STMicroelectronics

MPXV5100GC7U - 100kPa Gauge Pressure Sensor, 5V | STMicroelectronics

Teilenummer: MPXV5100GC7U ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
4.75 V to 5.25 V (typical 5 V) Vdss 8-DIP (0.550" / 13.97 mm), Top Port Package
Ab $8.95 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $13.5 $13,50
10 $12.15 $121,50
100 $11.05 $1.105,00
500 $10 $5.000,00
1.000 $8.95 $8.950,00
ℹ️ Alle Preise sind in USD

MPXV5100GC7U Übersicht

The STMicroelectronics MPXV5100GC7U is an integrated piezoresistive pressure transducer that delivers a calibrated, temperature-compensated analog output for gauge pressures from 0 to 100 kPa (0 to 14.5 PSI). It operates from a single 5 V supply, provides a 0.2 V to 4.7 V ratiometric output across its pressure range, and is housed in an 8-DIP package (0.550" body, 13.97 mm) with a top-mounted 0.13" (3.17 mm) tube port for ease of pneumatic connection.

A piezoresistive pressure sensor is a solid-state transducer in which strain gauges diffused into a silicon diaphragm change resistance in proportion to applied pressure; the die integrates the sensor, signal conditioning, and calibration in a single monolithic silicon substrate. In the broader sensor taxonomy, the MPXV5100GC7U belongs to the MEMS pressure sensor family, which sits under semiconductor sensors and within signal-conditioning sensor modules used by microcontrollers with analog-to-digital inputs.

Key specifications include a maximum pressure rating of 400 kPa, a sensitivity of 45 mV/kPa, an accuracy of 1.5% over 0 to 85 °C, and a response time of 1.0 ms. The package offers a vented-gauge reference through the side port, allowing absolute atmospheric reference for differential measurements in real-world installations.

The architecture combines advanced micromachining, thin-film metallization, and bipolar signal processing to deliver a linear analog output. The internal ASIC performs offset calibration, span calibration, and temperature compensation at the wafer level, removing the need for external user trimming in most applications while keeping the pin count and BOM low.

Typical applications include medical patient monitoring (respiratory and blood pressure instrumentation), industrial process controls, pump and motor pressure feedback, HVAC pressure switching, and weather station barometric measurement. The vented-gauge configuration also makes the part well suited to altitude and small-differential measurements where atmospheric reference is required.

When designing with the MPXV5100GC7U, pay attention to input supply decoupling (a 100 nF plus 10 µF combination is recommended near VCC), the orientation of the vent port relative to the application environment, and the proper sizing of the analog input bandwidth on the host ADC to avoid aliasing the 1 ms response.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes that go beyond the manufacturer datasheet's typical application section to help engineers shorten the design cycle.

Drop-in-Alternativen für MPXV5100GC7U – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPXV5100GC7U (gleiche Bauform und Footprint) – abweichend in Accuracy, Mounting Type, Operating Pressure Range, Output Type, Output Voltage Range.

NXP Semiconductors
Accuracy: ±2.5% (0 to 85 °C)
Mounting Type: Through-Hole (SIP)
Operating Pressure Range: 0 kPa to 100 kPa (0 to 14.5 PSI)
Vergleichen mit MPXV5100GC7U →
NXP Semiconductors
Accuracy: 2.5 % of Full-Scale Span (typ.)
Mounting Type: Surface Mount
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Vergleichen mit MPXV5100GC7U →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPXV5100GP

✅ Drop-In
📦 8-DIP top port
same 0-100 kPa vented-gauge range, same 5 V ratiometric output, same 8-DIP footprint but horizontal port orientation vs vertical

📋 Referenzalternative (nicht im Katalog)

MPX5100DP

✅ Drop-In
NXP Semiconductors
📦 8-DIP (DIP)
Differential · 0 kPa to 100 kPa (0 to 14.5 PSI) · 5 V (nominal) · 0.2 V to 4.7 V (ratiometric, ~4.5 V span) · Analog, ratiometric to Vcc · ±2.5% (0 to 85 °C) · 45 mV/kPa nominal

✓ Auf Lager

$12.03 / Stück

Datenblatt ansehen →

MPXV5100GC6U

✅ Drop-In
NXP Semiconductors
📦 8-DIP (case 1317-01 family)
NXP Semiconductors (formerly Freescale, Motorola) · Pressure Sensor, Vented Gauge · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · Vented Gauge · 2.5 % of Full-Scale Span (typ.) · Analog, Ratiometric Voltage · 0.2 V to 4.7 V (at 5 V supply) · 4.75 V to 5.25 V

✓ Auf Lager

$11.05 / Stück

Datenblatt ansehen →

MPXV5100G

✅ Drop-In
📦 8-DIP top port
same 0-100 kPa vented-gauge spec, 8-DIP untrimmed variant - confirm calibration procedure before use

📋 Referenzalternative (nicht im Katalog)

MPXV5100GC7T1

✅ Drop-In
📦 8-DIP top port
same die, same 0-100 kPa spec - tape-and-reel packaging variant with identical electrical performance

📋 Referenzalternative (nicht im Katalog)

MPX5100G

✅ Drop-In
📦 8-DIP (MPX family)
same 0-100 kPa MPX5100 family heritage, NXP legacy datasheet designation, verify pin ordering against current ST pinout

📋 Referenzalternative (nicht im Katalog)

MPXV5100GC7U Grenzwerte & elektrische Eigenschaften

Pressure Type Vented Gauge
Operating Pressure Range 0 to 100 kPa (0 to 14.5 PSI)
Maximum Overload Pressure 400 kPa
Versorgungsspannung 4.75 V to 5.25 V (typical 5 V)
Ausgangsspannungsbereich 0.2 V to 4.7 V
Sensitivity 45 mV/kPa
Accuracy 1.5 % over 0 °C to 85 °C
Response Time 1.0 ms
Betriebstemperatur -40 °C to +125 °C
Gehäuse 8-DIP (0.550" / 13.97 mm), Top Port
Port Type Male 0.13" (3.17 mm) tube, vertical
Montageart Through-hole (DIP)
RoHS-Status Compliant
Ausgangstyp Analog ratiometric, single-ended

MPXV5100GC7U Pin-Konfiguration

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
Pin 1 NC — No connection (gauge-vented configuration)
Pin 2 NC — No connection (gauge-vented configuration)
Pin 3 NC — No connection (gauge-vented configuration)
Pin 4 NC — No connection (gauge-vented configuration)
Pin 5 GND — Ground reference
Pin 6 VCC — 5 V supply input
Pin 7 VOUT — Analog ratiometric pressure output (0.2 V to 4.7 V)
Pin 8 NC — No connection (gauge-vented configuration)

Typische Anwendungen

MPXV5100GC7U ist geeignet für 7 Anwendungs: Medical Patient Monitoring - Blood Pressure, Industrial Process Control, Pump and Motor Pressure Feedback, HVAC Pressure Switching, Weather Station Barometric Measurement, Respiratory Equipment / Ventilator Pressure Sensing, Automotive Manifold Pressure Monitoring.

💊

Medical Patient Monitoring - Blood Pressure

The MPXV5100GC7U delivers a calibrated 0.2 V to 4.7 V ratiometric output across 0 to 100 kPa, matching the dynamic range of non-invasive blood pressure cuffs in patient monitoring systems. Its 1.5% accuracy over 0 °C to 85 °C supports reliable systolic/diastolic determination, while the vented-gauge reference eliminates barometric compensation circuitry. The 1.0 ms response time tracks cuff deflation transients accurately; pair the output with a 12-bit or 14-bit SAR ADC and a 5 V low-drift reference for best end-to-end resolution.

🏭

Industrial Process Control

In process-control loops, the MPXV5100GC7U monitors line pressures in 0 to 100 kPa systems such as clean-room air lines, vacuum roughing, and low-pressure gas distribution. The 45 mV/kPa sensitivity directly drives 4 mA to 20 mA current loop converters via an op-amp summing stage, while the 400 kPa overload rating tolerates pressure spikes during valve closure. The 5 V single-supply operation simplifies interface to industrial PLC analog input modules; add a TVS diode and EMI filter on the output for factory-floor deployments.

⚡

Pump and Motor Pressure Feedback

The MPXV5100GC7U closes the feedback loop on variable-speed pumps and hydraulic motor controllers, where 0 to 100 kPa discharge pressure must be tracked with millisecond-class response. The 1.0 ms response time captures dynamic pressure events like valve closure, and the vented-gauge reference rejects atmospheric drift in outdoor pump installations. The ratiometric output ties directly to a motor-controller ADC; add software proportional-integral control to maintain setpoint pressure across varying load conditions.

🌐

HVAC Pressure Switching

Building automation systems use the MPXV5100GC7U as a static-pressure sensor across fan coils, filter-monitoring manifolds, and duct static-pressure taps in the 0 to 100 kPa range. Its analog output integrates with BACnet or Modbus gateways through a microcontroller ADC, providing continuous pressure readings rather than the on/off behavior of mechanical pressure switches. The vented-gauge reference corrects for altitude and barometric pressure automatically, simplifying commissioning in mixed-elevation installations.

📡

Weather Station Barometric Measurement

Although the MPXV5100GC7U is a vented-gauge sensor rather than a true absolute barometer, it can be repurposed with an external sealed vacuum reference to act as a low-cost barometric transducer at high-altitude or weather-logging stations. Its 0.2 V to 4.7 V output drives a low-power MCU ADC for logging, and the 1.5% accuracy over temperature is acceptable for consumer-grade weather instruments. The rugged 8-DIP package handles outdoor enclosure mounting without additional mechanical protection.

💊

Respiratory Equipment / Ventilator Pressure Sensing

Ventilator and CPAP machine designers leverage the MPXV5100GC7U's 0 to 100 kPa range to measure both inspiratory and expiratory circuit pressure in respiratory therapy devices. The 1.0 ms response time tracks breath-cycle pressure transitions accurately, and the analog output simplifies integration with mixed-signal front ends. Designers must validate IEC 60601-1 system-level compliance and add appropriate isolation barriers; STMicroelectronics provides test procedures for medical-device qualification.

🚗

Automotive Manifold Pressure Monitoring

While not AEC-Q100 qualified by default, the MPXV5100GC7U's 0 to 100 kPa gauge range and 5 V ratiometric output suit non-safety automotive applications such as manifold absolute pressure approximation in diesel retrofit kits or auxiliary pneumatic system monitoring. Its -40 °C to +125 °C operating range tolerates under-hood temperatures when thermally mounted, and the DIP package is robust against vibration in off-highway or stationary industrial vehicles. For production automotive programs, request AEC-Q100 screened variants from the manufacturer.

Zusammenfassung der empfohlenen Produkte

ADS1256 24-bit delta-sigma ADC for high-resolution pressure acquisition Verwendet in: Medical Patient Monitoring - Blood Pressure REF5030 Low-drift 5 V voltage reference for ratiometric ADC front-end Verwendet in: Medical Patient Monitoring - Blood Pressure XTR115UA 4-20 mA current loop transmitter for sensor output Verwendet in: Industrial Process Control TL074 Quad op-amp for sensor signal conditioning Verwendet in: Industrial Process Control STM32F103 ARM Cortex-M3 MCU with 12-bit ADC for closed-loop control Verwendet in: Pump and Motor Pressure Feedback IRF540N Power MOSFET for motor switching stage Verwendet in: Pump and Motor Pressure Feedback MAX31865 Industrial sensor interface chip Verwendet in: HVAC Pressure Switching STM8S003 Low-cost 8-bit MCU for HVAC sensor node Verwendet in: HVAC Pressure Switching ESP32 Wi-Fi/BLE MCU for wireless weather data uplink Verwendet in: Weather Station Barometric Measurement BME280 Companion humidity/temperature sensor for weather station Verwendet in: Weather Station Barometric Measurement MAX86150 Medical-grade signal processor companion Verwendet in: Respiratory Equipment / Ventilator Pressure Sensing ADuM3151 Digital isolator for medical safety isolation Verwendet in: Respiratory Equipment / Ventilator Pressure Sensing TLE7259-3GE Automotive LIN transceiver for sensor data reporting Verwendet in: Automotive Manifold Pressure Monitoring TLE4275G 5 V automotive voltage regulator Verwendet in: Automotive Manifold Pressure Monitoring
What is the operating pressure range of MPXV5100GC7U?
The MPXV5100GC7U operates from 0 to 100 kPa (0 to 14.5 PSI) in vented-gauge configuration. According to the STMicroelectronics datasheet for the MPX5100 family, the transducer is calibrated to deliver a linear 0.2 V to 4.7 V ratiometric output across that span when excited at 5.0 V, with a maximum overload pressure of 400 kPa. The vented reference path allows direct atmospheric compensation.
What supply voltage does MPXV5100GC7U require?
The MPXV5100GC7U operates from a single 5 V supply, with a permissible range of 4.75 V to 5.25 V per the manufacturer datasheet. Because the output is ratiometric, scaling the supply changes the output proportionally; designers commonly use a regulated 5 V rail referenced to the host ADC's reference for maximum accuracy, with a 100 nF decoupling capacitor placed close to the VCC pin.
What is the output voltage range of MPXV5100GC7U?
The output voltage spans 0.2 V (at 0 kPa) to 4.7 V (at 100 kPa) on a 5 V supply, giving approximately 45 mV/kPa of sensitivity. The 0.2 V offset is not zero to allow diagnostic distinction between a true zero-pressure reading and an open-circuit fault. Ratiometric operation means output at any pressure scales linearly with VCC within the specified supply range.
Is MPXV5100GC7U RoHS compliant?
Yes. The MPXV5100GC7U is RoHS compliant per the STMicroelectronics product page. Lead-free Pb-free plating is applied to the DIP leads, and the part meets the substance restrictions of Directive 2011/65/EU and its amendments. For medical or automotive designs, additional compliance verification against IEC 60601-1 or AEC-Q100 should be performed through ST's documentation channels.
What is the difference between MPXV5100GC7U and MPXV5100DP?
Both are members of the MPX5100 family with the same 0 to 100 kPa range and 5 V supply, but differ in port and reference configuration. The MPXV5100GC7U is a vented-gauge part in an 8-DIP top-port package; the MPXV5100DP is typically a differential dual-port variant. They are not drop-in compatible because the port geometry and pinout differ.
Can MPXV5100GC7U replace MPXV5004GC7U?
Both are STMicroelectronics gauge-pressure DIP sensors, but they are not drop-in replacements for each other. The MPXV5100GC7U offers 0 to 100 kPa range with 45 mV/kPa sensitivity, while the MPXV5004GC7U covers 0 to 3.92 kPa with much higher sensitivity (~1 V/kPa) for low-pressure applications. Switching between them requires recharacterizing the host ADC scaling and possibly changing the air-path geometry.
What is the best drop-in replacement for MPXV5100GC7U?
For a true drop-in footprint-compatible replacement in the same 8-DIP top-port form factor, the MPXV5100GP from STMicroelectronics is the closest same-package match (same 0 to 100 kPa, same 5 V supply, same port orientation but with a slightly different port style - confirm pinout before substituting). The MPX5100 (NXP legacy) shares the family heritage but uses a different lead frame - verify footprint before use.
Where can I download the MPXV5100GC7U datasheet PDF?
The official STMicroelectronics datasheet for MPXV5100GC7U is available as a PDF at https://www.st.com/resource/en/datasheet/mpxv5100gc7.pdf (per the manufacturer's product page). The document covers absolute maximum ratings, transfer function, temperature compensation, mechanical drawings, and the recommended PCB layout. Legacy NXP-branded copies (17 and 20 pages) also circulate on third-party datasheet portals.
What is the pinout of MPXV5100GC7U?
The MPXV5100GC7U uses an 8-DIP package with the standard MPX5100 family pinout: pins 1 to 4 are typically no-connect on the gauge-vented variant, pin 5 is GND, pin 6 is VCC (5 V), pin 7 is VOUT (analog ratiometric), and pin 8 is no-connect. Always confirm against the device marking and the manufacturer pinout diagram in the datasheet before board bring-up, because minor revisions exist across MPX5100 family members.
What is the price of MPXV5100GC7U in 1000-piece quantity?
The MPXV5100GC7U is budgeted at approximately $11.05 USD per unit at 1000-piece quantity, per the NXP/Octopart distributor listing (price information as of 2026-10-15). At lower volumes (cut tape / tube), the 1-piece price is roughly $13.50 USD. Volume discounts deepen at higher quantities; contact franchised distributors for current spot quotes and lead times.
Is MPXV5100GC7U in stock and what is the lead time?
Based on 2026-10-15 distributor data, the MPXV5100GC7U ships from stock at major franchised distributors such as DigiKey in tube packaging. Lead time for large orders above 1,200 units is typically 4 to 8 weeks; allocation is rare for the standard MPX5100 family. For confirmed availability and quotation, request a fresh quote from a franchised distributor before placing production orders.
What is the difference between MPXV5100GC7U and MPXV7002GC6U?
The MPXV5100GC7U measures 0 to 100 kPa gauge with 45 mV/kPa sensitivity for high-pressure applications. The MPXV7002GC6U is a differential part covering -2 to +2 kPa for very low-pressure airflow sensing (e.g., HVAC, ventilator flow). They share heritage but have different ranges, port configurations, and pinout assignments, so they are not drop-in replacements.
When should I choose MPXV5100GC7U over a lower-range MPX sensor?
Choose the MPXV5100GC7U when your application requires measurement of pressures up to 100 kPa (14.5 PSI), such as patient monitoring blood-pressure cuffs or industrial process control. Choose lower-range parts like the MPXV5004GC7U (3.92 kPa) or MPXV7002 (-2 to +2 kPa) when measuring small differential pressures such as airflow or water-column level; the higher 45 mV/kPa sensitivity of the MPXV5100 does not help when the signal you need to resolve is in the kPa range with high precision.
Is MPXV5100GC7U suitable for medical patient monitoring?
Yes. The MPXV5100GC7U is widely used in medical patient monitoring designs including non-invasive blood-pressure (NIBP) measurement and respiratory pressure sensing. Its 0 to 100 kPa range covers both systolic and cuff pressures, the ratiometric 5 V analog output interfaces directly to medical-grade ADCs, and STMicroelectronics provides the technical documentation necessary for IEC 60601-1 design reviews. Verify final compliance at the system level rather than rely on part-level certification.
How accurate is the MPXV5100GC7U analog output?
The MPXV5100GC7U is specified at 1.5% accuracy over the 0 °C to 85 °C temperature range when driven from a 5.0 V reference. End-to-end accuracy depends on the host ADC resolution and reference stability - pairing it with a 12-bit or 14-bit ADC and a low-drift voltage reference typically resolves pressures to within 0.1 kPa. For tighter system accuracy, perform a single-point calibration in software to remove offset error after assembly.

Technische Referenzdaten für MPXV5100GC7U – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPXV5100GC7U when you need a calibrated, vented-gauge pressure sensor in a vertical top-port 8-DIP package and your application measures in the 0 to 100 kPa range (medical NIBP cuffs, ventilator circuits, industrial process lines, HVAC static-pressure taps, and pump feedback). For low-pressure differential airflow below 4 kPa, choose the MPXV5004GC7U (1 V/kPa sensitivity) or MPXV7002 (-2 to +2 kPa) instead. When you need a horizontal port orientation, switch to the MPXV5100GP. For untrimmed lower-cost production, the MPXV5100G (without factory trim) lets you handle calibration in firmware. The MPX5100G from NXP legacy datasheets is functionally similar but uses older documentation - prefer the STMicroelectronics MPXV5100 family for new designs.

Vergleich mit Alternativen

Parameter Dieses Produkt MPXV5100GP MPX5100DP MPXV5100GC6U MPXV5100G MPXV5100GC7T1 MPX5100G
Brand STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics NXP Semiconductors
Package 8-DIP top port (0.550") 8-DIP top port - same family 8-DIP (DIP) - same 8-DIP (case 1317-01) - same 8-DIP top port - same 8-DIP top port - same 8-DIP (MPX family) - same
Pressure Type Vented Gauge Vented Gauge Differential Vented Gauge Vented Gauge Vented Gauge Gauge
Operating Pressure Range 0 to 100 kPa 0 to 100 kPa 0 to 100 kPa 0 to 100 kPa 0 to 100 kPa 0 to 100 kPa 0 to 100 kPa
Supply Voltage 5 V (4.75 V to 5.25 V) 5 V 5 V 5 V 5 V 5 V 5 V
Output Voltage Range 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Sensitivity 45 mV/kPa 45 mV/kPa 45 mV/kPa 45 mV/kPa 45 mV/kPa 45 mV/kPa 45 mV/kPa
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C
Response Time 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms 1.0 ms

Wichtigste Unterscheidungsmerkmale

  • Same vented-gauge 8-DIP top-port footprint across the family (vs. MPXV5100DP)
  • On-chip calibration for 1.5% accuracy without external trim (vs. MPXV5100G)
  • Vertical top port simplifies tube routing in stacked enclosures (vs. MPXV5100GP)
  • STMicroelectronics part-number and current datasheet chain (vs. MPX5100G (NXP legacy))

Designhinweise

The MPXV5100GC7U requires a clean regulated 5 V supply; place a 100 nF ceramic capacitor (X7R) as close as possible to pin 6 (VCC) and add a bulk 10 µF electrolytic or tantalum cap within 25 mm. Because the output is ratiometric to VCC, the supply regulator tolerance directly multiplies into the pressure reading accuracy - prefer a 1% regulator (or share the ADC reference rail) to avoid degrading the datasheet's 1.5% accuracy figure.

Route the analog output trace over a continuous ground plane and keep it away from switching nodes or high-current traces. Add a small RC low-pass filter (1 kΩ + 100 nF, fc ≈ 1.6 kHz) near the host ADC if high-frequency noise from motor drives or relays is present; this also limits aliasing of the sensor's 1 ms response on slower ADCs.

Estimated: Total uncalibrated error can exceed 5% if the host ADC's reference is not shared with the sensor supply. Always derive ADC VREF from the same 5 V rail that powers the sensor (using a low-noise buffer if needed) to preserve ratiometric accuracy. Also avoid kinking or restricting the vertical top port tube during assembly - a constricted port causes zero-shift errors that look like offset drift over temperature.

The 1.5% accuracy specification covers 0 °C to 85 °C; outside that range, expect additional temperature drift. For outdoor installations, mount the sensor away from direct sunlight or use a thermal shield, and verify that the vented-gauge reference path is not blocked by condensation - the part relies on the side vent to maintain atmospheric equilibrium.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS-compliant per STMicroelectronics product page. Lead-free DIP plating. Not AEC-Q100 qualified for automotive safety-critical applications - consult ST for automotive-grade variants. Halogen-free status was not directly stated in the verified web data; treat as unknown.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPXV5100GC7U MPXV5100GC7U datasheet STMicroelectronics MPXV5100GC7U 100 kPa gauge pressure sensor 5V 8-DIP top port pressure transducer MPXV5100GC7U medical NIBP pressure sensor MPXV5100GC7U vs MPXV5100DP MPXV5100GC7U drop-in replacement MPXV5100GC7U buy price 1000 pieces what is the output voltage of MPXV5100GC7U MPXV5100GC7U pinout 8-DIP vented gauge pressure sensor industrial MPX5100 family NXP equivalent cross reference MPXV5100GC7U RoHS compliance piezoresistive pressure transducer analog output

Verwandte Bauteile & Begriffe

STMicroelectronics MPXV5100GC7U MPXV5100GP MPX5100DP MPXV5100GC6U MPXV5100G MPXV5100GC7T1 MPX5100G NXP Semiconductors pressure sensor piezoresistive transducer vented gauge MEMS sensor analog ratiometric output DIP-8 through-hole package RoHS compliance AEC-Q100 medical NIBP ventilator pressure HVAC static pressure 0 to 100 kPa 45 mV/kPa sensitivity REACH compliance
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen