BTS3125TFATMA1 vs BTS3035TFATMA1 Comparison
Detailed side-by-side comparison of BTS3125TFATMA1 by Infineon and BTS3035TFATMA1 by Infineon. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Specification Comparison
| Parameter | BTS3125TFATMA1 | BTS3035TFATMA1 |
|---|---|---|
| Brand | Infineon | Infineon |
| Category | Power MOSFET Drivers | Power MOSFET Drivers |
| Lifecycle Status | Active | Active |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $0.54 | $0.61 |
| Product Type | Single-channel N-channel low-side smart power switch | Low-Side Power Switch |
| Load Current (continuous) | 2 A | β |
| Load Current (pulsed) | [DATA_NEEDED: pulsed drain current limit] | β |
| RDS(on) typical | 250 mΞ© at 5 V Vbb | β |
| Supply Voltage (Vbb, nominal) | 5 V | β |
| Supply Voltage (Vbb, operating) | 5 V to 28 V | β |
| Load Dump Transient Protection | 40 V | β |
| Input Logic Compatibility | 3.3 V / 5 V CMOS | β |
| On-State Resistance (max) | [DATA_NEEDED: maximum RDS(on) over temp] | β |
| Thermal Resistance Junction-to-Ambient | [DATA_NEEDED: theta_JA value] | β |
| Operating Temperature Range | -40Β°C to +150Β°C | -40C to +150C (junction) |
| Over-temperature Shutdown | ~150Β°C with auto-restart | β |
| Short-Circuit Protection | Yes, current-limited | β |
| Over-voltage Protection | Yes (clamping at 40 V) | β |
| ESD Protection | Yes (per IEC 61000-4-2, [DATA_NEEDED: contact/air kV rating]) | β |
| Status Flag Output | Yes (fault feedback) | β |
| Package | PG-TO252-3-313 (DPAK, SC-63) | PG-TO252-3-313 (DPAK) |
| Mounting Type | Surface Mount | Surface Mount |
| MSL Level | [DATA_NEEDED: MSL moisture sensitivity level] | [DATA_NEEDED: MSL moisture sensitivity level] |
| RoHS Status | Compliant | Compliant |
| Technology | β | N-Channel MOSFET |
| Number of Channels | β | 1 |
| Input Type | β | CMOS Logic Level |
| Continuous Drain Current | β | 5 A |
| On-Resistance (RDS(on)) | β | 30 mOhm (typical) |
| Drain-Source Voltage (VDS) Max | β | 40 V |
| Operating Voltage Range | β | 12 V nominal (load-dump tolerant to 40 V) |
| Fault Protection | β | Over-current, Short-circuit, Over-temperature, ESD |
| Status Feedback | β | Yes (open-drain diagnostic output) |
| Reverse Battery Protection | β | Integrated |
| Automotive Grade | β | AEC-Q100 qualified |