BCM6123TD1E5126T0R vs BCM6123TD1E5126T01 Vergleich
Detaillierter Direktvergleich von BCM6123TD1E5126T0R von Vicor und BCM6123TD1E5126T01 von Vicor. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Spezifikationsvergleich
| Parameter | BCM6123TD1E5126T0R | BCM6123TD1E5126T01 |
|---|---|---|
| Marke | Vicor | Vicor |
| Kategorie | DC-DC Converters | DC-DC Converters |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $155,10 | $130,25 |
| Topologie | BCM Bus Converter Module (fixed-ratio isolated DC-DC) | Sine Amplitude Converter (SAC), isolated fixed-ratio |
| Gehäuse | 6123 ChiP through-hole (63.34 x 22.80 x 7.21 mm) | Through-hole ChiP (BCM6123) |
| Eingangsspannungsbereich | 260 V to 410 V DC (nominal 380 V) | 260 V to 410 V |
| Ausgangsspannung | 47.5 V DC nominal (8.1-51.3 V SELV family range) | — |
| Output Current | 25.7 A continuous | — |
| Output Power | Approximately 1.2 kW continuous at full load | — |
| Peak Efficiency | 97.9% | 97.9% |
| Power Density | 1876 W/in3 | 1876 W/in³ |
| Isolation Voltage | 4242 VDC | — |
| Transformation Ratio (K) | 1/8 (K=1/8) | 1/8 (K=1/8) |
| Switching Topology | Vicor ZVS/ZCS sine amplitude converter | — |
| Control Interface | Analog (Rev T suffix) | — |
| Parallel Operation | Yes - supports multi-kW arrays | Supported for multi-kW arrays |
| Protections | OV, OC, UV, short-circuit, thermal shutdown | OV, OC, UV, short circuit, thermal |
| Montageart | Through-hole ChiP | — |
| Betriebstemperatur | [DATA_NEEDED: operating temperature range] | -40°C to +125°C (see derating curves) |
| MTBF | [DATA_NEEDED: MTBF figure] | — |
| RoHS-Status | [DATA_NEEDED: RoHS compliance status] | [DATA_NEEDED: RoHS status] |
| Nominal Input Voltage | — | 380 V |
| Output Voltage (nominal) | — | 47.5 V |
| Continuous Output Current | — | 25.7 A |
| Continuous Output Power | — | 1220 W (47.5 V x 25.7 A) |
| Isolation Voltage (Input to Output) | — | 4242 VDC |
| Device Grade | — | T01 (telemetry/control) |
| Cooling Method | — | Forced air or cold-plate recommended for full load |