MAX232ACWE+T - 116kbps Dual RS-232 Transceiver | Analog Devices
Teilenummer: MAX232ACWE+T ✓ AktivMAX232ACWE+T Übersicht
An RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 line levels and converts received RS-232 signals back into digital logic levels. Within the signal-chain hierarchy, the MAX232 belongs to the RS-232 interface transceiver class, combining transmitter, receiver, and voltage-generation functions in one package. This integration allows a compact equipment port to communicate with legacy serial equipment without requiring a separate external charge-pump supply.
The MAX232ACWE+T provides two transmit channels and two receive channels in one device. Its listed 116 kbps data rate is suitable for conventional asynchronous serial communication rather than high-speed differential buses such as RS-485. The 5.5 V supply requirement permits operation in systems where only a positive 5 V rail is readily available. Its dual-channel organization also reduces component count when two RS-232 ports must share the same logic interface.
The MAX232 family is designed for EIA/TIA-232E and V.28/V.24 communication interfaces, including equipment where ±12 V cannot be supplied. The integrated line-driver and receiver functions provide the electrical interface between CMOS/TTL-compatible logic and RS-232 lines. Device variants exist in multiple package and temperature options, so engineers should confirm the exact ordering suffix when matching a board footprint and environmental requirement.
Typical uses include industrial control consoles, laboratory instrumentation, point-of-sale equipment, service interfaces, embedded serial ports, and data-acquisition systems. A two-driver, two-receiver arrangement is especially useful when one equipment enclosure must support two independent RS-232 links or combine full-duplex operation on two ports.
PCB design should preserve the pin arrangement defined by the SOIC-16W footprint and follow the capacitor and charge-pump guidance in the manufacturer data sheet. Keep the interface connector, protection network, and transceiver on a controlled impedance-free point-to-point RS-232 path, and provide suitable grounding rather than relying on the logic ground as a substitute for a proper cable shield connection.
This page combines the exact MAX232ACWE+T ordering information, verified manufacturer specifications, sourcing guidance, interface-use guidance, and a careful review of drop-in alternatives. It is intended to help engineers identify the correct package variant, evaluate replacement options, and implement a robust RS-232 interface without overlooking footprint or qualification differences.
Drop-in-Alternativen für MAX232ACWE+T – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit MAX232ACWE+T (gleiche Bauform und Footprint) – abweichend in Interface Standard, Maximum Data Rate, Mounting Type, Package, Product Type.
MAX232AEWE+T
✅ Drop-In ⚠️ Spezifikationen ungeprüft📋 Referenzalternative (nicht im Katalog)
SP3232EBCN-L/TR
✅ Drop-In✓ Auf Lager
$0.7711 / Stück
Datenblatt ansehen →MAX232ACWE+T Technische Daten
| Product Type | Dual RS-232 line transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Maximum Data Rate | 116 kbps |
| Versorgungsspannung | 5.5 V |
| Interface Standard | EIA/TIA-232E, V.28 and V.24 |
| Duplex Mode | Full duplex |
| Logic Compatibility | CMOS |
| Gehäuse | SOIC-16W, 16 pins |
| Montagestil | Surface mount |
| Shipping Package | Tape and reel |
MAX232ACWE+T tape and reel Pinbelegungsleitfaden
Pinbelegung für MAX232ACWE+T (tape and reel-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für MAX232ACWE+T.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
MAX232ACWE+T ist geeignet für 6 Anwendungs: Industrial Control Console, Laboratory Test Instrument, Point-of-Sale Terminal, Data Acquisition Equipment, Embedded Serial Gateway, Service and Diagnostics Port.
Industrial Control Console
The MAX232ACWE+T fits a console interface that must communicate with legacy RS-232 equipment through one full-duplex link and one additional channel. Its two drivers and two receivers provide the required transmit and receive paths while its 116 kbps rate matches conventional asynchronous serial-control traffic. The 5.5 V supply is useful in industrial controllers that already generate a positive 5 V rail. Place the IC near the connector and connect the charge-pump capacitors according to the manufacturer data sheet to keep the switching-generated supply ripple away from sensitive logic. Confirm the ordering suffix temperature range for the intended enclosure and add connector-side surge protection when the interface leaves the controlled equipment area.
Empfohlen
Laboratory Test Instrument
A laboratory instrument can use the MAX232ACWE+T to connect a controller or embedded system to a PC-based service port without requiring a separate negative supply. Two channels allow independent command and diagnostic links, while the listed 116 kbps rate is suitable for configuration exchange and status polling rather than continuous bulk transfer. The integrated receiver and driver circuitry simplifies the logic-side interface, but the external cable still requires appropriate ESD and surge protection. Keep the ground reference and cable-shield strategy defined by the instrument architecture, and verify that the 5.5 V supply remains within the operating limits listed for the exact ordering suffix.
Empfohlen
Point-of-Sale Terminal
The MAX232ACWE+T is suitable for a point-of-sale or service terminal that connects a main board to a peripheral through RS-232. The two transmitters and two receivers can support two serial paths, such as a primary peripheral and an auxiliary device, while the 116 kbps rate covers command traffic, receipt data, and configuration updates of moderate length. Because point-of-sale equipment may share power with motors, displays, and scanners, route the transceiver and charge-pump return current carefully. Place the interface protection close to the connector, and use the manufacturer's capacitor configuration to prevent power-supply disturbance from affecting the logic interface.
Empfohlen
Data Acquisition Equipment
The MAX232ACWE+T can provide a compact PC-to-instrument data-acquisition link when the transfer consists of commands and sampled status records rather than sustained high-rate streaming. The 116 kbps maximum rate establishes the practical ceiling for the RS-232 channel, while two channels can separate a control command path from a data-response path. The 5.5 V supply is convenient for a 5 V instrument architecture. Preserve the specified charge-pump capacitor placement and keep the RS-232 traces away from high-gain analog input paths. If the acquisition system requires continuous high-throughput transfer or galvanic isolation, select an interface architecture with a higher data rate or an isolated digital link.
Empfohlen
Embedded Serial Gateway
An embedded gateway can use the MAX232ACWE+T when it must bridge modern logic to one or two legacy RS-232 ports. The dual transmitter and receiver arrangement allows a compact converter to support two physical serial links, and the 116 kbps rate is appropriate for configuration, diagnostic, and supervisory protocols. The device's 5.5 V requirement can simplify integration into a 5 V industrial or communications design. Treat the RS-232 connector as an electrically harsh boundary by placing suitable protection at the connector entry. Confirm the exact pin functions, capacitor connections, and package footprint against the manufacturer data sheet before adapting an existing gateway board.
Empfohlen
Service and Diagnostics Port
The MAX232ACWE+T fits a service port intended for configuration, firmware-log, and diagnostic access on embedded equipment. At 116 kbps, it supports ordinary terminal sessions and short text-based logs while limiting the host software's timeout and flow-control complexity. Two channels provide flexibility for separating service traffic from another RS-232 function. In a compact enclosure, exposed connector pins can receive ESD events, so add protection appropriate to the installation while retaining a short protected route to the transceiver. Validate the ground reference to avoid injecting surge current into the logic ground and follow the manufacturer data sheet for capacitor placement and supply decoupling.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für MAX232ACWE+T – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | MAX232AEWE+T | SP3232EBCN-L |
|---|---|---|---|
| Package | SOIC-16W | SOIC-16W | SOIC-16 |
| Brand | Analog Devices | Analog Devices | MaxLinear |
| Maximum Data Rate | 116 kbps | 116 kbps | 250 kbps |
| Number of Drivers | 2 | 2 | 2 |
| Number of Receivers | 2 | 2 | 2 |
| Duplex Mode | Full duplex | Full duplex | Full duplex |
Wichtigste Unterscheidungsmerkmale
- Two complete RS-232 channels in one package (vs. MAX232AEWE+T)
- Cross-brand option with documented pin compatibility (vs. SP3232EBCN-L)
- Established 116 kbps operating class (vs. MAX232EWE+T)
Designhinweise
Follow the manufacturer data sheet exactly when placing the charge-pump capacitors and supply bypass components. These components must be connected to the designated pins without long intervening traces, because long loops increase radiated noise and coupling into adjacent logic. Confirm that the PCB land pattern is SOIC-16W rather than a narrower 16-pin SOIC footprint; the two packages can have similar pin counts but different lead spacing and body widths.
Do not select MAX232EWE+T solely because it belongs to the same family. Its listed 200 kbps rate is 84 kbps higher than the MAX232ACWE+T's 116 kbps rate, indicating a different slew-rate profile. A higher edge rate can increase ringing and EMI on imperfectly terminated cables. Preserve the original MAX232ACWE+T operating mode when conducting a direct substitution review.
Treat the connector and transceiver as one protected interface region. Place any connector-side TVS or surge-protection elements before the transceiver pins, provide a low-impedance ground return for surge current, and keep unprotected RS-232 traces away from sensitive analog and clock paths. Check the external line-driver and receiver enable or shutdown functions against the system power sequence so that no driver is active while the interface state is uncertain.
RS-232 is a point-to-point cable interface, not a terminated high-speed bus. Nevertheless, faster edge rates can reveal reflections, ringing, and common-mode susceptibility. Use a short, appropriately shielded cable, connect the signal reference and shield according to the equipment grounding strategy, and avoid long unprotected traces inside the enclosure. Validate edge-rate-dependent behavior with an oscilloscope and representative cable lengths when substituting a higher-speed device.
Compliance-Informationen
The Exact MAX232ACWE+T ordering suffix was not identified as RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals compliant in the cited pages. Confirm these attributes in the current manufacturer product declaration or material declaration for the exact part.