ISL83485IP - 3.3V 10Mbps Half-Duplex RS-485/RS-422 | Renesas
Teilenummer: ISL83485IP ✓ AktivISL83485IP Übersicht
An RS-485/RS-422 transceiver is an interface IC that converts logic-level transmit and receive signals into balanced differential signals and back again. It belongs to the communication-interface hierarchy: transceiver > line driver and receiver > RS-485/RS-422 interface IC > semiconductor. This makes the ISL83485IP suitable for industrial control, data acquisition, instrumentation, and equipment interconnects where signal integrity and noise immunity are important.
Key device characteristics include a 3.3 V power supply, half-duplex operation, a maximum data rate of 10 Mbps, and support for both RS-485 and RS-422 standards. The device also uses a low-power BiCMOS implementation. Half-duplex operation means the transmitter and receiver share the same bus pair, so the design must control driver enable and receiver enable states to avoid contention on the network.
The receiver provides a differential input stage for noisy industrial environments, while the balanced bus reduces susceptibility to common-mode noise compared with a single-ended interface. RS-485 operation supports multidrop bus arrangements subject to the applicable termination and biasing rules, whereas RS-422 typically uses a point-to-point or one-driver topology. The exact driver-enable, receiver-enable, and fault-recovery behavior should be confirmed from the manufacturer datasheet before final schematic sign-off.
Typical uses include PLC-to-sensor links, motor-control diagnostics, industrial test equipment, factory monitoring nodes, and embedded systems communicating with remote modules. The 10 Mbps capability is useful for burst-oriented protocols, while the 3.3 V supply simplifies interfacing with modern low-voltage controllers.
For PCB implementation, keep the transceiver and any termination components close to the connector to minimize unbalanced stub length. Use a controlled-impedance differential pair for the balanced bus, provide a solid ground reference, and place the transceiver supply bypass capacitor directly beside its power pin. Avoid long point-to-point stubs because they can degrade signal integrity at the supported 10 Mbps data rate.
This page combines manufacturer specifications, verified distributor availability information, package details, replacement guidance, and application-oriented design notes. It is intended to help engineers evaluate the ISL83485IP against same-package alternatives and plan a robust RS-485 or RS-422 interface implementation.
Drop-in-Alternativen für ISL83485IP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit ISL83485IP (gleiche Bauform und Footprint) – abweichend in Package, Product Type, Maximum Data Rate, Transceiver Configuration, Mounting Type.
ISL83485IBZ-T
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →SP485ES-L
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ISL83483IP
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
ISL83488IP
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ISL83490IP
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ISL83491IP
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ISL83485IP Technische Daten
| Product Type | RS-485/RS-422 transceiver |
| Transceiver Configuration | 1 driver / 1 receiver |
| Duplex Mode | Half duplex |
| Versorgungsspannung | 3.3 V |
| Maximum Data Rate | 10 Mbps |
| Supported Standards | RS-485 and RS-422 |
| Process Technology | BiCMOS |
| Power Consumption Profile | Low power |
| Signal Type | Balanced differential |
| Gehäuse | 8-pin PDIP |
| Montageart | Through-hole |
ISL83485IP Pin-Konfiguration
| Pin 1 | RO — Receiver output |
| Pin 2 | RE — Receiver enable, active-low control |
| Pin 3 | DE — Driver enable, active-high control |
| Pin 4 | DI — Driver input |
| Pin 5 | GND — Ground |
| Pin 6 | Y — Non-inverting differential bus output and receiver input |
| Pin 7 | Z — Inverting differential bus output and receiver input |
| Pin 8 | VCC — Positive supply |
Typische Anwendungen
ISL83485IP ist geeignet für 6 Anwendungs: Industrial PLC and Sensor Bus, Factory Automation Data Acquisition, Motor-Control Diagnostic Interface, Instrumentation and Test Equipment, Embedded Control Module Communication, Building and Energy Monitoring Nodes.
Industrial PLC and Sensor Bus
The ISL83485IP fits 3.3 V PLC and sensor nodes that communicate over a noisy balanced bus. Its one-driver/one-receiver half-duplex arrangement supports shared RS-485 wiring, while the 10 Mbps rating accommodates burst transfers and diagnostic traffic. Place termination at the physical ends of the bus and bias the receiver only once for a multidrop network. Because the half-duplex interface shares the driver and receiver bus pins, firmware must enforce dead time around direction changes so the local transmitter never drives against an active remote node.
Empfohlen
Factory Automation Data Acquisition
The Renesas ISL83485IP can connect low-voltage controller boards to remote instrumentation over RS-422 or RS-485. A 3.3 V supply matches modern processors directly, and differential signaling helps reject common-mode noise generated by relays, motor drives, and switching power supplies. At rates up to 10 Mbps, short point-to-point links can carry synchronized measurements or configuration frames efficiently. Use a twisted, balanced pair with identical routing geometry, terminate the receiver at the far end, and keep the transceiver close to the cable entry to reduce reflections and radiated emissions.
Empfohlen
Motor-Control Diagnostic Interface
The ISL83485IP is useful for carrying position, fault, and configuration information between a motor controller and a supervisory controller. Its balanced differential bus is preferable to a single-ended link in an enclosure containing power-switching stages. The half-duplex 10 Mbps capability supports high refresh rates, but practical field-bus implementations must respect cable length, node count, termination, and grounding rules. Use galvanic isolation when the motor and controller grounds cannot safely be bonded, and select external surge protection based on the installation environment and required immunity level.
Empfohlen
Instrumentation and Test Equipment
The ISL83485IP supports control and measurement systems that require a compact, low-power balanced link between an instrument and a computer or fixture. The 3.3 V operation reduces supply complexity, while the 10 Mbps rate permits short, high-throughput command sequences. A one-driver/one-receiver arrangement can operate as RS-422 for a dedicated point-to-point connection or as RS-485 in a multidrop network. Place the input and output protection close to the connector, use a solid reference plane, and validate eye quality or receiver margins with the intended cable before production.
Empfohlen
Embedded Control Module Communication
The ISL83485IP lets a 3.3 V embedded processor connect to a remote sensor head, actuator controller, or service interface without a separate 5 V transceiver rail. Its low-power BiCMOS implementation is aligned with compact control modules, and the 10 Mbps limit is more than adequate for status polling and short configuration packets. The critical design task is correct half-duplex control. Use the device's receiver-enable and driver-enable pins so the bus changes direction cleanly, and add a receive timeout that returns the interface to the safe state if the remote node stops responding.
Empfohlen
Building and Energy Monitoring Nodes
The ISL83485IP can connect distributed energy-monitoring equipment where sensors and controllers communicate over a wired RS-485 segment. Balanced signaling is useful near switching relays and dimming equipment because it reduces susceptibility to conducted and radiated noise. The transceiver's 3.3 V supply suits modern monitoring nodes, and its 10 Mbps maximum rate permits frequent status aggregation on short bus segments. Follow the bus topology specified for the selected standard, avoid star routing, use a single termination pair at the two physical ends, and consider galvanic isolation at long cable spans or across different ground-potential zones.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ISL83485IP – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ISL83485IBZ-T | SP485ES-L | ISL83483IP | ISL83488IP | ISL83490IP | ISL83491IP |
|---|---|---|---|---|---|---|---|
| Package | 8-pin PDIP | 8-pin PDIP configuration listed as a related family ordering code; board footprint must be revalidated | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Brand | Renesas Electronics | Renesas Electronics | Exar | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Supply Voltage | 3.3 V | 3.3 V | 4.75 V to 5.25 V | 3.3 V family configuration | 3.3 V family configuration | 3.3 V family configuration | 3.3 V family configuration |
| Supported Standards | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 family option | RS-485 and RS-422 family option | RS-485 and RS-422 family option | RS-485 and RS-422 family option |
Wichtigste Unterscheidungsmerkmale
- Direct 3.3 V operation supports modern low-voltage hosts (vs. SP485ES-L)
- Ten-megabit half-duplex operation in a single IC (vs. SP485ES-L)
- Compatible Renesas family sourcing path (vs. ISL83483IP)
Designhinweise
Route the balanced bus as a tightly coupled differential pair with the same geometry on both conductors, and keep the transceiver close to the connector. Place the supply bypass capacitor directly beside VCC and connect the ground return using a low-impedance path. Avoid long stubs, vias, and test pads that create impedance discontinuities. For RS-485 multidrop networks, install termination only at the two physical cable ends and avoid placing termination on every node.
Half-duplex direction control must include a guaranteed dead interval between turning the driver off and enabling the receiver. Firmware delays alone may be insufficient when the bus must handle multiple baud rates or variable frame lengths. Use the manufacturer's timing characteristics to set the maximum turnaround allowance, add a receive timeout, and verify the completed board with the longest intended cable and the highest expected loading rather than relying only on a short bench connection.
Do not treat the 3.3 V ISL83485IP as interchangeable with a 5 V RS-485 transceiver without reviewing the complete supply, logic-threshold, enable, bus-pin, and receiver-output requirements. The SP485ES-L, for example, is identified as a 4.75 V to 5.25 V DIP-8 device with otherwise similar transceiver characteristics. A matching package count is not sufficient proof of drop-in compatibility, particularly when the transceiver's bus-side pin arrangement or control polarity differs.
Keep external protection components close to the cable connector and connect their return path to the board's reference plane. When adding surge or ESD protection, account for its capacitance, which can reduce the usable bandwidth or disturb differential balance at 10 Mbps. Use a matched protection device on Y and Z, maintain symmetric placement, and verify edge quality at the connector. In electrically noisy industrial systems, isolation may be more effective than escalating protection levels on the transceiver itself.
Compliance-Informationen
The ISL83485IP is an industrial RS-485/RS-422 interface IC and is not an automotive-qualified AEC-Q100 device. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations should be confirmed on the current Renesas product documentation or supplier declaration before environmental-compliance release.