding disturbances, while the 5 nA maximum input bias current minimizes loading of high-impedance sensor outputs. The ±18 V maximum supply permits bipolar operation where a 5 V sensor interface is not sufficient. Designers should confirm the exact input common-mode range at the selected gain, add appropriate input limiting, and route the differential inputs as a short, symmetric pair to reduce conversion of external interference into signal error.
پێشنیارکراو
Battery-Powered Sensor Interface
The INA129UA supports compact battery-powered sensor interfaces because it is categorized as a low-power instrumentation amplifier and supports operation from a minimum total supply of 4.5 V. Its low input bias current of no more than 5 nA is valuable when the sensor source impedance is high and loading would otherwise reduce the available signal. The adjustable gain permits a direct connection to low-level sensor outputs without an additional fixed-gain stage. Check quiescent current in the selected operating mode, use low-leakage protection components, and verify the output-voltage range when operating from a single supply near the lower system-voltage limit.
پێشنیارکراو
Medical Signal Acquisition
The INA129UA can serve as the analog front end in medical and diagnostic instrumentation when the measured biopotential or sensor output is differential and low level. Its 50 µV maximum offset voltage, 0.5 µV/°C maximum drift, and 120 dB minimum common-mode rejection are useful for preserving small signals in the presence of common-mode interference. The 200 kHz bandwidth at gain 100 supports higher-bandwidth acquisition than a slow precision-only amplifier would provide. Actual medical designs require application-specific safety, isolation, leakage, and validation work; the INA129UA alone does not establish compliance with any medical standard.
پێشنیارکراو
Low-Current Shunt Measurement
The INA129UA is suitable for measuring the voltage generated by a precision shunt when the system needs greater common-mode rejection than a simple differential amplifier. Its 8 nV/√Hz typical input noise at 1 kHz and programmable gain from 1 to 10,000 V/V support measurements spanning millivolt-level shunt drops into the microvolt range. Keep the shunt connections short and use Kelvin routing where practical so lead and contact resistance do not become part of the measurement. Confirm that the shunt common-mode voltage remains inside the operating limits and that the external gain resistor has suitable tolerance and temperature coefficient.
پێشنیارکراو
Process-Control Sensor Node
The INA129UA supports industrial process-control nodes that combine a low-level sensor with an upstream switching supply or other electrically noisy equipment. Its 120 dB minimum common-mode rejection improves rejection of common-mode disturbances, and the input-protection capability of ±40 V adds robustness to qualified sensor wiring. A single external resistor programs gain, reducing the number of external gain-setting components. The design must still include defined input impedance, protected routing, stable grounding, and correct reference treatment. Use the manufacturer pin descriptions during PCB layout and verify both power-supply configurations before finalizing the sensor interface.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ INA129UA — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | INA128UA | INA163UA | AD8221 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Product Type | Precision instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Precision instrumentation amplifier |
جیاکەرەوە سەرەکییەکان
- Defined precision offset and drift (بەراورد بەINA128UA)
- High common-mode rejection (بەراورد بەAD8221)
- Programmable gain with established high-gain bandwidth (بەراورد بەINA163UA)
- Protected differential inputs (بەراورد بەINA128UA)
تێبینییەکانی دیزاین
Route IN+ and IN− as a short, tightly coupled differential pair with symmetrical geometry and a continuous ground reference beneath the pair. Place the external RG resistor close to the two RG pins to minimize parasitic resistance and instability. Keep high-current switching paths and digital return currents away from the input traces because a small differential interference at high gain can become a significant output error.
Decouple each supply pin directly to the ground plane with local high-frequency and bulk capacitance, following the capacitor values and placement guidance in the manufacturer datasheet. Confirm that the sensor common-mode voltage remains inside the amplifier’s operating range for the selected gain and supply configuration. The ±40 V input-protection rating is not a substitute for proper surge limiting or safe fault-current design.
Do not assume that equal package dimensions guarantee a drop-in replacement. Before using INA128UA, INA163UA, or AD8221, compare pin functions, gain-setting equations, input bias current, common-mode range, output swing, bandwidth, and stability with an appropriate reference design. The INA129UA uses two RG connections, so incorrect gain-resistor placement can also affect noise, offset, and stability.
For high-impedance sensors, account for input bias current, sensor source impedance, resistor thermal noise, and the amplifier’s voltage noise at the operating frequency. Use the smallest practical gain that preserves the required signal-to-noise ratio and verify that the selected sensor interface remains stable. For shunt measurements, use Kelvin connections so voltage-drop-producing copper and solder paths do not enter the differential measurement.
زانیاری پابەندبوون
The manufacturer product information identifies the INA129UA as an industrial-temperature, 8-pin SOIC device, but the available technical information does not establish individual compliance statuses.