Teilenummer: ISL8490IBZ ✓ AktivISL8490IBZ Übersicht
An RS-485/RS-422 transceiver is an interface integrated circuit that converts between single-ended logic signals and differential balanced-line signals. Differential signaling improves noise immunity and allows reliable communication over longer cables or higher-noise industrial environments. The transceiver category belongs to interface ICs within the broader semiconductor hierarchy and is commonly used for multidrop industrial buses, point-to-point links, instrumentation, and building-control networks.
Key characteristics include a 5 Mbps maximum data rate, BiCMOS operation, full-duplex configuration, and operation from a 4.5 V to 5.5 V supply. The ISL8490IBZ is designed for systems that require separate differential transmit and receive lines. Its single-unit-load bus loading allows it to participate in conventional RS-485 networks while reducing the number of nodes permitted by a higher unit-load device.
The electrical architecture uses a differential driver for balanced bus outputs and a differential receiver for detecting small logic-level voltages. Receiver and driver-enable inputs support local control of bus direction and receiver state. Because the part provides separate transmit and receive paths, no multidrop half-duplex direction-control multiplexing is required, which simplifies full-duplex point-to-point and dual-bus designs.
Typical uses include industrial process-control links, factory automation equipment, test and measurement instruments, RS-422-compatible equipment, and isolated or non-isolated communication modules. The 5 Mbps capability is suitable for data links above the slower rates commonly associated with legacy RS-485 systems, while the 8-pin SOIC footprint supports compact board construction.
When laying out the circuit, route the differential pair as a tightly coupled pair with continuous ground reference, terminate the far end of each differential bus, and keep transceiver switching and protection circuitry away from sensitive receive nodes. Confirm that the selected termination, protection, isolation, and connector strategy preserves the signal integrity required at the intended data rate and cable length.
Drop-in-Alternativen für ISL8490IBZ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit ISL8490IBZ (gleiche Bauform und Footprint) – abweichend in Package, Transceiver Configuration.
ISL8490IB
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →ISL8490IBZ Technische Daten
| Product Type | RS-485/RS-422 full-duplex transceiver |
| Transceiver Configuration | 1 transmitter and 1 receiver |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| Maximum Data Rate | 5 Mbps |
| Communication Mode | Full duplex |
| Supported Standards | RS-485 and RS-422 |
| RS-485 Bus Loading | 1 unit load |
| Process Technology | BiCMOS |
| Betriebstemperaturbereich | -40 °C to +85 °C |
| Gehäuse | 8-pin SOIC |
| Package Type | 8-SOIC |
| Montageart | Surface mount |
| Delivery Format | Tube |
ISL8490IBZ Pin-Konfiguration
| Pin 1 | RO — Receiver output |
| Pin 2 | /RE — Active-low receiver enable |
| Pin 3 | DE — Driver enable |
| Pin 4 | DI — Driver data input |
| Pin 5 | GND — Ground |
| Pin 6 | Y — Non-inverting driver output |
| Pin 7 | Z — Inverting driver output |
| Pin 8 | VCC — Positive supply |
Typische Anwendungen
ISL8490IBZ ist geeignet für 6 Anwendungs: Industrial Process-Control Communications, Factory Automation Equipment, Test and Measurement Instrumentation, Building Control and Monitoring Networks, Point-to-Point RS-422 Data Links, Remote Sensor and Data-Acquisition Modules.
Industrial Process-Control Communications
The ISL8490IBZ fits full-duplex industrial links because it combines a 5 V supply range of 4.5 V to 5.5 V with operation up to 5 Mbps. Its separate differential transmitter and receiver allow command data to travel in one direction while acknowledgements or process measurements return simultaneously, avoiding shared-bus direction turnaround delays. The single-unit-load presentation is suitable for conventional RS-485 networks that limit node count. In a process-control instrument, the transceiver can connect a controller to a remote I/O module while providing continuous receive monitoring.
Empfohlen
Factory Automation Equipment
The ISL8490IBZ supports factory automation modules that need reliable balanced communication in electrically noisy environments. Differential RS-485 signaling rejects much of the common-mode noise found near motors, relays, and switching power supplies, while the 5 Mbps capability supports faster data transfer than conventional low-rate RS-485 links. A controller can use separate transmit and receive pairs for continuous status exchange with a servo or programmable-logic module. PCB implementation should preserve a coupled differential route and use surge protection suitable for the installation environment.
Empfohlen
Test and Measurement Instrumentation
The ISL8490IBZ is appropriate for instruments that exchange commands and measured data over a dedicated full-duplex RS-422 link. Its 5 Mbps maximum rate can shorten transfer time for configuration files, sample blocks, and diagnostic records, while the separate receive path permits continuous monitoring of remote equipment. The 8-pin SOIC package also suits compact instrument front ends. Designers should terminate the remote end of each differential pair, maintain a nearby supply bypass capacitor, and protect external cable-connected pins against transients.
Empfohlen
Building Control and Monitoring Networks
The ISL8490IBZ can connect building controllers, sensors, and monitoring units over RS-485 or RS-422 wiring. Its 4.5 V to 5.5 V operating range accommodates regulated 5 V systems, and its single-unit-load interface supports standard bus loading. Full-duplex operation is especially useful between a central controller and a remote monitoring panel because control traffic and status data can proceed simultaneously. Maintain a continuous ground reference beneath the differential pair and use cable termination and protection appropriate for the building's routing and grounding practices.
Empfohlen
Point-to-Point RS-422 Data Links
The ISL8490IBZ supports dedicated RS-422 point-to-point links by providing balanced differential output and input paths at rates up to 5 Mbps. This arrangement is useful when two devices must exchange information simultaneously without sharing a multidrop bus or implementing software-controlled bus turnaround. The device's full-duplex architecture simplifies firmware direction handling because transmit and receive channels remain physically separate. Board designers should pair each differential route with an appropriate ground reference, place termination at the far-end receiver, and keep connector and protection choices consistent with the cable environment.
Empfohlen
Remote Sensor and Data-Acquisition Modules
The ISL8490IBZ can interface a remote sensor or data-acquisition module to a local controller over a balanced bus. Its 5 Mbps capability provides ample link bandwidth for digitized measurements, while the receiver can remain active during transmission in a full-duplex arrangement. The single-unit-load characteristic supports networks designed around the electrical loading of the ISL8490 family. For field-connected equipment, add suitable transient protection, maintain controlled grounding, and verify that cable length and topology preserve usable signal margins at the operating data rate.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für ISL8490IBZ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | ISL8490IB |
|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics |
| Package | 8-pin SOIC | 8-pin SOIC |
| Product Type | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver |
| Transceiver Configuration | 1 transmitter and 1 receiver | 1 transmitter and 1 receiver |
| Supply Voltage Range | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Maximum Data Rate | 5 Mbps | 5 Mbps |
| Communication Mode | Full duplex | Full duplex |
| RS-485 Bus Loading | 1 unit load | 1 unit load |
| Process Technology | BiCMOS | BiCMOS |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C |
Wichtigste Unterscheidungsmerkmale
- Dedicated full-duplex architecture (vs. ISL8490IB)
- High-speed balanced communication (vs. ISL8490IB)
- Single-unit-load RS-485 bus interface (vs. ISL8490IB)
Designhinweise
Route Y and Z as a tightly coupled differential pair with a continuous ground reference beneath or beside the pair. Keep the transceiver, connector, protection components, and receiver-side circuitry in a consistent signal path. Minimize stubs and avoid switching-node copper beneath the differential route. At 5 Mbps, trace geometry, return paths, and connector transitions can influence edge quality as much as the nominal transceiver bandwidth.
Do not treat the ISL8490IBZ as a shared-bus half-duplex device. It is configured for full duplex with separate differential transmit and receive paths, so the board must route both directions correctly. Apply termination at the physical far end of each receiver line rather than at every node. Also confirm driver-enable and receiver-enable polarity in the logic design before releasing the interface from reset.
Place the supply-decoupling capacitor immediately adjacent to VCC and the ground connection to minimize loop area. The family is specified for a 4.5 V to 5.5 V supply, so the source must remain within that range during startup and load transients. Use a quiet 5 V rail when transceiver noise could affect nearby sensitive circuitry, and verify the regulator's transient response because fast data edges can produce short current pulses.