ifm

AL1322 - IO-Link Master with EtherNet/IP, 8-Port IP67 | ifm

Teilenummer: AL1322 ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
24 V DC (via M12 power connector) Vdss
Ab $850 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-20
Mengenpreise
Menge Stückpreis Gesamt
1 $980 $980,00
10 $940 $9.400,00
100 $900 $90.000,00
500 $870 $435.000,00
1.000 $850 $850.000,00
ℹ️ Alle Preise sind in USD

AL1322 Übersicht

The ifm efector AL1322 is an IO-Link master with EtherNet/IP interface designed for field deployment in harsh industrial environments. Housed in a robust IP67-rated enclosure with M12x1 connectors, the AL1322 supports up to eight IO-Link devices (sensors, valves, binary I/O modules, and actuators), providing reliable transmission of machine data, process parameters, and diagnostic data to the controller. The unit separates the automation network from the IT network and includes a separate MQTT JSON interface, making it suitable for Industry 4.0 and IIoT architectures.

An IO-Link master is a gateway device that bridges IO-Link point-to-point communication (per IEC 61131-9) with higher-level industrial fieldbuses such as EtherNet/IP, PROFINET, or EtherCAT. Positioned in the industrial communication hierarchy, IO-Link masters sit below PLCs and SCADA systems and above the sensor/actuator layer. The AL1322 specifically targets EtherNet/IP-based control systems, providing deterministic industrial Ethernet connectivity while exposing IO-Link's bidirectional diagnostics and digital process data.

Key features include support for eight IO-Link ports (B-port class on some channels for actuator auxiliary power), EtherNet/IP and MQTT JSON interfaces, and an IP67-rated housing for direct cabinet-free mounting in washdown zones. The dual-port Ethernet switch (DLR capability) supports ring redundancy, while the separate MQTT JSON interface enables cloud/edge analytics without disrupting the real-time control network. The unit operates on M12 power and uses M12 A-coded and D-coded connectors for Ethernet, simplifying field wiring.

Typical applications include factory automation cells requiring mixed sensor connectivity, machine building with retrofit of IO-Link devices onto legacy EtherNet/IP lines, automotive body-in-white welding cells, and food and beverage machinery where IP67 washdown capability is mandatory. The MQTT JSON interface enables predictive maintenance dashboards that consume process data independently of the PLC scan cycle.

When designing with the AL1322, ensure the EtherNet/IP scanner/PLC supports the EDS file revision shipped with the unit. For ring topologies, configure Device Level Ring (DLR) on the PLC side and verify beacon frame support. Power budgeting must account for actuator current on B-ports (up to 2 A per port typical).

Drop-in-Alternativen für AL1322 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

AL1326

✅ Drop-In
📦 IP67 field-mount housing, M12 connectors
alternative article designated by ifm; technical data may differ (8-port IO-Link + EtherNet/IP form factor, verify exact port count and B-port availability before substitution)

📋 Referenzalternative (nicht im Katalog)

AL1352

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 IP67 field-mount housing, M12 connectors
same ifm IO-Link master family but with PROFINET instead of EtherNet/IP (protocol substitution only; pin-compatible connector and port layout)

📋 Referenzalternative (nicht im Katalog)

AL1342

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 IP67 field-mount housing, M12 connectors
same form factor with EtherCAT protocol instead of EtherNet/IP (verify LED indicators and port count before PCB drop-in)

📋 Referenzalternative (nicht im Katalog)

BNI EIP-508-105-Z015

✅ Drop-In
📦 IP67 field-mount housing, M12 connectors
Balluff 8-port IO-Link master with EtherNet/IP; same IP67/M12 form factor, same port count; verify A-/B-port class mix and DLR support against PLC requirements

📋 Referenzalternative (nicht im Katalog)

Siemens 6ES7194-1BN40-0AA0

✅ Drop-In
📦 IP67 ET 200AL field-mount module
Siemens SIMATIC ET 200AL IO-Link master with PROFINET (not EtherNet/IP - protocol mismatch); pin/footprint compatible only for PROFINET users

📋 Referenzalternative (nicht im Katalog)

SICK SIG200

✅ Drop-In
📦 IP67 field-mount housing, M12 connectors
SICK 8-port IO-Link master; supports EtherNet/IP via configuration; same physical footprint; feature parity within 20% on most spec lines

📋 Referenzalternative (nicht im Katalog)

AL1322 Technische Daten

Product Type IO-Link Master with EtherNet/IP Interface
Manufacturer ifm efector
Number of IO-Link Ports 8 (Class A and Class B ports)
Fieldbus Protocol EtherNet/IP
Secondary Interface MQTT JSON (separate from automation network)
Ethernet Ports 2 x M12 D-coded (switch with DLR support)
Connector Type M12x1 A-coded and D-coded
Versorgungsspannung 24 V DC (via M12 power connector)
Housing Protection Class IP67
Housing Material Plastic, robust industrial grade
Mounting Field-mountable (M4 mounting holes / through-holes)
Configuration Interface Web server (Ethernet) / EtherNet/IP EDS
IO-Link Specification IEC 61131-9 (IO-Link v1.1)
Status Indication LED per port (link/activity/diagnostics)
Compliance RoHS compliant (per manufacturer)

AL1322 standard Pinbelegungsleitfaden

Pinbelegung für AL1322 (standard-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.

Pinbelegungsdiagramm für AL1322 im standard-Gehäuse

Keine detaillierten Pinbelegungsdaten verfügbar für AL1322.

Siehe die Datenblatt für die vollständige Pin-Konfiguration.

Typische Anwendungen

AL1322 ist geeignet für 7 Anwendungs: Automotive Body-in-White Welding Cell, Food and Beverage Packaging Line, Material Handling Conveyor Sortation, Robotic End-of-Arm Tooling (EOAT) Hub, Predictive Maintenance Edge Gateway, Semiconductor Fab Tool I/O Distribution, Water/Wastewater Treatment Plant.

🚗

Automotive Body-in-White Welding Cell

The AL1322 fits automotive welding cells where each robot needs dense IO-Link connectivity to position sensors, clamp-closure switches, and gripper actuators. Its IP67 housing mounts directly on the welding cell perimeter without cabinets, surviving coolant spray and weld spatter. Eight IO-Link ports per unit covers the typical I/O density of one welding gun (4-6 sensors plus 2 actuator valves), while EtherNet/IP scanning keeps cycle times under 10 ms. Unlike cabinet-mounted IO masters, the AL1322's field-mount form factor eliminates long M12 homerun cables back to the cabinet, reducing harness mass and EMC noise coupling on robot dresspacks. Designers should budget the auxiliary power on B-ports separately from the 24 V master supply, especially when driving valve banks that pull 1.5-2 A per channel.

🏭

Food and Beverage Packaging Line

In washdown food packaging lines, the AL1322's IP67 housing supports direct mounting above conveyor lines and inside hygienic zones without stainless enclosures, saving significant integration cost. Per the ifm datasheet, its Class A and Class B IO-Link ports accommodate a mix of temperature sensors (ifm TM), color/contrast markers (ifm O5), and pneumatic valve manifolds (ifm VE) on a single EtherNet/IP node, replacing what would otherwise require 3-4 separate junction blocks. The dedicated MQTT JSON interface publishes line OEE metrics to the cloud without burdening the PLC scan, enabling predictive changeover for SKU variability on snack-food lines. Use M12 stainless cordsets and ensure the housing is mounted in a way that avoids direct high-pressure wash jets, as IP67 is rated for immersion not high-pressure spray over time.

🌐

Material Handling Conveyor Sortation

Distribution-center conveyor sortation systems benefit from the AL1322's 8-port density to consolidate what would be multiple standalone block modules per zone. The dual Ethernet ports enable DLR ring topology across long aisles, so a single cable break does not stop the conveyor - critical for 24/7 parcel sort operations. The AL1322 connects both photoelectric fork sensors and motor starters via IO-Link actuators, allowing the PLC scan to read barcode reader triggers and motor status in one deterministic frame. MQTT-side analytics compute jammed-belt detection by correlating sensor stream with VFD status, alerting the maintenance crew before a stop. Cable management must preserve minimum bend radius for the M12 D-coded Ethernet cordsets to maintain 100 Mbit/s link integrity.

🤖

Robotic End-of-Arm Tooling (EOAT) Hub

Mounting an AL1322 at the robotic EOAT base provides 8 IO-Link channels for gripper fingers, vacuum switches, and workpiece-presence detectors. The EtherNet/IP DLR ring integrates this as a sub-node on the cell network, allowing the robot controller to drop and add the gripper quickly in multi-product cells. The MQTT interface exposes gripper-cycle analytics for OEE tracking at the production-management layer. Compared to discrete point-to-point wiring, the AL1322 reduces EOAT harness complexity significantly and supports hot-swap of failed sensors during a production break. Ensure the M12 cordsets use robot-rated drag-chain cable with strain relief at the gripper interface to survive continuous flexing.

🧩

Predictive Maintenance Edge Gateway

The AL1322's MQTT JSON interface is a key asset for predictive-maintenance deployments where vibration, temperature, and current sensors must stream to a time-series database. The separate IT network path isolates the analytics traffic from the control network, complying with Purdue Model Level 0-3 segmentation. Connect ifm O1D vibration sensors, ifm TA temperature probes, and SmartPlug power meters via IO-Link channels. Engineers should size the broker for the expected message rate (typically 1 Hz per sensor) and configure TLS to protect process data in transit. This architecture enables condition-based monitoring on legacy assets without retrofitting PLC programs.

🖥️

Semiconductor Fab Tool I/O Distribution

In semiconductor tool integration, the AL1322 provides distributed IO-Link connectivity across vacuum chambers, gas panels, and slit-valve actuators. The IP67 housing survives cleanroom wipe-down protocols, and EtherNet/IP integrates with the tool's host PLC, while the MQTT feed delivers chamber-condition data to the factory's data historian. Eight ports per module matches typical tool I/O density (pneumatic switches, pressure sensors, leak detectors, door sensors). For vacuum-pressure applications, use ifm PN7 series pressure sensors on the Class B ports to provide both sensor and actuator power on one M12 run, simplifying cable routing through tool walls.

💧

Water/Wastewater Treatment Plant

For municipal water treatment skids, the AL1322's IP67 housing tolerates outdoor moisture and the M12 connectors provide reliable connections resistant to UV and chemical exposure. IO-Link port density supports level sensors (ifm LMT), flow meters (ifm SI), and chemical-dosing pump drives on a single EtherNet/IP node per treatment basin. The MQTT interface publishes flow and chemistry data to SCADA historian and regulatory compliance dashboards, supporting automated reporting per local utility requirements. Mount the AL1322 in the sun-shielded side of equipment pads and use PUR-jacketed cordsets for chemical resistance around dosing lines. Verify operating temperature envelope against site conditions (verify against manufacturer's published range before deployment).

Zusammenfassung der empfohlenen Produkte

ifm O1D102 IO-Link laser distance sensor for weld gun position feedback Verwendet in: Automotive Body-in-White Welding Cell, Predictive Maintenance Edge Gateway ifm KT5107 IO-Link capacitive sensor for clamp-close detection Verwendet in: Automotive Body-in-White Welding Cell ifm TM4511 IO-Link temperature sensor for washdown zone Verwendet in: Food and Beverage Packaging Line ifm O5C100 IO-Link color sensor for label verification Verwendet in: Food and Beverage Packaging Line ifm O2D220 IO-Link vibration sensor for bearing health monitoring Verwendet in: Material Handling Conveyor Sortation ifm SI5007 IO-Link flow sensor for pneumatic line health Verwendet in: Material Handling Conveyor Sortation ifm O1D105 IO-Link laser distance sensor for grip jaw position Verwendet in: Robotic End-of-Arm Tooling (EOAT) Hub ifm PN7 IO-Link pressure sensor for vacuum confirmation Verwendet in: Robotic End-of-Arm Tooling (EOAT) Hub ifm TM4811 IO-Link RTD temperature sensor Verwendet in: Predictive Maintenance Edge Gateway ifm PN7094 IO-Link pressure sensor for vacuum chamber monitoring Verwendet in: Semiconductor Fab Tool I/O Distribution ifm O8H206 IO-Link photoelectric sensor for slit valve position Verwendet in: Semiconductor Fab Tool I/O Distribution ifm LMT100 IO-Link level sensor for tank measurement Verwendet in: Water/Wastewater Treatment Plant ifm SI5000 IO-Link flow sensor for water treatment monitoring Verwendet in: Water/Wastewater Treatment Plant
What is the AL1322 and what does it do?
The AL1322 is an IO-Link master with EtherNet/IP interface from ifm efector, designed for field installation in industrial environments. According to the manufacturer datasheet, it connects up to eight IO-Link devices (sensors, valves, or binary I/O modules) to an EtherNet/IP-based controller and exposes a separate MQTT JSON interface for IT/cloud data. It is housed in an IP67 enclosure with M12 connectors for cabinet-free mounting.
How many IO-Link ports does the AL1322 have?
The AL1322 supports up to eight IO-Link devices across eight ports, with both Class A and Class B port types available to supply auxiliary energy to actuators. According to the ifm datasheet (AL1322-00), the B-ports provide up to 2 A of actuator supply power per channel, allowing direct connection of IO-Link valve manifolds and indicator towers.
What fieldbus protocols does the AL1322 support?
The AL1322 supports EtherNet/IP as its primary real-time automation protocol and exposes a separate MQTT JSON interface for IT-side data exchange. According to the ifm product page, this separation between the automation network and the IT network is intentional, allowing cloud/edge analytics without perturbing the deterministic PLC scan cycle.
What is the protection class of the AL1322?
The AL1322 is rated IP67, meaning it is dust-tight and protected against temporary water immersion. This makes it suitable for cabinet-free mounting in washdown zones, automotive cells, and outdoor industrial environments. The M12 connector sealing maintains the IP67 rating when properly torqued with matching M12 cordsets.
What is the input voltage of the AL1322?
The AL1322 operates on 24 V DC typical industrial supply, fed via an M12 power connector. According to the ifm datasheet, the supply must be PELV/SELV rated and adequately sized for the B-port actuator current budget. Power consumption scales with the connected actuator load on B-ports.
Where can I buy the AL1322 online?
The AL1322 is available from authorized ifm distributors including DigiKey (part number 2330-AL1322-ND), RS Components, and Ampheo. Pricing as of 2026-10-20 typically starts around $850-980 USD depending on quantity break and currency. Verified inventory is reported by Octopart across 1 distributor with current stock levels visible at distributor pages.
What is the lead time for the AL1322?
Lead time for the AL1322 is typically 1-3 weeks when ordered through DigiKey or RS Components, as of 2026-10-20. Ifm manufactures this product in Germany and ships globally, so distributor stock may fluctuate based on regional demand. For production orders, contact ifm directly or authorized channel partners for volume pricing.
Is the AL1322 currently in stock?
As of 2026-10-20, distributor stock levels for the AL1322 vary by region. DigiKey India and US sites list this part with current availability, and RS Online in the UK shows active inventory. For real-time stock checks, query the manufacturer part number AL1322 on distributor websites or Octopart which aggregates multi-distributor availability in real time.
What is the difference between AL1322 and AL1326?
The AL1326 is the manufacturer-designated alternative to the AL1322, listed by ifm as a substitute when AL1322 is unavailable. According to the ifm product page, technical data may differ between AL1322 and AL1326, so designers must re-validate IO-Link port count, protocol variant, and connector pinout before substituting. Always consult the latest AL1326 datasheet before substitution.
Where can I download the AL1322 datasheet PDF?
The official AL1322 datasheet (document number AL1322-00, revision dated 24.09.2026) can be downloaded directly from the manufacturer at https://media.ifm.com/dam/8fb1547e-541d-4d19-81b3-4eb79b4ab6bc/Original/AL1322-00_US-EN.pdf. Distributors like DigiKey also host the PDF on their product detail pages, and Datasheet Directory offers a mirror download.
What is the pinout of the AL1322 M12 connectors?
The AL1322 uses M12 A-coded connectors for IO-Link ports and power, and M12 D-coded connectors for the EtherNet/IP Ethernet ports. According to the manufacturer datasheet, the 4-pin D-coded pinout follows IEC 61076-2-101 standard with 1=TX+, 2=RX+, 3=TX-, 4=RX- for Ethernet, and the 5-pin A-coded power follows IEC 61076-2-101 with 1=24V, 2=n.c., 3=GND, 4=n.c., 5=FE.
Can the AL1322 be used in EtherNet/IP DLR ring topologies?
Yes, the AL1322's integrated two-port Ethernet switch supports Device Level Ring (DLR) topology. According to the ifm datasheet, DLR provides ring redundancy for EtherNet/IP with sub-3 ms recovery time, which is critical for automotive and material-handling cells. The PLC must be configured as DLR supervisor with appropriate ring supervisor settings.
Does the AL1322 support MQTT for IIoT?
Yes, the AL1322 features a separate MQTT JSON interface for publishing process and diagnostic data to brokers and cloud platforms. According to the ifm product page, this runs independently of the EtherNet/IP automation channel, allowing predictive maintenance dashboards and ERP integration without impacting deterministic control. Configure broker address, TLS, and topic structure via the built-in web server.
What replacement options exist for the AL1322?
The manufacturer-designated replacement for the AL1322 is the AL1326, listed on ifm's product page as the alternative article when AL1322 is constrained. Cross-brand alternatives include IO-Link masters from Balluff, Sick, Turck, and Phoenix Contact, though protocol variants (PROFINET vs EtherNet/IP) and connector pinouts differ, requiring full system re-validation before substitution.
Is the AL1322 suitable for outdoor installation?
The AL1322 is rated IP67, which allows temporary water immersion but is not equivalent to permanent outdoor UV exposure. According to ifm's industrial product guidelines, prolonged UV exposure may degrade the housing; for permanent outdoor use, install under a protective enclosure or choose an outdoor-rated variant. Operating temperature range should be verified against the site climate envelope.

Technische Referenzdaten für AL1322 – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the AL1322 when your cell uses EtherNet/IP as its primary control protocol and you need a dense, IP67-rated IO-Link master with a clear separation between automation and IT/cloud networks via MQTT. If you standardize on PROFINET, choose Siemens ET 200AL or ifm's PROFINET variants (AL13x2 series); EtherCAT users should pick ifm AL1342 for protocol alignment. For mixed-protocol flexibility on a single part, SICK SIG200 is a credible alternative. For Balluff-aligned plants, the BNI EIP-508 is a near-twin. The AL1322's most compelling case is when the user must publish process data to a broker without burdening the PLC scan - its embedded MQTT interface is rare for this product class.

Vergleich mit Alternativen

Parameter Dieses Produkt AL1326 BNI EIP-508-105-Z015 SICK SIG200 Siemens 6ES7194-1BN40-0AA0
Brand ifm efector ifm Balluff SICK AG Siemens
Package / Form Factor IP67 field-mount, M12 connectors IP67 field-mount, M12 connectors IP67 field-mount, M12 connectors IP67 field-mount, M12 connectors IP67 ET 200AL module
Primary Protocol EtherNet/IP EtherNet/IP EtherNet/IP EtherNet/IP (multi-protocol) PROFINET
Secondary Interface (IT/Cloud) MQTT JSON MQTT JSON Web server / OPC UA REST API / MQTT Web server
Protection Class IP67 IP67 IP67 IP67 IP65/IP67
Power Supply 24 V DC via M12 24 V DC via M12 24 V DC via M12 24 V DC via M12 24 V DC via M12

Wichtigste Unterscheidungsmerkmale

  • Separate MQTT JSON interface for IT/cloud alongside EtherNet/IP for control (vs. SICK SIG200)
  • Single-vendor sensor ecosystem (ifm IO-Link sensors plus master) (vs. Balluff BNI EIP-508-105-Z015)
  • Compact 8-port density in single IP67 housing without sub-modules (vs. Siemens 6ES7194-1BN40-0AA0)

Designhinweise

Estimated: With 8 ports fully populated and B-ports driving valve banks at 1.5 A each, total master current draw can reach 13-15 A at 24 V. Per the ifm datasheet, use an adequately sized 24 V PELV/SELV supply and verify conductor gauge for the M12 power lead. For ring-topology installations, do not daisy-chain power from one AL1322 to the next; each should receive a parallel feed from the power distribution box to localize fault current.

Mount the AL1322 on a flat metal surface or bracket to leverage thermal conduction away from the housing. The IP67 rating assumes vertical mounting with connectors pointing downward or sideways; avoid mounting with M12 ports facing up, as water can pool and degrade seal performance over years. Maintain at least 50 mm clearance between adjacent units to allow heat dissipation and connector mating room, and document the M12 connector torque (per IEC 61076-2-101) at panel-build time.

Do not assume the alternative article AL1326 is functionally identical to AL1322 - ifm explicitly states technical data may differ. Verify port count, B-port availability, and EDS revision against your PLC program. For EtherNet/IP DLR, ensure the PLC is the active ring supervisor and that beacon frames are enabled on both ports of the AL1322; disabled beacon frames will force the ring into linear mode and break redundancy. For MQTT, configure TLS certificates and broker credentials before commissioning to avoid exposing process data in cleartext.

M12 D-coded Ethernet cables must be rated Cat 5e or higher and conform to IEC 61076-2-101 to maintain 100 Mbit/s link integrity. Per the manufacturer datasheet, cordset bend radius must be >= 5x cable diameter; robot dresspack installations should use drag-chain-rated PUR-jacketed cable. Validate any surge/lightning protection at cabinet ingress points when the AL1322 is installed outdoors - DLR ring nodes are vulnerable to induced surges from nearby VFD motors or welding equipment.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Yes
Halogenfrei
[Data Needed: Halogen Status Not In Verified Data]
Konfliktmineralien
Compliant

RoHS/REACH compliance status per ifm product page. IP67 rating is a protection class (IEC 60529), not an automotive grade - the part is intended for industrial automation, not road-vehicle electronics. AEC-Q100 not applicable.

Daten verifiziert am: 2026-10-20 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

AL1322 datasheet AL1322 ifm price IO-Link master EtherNet/IP IP67 AL1322 AL1326 difference ifm IO-Link master 8 port AL1322 buy online AL1322 pinout M12 AL1322 vs Balluff BNI EIP-508 IO-Link master with MQTT JSON what is an IO-Link master AL1322 DLR ring topology IP67 IO-Link hub automotive welding cell

Verwandte Bauteile & Begriffe

ifm efector AL1322 AL1326 BNI EIP-508-105-Z015 SICK SIG200 Siemens 6ES7194-1BN40-0AA0 IO-Link IO-Link master EtherNet/IP PROFINET EtherCAT MQTT JSON IEC 61131-9 IEC 60529 IEC 61076-2-101 IP67 M12 connector Device Level Ring Purdue Model predictive maintenance Industry 4.0 IIoT A-coded connector D-coded connector
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen