INA111AU/1K - High-Speed FET Instrumentation Amplifier | TI
部品番号: INA111AU/1K ✓ 生産中INA111AU/1K 概要
An instrumentation amplifier is a differential analog amplifier optimized for measuring small signals superimposed on a larger common-mode voltage. Its internal architecture provides high input impedance, accurate differential gain, and strong common-mode rejection without requiring the user to match closely coupled input resistors. The INA111 belongs to the amplifier hierarchy as a FET-input instrumentation amplifier, a precision analog IC, and ultimately a signal-conditioning semiconductor used between sensors and data-conversion or control systems.
Key electrical features include input bias current below 20 pA, maximum input offset voltage of 500 microvolts, maximum offset drift of 5 microvolts per degree Celsius, and common-mode rejection of at least 106 dB. The low input current simplifies filtering for high-impedance sensors, while the high CMRR suppresses common-mode interference. The current-feedback architecture supports extended bandwidth and rapid settling, which helps preserve accuracy when gain changes occur in measurement systems.
The device uses one external gain-setting resistor, allowing designers to select gain without a resistor network. Because the achievable bandwidth depends on gain, the INA111 is especially useful where measurement speed must be balanced against signal amplification. Its offset and drift characteristics also make it suitable for bridge transducers, biomedical instrumentation, and industrial data-acquisition systems operating across the manufacturer-specified temperature range of -40°C to +85°C.
Typical uses include medical instrumentation, industrial data acquisition, precision bridge-sensor interfaces, current measurement, and low-level differential signal conditioning. In these applications, the amplifier can sit between a sensor and an ADC while rejecting common-mode voltage present on both sensor lines. The design should preserve the common-mode voltage within the device's operating limits and provide appropriate filtering at the inputs.
For PCB implementation, place the gain resistor close to the gain-setting pins, maintain short and symmetric input traces, and decouple the supply pins near the device. Input filtering components should have closely matched impedances if their tolerance could unbalance the differential signal. Because the offset specification is referenced to a particular gain, recalculate accuracy when the external gain resistor differs from the manufacturer's test condition.
This product page combines the manufacturer's electrical and package information with practical design guidance, pin and footprint considerations, application fit, and drop-in replacement analysis for engineers evaluating the INA111AU/1K in new and existing analog signal-chain designs.
ドロップイン代替品: INA111AU/1K — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA111AU/1K (同一形状・フットプリント) — 相違点: Input Bias Current, Input Offset Voltage, Input Offset Voltage Drift, Operating Temperature Range, Package.
INA114BU/1K
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA129UA
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD825AR-16-REEL7
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA111AU/1K 最大定格&電気的特性
| Product Type | High-speed FET-input instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Bandwidth at Gain 10 | 2 MHz |
| Settling Time at Gain 100 | 4 us to 0.01% |
| Gain Range | 1 to over 1000 |
| Gain Configuration | One external resistor |
| Input Bias Current | 20 pA maximum |
| Input Offset Voltage | 500 uV maximum |
| Input Offset Voltage Drift | 5 uV/°C maximum |
| Common-Mode Rejection | 106 dB minimum |
| Architecture | Current feedback |
| 動作温度範囲 | -40°C to +85°C |
| パッケージ | 16-pin SOIC (DW) |
| 実装タイプ | Surface mount |
| RoHS ステータス | Compliant |
| REACH Status | Compliant |
| Automotive Qualification | Not applicable |
| Primary Applications | Medical instrumentation and data acquisition |
INA111AU/1K 16-pin soic (dw) ピン配置ガイド
INA111AU/1K (16-pin soic (dw) パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA111AU/1K.
詳細は データシート をご参照ください。
主な用途
INA111AU/1K の用途: 6 件s: Medical Instrumentation, Industrial Data Acquisition, Precision Bridge Sensor Interface, Current Measurement, Instrumentation Signal Conditioning, Low-Level Differential Sensor Interface.
Medical Instrumentation
The Texas Instruments INA111AU/1K fits low-level biomedical front ends that must separate a small differential sensor signal from a substantial common-mode voltage. Its input bias current below 20 pA minimizes disturbance at high-impedance sources, while the common-mode rejection of at least 106 dB helps suppress physiological and environmental interference. The current-feedback architecture provides 2 MHz bandwidth at gain 10 and 4 us settling to 0.01% at gain 100, which is useful when acquisition timing matters. Offset error still requires attention because the maximum input offset voltage is 500 uV and drift reaches 5 uV/°C. A calibrated frontend should account for those values and apply input protection appropriate to the sensor and patient-protection circuit.
おすすめ
Industrial Data Acquisition
The INA111AU/1K is appropriate for industrial data-acquisition modules conditioning small differential inputs from multiple analog sensors. Its 106 dB minimum common-mode rejection improves signal integrity when sensor outputs sit on a noisy common-mode reference, and the single-resistor gain setting simplifies configuration across different measurement ranges. The 2 MHz bandwidth at gain 10 allows faster sampling than a slow precision-only amplifier, while 4 us settling at gain 100 supports repeated channel acquisition. Designers should maintain balanced input routing, use a quiet ground reference, and verify that the sensor excitation and common-mode range remain compatible with the amplifier's operating limits.
おすすめ
Precision Bridge Sensor Interface
The INA111AU/1K can amplify the differential output of resistive bridge transducers while rejecting the excitation voltage appearing equally on both inputs. Its FET-input bias current below 20 pA reduces errors when the bridge and protection network have high source impedance, and the current-feedback topology provides useful speed at moderate gain. One external resistor sets the gain from 1 to over 1000, allowing the same device to cover different transducer sensitivities. Because bridge outputs can be small, use the 500 uV maximum offset and 5 uV/°C maximum drift in the error budget, provide stable excitation, and place the gain resistor close to the device.
おすすめ
Current Measurement
The INA111AU/1K is suitable for measuring small differential voltages across a low-value shunt or current-sense element. Its high common-mode rejection helps when the shunt voltage is superimposed on a larger supply rail, and the 2 MHz bandwidth at gain 10 provides a useful response for current-loop and power-control signals. Input bias current below 20 pA avoids introducing significant error in high-impedance shunt arrangements. The amplifier's input and common-mode limits must remain within the shunt operating envelope, and Kelvin routing should carry the sense-pair signals together to minimize parasitic voltage. Gain resistor placement and input filtering should avoid creating additional unmatched impedance at the sensitive inputs.
おすすめ
Instrumentation Signal Conditioning
The INA111AU/1K provides a compact differential-to-single-ended conditioning stage for laboratory and test equipment. Engineers can select gain with one resistor, retain a 2 MHz bandwidth at gain 10, and use the 106 dB minimum common-mode rejection to improve signals measured in the presence of shared reference voltage. The device is particularly useful when the system needs faster settling than precision-only instrumentation amplifiers provide: the specified settling time is 4 us to 0.01% at gain 100. Keep analog traces short, provide local supply bypassing, and treat the output-reference connection as a sensitive analog node to preserve measurement accuracy.
おすすめ
Low-Level Differential Sensor Interface
The INA111AU/1K can condition outputs from low-level differential sensors where source current must be minimized and common-mode interference must be rejected. Input bias current below 20 pA helps preserve sensor accuracy, while the 500 uV maximum offset and 5 uV/°C maximum drift establish the principal static-error limits. The single external gain resistor simplifies gain selection, and the 2 MHz bandwidth at gain 10 supports faster signal changes than a low-bandwidth precision amplifier. For reliable operation, verify the common-mode range, use matched input-filter impedances, keep the gain network compact, and provide a low-impedance ground reference. Calibration may be necessary when offset and drift dominate the measurement.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA111AU/1K — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA114BU/1K | INA129UA | AD825AR-16-REEL7 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Package | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC |
| Product Type | FET-input instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier |
| Gain Setting | One external resistor; gain 1 to over 1000 | External resistor gain setting | External resistor gain setting | External resistor gain setting |
主な差別化要因
- High-speed bandwidth at moderate gain (vs INA114BU/1K)
- Fast specified settling at gain 100 (vs INA129UA)
- Cross-brand candidate with the same 16-pin SOIC format (vs AD825AR-16-REEL7)
設計ノート
Place the external gain-setting resistor close to the INA111AU/1K gain pins, and keep the two input paths short and geometrically similar. Differential signals should arrive through matched routing so that parasitic capacitance and resistance do not unbalance the inputs. Keep the output and reference traces away from switching nodes and high-current return paths. The 2 MHz bandwidth at gain 10 makes clean physical routing particularly important.
Use the manufacturer gain equation to select the external resistor, then verify the resulting bandwidth at the operating gain. The INA111AU/1K reaches 2 MHz at gain 10 but provides 4 us settling to 0.01% at gain 100, so bandwidth and acquisition time should both be included in the design. Place any input-filter capacitors close to the device and use matched components to avoid converting common-mode interference into differential error.
Do not assume that every 16-pin SOIC instrumentation amplifier is interchangeable. Before substituting INA114BU/1K, INA129UA, or AD825AR-16-REEL7, compare pin functions, supply limits, input common-mode range, gain-resistor calculation, offset, drift, bandwidth, and settling behavior. The INA111AU/1K has a 500 uV maximum offset and 5 uV/°C maximum drift, so a replacement can change the complete system error budget even when the package matches.
コンプライアンス情報
RoHS and REACH compliance are identified in the Abacus Technologies product catalog. Lead-free, halogen-free, and conflict-minerals status are unknown.