INA128UA - 130dB CMRR Low-Power Instrumentation Amplifier
MPN: INA128UA ✓ چالاکINA128UA گشتی
An instrumentation amplifier is a specialized amplifier that amplifies the difference between two input signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, controlled differential gain, and strong common-mode rejection. In the power-management hierarchy, the INA128 belongs to the amplifier IC category, where it converts low-level differential sensor outputs into stable signals suitable for measurement, conversion, or control systems.
Key characteristics include an externally adjustable gain from 1 to 10,000 V/V, input protection to ±40 V, and operation across dual supplies of ±2.25 V to ±18 V. The 130 dB CMRR suppresses common-mode noise from sensors and long cables, while the 50 uV maximum offset limits measurement error. Its 700 uA quiescent current also makes it appropriate for compact, low-power instrumentation.
The INA128 uses a versatile three-op-amp architecture with current-feedback input circuitry. This structure supports usable bandwidth even at high gain, including approximately 200 kHz at a gain of 100. A precision gain-setting resistor between the RG pins establishes the differential gain, allowing the same device family to serve bridge, current-shunt, and general differential-signal applications.
Typical uses include precision bridge transducers, strain-gauge sensing, medical instrumentation, industrial process-control equipment, and low-level current measurement. The ±40 V input protection rating can simplify protection around sensor inputs, although system designers must still maintain appropriate common-mode and supply operating limits.
Designers should keep the gain resistor close to the RG pins, provide stable reference and supply bypassing, and check input and output common-mode ranges at the intended gain. Input bias-current errors, source-imbalance effects, resistor tolerance, and printed-circuit-board leakage should be included in the error budget for precision measurements.
This page combines manufacturer specifications, package and pin information, drop-in replacement guidance, comparative parameters, and application-focused engineering guidance to support component selection, PCB implementation, and precision signal-chain design.
جێگرەوەکانی جێگۆڕکێ بۆ INA128UA — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ INA128UA (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Supply Voltage Range, Gain Range, Quiescent Current, Input Offset Voltage.
INA128U
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →INA129U
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →INA120U
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD620ARZ
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →AD8421ARZ
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA128UA زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | Precision low-power instrumentation amplifier |
| Number of Channels | 1 channel |
| Common-Mode Rejection Ratio | 130 dB |
| Minimum Common-Mode Rejection Ratio | 120 dB |
| Maximum Offset Voltage | 50 uV |
| Maximum Offset Voltage Drift | 0.5 uV/degC |
| Maximum Input Bias Current | 5 nA |
| ئێستای ئارام | 700 uA |
| Gain Range | 1 to 10,000 V/V |
| Gain-Bandwidth Product | 1.3 MHz |
| Bandwidth at Gain 100 | 200 kHz |
| Input Protection Range | -40 V to +40 V |
| Supply Voltage Range | -18 V to +18 V |
| Minimum Dual Supply Voltage | -2.25 V to +2.25 V |
| مەودای پلەی گەرمیی کارکردن | -40 degC to +85 degC |
| پاکێج | 8-pin SOIC, 3.90 mm width |
| جۆری دامەزراندن | Surface mount |
| Architecture | Three-op-amp instrumentation amplifier with current-feedback input circuitry |
| دۆخی RoHS | Compliant |
ڕێکخستنی پینی INA128UA
| پین 1 | RG+ — Positive gain-setting resistor terminal |
| پین 2 | IN- — Inverting differential input |
| پین 3 | IN+ — Non-inverting differential input |
| پین 4 | V- — Negative supply connection |
| پین 5 | REF — Reference input for output-voltage offset |
| پین 6 | OUT — Amplified output |
| پین 7 | V+ — Positive supply connection |
| پین 8 | RG- — Negative gain-setting resistor terminal |
بەکارهێنانە باوەکان
INA128UA گونجاوە بۆ 6 بەکارھێنانs: Precision Bridge Transducer Amplification, Industrial Process and Sensor Conditioning, Medical and Diagnostic Signal Conditioning, Low-Level Current-Shunt Measurement, Precision Data Acquisition Front End, Environmental and Smart Sensor Interfaces.
Precision Bridge Transducer Amplification
The INA128UA suits Wheatstone bridge and strain-gauge measurements where millivolt-level differential signals are exposed to common-mode voltage. Its 130 dB CMRR rejects shared interference, while maximum input offset of 50 uV and input bias current of 5 nA limit errors in high-impedance sensing paths. Place the device near the bridge with short, guarded traces, establish the required gain through an RG resistor, and bypass the supply pins locally. This approach is particularly effective when sensor excitation and ground offsets could otherwise dominate the measurement.
پێشنیارکراو
Industrial Process and Sensor Conditioning
For industrial transmitters and process sensors, the INA128UA converts a low-level differential measurement into a signal suitable for downstream conversion or control. The 120 dB minimum CMRR helps suppress interference coupled into long field wiring, and the ±40 V input protection range adds margin around sensor inputs. Its 700 uA quiescent current is useful in compact multi-channel measurement systems. Designers should still use external surge protection where cables leave the enclosure and verify that the operating input common-mode voltage remains valid.
پێشنیارکراو
Medical and Diagnostic Signal Conditioning
The INA128UA can amplify low-level differential physiological or diagnostic signals when low offset, low bias current, and high common-mode rejection are priorities. Maximum offset voltage of 50 uV, 0.5 uV/degC drift, and 5 nA input bias current help preserve accuracy in high-impedance sensor paths. The 130 dB CMRR can reduce interference from common-mode sources. A medical design should additionally evaluate isolation requirements, patient protection, leakage current, noise standards, and application-specific regulatory constraints.
پێشنیارکراو
Low-Level Current-Shunt Measurement
The INA128UA is appropriate for measuring small voltage drops across precision current-shunt resistors in power-conversion and battery systems. Its low input bias current reduces error from high source resistance, while high CMRR rejects voltage common to both shunt terminals. The available gain range supports operation from near-unity gain through high sensitivity configurations. Keep the shunt and amplifier on the same PCB region, use a Kelvin connection, maintain symmetry between input traces, and verify that the shunt voltage and common-mode level remain within the input operating limits.
پێشنیارکراو
Precision Data Acquisition Front End
The INA128UA provides a compact analog front end for precision data-acquisition systems conditioning differential sensor outputs before an ADC. Its 1.3 MHz gain-bandwidth product and approximately 200 kHz bandwidth at gain 100 offer adequate bandwidth for many low-frequency and moderate-bandwidth measurements. The 50 uV offset limit supports accurate conversion of small signals. Select the external gain resistor to keep the ADC input within range, account for ADC noise and reference accuracy, and provide local supply bypassing to prevent acquisition-channel coupling.
پێشنیارکراو
Environmental and Smart Sensor Interfaces
The INA128UA can condition outputs from resistive, piezoresistive, and other high-impedance environmental sensors where common-mode excitation and interference would overwhelm a basic op-amp stage. Its 5 nA maximum input bias current reduces loading of the sensor, and 130 dB CMRR improves rejection of coupled noise. A practical implementation should use guarded input routing, clean sensor excitation, low-leakage PCB materials, and stable gain resistors. The ±40 V input protection rating adds robustness, but the operating common-mode range still requires validation.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ INA128UA — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | INA128U | INA129U | INA120U | AD620 | AD8421 |
|---|---|---|---|---|---|---|
| Package | 8-pin SOIC | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Analog Devices |
جیاکەرەوە سەرەکییەکان
- Supports a wider externally programmed gain range (بەراورد بەINA129U)
- Combines high CMRR with low offset and bias current (بەراورد بەAD620)
- Higher gain capability with a familiar SOIC-8 footprint (بەراورد بەINA120U)
تێبینییەکانی دیزاین
Place the RG resistor directly between the INA128UA RG+ and RG- pins, and route the differential inputs as a closely matched pair. Keep the IN+ and IN- paths away from the supply pins, reference pin, clocked circuitry, and switching-node copper. For high-impedance sensors, use guarding and minimize exposed PCB area around the input terminals because surface leakage can become significant when the measured signal is in the microvolt range.
Decouple the V+ and V- connections locally with the capacitance and ESR range specified in the manufacturer application guidance. Place each capacitor close to its corresponding supply pin and provide a common ground return with low impedance. Check the output and input common-mode limits for every operating condition, including startup, because a valid supply voltage alone does not guarantee that the amplifier remains within its linear input range.
Do not assume that an SOIC-8 footprint guarantees electrical interchangeability. Verify the RG-pin network, REF connection, maximum gain, input bias current, offset limit, CMRR, bandwidth, and supply range of any replacement. For INA129U, specifically recalculate the gain because its 49.4 kohm internal resistor and 1,000 V/V maximum gain differ from the INA128UA configuration. Review the complete manufacturer datasheet before releasing a substitution.
For the best high-gain performance, terminate both inputs in a similar impedance, use a low-temperature-coefficient gain resistor, and avoid asymmetrical leakage paths. Connect the REF pin according to the selected output-reference arrangement and treat REF as a sensitive node rather than a general-purpose routing path. If the source impedance is high, include input bias-current and source-imbalance error in the system calculation rather than relying only on the 50 uV maximum offset specification.
زانیاری پابەندبوون
RoHS compliance is identified for INA128UA. REACH, lead-free status, halogen-free status, and conflict-minerals status are not stated in the cited manufacturer material. AEC-Q100 qualification is not indicated for this industrial instrumentation-amplifier ordering option.