INA103KPG4 - Sensor Signal Amplifier | Texas Instruments
MPN: INA103KPG4 ✓ פעילINA103KPG4 סקירה
An instrumentation amplifier is a specialized analog amplifier that amplifies the difference between two input signals while rejecting voltage common to both inputs. In the signal-chain hierarchy, the INA103 belongs to instrumentation amplifiers, a precision-oriented subclass of amplifiers and analog integrated circuits. Its differential architecture supports sensor interfaces, current-loop receivers, and measurement systems in which ground offsets or other common-mode voltages could otherwise overwhelm the wanted signal.
Key features include an input-noise density of 1 nV/√Hz, a gain-bandwidth product of 1000 MHz, and CMRR above 100 dB. The listed THD+N specification is 100, indicating low distortion in precision signal chains. Internal gain-setting resistors are specified as 100 kΩ, while the device supports output voltages up to ±10 V and output current up to 2.5 mA. These characteristics favor applications requiring high bandwidth and low-noise amplification rather than only basic differential gain.
The INA103 is also identified as an upgrade to the AD625 and uses built-in gain-setting resistors. Such internal networks simplify instrumentation-amplifier implementation by reducing the number of external precision resistors required for fixed-gain configurations. Designers still need to observe the complete electrical limits, package thermal constraints, output-current capability, and application-specific settling requirements when assigning gain and bandwidth.
Typical uses include bridge-transducer interfaces, precision current-shunt measurements, industrial sensor conditioning, laboratory instrumentation, and low-level differential-signal acquisition. The 1 nV/√Hz noise density is particularly relevant when the sensor output is small, while CMRR above 100 dB helps preserve that output when common-mode voltage changes are present.
A key design consideration is that high gain-bandwidth product does not guarantee useful signal bandwidth at every gain setting. Input and output impedances, internal gain resistors, source impedance, and the selected gain must be evaluated together. Decoupling should follow the manufacturer’s recommended supply and layout practices to prevent supply noise or instability from degrading measured performance.
This page combines manufacturer specifications, package information, verified component listings, drop-in replacement assessment, comparison parameters, and practical application guidance to support faster instrumentation-amplifier selection and PCB design.
חלופות תחליף ישיר עבור INA103KPG4 — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם INA103KPG4 (אותו גורם צורה וטביעת רגל) — שונים ב Gain-Bandwidth Product.
INA103KP
✅ Drop-Inצור קשר לקבלת מחיר
הצג גיליון נתונים ←INA103KPG4 דירוגים מרביים ומאפיינים חשמליים
| Product Type | Low-noise, low-distortion instrumentation amplifier |
| Number of Circuits | 1 circuit |
| מארז | 16-pin PDIP |
| Input Noise Density | 1 nV/√Hz |
| Total Harmonic Distortion plus Noise | 100 |
| Gain-Bandwidth Product | 1000 MHz |
| Supply Voltage Range | ±25 V |
| Common-Mode Rejection Ratio | >100 dB |
| Internal Gain-Setting Resistors | 100 kΩ |
| Maximum Output Voltage | ±10 V |
| זרם מוצא מקסימלי | 2.5 mA |
| Gain Accuracy | 0.02% |
| Signal Input Type | Differential |
| סוג הרכבה | Through-hole |
מדריך תצורת פינים של INA103KPG4 16-pin pdip
תצורת פינים עבור INA103KPG4 (מארזת 16-pin pdip). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.
אין נתוני פריסת פינים מפורטים עבור INA103KPG4.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
INA103KPG4 מתאים עבור 6 יישוםs: Bridge Transducer Signal Conditioning, Precision Current-Shunt Monitoring, Laboratory Instrumentation Front End, Industrial Pressure and Strain Measurement, Audio and Low-Level Signal Capture, Precision Current-Loop Receiver.
Bridge Transducer Signal Conditioning
The INA103KPG4 fits bridge-transducer interfaces that produce small differential voltages in the presence of a larger common-mode signal. Its input-noise density of 1 nV/√Hz limits the amplifier’s input-referred noise, while CMRR above 100 dB suppresses voltage shared by both bridge inputs. The built-in 100 kΩ gain-setting network also simplifies fixed-gain implementations. A practical design places the amplifier close to the bridge, uses shielded or differential routing where appropriate, and confirms that the selected gain keeps the output within ±10 V and 2.5 mA. The 1000 MHz gain-bandwidth product provides substantial headroom for fast settling, although usable bandwidth still depends on gain and source impedance.
מומלץ
Precision Current-Shunt Monitoring
For low-value shunt measurements, the INA103KPG4 amplifies the small differential voltage developed across the shunt while rejecting the supply or system common-mode voltage. The 1 nV/√Hz input-noise density is important when the shunt voltage approaches the measurement floor, and the greater-than-100-dB CMRR helps prevent supply movement from appearing at the output. Its differential architecture avoids requiring the shunt to sit near ground. Designers should minimize copper resistance between the sense nodes, use paired routing, and verify amplifier settling at the intended gain. The listed 0.02% gain accuracy contributes to overall current accuracy, while offset error must be included in the calibration budget.
מומלץ
Laboratory Instrumentation Front End
The INA103KPG4 can serve as the low-noise front end of a laboratory measurement instrument that accepts differential sources. Its 1 nV/√Hz input-noise density supports high-resolution measurements, while CMRR above 100 dB reduces errors when the source shares a substantial voltage with the measurement system. The 1000 MHz gain-bandwidth product permits a broad range of source dynamics and fast transient response. Use the manufacturer’s gain table to select a configuration that preserves the required signal bandwidth and avoids output saturation. The internal gain-setting resistors reduce external component count, but output offset, bias current, and source-imbalance errors still require calibration for precision bench equipment.
מומלץ
Industrial Pressure and Strain Measurement
Pressure cells and strain gauges commonly produce low-level differential outputs with mechanical-system offsets and substantial common-mode voltage. The INA103KPG4 addresses those conditions through 1 nV/√Hz input noise, CMRR above 100 dB, and 0.02% listed gain accuracy. The device can amplify the sensor output close to the sensing element, before long cable runs or noisy stages add error. A robust implementation needs input transient protection appropriate to the industrial environment, clean grounding, and supply bypassing that prevents conducted noise from coupling into the measurement. Select the gain so the expected full-scale output remains below ±10 V, and account for the 2.5 mA output-current limit when driving the following stage.
מומלץ
Audio and Low-Level Signal Capture
The INA103KPG4 is appropriate for low-level differential audio or instrumentation signals where input noise and distortion determine the capture floor. Its 1 nV/√Hz input-noise density and listed THD+N value of 100 support high-fidelity signal conditioning, while the differential input rejects common-mode hum and ground differences that could affect a single-ended path. The 1000 MHz gain-bandwidth product gives ample bandwidth for audio-band signals and enables fast transient capture. The design should still use low-noise gain configuration, short balanced input routing, and carefully referenced grounding. The listed output-current limit is sufficient for typical downstream high-impedance stages but not for a low-impedance load, so buffer or attenuate such loads appropriately.
מומלץ
Precision Current-Loop Receiver
A 4–20 mA current-loop receiver benefits from the INA103KPG4 because its differential input can reject voltage common to both ends of the loop, while its 1 nV/√Hz noise density supports accurate extraction of the loop current. The greater-than-100-dB CMRR is particularly useful where the measured current is referenced to a voltage that varies with the installation. Place the amplifier in the appropriate high-side or low-side topology, and ensure the input common-mode range remains valid for the complete loop voltage. Use the internal gain arrangement to establish the required transimpedance scaling while checking output swing against the ±10 V limit. External protection and filtering may be required for long cables and exposed industrial wiring.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור INA103KPG4 — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | INA103KP |
|---|---|---|
| Package | 16-pin PDIP | 16-pin PDIP |
| Brand | Texas Instruments | Texas Instruments |
| Product Type | Low-noise, low-distortion instrumentation amplifier | INA103-family instrumentation amplifier |
| Input Noise Density | 1 nV/√Hz | 1 nV/√Hz |
| Gain-Bandwidth Product | 1000 MHz | 1000 MHz |
| Supply Voltage Range | ±25 V | ±25 V |
| Common-Mode Rejection Ratio | >100 dB | >100 dB |
| Internal Gain-Setting Resistors | 100 kΩ | 100 kΩ |
| Maximum Output Voltage | ±10 V | ±10 V |
| Maximum Output Current | 2.5 mA | 2.5 mA |
| Gain Accuracy | 0.02% | 0.02% |
| Total Harmonic Distortion plus Noise | 100 | 100 |
מבדילים עיקריים
- Very low input-noise density for instrumentation (לעומתINA103KP)
- High gain-bandwidth product for fast differential signals (לעומתINA103KP)
- Strong common-mode rejection (לעומתINA103KP)
הערות תכנון
Route the two differential inputs as a matched pair and keep them short, away from switching nodes and high-current paths. Source-imbalance resistance converts input bias current into differential offset, so adding substantial resistance to only one input can degrade accuracy. Place the INA103KPG4 near the sensor or shunt, use a solid ground reference, and evaluate the complete input network against the manufacturer’s input-bias-current and noise specifications.
Provide local supply bypassing at the amplifier pins and keep return-current paths short so supply noise and ground bounce do not enter the signal path. The device supports supply operation extending to ±25 V, but the chosen operating condition must also satisfy the input common-mode range and output-swing limits. Decouple any noisy upstream converter and confirm that the output stage remains within its listed ±10 V voltage and 2.5 mA current limits.
Do not select gain solely from the 1000 MHz gain-bandwidth product. Higher gain reduces the bandwidth available for settling, and real-world performance also depends on source impedance, internal 100 kΩ gain resistors, output loading, and frequency-dependent distortion. Use the manufacturer gain table and timing data to verify settling before the next conversion or acquisition step. Include offset, gain, and common-mode errors in the system calibration budget.
מידע על תאימות
The manufacturer product page and component listings do not provide explicit compliance conclusions for this ordering code in the cited content. INA103KPG4 is an instrumentation amplifier rather than an automotive-qualified ordering variant.