INA103KPG4 Übersicht

Texas Instruments INA103KPG4 is a low-noise, low-distortion instrumentation amplifier with one signal path, 1 nV/√Hz input noise, 1000 MHz gain-bandwidth product, ±25 V supply capability, and greater than 100 dB CMRR in a 16-pin PDIP package. The device is designed for precision differential-signal measurement where low input noise, high common-mode rejection, and accurate gain control are important.

An instrumentation amplifier is a specialized analog amplifier that amplifies the difference between two input signals while rejecting voltage common to both inputs. In the signal-chain hierarchy, the INA103 belongs to instrumentation amplifiers, a precision-oriented subclass of amplifiers and analog integrated circuits. Its differential architecture supports sensor interfaces, current-loop receivers, and measurement systems in which ground offsets or other common-mode voltages could otherwise overwhelm the wanted signal.

Key features include an input-noise density of 1 nV/√Hz, a gain-bandwidth product of 1000 MHz, and CMRR above 100 dB. The listed THD+N specification is 100, indicating low distortion in precision signal chains. Internal gain-setting resistors are specified as 100 kΩ, while the device supports output voltages up to ±10 V and output current up to 2.5 mA. These characteristics favor applications requiring high bandwidth and low-noise amplification rather than only basic differential gain.

The INA103 is also identified as an upgrade to the AD625 and uses built-in gain-setting resistors. Such internal networks simplify instrumentation-amplifier implementation by reducing the number of external precision resistors required for fixed-gain configurations. Designers still need to observe the complete electrical limits, package thermal constraints, output-current capability, and application-specific settling requirements when assigning gain and bandwidth.

Typical uses include bridge-transducer interfaces, precision current-shunt measurements, industrial sensor conditioning, laboratory instrumentation, and low-level differential-signal acquisition. The 1 nV/√Hz noise density is particularly relevant when the sensor output is small, while CMRR above 100 dB helps preserve that output when common-mode voltage changes are present.

A key design consideration is that high gain-bandwidth product does not guarantee useful signal bandwidth at every gain setting. Input and output impedances, internal gain resistors, source impedance, and the selected gain must be evaluated together. Decoupling should follow the manufacturer’s recommended supply and layout practices to prevent supply noise or instability from degrading measured performance.

This page combines manufacturer specifications, package information, verified component listings, drop-in replacement assessment, comparison parameters, and practical application guidance to support faster instrumentation-amplifier selection and PCB design.

Drop-in-Alternativen für INA103KPG4 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit INA103KPG4 (gleiche Bauform und Footprint) – abweichend in Gain-Bandwidth Product.

Texas Instruments
Gain-Bandwidth Product: 6 MHz
Vergleichen mit INA103KPG4 →

INA103KP

✅ Drop-In
Texas Instruments
📦 16-pin PDIP
Low-noise, low-distortion instrumentation amplifier · 1 circuit · 6 MHz · 1 nV/√Hz · >100 dB · ±25 V · 200 Ω · Current-feedback circuitry

Preis auf Anfrage

Datenblatt ansehen →

INA103KPG4 Grenzwerte & elektrische Eigenschaften

Product Type Low-noise, low-distortion instrumentation amplifier
Number of Circuits 1 circuit
Gehäuse 16-pin PDIP
Input Noise Density 1 nV/√Hz
Total Harmonic Distortion plus Noise 100
Gain-Bandwidth Product 1000 MHz
Supply Voltage Range ±25 V
Common-Mode Rejection Ratio >100 dB
Internal Gain-Setting Resistors 100 kΩ
Maximum Output Voltage ±10 V
Maximaler Ausgangsstrom 2.5 mA
Gain Accuracy 0.02%
Signal Input Type Differential
Montageart Through-hole

INA103KPG4 16-pin pdip Pinbelegungsleitfaden

Pinbelegung für INA103KPG4 (16-pin pdip-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.

Pinbelegungsdiagramm für INA103KPG4 im 16-pin pdip-Gehäuse

Keine detaillierten Pinbelegungsdaten verfügbar für INA103KPG4.

Siehe die Datenblatt für die vollständige Pin-Konfiguration.

Typische Anwendungen

INA103KPG4 ist geeignet für 6 Anwendungs: Bridge Transducer Signal Conditioning, Precision Current-Shunt Monitoring, Laboratory Instrumentation Front End, Industrial Pressure and Strain Measurement, Audio and Low-Level Signal Capture, Precision Current-Loop Receiver.

🏭

Bridge Transducer Signal Conditioning

The INA103KPG4 fits bridge-transducer interfaces that produce small differential voltages in the presence of a larger common-mode signal. Its input-noise density of 1 nV/√Hz limits the amplifier’s input-referred noise, while CMRR above 100 dB suppresses voltage shared by both bridge inputs. The built-in 100 kΩ gain-setting network also simplifies fixed-gain implementations. A practical design places the amplifier close to the bridge, uses shielded or differential routing where appropriate, and confirms that the selected gain keeps the output within ±10 V and 2.5 mA. The 1000 MHz gain-bandwidth product provides substantial headroom for fast settling, although usable bandwidth still depends on gain and source impedance.

⚡

Precision Current-Shunt Monitoring

For low-value shunt measurements, the INA103KPG4 amplifies the small differential voltage developed across the shunt while rejecting the supply or system common-mode voltage. The 1 nV/√Hz input-noise density is important when the shunt voltage approaches the measurement floor, and the greater-than-100-dB CMRR helps prevent supply movement from appearing at the output. Its differential architecture avoids requiring the shunt to sit near ground. Designers should minimize copper resistance between the sense nodes, use paired routing, and verify amplifier settling at the intended gain. The listed 0.02% gain accuracy contributes to overall current accuracy, while offset error must be included in the calibration budget.

🖥️

Laboratory Instrumentation Front End

The INA103KPG4 can serve as the low-noise front end of a laboratory measurement instrument that accepts differential sources. Its 1 nV/√Hz input-noise density supports high-resolution measurements, while CMRR above 100 dB reduces errors when the source shares a substantial voltage with the measurement system. The 1000 MHz gain-bandwidth product permits a broad range of source dynamics and fast transient response. Use the manufacturer’s gain table to select a configuration that preserves the required signal bandwidth and avoids output saturation. The internal gain-setting resistors reduce external component count, but output offset, bias current, and source-imbalance errors still require calibration for precision bench equipment.

🏭

Industrial Pressure and Strain Measurement

Pressure cells and strain gauges commonly produce low-level differential outputs with mechanical-system offsets and substantial common-mode voltage. The INA103KPG4 addresses those conditions through 1 nV/√Hz input noise, CMRR above 100 dB, and 0.02% listed gain accuracy. The device can amplify the sensor output close to the sensing element, before long cable runs or noisy stages add error. A robust implementation needs input transient protection appropriate to the industrial environment, clean grounding, and supply bypassing that prevents conducted noise from coupling into the measurement. Select the gain so the expected full-scale output remains below ±10 V, and account for the 2.5 mA output-current limit when driving the following stage.

🎧

Audio and Low-Level Signal Capture

The INA103KPG4 is appropriate for low-level differential audio or instrumentation signals where input noise and distortion determine the capture floor. Its 1 nV/√Hz input-noise density and listed THD+N value of 100 support high-fidelity signal conditioning, while the differential input rejects common-mode hum and ground differences that could affect a single-ended path. The 1000 MHz gain-bandwidth product gives ample bandwidth for audio-band signals and enables fast transient capture. The design should still use low-noise gain configuration, short balanced input routing, and carefully referenced grounding. The listed output-current limit is sufficient for typical downstream high-impedance stages but not for a low-impedance load, so buffer or attenuate such loads appropriately.

📡

Precision Current-Loop Receiver

A 4–20 mA current-loop receiver benefits from the INA103KPG4 because its differential input can reject voltage common to both ends of the loop, while its 1 nV/√Hz noise density supports accurate extraction of the loop current. The greater-than-100-dB CMRR is particularly useful where the measured current is referenced to a voltage that varies with the installation. Place the amplifier in the appropriate high-side or low-side topology, and ensure the input common-mode range remains valid for the complete loop voltage. Use the internal gain arrangement to establish the required transimpedance scaling while checking output swing against the ±10 V limit. External protection and filtering may be required for long cables and exposed industrial wiring.

What is the INA103KPG4?
The INA103KPG4 is a single-circuit, low-noise instrumentation amplifier from Texas Instruments. According to the manufacturer product page and component listing, it uses a 16-pin PDIP package and provides 1 nV/√Hz input noise, a 1000 MHz gain-bandwidth product, ±25 V supply capability, and CMRR above 100 dB. It is intended for precision differential-signal conditioning where low noise and common-mode rejection are more important than a minimal amplifier footprint.
What is the noise performance of INA103KPG4?
The INA103KPG4 has an input-noise density of 1 nV/√Hz, which makes it suitable for low-level differential measurements. The manufacturer describes the device as a low-noise, low-distortion instrumentation amplifier and states that it upgrades the AD625. Noise performance is particularly important when amplifying weak bridge, shunt, or sensor outputs because input-referred noise limits the smallest signal that can be resolved reliably.
What is the gain-bandwidth product of INA103KPG4?
The INA103KPG4 has a listed gain-bandwidth product of 1000 MHz. This is the product of closed-loop gain and usable bandwidth, so the corresponding bandwidth changes with the selected gain. The value indicates high signal-path speed, but engineers should still evaluate source impedance, internal gain resistors, output loading, and settling behavior before treating the full bandwidth as usable in every gain configuration.
Why is the INA103KPG4 suitable for differential sensors?
The INA103KPG4 is suitable for differential sensors because it combines 1 nV/√Hz input noise with common-mode rejection greater than 100 dB. This allows the wanted difference between two sensor terminals to be amplified while rejecting much of the voltage shared by both inputs. The result is particularly useful for bridge transducers, shunt monitors, and current-loop receivers operating with appreciable common-mode voltage.
Does INA103KPG4 have internal gain-setting resistors?
Yes, the INA103KPG4 includes built-in gain-setting resistors specified as 100 kΩ. These internal resistors simplify fixed-gain instrumentation-amplifier circuits compared with a design requiring a complete external resistor network. Because their value and tolerance establish gain accuracy, designers should consult the gain table and pin description in the manufacturer datasheet when assigning a fixed gain configuration.
What supply voltage does INA103KPG4 use?
The INA103KPG4 supports a wide supply range extending to ±25 V, covering both positive and negative supply operation in the listed specifications. The exact allowable single-supply configuration, common-mode input range, and output-swing limits must be checked against the operating condition and gain in the manufacturer datasheet. Supply polarity and the input/output voltage limits are important because instrumentation-amplifier performance is constrained by internal amplifier saturation.
How accurate is the INA103KPG4 gain?
The listed gain accuracy for INA103KPG4 is 0.02%. This specification is relevant to precision measurement systems because gain error directly scales the measured signal and therefore affects overall instrument accuracy. Input-offset error and source-imbalance effects should also be included in the system error budget. The 100 kΩ internal gain-setting resistors and the selected fixed-gain configuration determine how that accuracy is realized in operation.
Where can I download the INA103KPG4 datasheet PDF?
The official INA103 documentation is available through the Texas Instruments INA103 product page at https://www.ti.com/product/INA103. From that page, engineers can access the manufacturer datasheet, ordering information, parameters, and support documents. The manufacturer data should be the controlling reference for the complete pinout, electrical characteristics, gain configurations, package dimensions, and recommended application circuit.
Where can I find the INA103KPG4 pinout?
The INA103KPG4 pinout is documented in the pin-configuration section of the Texas Instruments INA103 datasheet. The component listing identifies the device as a 16-pin PDIP, and engineers should assign signals using the numbered package drawing and pin-description table. The exposed-pad package diagram is not applicable because this part uses a through-hole PDIP rather than a surface-mount package.
Can INA103KP replace INA103KPG4?
INA103KP is the closest same-family candidate identified for INA103KPG4 because the parts are compared directly by Texas Instruments and appear together in cross-reference results. It uses the same INA103 family identity and the listed INA103KPG4 package is a 16-pin PDIP. Before treating it as an exact replacement, confirm the ordering codes, pin functions, lead finish, temperature grade, gain configuration, and lifecycle status for the exact supplier lot.
What is the best drop-in replacement for INA103KPG4?
INA103KP is the best-supported drop-in candidate shown for INA103KPG4, with a parameter and package match close to 100% based on the shared INA103 family identity and 16-pin PDIP format. No other same-footprint alternative is confirmed strongly enough to recommend without direct pin and specification verification. Use the Request a Quote form on this page when exact replacement sourcing, traceability, or current availability is required.
INA103KPG4 vs INA103KP: which one should I choose?
Choose INA103KPG4 when its exact ordering code is required for procurement, qualification, or traceability; choose INA103KP when it is an approved equivalent for the target assembly. The two parts are directly compared as INA103-family devices, but ordering suffixes can encode qualification, temperature, packaging, or manufacturing distinctions. Verify the complete ordering table, grade, and package dimensions before making a substitution.
When should I choose INA103KPG4 instead of a general-purpose amplifier?
Choose INA103KPG4 when the source is differential, low-level, and exposed to significant common-mode voltage. Its 1 nV/√Hz noise density, CMRR above 100 dB, and 0.02% listed gain accuracy address instrumentation requirements that ordinary single-ended amplifiers may not satisfy. A general-purpose amplifier can be appropriate when the signal is single-ended, common-mode rejection is unimportant, and lower analog complexity is sufficient.
Is INA103KPG4 suitable for industrial sensor conditioning?
Yes, INA103KPG4 is well suited to low-level industrial sensor conditioning because it combines differential input, low noise, high CMRR, internal gain resistors, and a 1000 MHz gain-bandwidth product. In an industrial bridge or shunt interface, these characteristics help preserve small sensor signals in the presence of common-mode disturbances. The circuit still requires suitable protection, grounding, supply filtering, and compliance with the equipment’s environmental requirements.
Where to buy INA103KPG4 online, and what are its price and lead time?
Use the Request a Quote form on this page for current INA103KPG4 price, stock, minimum order quantity, and lead time. The request identifies the exact Texas Instruments part number, 16-pin PDIP package, and required quantity so that the supply response reflects the correct ordering variant. Quote terms and availability can change, making a direct request more reliable than a static listing value.

Technische Referenzdaten für INA103KPG4 – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose INA103KPG4 when the exact 16-pin PDIP ordering code is required for an existing design, qualification record, or controlled BOM. Its 1 nV/√Hz input noise, 1000 MHz gain-bandwidth product, CMRR above 100 dB, internal 100 kΩ gain-setting resistors, and 0.02% listed gain accuracy suit low-level differential sensor, shunt, laboratory, and current-loop measurements. INA103KP is the closest supported replacement candidate because it belongs to the same INA103 family and is directly compared with the target. Review ordering-suffix, qualification, temperature-grade, lifecycle, and traceability requirements before substitution. No other cross-brand part can be recommended as a true drop-in replacement from the available documentation because same-package pin compatibility and complete parametric equivalence are not established. If the PCB uses a surface-mount footprint or requires a different gain architecture, changing the amplifier is not a drop-in operation and the layout must be redesigned.

Vergleich mit Alternativen

Parameter Dieses Produkt INA103KP
Package 16-pin PDIP 16-pin PDIP
Brand Texas Instruments Texas Instruments
Product Type Low-noise, low-distortion instrumentation amplifier INA103-family instrumentation amplifier
Input Noise Density 1 nV/√Hz 1 nV/√Hz
Gain-Bandwidth Product 1000 MHz 1000 MHz
Supply Voltage Range ±25 V ±25 V
Common-Mode Rejection Ratio >100 dB >100 dB
Internal Gain-Setting Resistors 100 kΩ 100 kΩ
Maximum Output Voltage ±10 V ±10 V
Maximum Output Current 2.5 mA 2.5 mA
Gain Accuracy 0.02% 0.02%
Total Harmonic Distortion plus Noise 100 100

Wichtigste Unterscheidungsmerkmale

  • Very low input-noise density for instrumentation (vs. INA103KP)
  • High gain-bandwidth product for fast differential signals (vs. INA103KP)
  • Strong common-mode rejection (vs. INA103KP)

Designhinweise

Route the two differential inputs as a matched pair and keep them short, away from switching nodes and high-current paths. Source-imbalance resistance converts input bias current into differential offset, so adding substantial resistance to only one input can degrade accuracy. Place the INA103KPG4 near the sensor or shunt, use a solid ground reference, and evaluate the complete input network against the manufacturer’s input-bias-current and noise specifications.

Provide local supply bypassing at the amplifier pins and keep return-current paths short so supply noise and ground bounce do not enter the signal path. The device supports supply operation extending to ±25 V, but the chosen operating condition must also satisfy the input common-mode range and output-swing limits. Decouple any noisy upstream converter and confirm that the output stage remains within its listed ±10 V voltage and 2.5 mA current limits.

Do not select gain solely from the 1000 MHz gain-bandwidth product. Higher gain reduces the bandwidth available for settling, and real-world performance also depends on source impedance, internal 100 kΩ gain resistors, output loading, and frequency-dependent distortion. Use the manufacturer gain table and timing data to verify settling before the next conversion or acquisition step. Include offset, gain, and common-mode errors in the system calibration budget.

Compliance-Informationen

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Bleifrei
Unknown
Halogenfrei
Unknown
Konfliktmineralien
Unknown

The manufacturer product page and component listings do not provide explicit compliance conclusions for this ordering code in the cited content. INA103KPG4 is an instrumentation amplifier rather than an automotive-qualified ordering variant.

Daten verifiziert am: 2026-11-19 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

INA103KPG4 datasheet INA103KPG4 pinout INA103KPG4 datasheet pdf INA103KPG4 equivalent INA103KPG4 replacement INA103KPG4 cross reference INA103KPG4 vs INA103KP INA103KPG4 price INA103KPG4 stock Texas Instruments INA103KPG4 INA103KPG4 instrumentation amplifier INA103KPG4 16-PDIP INA103KPG4 sensor amplifier INA103KPG4 low noise amplifier

Verwandte Bauteile & Begriffe

Texas Instruments INA103KPG4 INA103KP INA114APG4 INA849 instrumentation amplifier precision amplifier low-noise amplifier low-distortion amplifier differential amplifier analog integrated circuit semiconductor 1 nV/√Hz input noise 1000 MHz gain-bandwidth product common-mode rejection ratio CMRR 100 kΩ gain-setting resistor 16-pin PDIP through-hole package sensor signal conditioning bridge transducer current-shunt measurement precision current-loop receiver AD625
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen