INA163UA/2K5 - 2.5x Low-Noise Instrumentation Amp | TI
Teilenummer: INA163UA/2K5 ✓ AktivINA163UA/2K5 Übersicht
An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while rejecting common-mode interference. The INA163 belongs to the broader hierarchy of instrumentation amplifier, differential amplifier, analog amplifier, and semiconductor. Its internal current-feedback circuitry is particularly useful where the input signal is small, source impedance is low, and cable or grounding noise could obscure the measurement.
The fixed 2.5-times gain of INA163UA/2K5 provides a practical compromise between signal amplification and bandwidth. It can amplify differential sensor, microphone, or balanced-line signals without requiring an external gain-setting network. Its low-noise, low-distortion design also helps preserve signal integrity when the amplified output is measured by an ADC, audio converter, or precision analog front end.
Texas Instruments describes the INA163 as a monolithic instrumentation amplifier using current-feedback circuitry. This architecture supports wide bandwidth and excellent dynamic response over a wide range of gain. The device operates from dual supplies, allowing output signals centered around ground when equal positive and negative rails are used. Its SOIC-14 package is suitable for conventional surface-mount PCB assembly.
Typical uses include low-level balanced microphone amplification, industrial bridge-sensor interfaces, medical instrumentation, audio signal conditioning, and precision data-acquisition front ends. The component is particularly appropriate when a differential source must be amplified while rejecting common-mode voltage present on both input lines.
For implementation, follow the manufacturer pin-description table when connecting inputs, feedback-network connections, reference voltage, and supplies. Maintain suitable input common-mode range and output swing at the selected supply voltage. Decoupling capacitors should be placed close to the supply pins, while the amplifier should be positioned away from noisy switching nodes and high-current return paths.
This page combines the manufacturer device description, ordering information, package details, technical constraints, and practical replacement guidance. It also identifies where an exact drop-in substitute cannot be confirmed without causing a change in gain, pin function, electrical performance, or board-level compatibility.
Drop-in-Alternativen für INA163UA/2K5 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit INA163UA/2K5 (gleiche Bauform und Footprint) – abweichend in Architecture, Package.
INA166UA/2K5
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
INA163UA
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →INA163UA/2K5 Grenzwerte & elektrische Eigenschaften
| Amplifier Type | Low-noise, low-distortion instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Gain | 2.5 V/V |
| Architecture | Current-feedback |
| Supply Voltage Type | Dual supply |
| Minimum Total Supply Voltage | 9 V (±4.5 V) |
| Maximum Total Supply Voltage | 36 V (±18 V) |
| Typical Total Supply Voltage | 30 V (±15 V) |
| Ruhestrom | 12 µA |
| Betriebstemperaturbereich | -40 °C to +85 °C |
| Gehäuse | 14-pin SOIC (D) |
| Montageart | Surface mount |
INA163UA/2K5 14-pin soic (d) Pinbelegungsleitfaden
Pinbelegung für INA163UA/2K5 (14-pin soic (d)-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für INA163UA/2K5.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
INA163UA/2K5 ist geeignet für 6 Anwendungs: Balanced Microphone Preamplifier, Industrial Bridge Sensor Interface, Medical Signal Conditioning, Precision Data Acquisition, Audio Line-Level Conditioning, Low-Level Sensor Measurement.
Balanced Microphone Preamplifier
The INA163UA/2K5 fits low-level balanced audio acquisition because its low-noise, low-distortion architecture is intended for signals such as microphones and other low-impedance sources. The fixed 2.5-times gain adds modest signal level without requiring a general-purpose op-amp stage. Place the device close to the connector and maintain short, symmetric input traces so that cable pickup and ground differences do not become significant relative to the source signal. The current-feedback topology provides the bandwidth and dynamic-response behavior needed for audio paths. Confirm the available output swing, input common-mode range, reference connection, and supply headroom in the manufacturer datasheet before setting the microphone bias and downstream gain.
Empfohlen
Industrial Bridge Sensor Interface
The INA163UA/2K5 is suitable for the input stage of an industrial bridge measurement when the differential millivolt-level signal must be amplified while rejecting common-mode voltage. Its 2.5-times fixed gain provides an initial signal increase, and its low-noise, low-distortion characterization supports precision measurement chains. The dual supply range of ±4.5 V to ±18 V allows a centered output around ground when equal positive and negative rails are used. Keep the bridge excitation return and sensor ground paths away from switching-node currents. Verify input common-mode limits under worst-case bridge imbalance and confirm that the analog-to-digital converter receives the resulting signal without exceeding its input range.
Empfohlen
Medical Signal Conditioning
The INA163UA/2K5 can serve as a low-level front-end element in medical instrumentation when the design requires low noise, low distortion, and differential signal handling. The fixed 2.5-times gain is appropriate as an initial conditioning stage before higher-gain or conversion circuitry. Dual supplies allow the output to remain centered around ground, which can simplify downstream acquisition when system power rails are symmetric. Because medical designs also depend on isolation, leakage, and application-specific validation, this amplifier should be treated as one block within the complete signal chain. Follow the pin-description and application sections of the manufacturer datasheet, and independently verify patient-protection, diagnostic, and regulatory requirements before production use.
Empfohlen
Precision Data Acquisition
The INA163UA/2K5 is useful in a precision data-acquisition front end when a differential sensor output must be conditioned before conversion. Its 2.5-times fixed gain offers a defined scaling factor, while the current-feedback architecture is intended to provide wide bandwidth and excellent dynamic response. Place the amplifier near the sensor or connector and route the differential pair as a compact pair to minimize conversion of common-mode noise into differential error. Use a quiet reference connection and confirm the amplifier output can drive the input network of the following converter without violating output-swing limits. The manufacturer application information and pin table should govern supply decoupling, feedback connections, and operating limits.
Empfohlen
Audio Line-Level Conditioning
The INA163UA/2K5 can condition balanced audio-line signals where modest fixed gain, low distortion, and broad dynamic response are important. Its 2.5-times amplification is useful as an input stage rather than the sole high-gain element in a mixer or preamplifier. The low-noise architecture helps preserve quiet passages, while the low-distortion design is valuable when cascading multiple analog stages. Connect the balanced source to the designated differential inputs and use the datasheet-defined reference arrangement for the downstream circuit. Keep analog return currents separate from digital and power-converter paths, and verify headroom at maximum signal level so that neither the amplifier output nor the following stage approaches clipping.
Empfohlen
Low-Level Sensor Measurement
The INA163UA/2K5 is appropriate for conditioning low-level differential sensor outputs where a fixed 2.5-times gain and noise performance are more useful than adjustable gain. It can provide a clean, scaled representation of a sensor centered around ground while rejecting voltage common to both input terminals. The instrument-amplifier function simplifies the input stage compared with a discrete differential-amplifier network, although external filtering and output buffering may still be required. Evaluate sensor output impedance, cable length, common-mode excursions, and sampling bandwidth together. Use the manufacturer datasheet to select stable external components and establish the reference potential required by the system ADC.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für INA163UA/2K5 – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | INA166UA/2K5 | INA163UA |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 14-pin SOIC (D) | 14-pin SOIC (D) | 14-pin SOIC (D) |
| Product Family | INA163 | INA166 | INA163 |
| Mounting Type | Surface mount | Surface mount | Surface mount |
Wichtigste Unterscheidungsmerkmale
- Exact fixed-gain ordering option (vs. INA163UA)
- INA163 current-feedback performance positioning (vs. INA166UA/2K5)
- Manufacturer-published ordering configuration (vs. INA163UA)
Designhinweise
Route the two differential inputs as a close, symmetric pair and connect them directly to the INA163 pins according to the manufacturer pin-description table. Place the device near the source connector or sensor to minimize pickup of external electromagnetic noise. Keep the input path away from switching inductors, power-converter return currents, and digital clock edges because even a small differential conversion of common-mode noise can become significant at microphone or sensor signal levels.
Use the minimum dual-supply voltage permitted by the design, but confirm that the selected rails provide adequate input common-mode range and output swing for the complete signal range. Texas Instruments specifies operation from ±4.5 V to ±18 V. Place supply-decoupling components close to the relevant pins, connect the ground return thoughtfully, and avoid adding filtering capacitance at the input pins that could alter the current-feedback network's stability or bandwidth.
Establish the reference connection and any external feedback or filtering components exactly as shown in the INA163 manufacturer's application information. Current-feedback amplifiers can interact with excessive output loading and unsuitable output capacitance, so avoid adding an arbitrary output capacitor or low-impedance load without checking stability. Evaluate the complete input-to-output network with the intended source impedance and cable capacitance, particularly for the 2.5-times fixed-gain configuration.
Do not substitute a different INA163 gain option solely because it uses the same 14-pin SOIC outline. Gain-set options can use different feedback connections, while INA166UA/2K5 belongs to a different device family. Compare pin functions, supply limits, common-mode range, bandwidth, noise, distortion, and output behavior before treating either listed candidate as a drop-in replacement. Confirm the exact INA163UA/2K5 ordering code during incoming inspection.
Compliance-Informationen
No definitive compliance status was stated in the manufacturer page excerpts or distributor results. Confirm RoHS, REACH, lead-free, halogen-free, AEC-Q100, and conflict-minerals status using current manufacturer documentation before production release.