MAX378CWG+ - 8:1 High-Voltage Fault-Protected MUX | Analog Devices
Teilenummer: MAX378CWG+ ✓ AktivMAX378CWG+ Übersicht
An analog multiplexer is an analog switch that connects one of several inputs to a common output or selects one signal path from multiple candidates. The MAX378 belongs to the analog switch and multiplexer hierarchy, where the 8:1 configuration provides eight single-ended inputs and one output. This makes the device useful for compact signal-routing systems in test equipment, industrial control, instrumentation, and data-acquisition equipment where one source must be selected from several measured or sensed signals.
Key features include a maximum on-resistance of 3.5 kOhm, 1 us maximum turn-on time, and 300 ns maximum turn-off time. The fault-protected architecture is especially important in high-voltage systems because the internal transistor arrangement turns the channels off if the supply rails collapse while external input signals are still present. The single 5 V to 36 V or dual ±18 V supply choices support both conventional and bipolar analog systems. The 24-pin SOIC package also provides a surface-mount implementation for industrial and instrumentation equipment.
The MAX378 uses a series N-channel, P-channel, and N-channel switch structure. Its digital address and enable controls route the selected analog input to the common output while isolating other channels. The 3.5 kOhm maximum on-resistance is appropriate for medium-impedance measurement paths, control signals, and test points where lower resistance is not essential. Designers should account for this resistance in the source impedance, settling time, and signal-accuracy calculations of the complete measurement chain.
Typical applications include automated test systems, battery and power-system monitoring, industrial process control, programmable instrumentation, and multichannel sensor acquisition. In each case, the multiplexer reduces the number of input channels required by the host analog-to-digital converter or measurement circuit. The common MAX378 family also includes the MAX379 differential multiplexer for applications requiring paired signal selection rather than a single-ended 8:1 arrangement.
For reliable operation, treat the maximum 36 V single-supply or ±18 V dual-supply limits as absolute constraints. Keep signal paths short, provide a stable low-impedance supply reference, and use suitable protection networks when external inputs can exceed the selected supply range. Verify address transitions, disable timing, settling behavior, and channel isolation in the final analog signal path.
This page combines the manufacturer product information with practical routing, protection, timing, and layout considerations. It also organizes the available drop-in information by package and electrical match so engineers can assess replacement decisions without confusing a pin-compatible part with merely similar multiplexer functionality.
Drop-in-Alternativen für MAX378CWG+ – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
MAX378CWG
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX378CWG+T
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MAX378CWG+ Technische Daten
| Multiplexer Configuration | 8:1 single-ended, 1-of-8 |
| Number of Channels | 8 channels |
| Maximum On-Resistance | 3.5 kOhm |
| Maximum Turn-On Time | 1 us |
| Maximum Turn-Off Time | 300 ns |
| Single-Supply Voltage Range | 5 V to 36 V |
| Dual-Supply Voltage Range | +/-18 V |
| Fault Protection | Series N-channel/P-channel/N-channel structure |
| Powered-Off Fault Current | A few nanoamperes per manufacturer product description |
| Gehäuse | 24-pin SOIC |
| Montageart | Surface Mount |
| Betriebstemperaturbereich | 0 C to +70 C |
| Production Status | Production |
MAX378CWG+ 24-pin soic Pinbelegungsleitfaden
Pinbelegung für MAX378CWG+ (24-pin soic-Gehäuse). Pin-Nummerierung, Funktionen und Anschlussdiagramme sind im Herstellerdatenblatt definiert. Entnehmen Sie diesem den genauen Footprint und Lötrichtlinien.
Keine detaillierten Pinbelegungsdaten verfügbar für MAX378CWG+.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
MAX378CWG+ ist geeignet für 6 Anwendungs: Battery Cell Monitoring, Automated Test Equipment, Industrial Process Control, Programmable Instrumentation, Data Acquisition Systems, High-Voltage Signal Routing.
Battery Cell Monitoring
The MAX378CWG+ is appropriate for multi-cell battery monitoring because one 8:1 multiplexer can connect eight single-ended cell-sense inputs to a common measurement channel. Its maximum on-resistance of 3.5 kOhm is suitable when the ADC input presents a sufficiently high impedance and the cell-sensing network has a much lower source impedance. The manufacturer’s fault-protected N-channel/P-channel/N-channel structure is valuable if a measurement rail is disabled while external cell voltages remain present. Designers must add cell-level filtering, input protection, and balancing functions outside the multiplexer and confirm that every selected voltage remains within the device’s absolute-maximum limits.
Empfohlen
Automated Test Equipment
The MAX378CWG+ can route eight single-ended test points to a shared measurement front end in automated test equipment. Its 1 us maximum turn-on time and 300 ns maximum turn-off time support controlled address selection, while the 3.5 kOhm maximum on-resistance should be included in test-path error budgets. The 24-pin SOIC package supports compact surface-mount instrument boards. For high-accuracy measurements, use low-capacitance routing, a suitable settling period after switching, and an ADC whose input impedance does not create unacceptable divider error with the switch resistance.
Empfohlen
Industrial Process Control
The MAX378CWG+ fits industrial process-control boards that must sample several analog sensor outputs or control voltages through one shared controller input. Eight single-ended channels reduce front-end wiring and converter count, while fault protection helps manage accidental supply-sequence conditions. The 0 C to +70 C operating range identified in the MAX378 family comparison should be checked against the enclosure’s temperature range. For noisy factory environments, place filtering close to the source, maintain a low-impedance ground reference, and keep the multiplexed trace away from switching power nodes and motor-control traces.
Empfohlen
Programmable Instrumentation
The MAX378CWG+ enables a programmable instrument to select among eight external analog inputs without allocating a separate front-end channel to each source. Its 8:1 configuration is useful for source selection, calibration-node routing, and programmable divider networks. With a maximum on-resistance of 3.5 kOhm, the device is most appropriate for medium-impedance sources rather than precision low-level bridges. Account for resistance-induced gain error, input leakage, and finite settling time when calculating measurement uncertainty. Follow the manufacturer pin table closely because control inputs, supplies, and analog paths must match the selected board revision.
Empfohlen
Data Acquisition Systems
The MAX378CWG+ can expand a compact data-acquisition system by routing eight single-ended sensor outputs into one common analog input. This architecture lowers the number of ADC channels required when samples can be selected sequentially. The manufacturer’s 5 V to 36 V single-supply or ±18 V dual-supply flexibility allows integration into different analog power architectures. Engineering trade-offs include the 3.5 kOhm maximum on-resistance, 1 us turn-on time, and 300 ns turn-off time. Use matched acquisition timing, calibrated channel offsets, and software that discards samples until the complete mux and ADC settling interval has elapsed.
Empfohlen
High-Voltage Signal Routing
The MAX378CWG+ is suited to high-voltage signal-routing stages where input signals may remain present while the multiplexer supply is off. Its series N-channel/P-channel/N-channel structure turns the channels off under that condition and limits residual current to a few nanoamperes according to the manufacturer description. The 36 V maximum single supply supports higher-voltage instrumentation than conventional low-voltage analog switches. Protection above the device ratings is still required, including clamps, series impedance, and energy limiting, because internal fault protection does not authorize signals beyond the published absolute-maximum ratings.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für MAX378CWG+ – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | MAX378CWG | MAX378CWG+T |
|---|---|---|---|
| Package | 24-pin SOIC | 24-pin SOIC | 24-pin SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Multiplexer Configuration | 8:1 single-ended, 1-of-8 | 8:1 single-ended, 1-of-8 | 8:1 single-ended, 1-of-8 |
| Maximum On-Resistance | 3.5 kOhm | 3.5 kOhm | 3.5 kOhm |
| Maximum Turn-On Time | 1 us | 1 us | 1 us |
| Maximum Turn-Off Time | 300 ns | 300 ns | 300 ns |
| Maximum Dual-Supply Voltage | +/-18 V | +/-18 V | +/-18 V |
| Operating Temperature Range | 0 C to +70 C | 0 C to +70 C | 0 C to +70 C |
| Fault Protection | Series N-channel/P-channel/N-channel structure | Series N-channel/P-channel/N-channel structure | Series N-channel/P-channel/N-channel structure |
Wichtigste Unterscheidungsmerkmale
- Provides eight single-ended inputs in one 24-pin SOIC multiplexer (vs. MAX379)
- Maintains fault isolation in powered-down signal paths (vs. Conventional low-voltage analog switches)
- Supports broad single-supply operation (vs. 5 V-only analog switches)
Designhinweise
Include the 3.5 kOhm maximum on-resistance when calculating channel gain error. With a source impedance of Rs, the switch creates a divider; for example, a 10 kOhm source and an ADC input much greater than 3.5 kOhm would produce approximately 9.2% gain loss before accounting for ADC loading. Use a lower source impedance or correct the gain in calibration when the measurement accuracy cannot tolerate that error.
Design the supply rails so normal input voltages never exceed the MAX378CWG+ absolute-maximum limits. The device can be operated from 5 V to 36 V or from ±18 V dual supplies, but fault protection is not permission to apply arbitrary overvoltage. Add external clamps, current limiting, and controlled source impedance for external nodes that can be driven above or below the local rails.
Route the eight analog inputs and the common output as short, guarded traces, and connect the device ground pins using a low-impedance plane. Keep mux output routing away from switching power converters, relays, and high-current motor nodes. If the source impedance is high, add guarded input traces or differential pairings where the circuit topology allows, because leakage and capacitive coupling can undermine the benefit of eight-channel multiplexing.
Do not assume the 1 us turn-on time is the complete acquisition settling time. The total interval also includes address-control propagation, switch settling, output RC charging, and ADC acquisition and conversion. In firmware, select the channel, wait through the complete worst-case settling interval, and then sample. This prevents transient charge from a previous channel from appearing as a measurement error.
Compliance-Informationen