MPVZ7025GC6U vs MPXV7025GC6U Vergleich
Detaillierter Direktvergleich von MPVZ7025GC6U von NXP Semiconductors und MPXV7025GC6U von STMicroelectronics. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Spezifikationsvergleich
| Parameter | MPVZ7025GC6U | MPXV7025GC6U |
|---|---|---|
| Marke | NXP Semiconductors | STMicroelectronics |
| Kategorie | Pressure Sensors | Pressure Sensors |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Lagerstatus | In Stock | In Stock |
| Stückpreis (USD) | $6,95 | $8,40 |
| Pressure Type | Compound / Gage (Vacuum + Positive) | Compound (Gauge/Vacuum) |
| Pressure Range | -25 kPa to +25 kPa (±3.63 PSI) | -25 kPa to +25 kPa (-3.63 to +3.63 PSI) |
| Ausgangstyp | Analog Voltage (ratiometric) | Analog Voltage, Ratiometric |
| Ausgangsspannungsbereich | 0.2 V to 4.7 V | 0.2 V to 4.7 V |
| Versorgungsspannung | 4.75 V to 5.25 V (5 V typical) | — |
| Sensitivity (nominal) | [DATA_NEEDED: mV/kPa exact figure from datasheet curve] | — |
| Accuracy | ±2.5% (typical) | ±5 % (after calibration) |
| Betriebstemperatur | -40°C to +125°C | 0 °C to +85 °C |
| Storage Temperature | [DATA_NEEDED: storage temp range] | — |
| Port Style | Vertical compound male 0.13" (3.17 mm) tube | Top, Axial, Male 3.18 mm (0.13 in) Tube |
| Port Material | Sifel / Silicone gel (chemical-resistant) | — |
| Gehäuse | 8-SMD Module (CASE 98ASB17760C, SM Outline) | 8-SMD, Gull Wing, Top Port (SOP 8) |
| Montageart | Surface Mount (SMT), Tube Pack | Surface Mount |
| Response Time | 1 ms (typical) | — |
| AEC-Q100 | Automotive grade (per Freescale/NXP marketing) | — |
| RoHS-Status | Compliant | Compliant |
| Sensitivity | — | 90 mV/kPa (nominal) |
| Supply Voltage (VCC) | — | 4.75 V to 5.25 V (5 V typical) |
| Versorgungsstrom | — | [DATA_NEEDED: supply current] |
| Port Termination | — | Axial barbed tube port |
| Technology | — | Piezoresistive MEMS, on-chip signal conditioned, temperature compensated, calibrated |
| MSL-Level | — | [DATA_NEEDED: MSL level] |