LT1078ACH - Micropower Dual Precision Op Amp | Analog Devices
Teilenummer: LT1078ACH ✓ AktivLT1078ACH Übersicht
An operational amplifier is a high-gain, analog signal-conditioning device used in amplification, filtering, comparison, buffering, and feedback-control circuits. Within the electronic-component hierarchy, the LT1078ACH is a dual precision op amp, meaning that one package contains two amplifiers that can perform independent signal-processing tasks. Its micropower operating class makes it suitable for battery-powered instrumentation and low-current analog systems where supply efficiency is more important than high-bandwidth performance.
The principal features of the LT1078ACH include dual-amplifier integration, micropower operation, single-supply optimization at 5 V, and support for ±15 V supplies. The 50 µA maximum supply current per amplifier is particularly important in portable designs because each active amplifier contributes to the circuit's continuous load. The TO-5 metal-can package also provides a mechanically robust enclosure for legacy and industrial instrumentation.
The precision architecture of the LT1078ACH is intended to minimize error in closed-loop analog systems. As a dual amplifier, it can implement two related functions in one package, such as an instrumentation front-end and a buffer, or a filter stage and an output driver. Operating from a single 5 V supply simplifies battery-powered designs, while the ±15 V capability accommodates conventional industrial analog systems. Designers should still account for input common-mode limits, output swing, bias-current effects, and stability requirements when selecting external compensation and resistors.
Typical uses include low-power sensor signal conditioning, precision filtering, battery-operated measurement instruments, low-current transducers, and dual-stage analog signal chains. The device is also appropriate where two matched amplifier functions reduce board area and component count. Because it is a micropower precision amplifier rather than a high-speed amplifier, applications requiring wide bandwidth, high slew rate, or high output-current capability may benefit from a different device family.
For layout, keep input, feedback, compensation, and decoupling paths short to reduce noise pickup and parasitic feedback. Use a local bypass capacitor at the supply pins and confirm common-mode and output-swing limits against the actual signal range. Start-up behavior, input bias current, and output loading must be checked with the system power source rather than assumed to match a generic dual op amp.
Drop-in-Alternativen für LT1078ACH – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
LT1078AH
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
LM10CH/NOPB
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
LT1078ACH Grenzwerte & elektrische Eigenschaften
| Amplifier Count | 2 amplifiers |
| Product Type | Micropower precision operational amplifier |
| Supply Current per Amplifier | 50 µA maximum |
| Optimized Supply Voltage | 5 V |
| Supported Supply Range | ±15 V |
| Total Supply Voltage Span | 44 V maximum |
| Gehäuse | 8-pin TO-5 metal can |
| Montageart | Through-hole |
LT1078ACH 8-pin to-5 metal can Pinbelegungsleitfaden
Pinbelegung für LT1078ACH (8-pin to-5 metal can-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für LT1078ACH.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
LT1078ACH ist geeignet für 6 Anwendungs: Battery-Powered Sensor Signal Conditioning, Precision Low-Frequency Filtering, Low-Power Transducer Interface, Precision Instrumentation Buffer, Low-Current Data Acquisition Front End, Battery-Operated Reference Buffer.
Battery-Powered Sensor Signal Conditioning
The LT1078ACH fits low-power sensor front ends because each amplifier draws no more than 50 µA and the device is optimized for 5 V single-supply operation. Two amplifiers can provide conditioning and buffering functions without requiring two separate packages. The resulting circuit can amplify weak sensor signals while keeping continuous supply demand low. Designers should account for input bias current, offset voltage, common-mode range, and sensor impedance when selecting external resistors. Stable operation near the supply rails requires confirmation from the manufacturer electrical characteristics rather than an assumption based on generic op-amp behavior.
Empfohlen
Precision Low-Frequency Filtering
The dual precision LT1078ACH can implement active filters, integrators, or buffered gain stages where low supply current is important. Its 50 µA maximum supply current per amplifier reduces the contribution of the active devices to the overall power budget, while two channels allow cascading or parallel signal processing in one package. Stable filter performance depends on the gain, noise gain, component tolerances, and amplifier stability requirements. Use the manufacturer recommended compensation values and verify settling behavior over the intended signal bandwidth. The device is best suited to instrumentation bandwidths rather than high-speed filtering.
Empfohlen
Low-Power Transducer Interface
The LT1078ACH is appropriate for low-level transducer interfaces that require precision amplification and low supply consumption. A single package can implement differential or referenced conditioning stages while operating from a 5 V rail, reducing board area in portable measurement systems. The 50 µA per-amplifier maximum supply current helps extend operating time in battery-powered equipment. Input bias-current effects must be checked against the transducer source impedance, and the common-mode voltage must remain within the manufacturer's permitted range. Output loading and sensor-ground offsets also require careful grounding to avoid degrading measurement accuracy.
Empfohlen
Precision Instrumentation Buffer
The LT1078ACH can provide input buffering and gain functions in compact analytical or test instruments where supply efficiency matters. Its dual topology supports two buffered channels or a signal-conditioning pair, while the micropower characteristic limits continuous consumption. A metal-can package is mechanically compatible with traditional through-hole instrumentation layouts, although the exact pin orientation must follow the manufacturer drawing. Check input offset, bias current, output swing, and capacitive-load drive before using the amplifier directly with long cables or high-capacitance nodes. Short traces and careful grounding are important when handling low-level laboratory signals.
Empfohlen
Low-Current Data Acquisition Front End
The LT1078ACH can amplify and buffer inputs in a low-current data-acquisition channel while its 50 µA maximum supply current per amplifier limits the active-circuit burden. Operating from a single 5 V supply simplifies portable acquisition systems, and the second channel can monitor a reference or provide an additional conditioned output. Signal-chain accuracy still depends on offset and bias-current behavior, which are not interchangeable across precision amplifiers. For multiplexed or long-cable inputs, add suitable protection and isolation as required. Confirm the device's input and output ranges against the converter or sensor architecture before layout release.
Empfohlen
Battery-Operated Reference Buffer
The LT1078ACH can buffer a low-power voltage reference before it drives an ADC, DAC, or resistive sensor network. Its 50 µA maximum supply current per amplifier helps maintain a low overall power budget, and the 5 V single-supply optimization fits many mixed-signal portable systems. Buffering is useful when the source cannot drive the required load without introducing an error. Verify reference accuracy, capacitive loading, output swing, and stability in the actual reference network. The TO-5 package supports through-hole assembly, but pin 1 orientation and the pin functions must be taken directly from the manufacturer package drawing.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für LT1078ACH – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | LT1078AH | LM10CH/NOPB |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Texas Instruments |
| Package | 8-pin TO-5 metal can | 8-pin TO-5 metal can | 8-pin TO-5 metal can |
| Amplifier Count | 2 amplifiers | 2 amplifiers | 2 amplifiers |
| Product Class | Micropower precision dual op amp | Micropower precision dual op amp | Precision dual op amp |
Wichtigste Unterscheidungsmerkmale
- Explicit 5 V single-supply optimization (vs. LM10CH/NOPB)
- Documented micropower supply requirement (vs. LM10CH/NOPB)
- Same-family dual precision topology (vs. LM10CH/NOPB)
Designhinweise
Budget the LT1078ACH using the documented maximum of 50 µA per amplifier, or 100 µA for both channels before allowing for supply-voltage and operating-condition effects. Add the load current drawn by the input network, feedback resistors, reference circuit, and bypass components. A 5 V single supply simplifies routing, but the output and input operating ranges must remain compatible with the signal at startup, shutdown, and overload conditions.
Place the bypass capacitor and any additional supply-decoupling component directly between the device supply pin and ground connection. Keep feedback resistors and compensation components close to their associated amplifier pins, and route high-impedance input traces away from power and switching nodes. Because the TO-5 metal can can act as an electrostatic shield, follow the manufacturer's grounding recommendation rather than connecting the can arbitrarily.
Do not substitute a surface-mount LT1078 ordering option without redesigning the footprint and checking the pin configuration. Likewise, confirm that the replacement amplifier's common-mode range, output swing, offset voltage, input bias current, and stability behavior meet the circuit requirements. A matching 8-pin outline alone is insufficient to establish drop-in compatibility for precision analog circuitry.
Compliance-Informationen
The manufacturer product-page excerpt does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for LT1078ACH. Confirm the exact ordering code against Analog Devices compliance documentation before making a declaration.