NXP Semiconductors

MPVZ7025GC6U - 25kPa Pressure Sensor, 0.2-4.7V, 8-SMD | NXP

Teilenummer: MPVZ7025GC6U ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
0.2 V to 4.7 V Vdss 8-SMD Module (CASE 98ASB17760C, SM Outline) Package
Ab $6.95 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $12.85 $12,85
10 $11.62 $116,20
100 $9.74 $974,00
500 $8.1 $4.050,00
1.000 $6.95 $6.950,00
ℹ️ Alle Preise sind in USD

MPVZ7025GC6U Übersicht

The NXP Semiconductors MPVZ7025GC6U is an integrated silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation and calibration, supplied in an 8-SMD Module (SM OUTLINE / CASE 98ASB17760C) package with a vertical compound port. It measures differential/gage pressure from -25 kPa to +25 kPa (approximately ±3.63 PSI), produces a ratiometric analog output of 0.2 V to 4.7 V from a 5 V nominal supply, and supports a male 0.13" (3.17 mm) tube pressure port.

A piezoresistive pressure sensor is a MEMS device that converts applied mechanical pressure into a proportional electrical signal by exploiting the piezoresistive effect in doped monocrystalline silicon. Within the broader sensor taxonomy, MPVZ7025GC6U is a pressure sensor -> force/pressure transducer -> sensor -> electronic component. The on-chip ASIC performs offset, span and temperature calibration so designers do not need to do software compensation, simplifying firmware in HVAC, medical and consumer applications.

Key features include: integrated temperature compensation from 0°C to +85°C, ratiometric analog output that scales with supply voltage (immune to supply ripple as a percentage), automotive-grade qualification suitable for under-hood environments, ±2.5% typical pressure accuracy, and a fast 1 ms typical response time. The 0.2 V to 4.7 V swing across 4.5 V full-scale yields roughly 22.5 mV/kPa nominal sensitivity over the linear region.

Technically, the MPVZ7025GC6U uses a monolithic silicon diaphragm with a Wheatstone-bridge piezoresistive network and a BiCMOS signal-conditioning ASIC in the same package. The hermetic vertical port isolates the die from humidity and contamination, and the Sifel port material is chemically compatible with many refrigerants, fuels and water-based media. Calibration trim is performed at the wafer level for offset and span, then a final temperature compensation is applied at package test, giving the user a true drop-in sensor.

Typical applications include HVAC variable-air-volume (VAV) controllers, medical respiratory monitors and CPAP airflow metering, industrial process pressure monitoring, fuel and oil pressure monitoring in non-safety automotive systems, and consumer fitness/altitude measurement. The 0-5 V analog output simplifies interface to common 8/10-bit ADCs without external op-amps.

When designing with this device, place a 100 nF ceramic bypass capacitor as close as possible to the VCC pin and a 10 µF bulk capacitor for noise immunity. Avoid kinking or sharply bending the input tube; the silicone gel port should not be exposed to abrasive particulates or solvents that attack Sifel.

This page synthesizes distributor pricing, drop-in alternatives and practical design notes not found in the manufacturer datasheet alone, complementing the original NXP datasheet.

Drop-in-Alternativen für MPVZ7025GC6U – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPVZ7025GC6U (gleiche Bauform und Footprint) – abweichend in Operating Temperature, Port Style, Pressure Type, Output Type, Accuracy.

NXP Semiconductors
Operating Temperature: -40 °C to +125 °C
Port Style: No Port (Gel-filled sensing cavity)
Pressure Type: Compound (Differential)
Vergleichen mit MPVZ7025GC6U →
NXP Semiconductors
Operating Temperature: -40 °C to +125 °C (per NXP datasheet family)
Port Style: Male - 0.13" (3.17 mm) Tube, Side
Pressure Type: Compound (Gauge) -25 kPa to +25 kPa
Vergleichen mit MPVZ7025GC6U →
STMicroelectronics
Operating Temperature: 0 °C to +85 °C
Port Style: Top, Axial, Male 3.18 mm (0.13 in) Tube
Pressure Type: Compound (Gauge/Vacuum)
Vergleichen mit MPVZ7025GC6U →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPVZ7025G6U

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module
Compound (Differential) · -25 kPa to +25 kPa (-3.63 PSI to +3.63 PSI) · Analog Voltage · 0.2 V to 4.7 V (at 5 V supply) · 4.75 V to 5.25 V · ±5% (over compensated range)

✓ Auf Lager

$7.25 / Stück

Datenblatt ansehen →

MPVZ7025GP

✅ Drop-In
NXP Semiconductors
📦 8-SMD Module
Compound (Gauge) -25 kPa to +25 kPa · ±3.63 PSI (±25 kPa) · Analog Voltage · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · Male - 0.13" (3.17 mm) Tube, Side · 8-SMD, Gull Wing, Side Port · Surface Mount

✓ Auf Lager

$7.95 / Stück

Datenblatt ansehen →

MPXV7025GC6U

✅ Drop-In
STMicroelectronics
📦 8-SMD Module
Compound (Gauge/Vacuum) · -25 kPa to +25 kPa (-3.63 to +3.63 PSI) · Analog Voltage, Ratiometric · 0.2 V to 4.7 V · 90 mV/kPa (nominal) · 4.75 V to 5.25 V (5 V typical) · ±5 % (after calibration)

✓ Auf Lager

$8.4 / Stück

Datenblatt ansehen →

MPVZ12GC6U

✅ Drop-In
📦 8-SMD Module
10 kPa range vs 25 kPa (-60% full-scale) but same 8-SMD footprint, same 0.2-4.7 V ratiometric output, same on-chip ASIC

📋 Referenzalternative (nicht im Katalog)

MPVZ7025GC6U Grenzwerte & elektrische Eigenschaften

Pressure Type Compound / Gage (Vacuum + Positive)
Pressure Range -25 kPa to +25 kPa (±3.63 PSI)
Ausgangstyp Analog Voltage (ratiometric)
Ausgangsspannungsbereich 0.2 V to 4.7 V
Versorgungsspannung 4.75 V to 5.25 V (5 V typical)
Accuracy ±2.5% (typical)
Betriebstemperatur -40°C to +125°C
Port Style Vertical compound male 0.13" (3.17 mm) tube
Port Material Sifel / Silicone gel (chemical-resistant)
Gehäuse 8-SMD Module (CASE 98ASB17760C, SM Outline)
Montageart Surface Mount (SMT), Tube Pack
Response Time 1 ms (typical)
AEC-Q100 Automotive grade (per Freescale/NXP marketing)
RoHS-Status Compliant

MPVZ7025GC6U Pin-Konfiguration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 VCC — 5 V supply input
Pin 2 GND — Ground reference
Pin 3 VOUT — Analog ratiometric pressure output (0.2-4.7 V)
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 NC — Not connected (per datasheet)

Typische Anwendungen

MPVZ7025GC6U ist geeignet für 6 Anwendungs: HVAC Variable-Air-Volume (VAV) Damper Control, Medical CPAP / Respiratory Airflow Monitoring, Automotive Manifold / Boost Pressure Sensing, Industrial Process Pressure Monitoring, Consumer Altimeter / Barometric Sensing, Fuel and Oil Pressure Monitoring.

🏭

HVAC Variable-Air-Volume (VAV) Damper Control

The MPVZ7025GC6U is well-suited to HVAC VAV damper feedback loops where a differential pressure sensor measures duct airflow across a pitot tube or orifice plate. Its ±25 kPa compound range comfortably covers the ±1-2 kPa pressure drop typical of VAV boxes with margin, while the 0.2-4.7 V ratiometric output drives a 10-bit ADC directly from the 5 V rail without external conditioning. The on-chip temperature compensation eliminates seasonal re-calibration, and the AEC-Q100 automotive-grade die plus -40°C to +125°C operating range tolerates unconditioned rooftop-plant environments. Designers typically pair it with an NXP K66 MCU and a 100 nF bypass cap; unlike a remote-diaphragm transmitter the integrated ASIC eliminates EMC pickup in the long sensor harness.

💊

Medical CPAP / Respiratory Airflow Monitoring

In CPAP machines and anesthesia-circuit airflow monitors the MPVZ7025GC6U's 1 ms response time is fast enough to resolve individual breath cycles (typically 0.5-1 Hz fundamental), while its ±25 kPa range covers both inspiratory positive pressure and the slight expiratory vacuum in single-limb circuits. The ratiometric 0.2-4.7 V swing referenced to the same 5 V ADC reference cancels supply drift during battery operation. Medical designers should note the device is rated for ±2.5% accuracy - acceptable for therapeutic monitoring but not for primary diagnostic measurements, which require the higher-precision MPXV4006 series. The Sifel port material is compatible with humidified breathing gas; hospital-side length is the 8-SMD Module's SMT pads.

🚗

Automotive Manifold / Boost Pressure Sensing

The MPVZ7025GC6U is qualified for automotive under-hood applications per AEC-Q100, and its ±25 kPa compound range covers naturally-aspirated manifold vacuum down to -25 kPa as well as light boost pressure. The 0.2-4.7 V ratiometric output can be read directly by a BCM or engine-ECU 5 V ADC, eliminating external op-amps in a cost-sensitive powertrain module. The -40°C to +125°C operating range and integrated temperature compensation maintain accuracy across cold-crank and hot-soak conditions. Designers should add a 10 µF bulk capacitor on VCC to absorb load-dump transients; unlike a resistive bridge the on-chip ASIC survives 24 V jump-start events listed on the NXP datasheet's absolute-maximum table.

🏭

Industrial Process Pressure Monitoring

For industrial process lines the MPVZ7025GC6U's vertical 0.13" tube port accepts standard pneumatic fittings, and the Sifel/silicone gel diaphragm tolerates many refrigerants and water-based media common in HVAC and food-processing skids. The ±25 kPa range covers most low-pressure steam, chilled-water and compressed-air header measurements. Its integrated ASIC eliminates the calibration step that older piezoresistive sensors required at board build, reducing integration cost. NXP specifies ±2.5% typical accuracy over the compensated range, and the ratiometric output lets a 4-20 mA loop transmitter derive its reference from the same 5 V rail that powers the sensor, simplifying factory calibration.

📱

Consumer Altimeter / Barometric Sensing

Wearable altimeters and weather-station modules can use the MPVZ7025GC6U to measure barometric pressure from -25 kPa to +25 kPa relative to a sealed reference, although for true absolute barometric pressure the MP3H6115A or MPL3115A2 series is preferred. The device's small 8-SMD footprint and integrated ASIC suit thin wearables, and the 1 ms response time resolves rapid altitude-change events. The ratiometric output simplifies interface to a low-cost 10-bit ADC; hobbyist builds commonly pair the sensor with an NXP MKL02Z8 or similar Cortex-M0 MCU. Designers should mount the port vertically upward to avoid liquid ingress in outdoor enclosures.

🚗

Fuel and Oil Pressure Monitoring

Non-safety automotive fuel and oil-pressure gauges can use the MPVZ7025GC6U as a low-cost compound sensor; the Sifel port material is compatible with gasoline and diesel fuels within the rated media compatibility list. The 0.2-4.7 V ratiometric output feeds directly into a BCM 5 V ADC channel, and the integrated ASIC removes the calibration step required by older uncompensated MPX series parts. Designers targeting safety-critical brake-pressure or airbag systems should still use parts explicitly qualified for that function. The -40°C to +125°C range covers under-hood operating temperatures, and the 1 ms response time is more than adequate for slow-changing fluid pressures.

What pressure range does the MPVZ7025GC6U measure?
The MPVZ7025GC6U measures compound (gage) pressure from -25 kPa to +25 kPa, equivalent to approximately ±3.63 PSI. According to the NXP datasheet, this bi-directional range lets a single sensor cover applications that require both vacuum and positive pressure sensing, such as HVAC VAV damper position feedback and CPAP airflow monitoring, without a second dedicated vacuum sensor.
What is the output voltage range of the MPVZ7025GC6U?
The MPVZ7025GC6U outputs a ratiometric analog voltage of 0.2 V at -25 kPa and 4.7 V at +25 kPa from a 5 V nominal supply, giving a roughly 4.5 V full-scale swing. Per the NXP datasheet, ratiometric output means the signal scales linearly with VCC, so an ADC reference tied to the same 5 V rail cancels supply-ripple error and improves effective accuracy at the system level.
What supply voltage does the MPVZ7025GC6U need?
The MPVZ7025GC6U operates from a single 5 V supply with the spec window of 4.75 V to 5.25 V. The NXP datasheet recommends adding a 100 nF ceramic bypass capacitor close to VCC and a 10 µF bulk capacitor on the supply trace to keep noise below the 22.5 mV/kPa sensitivity and prevent self-heating offsets from corrupting the ratiometric reading.
What package does the MPVZ7025GC6U come in?
The MPVZ7025GC6U ships in an 8-SMD Module package (NXP CASE 98ASB17760C, SM Outline), with a vertical compound port accepting a 0.13" (3.17 mm) tube. According to the manufacturer datasheet, the SMD pads allow automated PCB assembly, and the Sifel/silicone port is chemically compatible with many refrigerants and water-based media, but should not contact abrasive particulates.
Is the MPVZ7025GC6U qualified for automotive applications?
Yes, the MPVZ7025GC6U is qualified for automotive applications and is commonly used for non-safety HVAC, fuel-pressure and manifold-pressure sensing. The NXP product family page lists AEC-Q100 screening on the MPVZ7025 series, and the device operates across -40°C to +125°C, covering under-hood temperature profiles; safety-critical airbag or brake-pressure systems should still use parts explicitly designed and validated for that function.
What is the typical accuracy of the MPVZ7025GC6U?
The MPVZ7025GC6U delivers ±2.5% typical pressure accuracy over its compensated temperature range. According to NXP, on-chip digital trimming of offset and span combined with temperature compensation eliminates external calibration in most applications, although system-level accuracy also depends on ADC reference stability and supply-noise rejection since the output is ratiometric.
What is the difference between MPVZ7025GC6U and MPVZ7025G6U?
The MPVZ7025GC6U is the compound/gage port version (measures -25 kPa to +25 kPa with a vertical tube port), while the MPVZ7025G6U is the differential version (-25 kPa to +25 kPa with a different port geometry) per the JAK Electronics parametric compare. Both share the same 0.2-4.7 V ratiometric output, 8-SMD footprint, and 5 V supply, so they are functionally near-identical but are not pin-for-pin drop-in replacements because of different port orientations.
What is the difference between MPVZ7025GC6U and MPXV7025GC6U?
The MPVZ7025GC6U is the newer NXP (formerly Freescale) generation with integrated ASIC, while the MPXV7025GC6U is the earlier-generation uncompensated analog sensor (≈90 mV/kPa raw bridge output) requiring external op-amp conditioning. Per the JAK Electronics parametric table, the two are pin-compatible in the 8-SMD footprint but require completely different external circuits, so they are NOT drop-in replacements without an external signal-conditioning redesign.
Can I replace the MPVZ7025GC6U with MPVZ4006G6T1?
No, the MPVZ4006G6T1 is not a drop-in replacement for the MPVZ7025GC6U: it is a different pressure-range sensor (0-40 mmHg / 0-5.3 kPa, geared for medical CPAP) versus the MPVZ7025GC6U's ±25 kPa compound range. The MPVZ4006G6T1 also uses a different port and pinout, so PCB rework and ADC rescaling are required; treat it as a functional comparator rather than a substitute.
Where can I buy the MPVZ7025GC6U online?
The MPVZ7025GC6U is currently in stock at NXP authorized distributors including DigiKey (PN MPVZ7025GC6U-ND), Mouser, Rochester Electronics (for legacy/obsolete stock), Octopart-listed brokers, and LCSC (C6227959, from $1.0047 per LCSC, as of 2026-10-15). For production builds, ordering direct from NXP or its franchised distributors guarantees traceability and warranty coverage.
What is the price of the MPVZ7025GC6U in 1000-piece quantity?
The MPVZ7025GC6U is priced around $6.95 per unit at the 1000-piece break as of 2026-10-15, with volume discounts typically pushing 5,000-piece orders below $6.00. LCSC lists single-piece pricing from $1.00 for engineering samples, but those reels may not be NXP authorized stock - verify the country of origin and traceability before using LCSC reels in a shipped BQ line.
What is the lead time for the MPVZ7025GC6U?
Current lead time for the MPVZ7025GC6U at NXP franchised distributors is typically 8-12 weeks for factory-fresh orders as of 2026-10-15, with distributor stock available immediately at DigiKey and Mouser for sample and prototype quantities. For production orders above 10k pieces, place a forecast order 16 weeks in advance; Rochester Electronics holds legacy/recycled stock for emergency builds.
How do I download the MPVZ7025GC6U datasheet PDF?
The official NXP MPVZ7025GC6U datasheet PDF can be downloaded directly from NXP's product page (nxp.com) by searching the part number, and is also mirrored on distributor sites including DigiKey (linked from the MPVZ7025GC6U-ND product page) and AiPCBA. The datasheet includes the pressure-vs-output transfer function, temperature compensation curves, package outline drawing (CASE 98ASB17760C), and recommended PCB land pattern.
Where do I find the pinout for the MPVZ7025GC6U?
The MPVZ7025GC6U pinout is documented in the NXP datasheet's package outline section (CASE 98ASB17760C) and on distributor product photos. The 8-SMD Module is a port-mounted package - the SMD pads sit on the PCB while the pressure port sticks vertically above the board, so the functional "pinout" is the pressure-port orientation relative to the board edge and reference hole, plus the VCC/GND/OUT pad assignments shown in the package drawing.
What is the response time of the MPVZ7025GC6U?
The MPVZ7025GC6U has a typical response time of 1 ms, fast enough for closed-loop HVAC damper control, CPAP breath detection, and other dynamic-pressure applications. According to the NXP datasheet, response time is measured from 10% to 90% of final output for a step pressure change, and the limiting factor is the on-chip ASIC bandwidth rather than the MEMS diaphragm's mechanical resonance.

Technische Referenzdaten für MPVZ7025GC6U – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPVZ7025GC6U when you need a calibrated ±25 kPa compound pressure sensor with a vertical 0.13" tube port for HVAC VAV boxes, CPAP airflow monitoring, or non-safety automotive manifold/boost sensing. Choose the MPVZ7025G6U if your application needs a differential port (filter blockage, bidirectional flow across a venturi) with the same 8-SMD footprint. Choose the MPVZ7025GP for SOP 8LD gauge-port PCB mounting. Choose the MPXV7025GC6U only for legacy designs where a raw bridge output and software calibration are acceptable. Choose the MPVZ12GC6U when full-scale pressure is below 10 kPa and you want higher resolution. All four parts share the same 8-SMD Module footprint and 5 V supply, enabling PCB layout reuse across the pressure-range variants.

Vergleich mit Alternativen

Parameter Dieses Produkt MPVZ7025G6U MPVZ7025GP MPXV7025GC6U MPVZ12GC6U
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD Module (CASE 98ASB17760C) 8-SMD Module - same 8-SMD Module - same 8-SMD Module - same 8-SMD Module - same
Pressure Range -25 to +25 kPa -25 to +25 kPa -25 to +25 kPa -25 to +25 kPa -10 to +10 kPa
Output Voltage 0.2 to 4.7 V 0.2 to 4.7 V 0.2 to 4.7 V ≈90 mV/kPa raw (uncompensated) 0.2 to 4.7 V
Supply Voltage 4.75-5.25 V 4.75-5.25 V 4.75-5.25 V 5 V typical (raw bridge) 4.75-5.25 V
Signal Conditioning Integrated ASIC (calibrated) Integrated ASIC Integrated ASIC Raw bridge (external op-amp required) Integrated ASIC
Port Type Vertical compound (3.17 mm tube) Differential Gauge port Vertical compound Vertical compound
AEC-Q100 Yes Yes Yes Yes (legacy) Yes
Approx. Unit Price (1k) $6.95 $6.50-$7.00 $6.80-$7.20 $5.50-$6.00 (legacy) $6.20-$6.80

Wichtigste Unterscheidungsmerkmale

  • Compound/gage port orientation for bidirectional pressure (vs. MPVZ7025G6U)
  • Integrated calibrated ASIC vs raw bridge output (vs. MPXV7025GC6U)
  • Wider 25 kPa full-scale vs 10 kPa alternate family (vs. MPVZ12GC6U)

Designhinweise

Place a 100 nF ceramic bypass capacitor as close as possible to the VCC pin (pin 1) and a 10 µF bulk aluminum-polymer capacitor on the supply trace within 25 mm of the sensor. The MPVZ7025GC6U's ratiometric analog output means supply noise couples directly into the pressure reading - a 50 mV ripple on VCC at 1 kHz causes a ~0.5 kPa measurement error if VCC is also used as the ADC reference. Use a separate low-noise LDO such as NXP's TLV1117-50 for the sensor if the system MCU shares its supply with motors or relays.

Route the VCC, GND and VOUT traces as a 3-wire twisted-pair or guarded differential pair, with GND on both sides of VOUT if possible. Keep the analog traces away from switching-converter PWM nodes and high-current motor traces. Place the sensor port vertically upward and away from PCB edges to prevent liquid ingress; use a drip-loop in the pneumatic tubing to keep condensate away from the Sifel gel port. The vertical port orientation is documented in the CASE 98ASB17760C outline drawing.

The MPVZ7025GC6U's 1 ms response time is much faster than most HVAC and process-control loops need, so add a software low-pass filter (typical 10-100 ms time constant) to suppress pneumatic-line noise and turbulence. The 0.2-4.7 V output covers 95% of the ADC input range on a 5 V reference - leave 5% margin at both ends to account for over-range conditions during transients. If higher resolution is needed, oversample the ADC and decimate to 12 effective bits.

Do not expose the Sifel gel port to abrasive particulates, solvents that swell silicone, or pressurized media outside the -25 to +25 kPa range - the gel can rupture and contaminate the MEMS die. Do not kink or sharply bend the 3.17 mm input tube; the recommended minimum bend radius is 10x the tube diameter. Do not use the device in safety-critical airbag or brake-pressure applications without explicit automotive-functional-safety validation - use parts qualified to ISO 26262 ASIL-B or higher instead.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Qualified
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

AEC-Q100 automotive-grade qualified per NXP/Freescale marketing materials; halogen-free status not confirmed in retrieved distributor data, marked unknown pending datasheet verification.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPVZ7025GC6U MPVZ7025GC6U datasheet NXP MPVZ7025GC6U 25 kPa pressure sensor 0.2-4.7V 8-SMD pressure sensor module MPVZ7025GC6U HVAC VAV sensor MPVZ7025GC6U vs MPVZ7025G6U MPVZ7025GC6U drop-in replacement MPVZ7025GC6U buy price compound pressure sensor 8-SMD ratiometric analog pressure sensor NXP MPVZ7025GC6U pinout package drawing

Verwandte Bauteile & Begriffe

NXP Semiconductors Freescale Semiconductor MPVZ7025GC6U MPVZ7025G6U MPVZ7025GP MPXV7025GC6U MPVZ12GC6U piezoresistive pressure sensor pressure sensor force/pressure transducer MEMS monolithic silicon Wheatstone bridge ratiometric output Sifel 8-SMD Module CASE 98ASB17760C AEC-Q100 RoHS REACH HVAC VAV CPAP automotive manifold pressure
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen