CD4046BF - CMOS Micropower Phase-Locked Loop | Texas Instruments
Teilenummer: CD4046BF ✓ Aktiv| Menge | Stückpreis | Gesamt |
|---|---|---|
| 1 | $30.1173 | $30,12 |
| 10 | $30.1173 | $301,17 |
| 100 | $30.1173 | $3.011,73 |
| 500 | $30.1173 | $15.058,65 |
| 1.000 | $30.1173 | $30.117,30 |
CD4046BF Übersicht
A phase-locked loop is a feedback-control system in which an internal voltage-controlled oscillator is adjusted until its output frequency or phase agrees with a reference input. In the CD4046BF, the signal-input amplifier feeds the selected phase-comparator path, while the VCO provides the tunable output. The PLL can therefore compare an incoming reference against a divided or generated frequency and present an error voltage for loop filtering and frequency control. The loop filter is external, allowing designers to tune loop bandwidth, capture behavior, damping, and output jitter according to the application.
The key features of the CD4046BF are its 3 V to 18 V supply range, micropower CMOS operation, integrated VCO, two phase comparators, and broad -55 C to +125 C temperature rating. The VCO is linear, making the output frequency controllable by an external voltage. The common input amplifier and comparator input simplify use with external frequency-divider and loop-filter networks. The CD4046BF is a useful building block when a system needs both frequency synthesis and flexible feedback-loop implementation rather than a fixed-frequency oscillator.
The device uses analog control techniques around a CMOS digital-compatible integrated circuit. The VCO output frequency depends on its control voltage and external timing components, while the phase comparator converts phase or frequency differences into an error signal. Designers should account for comparator type, loop-filter transfer function, VCO gain, divider ratio, reference frequency, and component tolerances. In practical designs, a low-pass filter commonly connects the comparator output to the VCO control input, and a frequency divider may be inserted between the VCO output and comparator input when integer multiplication is required.
Typical applications include FM and AM demodulation, tone decoding, frequency synthesis, frequency multiplication, frequency division, phase discrimination, motor-speed-related modulation, communications interfaces, and instrumentation. The 16-CDIP package is particularly useful where through-hole assembly, rugged mechanical construction, or a wide temperature range is preferred over a surface-mount footprint. Designers should confirm timing, output-drive, supply-current, and component-temperature requirements against the manufacturer datasheet before production release.
The most important design consideration is selecting the correct comparator and calculating the loop filter around the intended reference frequency. A filter that is too aggressive can increase noise or slow acquisition, while an insufficiently filtered loop can jitter or oscillate. Keep the VCO timing components and sensitive comparator nodes away from noisy switching paths, use a stable low-noise control voltage, and check the maximum operating frequency for the selected external components. The CD4046BF is not a power semiconductor, so a safe operating area specification is not applicable.
Drop-in-Alternativen für CD4046BF – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit CD4046BF (gleiche Bauform und Footprint) – abweichend in Mounting Type, Package, Product Type.
Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:
CD4046BE
✅ Drop-In✓ Auf Lager
$0.4105 / Stück
Datenblatt ansehen →MC14046B
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
HEC4046B
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
HEF4046B
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
CD4046BF Technische Daten
| Product Type | CMOS micropower phase-locked loop (PLL) |
| Supply Voltage Range | 3 V to 18 V |
| Maximum Frequency | 2.4 MHz |
| Betriebstemperaturbereich | -55 C to +125 C |
| VCO Type | Low-power linear voltage-controlled oscillator |
| Phase Comparator Count | 2 |
| Common Input Amplifier | 1 |
| Common Comparator Input | 1 |
| Gehäuse | 16-lead CDIP |
| Montageart | Through-hole |
| Logic Family | CMOS |
| Datasheet Page Count | 16 pages |
| Supplier Price as of 2026-10-23 | From $30.1173 |
| Supplier Availability as of 2026-10-23 | In stock at LCSC |
| Input Signal | Signal input through common amplifier |
| Output Function | Frequency synthesis and phase-locked control |
| SOA | Not applicable |
CD4046BF 16-lead cdip Pinbelegungsleitfaden
Pinbelegung für CD4046BF (16-lead cdip-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für CD4046BF.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
CD4046BF ist geeignet für 6 Anwendungs: FM Demodulation, Frequency Synthesis, Tone Decoding, Frequency Division and Multiplication, Communications and Modulation Interfaces, Industrial Control and Instrumentation.
FM Demodulation
The CD4046BF is suited to FM demodulation because its VCO and phase comparator form a feedback loop that can track an incoming carrier while an external loop filter sets the bandwidth. With a 3 V to 18 V supply and operation up to 2.4 MHz under the verified conditions, the device can serve low-frequency and instrumentation-style demodulation circuits. The designer must select the comparator mode, calculate the loop filter, and verify capture range and linearity with the actual carrier frequency. External timing components set the VCO operating point, while the filter removes high-frequency error components and determines audio or data bandwidth. Because the 16-CDIP package is through-hole, it is useful for prototypes, industrial equipment, and repair or legacy-system designs.
Empfohlen
Frequency Synthesis
CD4046BF can implement a programmable frequency synthesizer by comparing a stable reference with a divided VCO output. The VCO control voltage sets the generated frequency, and the phase comparator drives an external loop filter that corrects phase and frequency error. The 3 V to 18 V supply range supports integration into CMOS-compatible control systems, while the verified maximum frequency of 2.4 MHz provides a useful ceiling for many low- and mid-frequency designs. A frequency divider between the VCO output and comparator input enables integer multiplication relationships. Timing-component tolerance, loop stability, reference jitter, and settling time should be evaluated together rather than optimizing only the nominal carrier frequency.
Empfohlen
Tone Decoding
The CD4046BF is useful for tone decoding because the PLL can lock to a selected audio-frequency or communications tone and provide a control signal when the input frequency falls within the designed capture range. The external loop filter determines how quickly the decoder responds and how broadly it accepts frequencies near the target. Designers should calculate the VCO frequency range from the timing network, account for comparator choice, and test temperature and supply variation. The 16-CDIP package supports through-hole assembly in alarm panels, tone-based control systems, and legacy communications equipment. The main design trade-off is between a narrow, selective filter and a wider filter with faster acquisition or greater susceptibility to adjacent-tone errors.
Empfohlen
Frequency Division and Multiplication
CD4046BF can support frequency division or multiplication when a counter or divider is placed in the feedback path between the VCO output and the phase comparator. The loop then drives the VCO until the divided output agrees with the reference, allowing the VCO output to operate at a controlled multiple of the reference frequency. This architecture is useful in frequency standards, clock-generation modules, and legacy communications equipment. The external divider ratio, loop filter, and VCO timing network must be designed together to maintain capture margin and suppress false locks. The 3 V to 18 V supply range and -55 C to +125 C rating make temperature behavior an important verification item, especially when component tolerances or VCO gain vary across the operating range.
Empfohlen
Communications and Modulation Interfaces
CD4046BF is applicable to communications and modulation interfaces where a received frequency must be tracked, filtered, or translated into a stable control voltage. The phase comparator converts phase or frequency error into a feedback signal, and the VCO supplies the adjustable local oscillator. With operation from 3 V to 18 V, the device fits systems that combine CMOS control logic with analog signal conditioning. The design should verify input amplitude limits, comparator mode, loop bandwidth, and output loading against the manufacturer datasheet. The 16-CDIP package makes it practical for through-hole industrial communications equipment, laboratory instruments, and repair platforms where a surface-mount redesign is undesirable. External filtering is essential for controlling modulation bandwidth and rejecting unwanted frequency components.
Empfohlen
Industrial Control and Instrumentation
CD4046BF can serve industrial control and instrumentation systems that need closed-loop frequency regulation, phase comparison, or synchronous reference generation. Its -55 C to +125 C operating-temperature rating is particularly useful where equipment must operate across a broad environmental range, subject to component-level derating and verified test requirements. The VCO and phase comparators provide flexible analog feedback around an external loop filter and divider. In practice, the circuit can generate a control voltage proportional to frequency deviation, lock a local oscillator to an external reference, or support measurement systems that need stable frequency relationships. Keep sensitive timing and comparator nodes away from switching-power nodes, use stable reference components, and validate lock range and timing margin at the expected supply tolerances.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für CD4046BF – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | CD4046BE | MC14046B | HEC4046B | HEF4046B | CD4046BNSR |
|---|---|---|---|---|---|---|
| Package | 16-CDIP | 16-CDIP candidate | 16-CDIP candidate | 16-CDIP candidate | 16-CDIP candidate | 16-SOP candidate; not a physical drop-in |
| Brand | Texas Instruments | Texas Instruments | onsemi | Signetics | Signetics | Texas Instruments |
Wichtigste Unterscheidungsmerkmale
- Broad temperature-rated 16-CDIP implementation (vs. CD4046BE)
- Integrated dual phase-comparator architecture (vs. MC14046B)
- Through-hole CD4046BF construction (vs. CD4046BNSR)
Designhinweise
Keep the VCO timing network, phase-comparator inputs, and loop-filter components close to the CD4046BF and away from switching regulators, high-current return paths, and long unprotected traces. The PLL can amplify delay and noise through its feedback loop, so route the comparator and VCO-control nets as short, quiet analog paths. Use a solid ground reference and keep external divider outputs away from the reference-input node where possible.
Design the external loop filter around the intended reference frequency and VCO gain rather than selecting a generic capacitor value. The CD4046BF’s PLL response depends on comparator type, VCO control sensitivity, divider ratio, and phase margin. Verify startup, capture, lock range, and settling across the 3 V to 18 V supply range. Do not infer current consumption or timing limits from the distributor listing; use the manufacturer datasheet.
Do not treat a 4046-family PLL as a drop-in solely because the function is similar. Confirm every pin, the comparator mode, VCO frequency range, supply limits, output loading, temperature grade, and package drawing. The verified comparison identifies CD4046BE as a possible equivalent, but the supplied data does not establish every operating parameter. Validate lock behavior in hardware before releasing a replacement to production.
Compliance-Informationen
The supplied verified data does not include explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statements. The component is presented as an integrated circuit, so SOA is not applicable.