NXP Semiconductors

MPXV7007GC6U - ±7kPa Compound Pressure Sensor 5V SOP-8 | NXP

Teilenummer: MPXV7007GC6U ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
5.0 V (typical) Vdss 7 mA (typical) Id 8-SMD, Gull Wing, Top Port (SOP-8) Package
Ab $14.1 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $25.34 $25,34
10 $22.8 $228,00
100 $19.2 $1.920,00
500 $16.4 $8.200,00
1.000 $14.1 $14.100,00
ℹ️ Alle Preise sind in USD

MPXV7007GC6U Übersicht

The NXP MPXV7007GC6U is an integrated silicon piezoresistive pressure transducer that provides a calibrated, temperature-compensated analog output proportional to applied pressure. It measures compound pressure from -7 kPa to +7 kPa (about -1.02 to +1.02 PSI), operates from a single 5 V supply, and delivers a ratiometric analog output of 0.5 V to 4.5 V. The device is housed in a Small Outline Package (SOP-8, surface-mount, top port) measuring 11.4 x 8.1 x 6.4 mm with an integrated axial pressure port that accepts 3.17 mm (1/8 in) tubing.

A pressure sensor (also called a pressure transducer) is a device that converts an applied pneumatic or hydraulic pressure into a measurable electrical signal. Within the sensor taxonomy, the MPXV7007GC6U belongs to the MEMS piezoresistive family, where silicon strain gauges diffused into a diaphragm change resistance as the diaphragm flexes under pressure. These gauges are typically Wheatstone-bridge configured on-chip, with integrated signal conditioning (amplification, offset, and temperature compensation) so that the output is linear, calibrated, and ready to be read by a microcontroller ADC.

Key specifications include a pressure range of ±7 kPa with full-scale span of 4.0 V (typical), an operating temperature range of -40 °C to +125 °C, an accuracy of ±1.5 %VFSS (max) over the compensated range of 0 °C to +85 °C, a supply current of typically 7 mA, and ESD protection of 2 kV HBM on the pressure port and 200 V on the signal pins. The device uses on-chip temperature compensation and calibration, eliminating external trimming in production. The SOP-8 surface-mount package simplifies PCB assembly and is compatible with standard SMD pick-and-place lines.

Typical applications include HVAC variable-air-volume (VAV) controllers, medical respiratory instruments (spirometers, ventilators), industrial process control, altitude and weather-station instrumentation, and consumer appliances such as washing-machine water-level monitors. The compound (-7 to +7 kPa) range is particularly valuable for measuring both vacuum and positive pressure relative to atmospheric reference, enabling bidirectional flow sensing across fans, and filter differential-pressure monitoring in ventilation ducts. When designing with this device, place a 0.1 uF decoupling capacitor close to the supply pin, keep the pressure-port tubing short to minimize pneumatic resonance, and protect the port from condensation and direct water exposure using a barrier membrane when needed.

Drop-in-Alternativen für MPXV7007GC6U – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPXV7007GC6U (gleiche Bauform und Footprint) – abweichend in Supply Voltage, Output Voltage Range, Operating Pressure Range, Operating Temperature, Pressure Type.

NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Operating Pressure Range: -7 kPa to +7 kPa
Pressure Type: Differential
Vergleichen mit MPXV7007GC6U →
STMicroelectronics
Supply Voltage: 4.5 V to 5.5 V (5 V typical)
Output Voltage Range: 0.5 V to 4.5 V at 5 V Vcc
Operating Pressure Range: ±7 kPa (±1.02 PSI)
Vergleichen mit MPXV7007GC6U →
NXP Semiconductors
Supply Voltage: 5 V typical (ratiometric output)
Output Voltage Range: 0.2 V to 4.7 V
Operating Pressure Range: ±3.63 PSI (±25 kPa)
Vergleichen mit MPXV7007GC6U →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPXV7007GC6T1

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port (SOP-8)
identical SOP-8 top-port, same -7/+7 kPa compound range; tape-and-reel packaging variant

📋 Referenzalternative (nicht im Katalog)

MPXV7007GC6

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port (SOP-8)
identical -7/+7 kPa compound range and SOP-8 top-port; ST/legacy Freescale product variant

📋 Referenzalternative (nicht im Katalog)

MPXV7002GC6T1

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port (SOP-8)
narrower compound range -2/+2 kPa (about -71% nominal); same SOP-8 top-port package

📋 Referenzalternative (nicht im Katalog)

MPXV7007GC6U Grenzwerte & elektrische Eigenschaften

Product Type Integrated silicon pressure sensor
Manufacturer NXP Semiconductors
Pressure Range -7 kPa to +7 kPa (compound, ±1.02 PSI)
Operating Pressure - Max +7 kPa
Operating Pressure - Min -7 kPa
Versorgungsspannung 5.0 V (typical)
Versorgungsstrom 7 mA (typical)
Ausgangstyp Analog, ratiometric
Ausgangsspannungsbereich 0.5 V to 4.5 V
Output Span 4.0 V (typical, VFS - Voffset)
Accuracy ±1.5 %VFSS (max over compensated range)
Betriebstemperatur -40 °C to +125 °C
Compensated Temperature 0 °C to +85 °C
Port Type Axial, top port, accepts 3.17 mm (1/8 in) tube
Gehäuse 8-SMD, Gull Wing, Top Port (SOP-8)
Package Dimensions 11.4 mm x 8.1 mm x 6.4 mm
Technology MEMS piezoresistive, Wheatstone-bridge on-chip
Signal Conditioning On-chip amplifier, temperature compensation, calibration
ESD Protection (Port) 2 kV HBM
ESD Protection (Signal Pins) 200 V HBM
Montageart Surface Mount
RoHS-Status Compliant
Lead-Free Yes

MPXV7007GC6U Pin-Konfiguration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 Vout — Analog ratiometric output (0.5 V to 4.5 V)
Pin 2 GND — Ground reference
Pin 3 VCC — +5 V supply
Pin 4 VCC — +5 V supply (tie to pin 3)
Pin 5 GND — Ground (tie to pin 2)
Pin 6 NC — Not connected (no internal bond)
Pin 7 NC — Not connected (no internal bond)
Pin 8 NC — Not connected (no internal bond)

Typische Anwendungen

MPXV7007GC6U ist geeignet für 6 Anwendungs: HVAC Variable Air Volume (VAV) Control, Medical Respiratory / Spirometer Sensing, Filter Differential Pressure Monitoring, Industrial Process Vacuum Monitoring, Consumer Appliance Water-Level Sensing, Barometric and Altitude Instrumentation.

🏭

HVAC Variable Air Volume (VAV) Control

The MPXV7007GC6U is widely deployed in commercial-building HVAC variable-air-volume (VAV) damper controllers, where the bidirectional ±7 kPa range directly measures duct airflow differential. Its compound sensing capability allows detection of both pressure drop across filters (vacuum) and supply-side positive pressure, enabling a single sensor to monitor two pneumatic domains. The 5 V ratiometric output feeds a standard 10-bit or 12-bit microcontroller ADC, and the integrated axial port simplifies duct tap installation with 3.17 mm tubing.

💊

Medical Respiratory / Spirometer Sensing

In medical respiratory equipment such as spirometers, ventilators, and CPAP/BiPAP machines, the MPXV7007GC6U measures pressure swings across the breathing circuit with high linearity (±1.5 %VFSS) and stable 0 °C to +85 °C temperature behavior. The compound ±7 kPa window is wide enough to capture peak inspiratory and expiratory pressure drops without saturation. The on-chip calibration eliminates the trim step that hospital-grade OEMs would otherwise have to perform on every board, accelerating time-to-market for FDA-cleared devices.

🏭

Filter Differential Pressure Monitoring

The MPXV7007GC6U provides reliable across-filter vacuum in HEPA-filter and dust-collector differential-pressure transmitters. The bidirectional range yields a measurable voltage delta as the filter loads with particulates and the upstream-to-downstream pressure drop grows toward -7 kPa. Maintenance personnel can therefore track clogging trends from a calibrated 0.5 to 4.5 V output without recalibration. The SOP-8 SMD package simplifies mounting inside the filter-housing electronics enclosure.

🏭

Industrial Process Vacuum Monitoring

In industrial vacuum-pump and pick-and-place suction monitoring, the MPXV7007GC6U converts the pneumatic vacuum applied to a suction nozzle into a calibrated analog voltage readable by a 5 V PLC or microcontroller. The ±7 kPa compound range covers both atmospheric (0 V = 0 kPa = ambient) and full-vacuum operating points. The 5 V supply and small SMD package simplify integration into modular industrial sensor heads. ESD-withstand of 2 kV on the port protects against static-charge-induced failure in factory environments.

🏭

Consumer Appliance Water-Level Sensing

Consumer washing machines and dishwashers use the MPXV7007GC6U for water-level and air-pressure-trap differential-pressure measurement. The pressure chamber is sealed against the drain trap, and the head pressure of water inside the chamber is detected via the SOP-8 axial port. The integrated calibration removes per-board factory trim, reducing assembly cost. The 5 V ratiometric output feeds directly into the appliance microcontroller's ADC, which uses factory-stored compensation to compute water volume.

🌐

Barometric and Altitude Instrumentation

Although primarily a compound sensor, the MPXV7007GC6U can be used for low-resolution barometric and altitude-sensing applications where ±7 kPa is sufficient for indoor weather stations or HVAC outdoor-air measurement. The 0 °C to +85 °C compensated range covers most outdoor enclosures. The SOP-8 surface-mount footprint simplifies integration into compact weather-station PCBs, and the ratiometric output drives an ADC without requiring a precision voltage reference.

Zusammenfassung der empfohlenen Produkte

MPXV7007GC6T1 Tape-and-reel variant of same family Verwendet in: HVAC Variable Air Volume (VAV) Control, Industrial Process Vacuum Monitoring MPXV7002GC6T1 Narrower-range variant for finer-resolution flow sensing Verwendet in: HVAC Variable Air Volume (VAV) Control, Medical Respiratory / Spirometer Sensing MPXV4115VC6U STMicroelectronics Verwendet in: Medical Respiratory / Spirometer Sensing, Barometric and Altitude Instrumentation MPXV7007GC6 Drop-in alternative Verwendet in: Filter Differential Pressure Monitoring MPXV4006GC6T1 STMicroelectronics Verwendet in: Consumer Appliance Water-Level Sensing
What is the pressure range of MPXV7007GC6U?
The MPXV7007GC6U operates over a compound pressure range of -7 kPa to +7 kPa (approximately -1.02 to +1.02 PSI), making it a compound sensor that measures both vacuum (relative to ambient) and positive gauge pressure. According to the NXP product page, this bidirectional range is well suited for HVAC airflow and filter-monitoring applications where pressure can swing above and below atmospheric reference.
What is the output voltage of MPXV7007GC6U?
The MPXV7007GC6U provides a ratiometric analog output from 0.5 V to 4.5 V at 5 V supply, with 0.5 V representing -7 kPa and 4.5 V representing +7 kPa. The transfer function is linear with a typical full-scale span of 4.0 V. The output is designed to drive a 5 V microcontroller ADC input directly.
What is the supply voltage and current of MPXV7007GC6U?
The MPXV7007GC6U operates from a single 5.0 V DC supply with a typical operating current of 7 mA. The output is ratiometric, meaning the output voltage scales with supply voltage, so a stable 5 V reference (or accurate ADC reference) is required for absolute pressure readings. Operating beyond 5.25 V is not recommended.
What is the accuracy of MPXV7007GC6U?
The MPXV7007GC6U is factory-trimmed to ±1.5 %VFSS (max) over its compensated temperature range of 0 °C to +85 °C. Accuracy is preserved without external calibration because the silicon die is laser-trimmed during production. For applications outside the compensated range, additional error may accumulate toward the -40 °C and +125 °C operating limits.
What package does MPXV7007GC6U come in?
The MPXV7007GC6U is supplied in an 8-pin Small Outline Package (SOP-8) with gull-wing terminations and an integrated top-mounted axial pressure port. The package measures 11.4 mm x 8.1 mm x 6.4 mm and accepts 3.17 mm (1/8 in) flexible tubing. The SOP-8 SMD format supports standard pick-and-place assembly.
What is the difference between MPXV7007GC6U and MPXV4006GC6T1?
The MPXV7007GC6U is a compound sensor measuring -7 kPa to +7 kPa with a 4.0 V output span, while the MPXV4006GC6T1 is a vented-gauge sensor measuring 0 to +6 kPa with a 4.5 V output span. The MPXV7007GC6U is designed for bidirectional flow and HVAC applications; the MPXV4006GC6T1 suits positive-pressure-only measurements such as barometric or weather-station work.
Is MPXV7007GC6U suitable for medical respiratory devices?
Yes, the MPXV7007GC6U is well suited for medical respiratory instruments such as spirometers, ventilators, and CPAP/BiPAP airflow monitors because of its compound ±7 kPa range, 1 %-class linearity, on-chip temperature compensation, and fast response. The SOP-8 axial port accepts standard respiratory tubing. This medical application is a primary target use of the MPXV7007 family.
Where can I download the MPXV7007GC6U datasheet PDF?
The MPXV7007GC6U datasheet PDF is available for download from the NXP product page at https://www.nxp.com/part/MPXV7007GC6U. The 19-page document includes pinout, pressure-port dimensions, electrical characteristics, application circuits, and soldering recommendations. The PDF is also mirrored on Alldatasheet and Digchip for archival access.
What is the pinout of MPXV7007GC6U?
The MPXV7007GC6U SOP-8 pinout is: pin 1 = Vout, pin 2 = GND, pin 3 = VCC (+5 V), pin 4 = VCC (+5 V), pin 5 = GND, pin 6 = N/C, pin 7 = N/C, pin 8 = N/C. Pin numbers are referenced to the package marking as shown in the datasheet top-port drawing. The two VCC and two GND pins should each be tied together for lowest supply impedance.
What is the price of MPXV7007GC6U in 100-piece quantity?
The MPXV7007GC6U lists at approximately $25.34 per unit at qty 1, dropping to roughly $19.20 per unit at qty 100 and $14.10 per unit at qty 1000, as of 2026-10-15. Pricing varies by reel orientation and distributor; LCSC Electronics lists a 100-piece unit price of about $25.34, while larger reels at authorized distributors are typically 40 to 50 percent below the qty-1 price.
What is the lead time for MPXV7007GC6U?
Lead time for the MPXV7007GC6U at authorized distributors is typically 8 to 14 weeks from NXP, with distributor in-stock inventory turning over several days when available. NXP originally manufactured the part under the Freescale Semiconductor product line before the merger. For urgent orders, distributors such as DigiKey and Mouser frequently maintain small buffer stock.
What are the best drop-in alternatives for MPXV7007GC6U?
The best drop-in alternatives for the MPXV7007GC6U are MPXV7007GC6T1 (same -7/+7 kPa range, identical SOP-8 top-port footprint, tape-and-reel packaging variant) and MPXV7007GC6 (similar SOP-8 top-port footprint, same NXP product family). Both share the same pinout and supply-voltage characteristics as the MPXV7007GC6U. Pin-compatible second-source equivalents should be verified against the NXP datasheet pinout before PCB layout.
What is the best STMicroelectronics equivalent for MPXV7007GC6U?
The best STMicroelectronics equivalent for the MPXV7007GC6U is the ST MPXV7007GC6, which shares the same -7/+7 kPa compound range, the SOP-8 top-port footprint, and the same NXP-origin pinout. This is because the MPXV7007 series was originally developed by Freescale Semiconductor and migrated through both ST and NXP product lines. Verified parametric data should be re-checked against the latest ST datasheet before substitution.
What is the difference between MPXV7007GC6U and MPXV7002GC6T1?
The MPXV7007GC6U measures -7 to +7 kPa compound pressure, while the MPXV7002GC6T1 measures -2 to +2 kPa, a much narrower compound range useful for finer-resolution medical respiration measurements. Both share the same SOP-8 top-port package and 5 V supply, but the full-scale span differs (4.0 V vs ~4.0 V over a smaller pressure range, so resolution per MPa is greater for the 7002). Choose the 7007 for HVAC airflow, the 7002 for high-resolution spirometry.
What can replace MPXV7007GC6U in a pressure-sensing design?
MPXV7007GC6U replacements should match three parameters: compound -7 to +7 kPa pressure range, 5 V ratiometric analog output, and SOP-8 top-port axial package. Within the NXP family, the MPXV7007GC6T1 and MPXV7007GC6 share the same footprint. For higher resolution at the same range, consider the MPXV7002GC6T1 (narrower range, same package). Cross-brand alternatives are limited because the port geometry is specific to this NXP family.
How does the MPXV7007GC6U compare with MPXV4115VC6U?
The MPXV7007GC6U measures compound -7/+7 kPa at ±1.5 %VFSS accuracy, while the MPXV4115VC6U measures absolute pressure up to 115 kPa (about 16.7 PSI) with a similar analog output. They serve different application domains: the 7007 suits bidirectional airflow and HVAC, while the 4115 suits barometric or weather-station absolute-pressure measurement. Pinout differs between the two parts despite both being in the MPXV portfolio.

Technische Referenzdaten für MPXV7007GC6U – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPXV7007GC6U when you need bidirectional ±7 kPa compound pressure sensing in a single SOP-8 SMD package with on-chip calibration - especially for HVAC VAV, medical respiratory, or filter differential-pressure applications. Choose the MPXV7007GC6T1 if you need a tape-and-reel SMT-ready reel format with identical electrical performance. Choose the MPXV7002GC6T1 for higher-resolution flow sensing in medical spirometry. Choose the MPXV4006GC6T1 for positive-only gauge pressure below 6 kPa. Choose the MPXV4115VC6U for absolute-pressure barometric work up to 115 kPa. The SOP-8 top-port footprint is consistent across all these MPXV7007/4006/7002 family variants, allowing common PCB layouts.

Vergleich mit Alternativen

Parameter Dieses Produkt MPXV7007GC6T1 MPXV7007GC6 MPXV7002GC6T1
Brand NXP Semiconductors NXP Semiconductors STMicroelectronics (legacy Freescale / NXP) NXP Semiconductors
Package 8-SMD, Gull Wing, Top Port (SOP-8) 8-SMD, Gull Wing, Top Port (SOP-8) - same 8-SMD, Gull Wing, Top Port (SOP-8) - same 8-SMD, Gull Wing, Top Port (SOP-8) - same
Pressure Range -7 kPa to +7 kPa -7 kPa to +7 kPa -7 kPa to +7 kPa -2 kPa to +2 kPa
Pressure Type Compound Compound Compound Compound
Supply Voltage 5.0 V 5.0 V 5.0 V 5.0 V
Output Voltage Range 0.5 V to 4.5 V 0.5 V to 4.5 V 0.5 V to 4.5 V 0.5 V to 4.5 V
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C -40 °C to +125 °C
Accuracy (max) ±1.5 %VFSS ±1.5 %VFSS ±1.5 %VFSS ±1.5 %VFSS
Packaging Variant Tube Tape & Reel Tube / Tray Tape & Reel

Wichtigste Unterscheidungsmerkmale

  • Bidirectional compound ±7 kPa range in single SOP-8 (vs. MPXV4006GC6T1)
  • Industry-standard axial top port with 3.17 mm tubing compatibility (vs. MPXV4115VC6U)
  • Wider pressure window vs MPXV7002 family (vs. MPXV7002GC6T1)

Designhinweise

Estimated: at 5 V supply and 7 mA typical supply current, the MPXV7007GC6U draws about 35 mW of continuous power. The two VCC pins (3 and 4) and two GND pins (2 and 5) must each be tied together on the PCB. Place a 0.1 uF ceramic decoupling capacitor within 5 mm of the VCC pins; an additional 1 uF bulk capacitor improves immunity against digital supply noise.

Route analog output traces away from switching power and high-current digital traces to prevent noise coupling into the ratiometric ADC reading. Use a ground plane under the sensor footprint to shield the silicon die from PCB noise. The axial pressure port should be mounted at the highest point of the PCB if condensate accumulation is a concern.

Do not apply pressure beyond -7 to +7 kPa; bursts can rupture the silicon diaphragm and permanently damage the sensor. Avoid water ingress into the axial port - install a barrier membrane such as Gore-Tex vented membrane if moisture exposure is possible. The output is ratiometric, meaning an unstable 5 V supply becomes an unstable pressure reading. A clean 5 V LDO such as a TPS7A4533 or AP2112 is recommended upstream.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS and REACH status per the NXP product page. Halogen-free status is not explicitly stated in the verified web data; assumed compliant per NXP standard product family policy but [DATA_NEEDED: halogen-free declaration] if certification is critical.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPXV7007GC6U MPXV7007GC6U datasheet NXP MPXV7007GC6U ±7 kPa compound pressure sensor SOP-8 axial port pressure sensor 3.17mm tube MPXV7007GC6U HVAC VAV controller MPXV7007GC6U spirometer respiratory MPXV7007GC6U vs MPXV4006GC6T1 MPXV7007GC6U drop-in replacement MPXV7007GC6U buy online price what is the pressure range of MPXV7007GC6U MPXV7007GC6U pinout SOP-8 low cost MEMS pressure sensor 5V analog output

Verwandte Bauteile & Begriffe

NXP Semiconductors MPXV7007GC6U MPXV7007GC6T1 MPXV7007GC6 MPXV7002GC6T1 MPXV4006GC6T1 MPXV4115VC6U pressure sensor pressure transducer MEMS piezoresistive transducer Wheatstone bridge compound pressure gauge pressure absolute pressure SOP-8 8-SMD gull wing top port axial port ratiometric output signal conditioning temperature compensation RoHS REACH HVAC VAV controller spirometer ventilator filter differential pressure
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen