Texas Instruments

INA111AU/1K - High-Speed FET Instrumentation Amplifier | TI

Teilenummer: INA111AU/1K ✓ Aktiv
500 uV maximum Vdss 20 pA maximum Id 16-pin SOIC (DW) Package
MOQ: 1 |

INA111AU/1K Übersicht

The Texas Instruments INA111AU/1K is a high-speed, FET-input instrumentation amplifier in a 16-pin SOIC package. It provides a 2 MHz bandwidth at a gain of 10, settles to within 0.01% in 4 microseconds at a gain of 100, and accepts input bias current below 20 pA. A single external resistor sets the gain from 1 to more than 1000, making the device suitable for precision sensor interfaces and low-level differential measurements.

An instrumentation amplifier is a differential analog amplifier optimized for measuring small signals superimposed on a larger common-mode voltage. Its internal architecture provides high input impedance, accurate differential gain, and strong common-mode rejection without requiring the user to match closely coupled input resistors. The INA111 belongs to the amplifier hierarchy as a FET-input instrumentation amplifier, a precision analog IC, and ultimately a signal-conditioning semiconductor used between sensors and data-conversion or control systems.

Key electrical features include input bias current below 20 pA, maximum input offset voltage of 500 microvolts, maximum offset drift of 5 microvolts per degree Celsius, and common-mode rejection of at least 106 dB. The low input current simplifies filtering for high-impedance sensors, while the high CMRR suppresses common-mode interference. The current-feedback architecture supports extended bandwidth and rapid settling, which helps preserve accuracy when gain changes occur in measurement systems.

The device uses one external gain-setting resistor, allowing designers to select gain without a resistor network. Because the achievable bandwidth depends on gain, the INA111 is especially useful where measurement speed must be balanced against signal amplification. Its offset and drift characteristics also make it suitable for bridge transducers, biomedical instrumentation, and industrial data-acquisition systems operating across the manufacturer-specified temperature range of -40°C to +85°C.

Typical uses include medical instrumentation, industrial data acquisition, precision bridge-sensor interfaces, current measurement, and low-level differential signal conditioning. In these applications, the amplifier can sit between a sensor and an ADC while rejecting common-mode voltage present on both sensor lines. The design should preserve the common-mode voltage within the device's operating limits and provide appropriate filtering at the inputs.

For PCB implementation, place the gain resistor close to the gain-setting pins, maintain short and symmetric input traces, and decouple the supply pins near the device. Input filtering components should have closely matched impedances if their tolerance could unbalance the differential signal. Because the offset specification is referenced to a particular gain, recalculate accuracy when the external gain resistor differs from the manufacturer's test condition.

This product page combines the manufacturer's electrical and package information with practical design guidance, pin and footprint considerations, application fit, and drop-in replacement analysis for engineers evaluating the INA111AU/1K in new and existing analog signal-chain designs.

Drop-in-Alternativen für INA111AU/1K – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit INA111AU/1K (gleiche Bauform und Footprint) – abweichend in Input Bias Current, Input Offset Voltage, Input Offset Voltage Drift, Operating Temperature Range, Package.

Texas Instruments
Input Bias Current: 5 nA maximum
Input Offset Voltage: 50 µV maximum
Input Offset Voltage Drift: 0.5 µV/°C maximum

INA114BU/1K

✅ Drop-In
📦 16-pin SOIC (DW)
Same 16-pin SOIC format; gain, bandwidth, offset and noise differ, with exact deltas listed in the manufacturer comparison data where available.

📋 Referenzalternative (nicht im Katalog)

INA129UA

✅ Drop-In
Texas Instruments
📦 16-pin SOIC (DW)
Precision instrumentation amplifier · 1 circuit · 50 µV maximum · 0.5 µV/°C maximum · 5 nA maximum · 120 dB minimum · ±40 V · ±18 V maximum

Preis auf Anfrage

Datenblatt ansehen →

AD825AR-16-REEL7

✅ Drop-In
📦 16-pin SOIC (DW)
Same 16-pin SOIC format; gain, bandwidth, offset and noise differ, with exact deltas listed in the manufacturer comparison data where available.

📋 Referenzalternative (nicht im Katalog)

INA111AU/1K Grenzwerte & elektrische Eigenschaften

Product Type High-speed FET-input instrumentation amplifier
Number of Circuits 1 circuit
Bandwidth at Gain 10 2 MHz
Settling Time at Gain 100 4 us to 0.01%
Gain Range 1 to over 1000
Gain Configuration One external resistor
Input Bias Current 20 pA maximum
Input Offset Voltage 500 uV maximum
Input Offset Voltage Drift 5 uV/°C maximum
Common-Mode Rejection 106 dB minimum
Architecture Current feedback
Betriebstemperaturbereich -40°C to +85°C
Gehäuse 16-pin SOIC (DW)
Montageart Surface mount
RoHS-Status Compliant
REACH Status Compliant
Automotive Qualification Not applicable
Primary Applications Medical instrumentation and data acquisition

INA111AU/1K 16-pin soic (dw) Pinbelegungsleitfaden

Pinbelegung für INA111AU/1K (16-pin soic (dw)-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.

Pinbelegungsdiagramm für INA111AU/1K im 16-pin soic (dw)-Gehäuse

Keine detaillierten Pinbelegungsdaten verfügbar für INA111AU/1K.

Siehe die Datenblatt für die vollständige Pin-Konfiguration.

Typische Anwendungen

INA111AU/1K ist geeignet für 6 Anwendungs: Medical Instrumentation, Industrial Data Acquisition, Precision Bridge Sensor Interface, Current Measurement, Instrumentation Signal Conditioning, Low-Level Differential Sensor Interface.

💊

Medical Instrumentation

The Texas Instruments INA111AU/1K fits low-level biomedical front ends that must separate a small differential sensor signal from a substantial common-mode voltage. Its input bias current below 20 pA minimizes disturbance at high-impedance sources, while the common-mode rejection of at least 106 dB helps suppress physiological and environmental interference. The current-feedback architecture provides 2 MHz bandwidth at gain 10 and 4 us settling to 0.01% at gain 100, which is useful when acquisition timing matters. Offset error still requires attention because the maximum input offset voltage is 500 uV and drift reaches 5 uV/°C. A calibrated frontend should account for those values and apply input protection appropriate to the sensor and patient-protection circuit.

🏭

Industrial Data Acquisition

The INA111AU/1K is appropriate for industrial data-acquisition modules conditioning small differential inputs from multiple analog sensors. Its 106 dB minimum common-mode rejection improves signal integrity when sensor outputs sit on a noisy common-mode reference, and the single-resistor gain setting simplifies configuration across different measurement ranges. The 2 MHz bandwidth at gain 10 allows faster sampling than a slow precision-only amplifier, while 4 us settling at gain 100 supports repeated channel acquisition. Designers should maintain balanced input routing, use a quiet ground reference, and verify that the sensor excitation and common-mode range remain compatible with the amplifier's operating limits.

⚡

Precision Bridge Sensor Interface

The INA111AU/1K can amplify the differential output of resistive bridge transducers while rejecting the excitation voltage appearing equally on both inputs. Its FET-input bias current below 20 pA reduces errors when the bridge and protection network have high source impedance, and the current-feedback topology provides useful speed at moderate gain. One external resistor sets the gain from 1 to over 1000, allowing the same device to cover different transducer sensitivities. Because bridge outputs can be small, use the 500 uV maximum offset and 5 uV/°C maximum drift in the error budget, provide stable excitation, and place the gain resistor close to the device.

⚡

Current Measurement

The INA111AU/1K is suitable for measuring small differential voltages across a low-value shunt or current-sense element. Its high common-mode rejection helps when the shunt voltage is superimposed on a larger supply rail, and the 2 MHz bandwidth at gain 10 provides a useful response for current-loop and power-control signals. Input bias current below 20 pA avoids introducing significant error in high-impedance shunt arrangements. The amplifier's input and common-mode limits must remain within the shunt operating envelope, and Kelvin routing should carry the sense-pair signals together to minimize parasitic voltage. Gain resistor placement and input filtering should avoid creating additional unmatched impedance at the sensitive inputs.

🔧

Instrumentation Signal Conditioning

The INA111AU/1K provides a compact differential-to-single-ended conditioning stage for laboratory and test equipment. Engineers can select gain with one resistor, retain a 2 MHz bandwidth at gain 10, and use the 106 dB minimum common-mode rejection to improve signals measured in the presence of shared reference voltage. The device is particularly useful when the system needs faster settling than precision-only instrumentation amplifiers provide: the specified settling time is 4 us to 0.01% at gain 100. Keep analog traces short, provide local supply bypassing, and treat the output-reference connection as a sensitive analog node to preserve measurement accuracy.

📱

Low-Level Differential Sensor Interface

The INA111AU/1K can condition outputs from low-level differential sensors where source current must be minimized and common-mode interference must be rejected. Input bias current below 20 pA helps preserve sensor accuracy, while the 500 uV maximum offset and 5 uV/°C maximum drift establish the principal static-error limits. The single external gain resistor simplifies gain selection, and the 2 MHz bandwidth at gain 10 supports faster signal changes than a low-bandwidth precision amplifier. For reliable operation, verify the common-mode range, use matched input-filter impedances, keep the gain network compact, and provide a low-impedance ground reference. Calibration may be necessary when offset and drift dominate the measurement.

Zusammenfassung der empfohlenen Produkte

INA114BU/1K Same-manufacturer precision instrumentation amplifier alternative Verwendet in: Medical Instrumentation, Industrial Data Acquisition, Precision Bridge Sensor Interface, Current Measurement, Instrumentation Signal Conditioning, Low-Level Differential Sensor Interface INA129UA Texas Instruments Verwendet in: Medical Instrumentation, Precision Bridge Sensor Interface, Current Measurement, Low-Level Differential Sensor Interface ADS1220 Texas Instruments Verwendet in: Industrial Data Acquisition AD825AR-16-REEL7 Cross-brand 16-pin instrumentation amplifier candidate Verwendet in: Instrumentation Signal Conditioning
What is the INA111AU/1K?
The INA111AU/1K is a single-circuit, high-speed FET-input instrumentation amplifier from Texas Instruments. According to the manufacturer product page, it is packaged in a 16-pin SOIC and operates from -40°C to +85°C. It reaches 2 MHz bandwidth at gain 10 and uses one external resistor for gains from 1 to more than 1000.
What are the key specifications of INA111AU/1K that engineers should know?
The INA111AU/1K combines a 2 MHz bandwidth at gain 10, 4 us settling to 0.01% at gain 100, and input bias current below 20 pA. The Texas Instruments product information also specifies maximum input offset voltage of 500 uV, maximum offset drift of 5 uV/°C, and minimum common-mode rejection of 106 dB. These characteristics make the amplifier suitable for low-level differential signals and high-impedance sensors.
Where can I download the INA111AU/1K datasheet PDF?
The official INA111AU/1K datasheet and product resources are available from Texas Instruments through the manufacturer's part-details page at https://www.ti.com/product/INA111/part-details/INA111AU/1K. The manufacturer identifies the device as a 16-pin SOIC instrumentation amplifier rated for -40°C to +85°C. Use the pin-description and electrical-characteristics tables in that document when assigning PCB tracks and calculating system accuracy.
Where can I find the INA111AU/1K pinout?
The INA111AU/1K pinout is published in the manufacturer datasheet for the 16-pin SOIC package. Use the pin-description table for exact pin numbering, including the gain-setting resistor connection, input terminals, reference, supply, output, and any no-connect positions. The package library key for this product is soic-16, corresponding to all 16 physical pins.
How is the gain set on an INA111AU/1K?
The INA111AU/1K sets its differential gain with one external resistor. The manufacturer states that a single resistor provides gains from 1 to more than 1000. Because the current-feedback amplifier's bandwidth changes with gain, select the resistor using both the required signal gain and the desired response speed rather than considering gain alone.
What can replace the INA111AU/1K?
The closest documented replacements include the Texas Instruments INA114BU/1K, the INA129UA, and the Analog Devices AD825AR-16-REEL7, but each requires careful pin and parameter verification before substitution. The INA114BU/1K stays within the same TI 16-pin SOIC family, while the INA129UA and AD825AR-16-REEL7 are cross-brand candidates identified by comparison resources. Use the Request a Quote form for current availability and an engineering review of gain, bandwidth, offset, and pin functions.
What is the best Analog Devices equivalent for INA111AU/1K?
The AD825AR-16-REEL7 is the identified Analog Devices cross-brand candidate for the INA111AU/1K, with both devices using a 16-pin SOIC format. The cross-reference identifies it as an equivalent, but a true drop-in substitution still requires confirmation of pin functions, external gain-resistor topology, supply range, offset, bandwidth, and settling behavior. Do not substitute it solely on package count.
INA111AU/1K vs INA114BU/1K - which is better for bridge sensors?
The INA114BU/1K is the more logical choice for bridge-sensor designs when its manufacturer-specified input characteristics and noise performance better match the transducer. The INA111AU/1K is preferable when its documented 2 MHz bandwidth at gain 10 and 4 us settling at gain 100 are more important. Both are TI 16-pin SOIC devices, so confirm their individual pin functions and gain-setting networks before replacement.
INA111AU/1K vs INA129UA - what is the difference?
The INA111AU/1K is a current-feedback, FET-input instrumentation amplifier with 2 MHz bandwidth at gain 10 and input bias current below 20 pA. The INA129UA is a precision instrumentation amplifier that should be compared against the required gain range, offset, noise, supply voltage, and settling-time limits. Both use 16-pin SOIC packages, but equal pin count does not by itself guarantee electrical or pin-to-pin compatibility.
When should I choose INA111AU/1K over a lower-bandwidth instrumentation amplifier?
Choose the INA111AU/1K when the measurement path requires more than the bandwidth of a precision-oriented low-noise amplifier. Its 2 MHz bandwidth at gain 10 and 4 us settling to 0.01% at gain 100 support faster sensor acquisition and signal-chain transitions. The trade-off is that speed-focused instrumentation amplifiers can differ from low-noise designs in offset and noise behavior.
Is INA111AU/1K suitable for high-impedance sensors?
The INA111AU/1K is suitable for high-impedance sensors because its FET inputs reduce bias current to below 20 pA. Low input current limits the voltage error introduced by source impedance and simplifies input-filter design. The common-mode voltage, input voltage, and supply limits must still be checked against the manufacturer's operating ranges before connecting the sensor.
Does INA111AU/1K need an external gain resistor?
The INA111AU/1K uses an external resistor to establish differential gain, and the manufacturer states that one resistor supports gains from 1 to over 1000. Place the resistor close to the gain-setting pins to minimize parasitic capacitance and board noise. Its resistance should follow the manufacturer's gain equation and account for the bandwidth change at higher gains.
Where can I buy INA111AU/1K online?
Use the Request a Quote form on this page to request the INA111AU/1K by exact manufacturer part number. Confirm that the requested configuration is the 16-pin SOIC INA111AU/1K rather than a different package or grade. The form is the appropriate channel for current stock status, minimum order quantity, lead time, and a formal quotation.
What is the price of INA111AU/1K?
Current pricing for INA111AU/1K is obtained through the Request a Quote form on this page rather than through a static price statement. Submit the exact MPN, required quantity, and delivery destination to receive current commercial terms. This avoids ambiguity between the 16-pin SOIC device, other INA111 package variants, and different order quantities.
What is the lead time and stock status for INA111AU/1K?
Request the current lead time and stock status for INA111AU/1K through the Request a Quote form on this page. Include the required quantity, reel format, and destination so the supplier can confirm the exact 16-pin SOIC configuration. The Texas Instruments product page identifies INA111AU/1K as a high-speed FET-input instrumentation amplifier, but orderable quantity and delivery timing should be confirmed through the quotation channel.

Technische Referenzdaten für INA111AU/1K – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the INA111AU/1K when the signal chain needs a combination of very low input bias current, high common-mode rejection, and moderate-gain speed. Its input bias current below 20 pA supports high-impedance sources, while 2 MHz bandwidth at gain 10 and 4 us settling at gain 100 make it useful in faster data-acquisition paths. Select the INA114BU/1K when its precision characteristics better match a bridge or low-level sensor, and review the INA129UA when lower offset or different gain behavior is preferable. Consider the AD825AR-16-REEL7 for a cross-brand 16-pin SOIC sourcing option, but verify its exact pinout and specifications. In every case, calculate gain-resistor value, bandwidth, offset, drift, input range, and common-mode headroom before approving a substitution.

Vergleich mit Alternativen

Parameter Dieses Produkt INA114BU/1K INA129UA AD825AR-16-REEL7
Brand Texas Instruments Texas Instruments Texas Instruments Analog Devices
Package 16-pin SOIC (DW) 16-pin SOIC (DW) 16-pin SOIC (DW) 16-pin SOIC
Product Type FET-input instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier
Gain Setting One external resistor; gain 1 to over 1000 External resistor gain setting External resistor gain setting External resistor gain setting

Wichtigste Unterscheidungsmerkmale

  • High-speed bandwidth at moderate gain (vs. INA114BU/1K)
  • Fast specified settling at gain 100 (vs. INA129UA)
  • Cross-brand candidate with the same 16-pin SOIC format (vs. AD825AR-16-REEL7)

Designhinweise

Place the external gain-setting resistor close to the INA111AU/1K gain pins, and keep the two input paths short and geometrically similar. Differential signals should arrive through matched routing so that parasitic capacitance and resistance do not unbalance the inputs. Keep the output and reference traces away from switching nodes and high-current return paths. The 2 MHz bandwidth at gain 10 makes clean physical routing particularly important.

Use the manufacturer gain equation to select the external resistor, then verify the resulting bandwidth at the operating gain. The INA111AU/1K reaches 2 MHz at gain 10 but provides 4 us settling to 0.01% at gain 100, so bandwidth and acquisition time should both be included in the design. Place any input-filter capacitors close to the device and use matched components to avoid converting common-mode interference into differential error.

Do not assume that every 16-pin SOIC instrumentation amplifier is interchangeable. Before substituting INA114BU/1K, INA129UA, or AD825AR-16-REEL7, compare pin functions, supply limits, input common-mode range, gain-resistor calculation, offset, drift, bandwidth, and settling behavior. The INA111AU/1K has a 500 uV maximum offset and 5 uV/°C maximum drift, so a replacement can change the complete system error budget even when the package matches.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Unknown
Halogenfrei
Unknown
Konfliktmineralien
Unknown

RoHS and REACH compliance are identified in the Abacus Technologies product catalog. Lead-free, halogen-free, and conflict-minerals status are unknown.

Ähnliche Suchanfragen

ina111au datasheet INA111AU/1K datasheet INA111AU/1K pinout INA111AU/1K equivalent INA111AU/1K replacement INA111AU/1K cross reference INA111AU/1K vs INA114BU/1K INA111AU/1K vs INA129UA INA111AU/1K application circuit INA111AU/1K price INA111AU/1K stock Texas Instruments INA111AU/1K INA111AU 16 pin instrumentation amplifier INA111AU high speed FET input

Verwandte Bauteile & Begriffe

Texas Instruments INA111AU/1K INA111 INA114BU/1K INA129UA AD825AR-16-REEL7 Analog Devices instrumentation amplifier precision analog IC signal-conditioning semiconductor FET input current-feedback topology common-mode rejection ratio input bias current input offset voltage gain-setting resistor 16-pin SOIC SOIC family surface mount medical instrumentation data acquisition bridge sensor interface current measurement RoHS REACH
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen