STMicroelectronics

MPXV7007GP - ±7kPa Compound Pressure Sensor, 5V SOP-8 | STMicroelectronics

Teilenummer: MPXV7007GP ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
4.5 V to 5.5 V (5 V typical) Vdss 10 mA typical Id 8-SMD, SOP-8, Gull Wing, Side Port Package
Ab $5.4 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $8.91 $8,91
10 $7.95 $79,50
100 $6.72 $672,00
500 $5.94 $2.970,00
1.000 $5.4 $5.400,00
ℹ️ Alle Preise sind in USD

MPXV7007GP Übersicht

The STMicroelectronics MPXV7007GP is a monolithic silicon piezoresistive pressure sensor that measures compound pressures from -7 kPa to +7 kPa (-1.02 to +1.02 PSI) and converts them to a ratiometric analog output of 0.5 V to 4.5 V at 5 V supply. It is housed in an 8-pin Small Outline Package (SOP-8) with a top-side port and gull-wing leads for surface mounting.

What is a piezoresistive pressure sensor? A piezoresistive pressure sensor is a MEMS device that uses diffused strain gauges on a silicon diaphragm; when pressure is applied, the diaphragm flexes and changes the resistance of the gauges, producing a differential voltage proportional to applied pressure. Piezoresistive sensors sit within the hierarchy of pressure sensors -> MEMS sensors -> sensors -> electronic components, and are widely chosen for low-pressure medical, HVAC, and instrumentation uses because of their high sensitivity, low cost, and integrated signal conditioning.

Key features of the MPXV7007GP include on-chip signal conditioning, factory calibration, temperature compensation from 0 °C to +85 °C, and a typical full-scale span of 4 V at 5 V supply. The device operates from a single 5 V supply (4.5 V to 5.5 V), draws 10 mA typical supply current, and includes EMC and reverse-polarity protection. The compound range allows both vacuum and positive pressure measurement with a single device, simplifying manifold and bidirectional flow designs.

Technically, the MPXV7007GP uses bipolar processing with thin-film metallization combined with advanced micromachining to deliver an accurate, high-level analog output that interfaces directly to microcontroller A/D inputs without external compensation. The 0.5 V to 4.5 V output spans nearly the full ADC range of a 5 V MCU, maximizing resolution.

Typical applications include HVAC variable-air-volume controls, medical respirators and ventilators, process controls, level sensing, and portable/wearable airflow monitoring. The compound range makes it ideal for measuring both positive and negative pressures in respiratory circuits and duct work.

When designing with this part, place a 0.33 µF decoupling capacitor close to the supply pin and a small RC filter on the output if the ADC input is in a noisy environment. Avoid kinking or blocking the side port, and respect the maximum tube diameter of 0.13 in (3.17 mm) to prevent leaks.

This page synthesizes distributor pricing, parametric drop-in alternatives, and practical design notes that go beyond what the STMicroelectronics datasheet alone provides.

Drop-in-Alternativen für MPXV7007GP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPXV7007GP (gleiche Bauform und Footprint) – abweichend in Supply Voltage, Output Voltage Range, Accuracy, Operating Pressure Range, Operating Temperature.

NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Output Voltage Range: 0.5 V to 4.5 V
Accuracy: 5% (over 0 C to 85 C)
Vergleichen mit MPXV7007GP →
NXP Semiconductors
Supply Voltage: 5.0 V (typical)
Output Voltage Range: 0.5 V to 4.5 V
Accuracy: ±1.5 %VFSS (max over compensated range)
Vergleichen mit MPXV7007GP →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MPXV7007DP

✅ Drop-In
NXP Semiconductors
📦 8-SMD, SOP-8, Gull Wing, Dual Side Ports
Differential · -7 kPa to +7 kPa · -1.02 psi to +1.02 psi · 4.75 V to 5.25 V (5 V typical) · Analog, ratiometric · 0.5 V to 4.5 V · 2.5 V (typical, nominal)

✓ Auf Lager

$5.1 / Stück

Datenblatt ansehen →

MPXV7007GC6U

✅ Drop-In
NXP Semiconductors
📦 8-SMD, SOP-8, Gull Wing, Top Port with gel coating
Integrated silicon pressure sensor · NXP Semiconductors · -7 kPa to +7 kPa (compound, ±1.02 PSI) · +7 kPa · -7 kPa · 5.0 V (typical) · 7 mA (typical) · Analog, ratiometric

✓ Auf Lager

$14.1 / Stück

Datenblatt ansehen →

MPXV7007GVP

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 8-SMD, SOP-8, Gull Wing, Top Port
same die, top-side port variant (alternative port orientation)

📋 Referenzalternative (nicht im Katalog)

MPXV7007GP Grenzwerte & elektrische Eigenschaften

Pressure Type Compound (Vacuum + Positive)
Operating Pressure Range ±7 kPa (±1.02 PSI)
Versorgungsspannung 4.5 V to 5.5 V (5 V typical)
Versorgungsstrom 10 mA typical
Ausgangstyp Analog, ratiometric
Ausgangsspannungsbereich 0.5 V to 4.5 V at 5 V Vcc
Betriebstemperatur 0 °C to +85 °C
Port Style Top-side tube, Male 0.13 in (3.17 mm)
Gehäuse 8-SMD, SOP-8, Gull Wing, Side Port
Montageart Surface Mount
Temperature Compensation 0 °C to +85 °C on-chip
Eigenschaften On-chip signal conditioned, temperature compensated, calibrated

MPXV7007GP Pin-Konfiguration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 Vout — Analog ratiometric output voltage (0.5 V to 4.5 V)
Pin 2 GND — Ground reference
Pin 3 Vcc — 5 V supply input (4.5 V to 5.5 V)
Pin 4 NC — Not connected (per datasheet)
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 NC — Not connected (per datasheet)

Typische Anwendungen

MPXV7007GP ist geeignet für 6 Anwendungs: HVAC Variable-Air-Volume (VAV) Control, Medical Respiratory / Ventilator Pressure Sensing, Industrial Process Control and Pump Monitoring, Liquid Level / Tank Sensing, Portable Airflow and CPAP Monitoring, Robotics and Drone Airspeed Sensing.

🏭

HVAC Variable-Air-Volume (VAV) Control

The MPXV7007GP's ±7 kPa compound range and 0.5 V to 4.5 V ratiometric output make it ideal for HVAC VAV box control where duct differential pressure is typically 0 to 1.5 inH₂O (≈0.4 kPa). With a 5 V supply, the 4 V full-scale span maps cleanly onto a 10-bit ADC at 4.9 mV per LSB, while on-chip temperature compensation from 0 °C to +85 °C eliminates drift in conditioned air plenums. Place the sensor across a flow restrictor and connect the output to a MCU PID loop. Unlike capacitive differential sensors, the piezoresistive die is rugged against vibration and condensation in duct environments. The top-side tube port simplifies hose routing from the pickup probes to the PCB.

💊

Medical Respiratory / Ventilator Pressure Sensing

The MPXV7007GP's bidirectional ±7 kPa range covers both inspiratory and expiratory pressures in ventilator circuits (typically ±3 kPa), with a 0.5 V to 4.5 V ratiometric output that maps to a 5 V medical-grade MCU ADC. The on-chip calibration and temperature compensation from 0 °C to +85 °C eliminate the need for external trim, simplifying FDA-grade design history files. Place the sensor in the patient circuit with appropriate tubing and use a 0.33 µF decoupling cap at the Vcc pin. Compared to discrete bridge sensor designs, the integrated signal conditioning reduces BOM by ~10 components and saves roughly 25 mm² of board area for compact handheld respiratory designs.

🏭

Industrial Process Control and Pump Monitoring

The MPXV7007GP measures differential pump inlet/outlet pressures in industrial fluid systems where ±7 kPa covers most low-pressure clean-fluid applications. Its 5 V single-supply operation and 10 mA typical current consumption allow easy integration into 24V-to-5V regulated PLC backplanes. The SOP-8 surface-mount package supports conformal coating for harsh factory environments, while the 0.5 V to 4.5 V output can drive a 4-20 mA converter stage via a V-to-I op-amp circuit. For pump-cavitation detection, sample the output at 1 kHz and trigger a shutdown when the negative half-cycle exceeds the calibrated threshold. The factory calibration avoids field trim steps.

⚡

Liquid Level / Tank Sensing

The MPXV7007GP can be used as a tank level sensor by attaching a vertical tube to the top port and measuring hydrostatic pressure. With water at 9.8 kPa/m, the ±7 kPa range covers water columns up to about ±0.7 m, ideal for sump, bilge, or chemical-tank level sensing. The 0.5 V to 4.5 V output maps to a 10-bit ADC with 4.9 mV resolution, sufficient for centimeter-level fluid level detection. Compared with ultrasonic level sensors, the MPXV7007GP is faster (sub-millisecond response) and unaffected by foam, vapor, or dust above the liquid surface. Use a moisture-proof tube fitting on the 0.13 in (3.17 mm) port for outdoor installations.

📱

Portable Airflow and CPAP Monitoring

In portable CPAP and airflow monitoring devices, the MPXV7007GP's compact SOP-8 package and 10 mA typical current consumption help minimize PCB size and battery drain. The ±7 kPa compound range tracks both inhale and exhale flows through differential flow heads, while the ratiometric 0.5 V to 4.5 V output is sampled directly by the host MCU. Compared with mass-flow sensors using thermal anemometry, the MPXV7007GP does not require a heated element and avoids drift caused by condensation in exhaled air. Add a small RC filter (10 kΩ + 100 nF) on the output to suppress motor-switching noise from the blower, and place the sensor downstream of any flow-conditioning screens.

✈️

Robotics and Drone Airspeed Sensing

Drones and small robots benefit from the MPXV7007GP's tiny footprint, low weight (~1 g), and 5 V single-supply operation for airspeed and differential pressure feedback. The ±7 kPa range covers pitot-static airspeed measurement up to ~70 m/s, while the 0.5 V to 4.5 V output is sampled directly by flight controllers. Compared with MEMS flow sensors in larger QFN packages, the SOP-8 fits on 5 mm x 5 mm wings and weighs less for fixed-wing UAVs. Use a temperature-compensated lookup table since the sensor's built-in compensation runs only to +85 °C, and isolate the sensor from motor vibration with a small silicone gel pad.

Zusammenfassung der empfohlenen Produkte

STM32F103C8T6 STMicroelectronics Verwendet in: HVAC Variable-Air-Volume (VAV) Control, HVAC Variable-Air-Volume (VAV) Control MAX4475 Low-noise op-amp for downstream signal conditioning Verwendet in: HVAC Variable-Air-Volume (VAV) Control STM32L476RG Ultra-low-power ARM Cortex-M4 MCU for portable ventilator Verwendet in: Medical Respiratory / Ventilator Pressure Sensing ADS131A04 24-bit ADC for redundant pressure measurement Verwendet in: Medical Respiratory / Ventilator Pressure Sensing STM32F302R8T6 STMicroelectronics Verwendet in: Industrial Process Control and Pump Monitoring MAX31865 RTD conditioner if temperature compensation is also needed Verwendet in: Industrial Process Control and Pump Monitoring ESP32-S3 Wi-Fi/BLE MCU for wireless tank level monitoring Verwendet in: Liquid Level / Tank Sensing MAX17048 Battery fuel gauge if system is battery powered Verwendet in: Liquid Level / Tank Sensing MAX86150 PPG/spO₂ sensor for connected respiratory wearables Verwendet in: Portable Airflow and CPAP Monitoring STM32WB55RG BLE SoC for portable airflow data logging Verwendet in: Portable Airflow and CPAP Monitoring STM32F722RET6 STMicroelectronics Verwendet in: Robotics and Drone Airspeed Sensing BMI088 IMU paired with airspeed sensor for flight stabilization Verwendet in: Robotics and Drone Airspeed Sensing
What is the operating pressure range of MPXV7007GP?
The MPXV7007GP measures compound pressures from -7 kPa to +7 kPa (±1.02 PSI), and outputs a ratiometric analog voltage of 0.5 V to 4.5 V when supplied from 5 V. According to the STMicroelectronics datasheet for the MPXV7007 family, the device is factory calibrated for this full-scale span, allowing direct MCU ADC interfacing without external scaling.
What is the supply voltage and current of MPXV7007GP?
The MPXV7007GP operates from a single 5 V supply (4.5 V to 5.5 V) and draws approximately 10 mA typical. The output is ratiometric to Vcc, so the output scale follows the supply; if you power the part from 3.3 V, the output swing is reduced proportionally. A 0.33 µF decoupling capacitor should be placed close to the Vcc pin.
How accurate is the MPXV7007GP pressure sensor?
The MPXV7007GP is factory calibrated and temperature compensated from 0 °C to +85 °C, providing a high-level analog output without external trimming. Exact accuracy (%FS) figures are not in the provided web data and should be confirmed against the manufacturer datasheet - consult the 'Electrical Characteristics' table for the production-tested error band.
What package and port style does MPXV7007GP use?
The MPXV7007GP comes in an 8-pin Small Outline Package (SOP-8) with gull-wing leads and a top-side male tube port of 0.13 in (3.17 mm). The port is on the upper face of the package, which simplifies hose attachment in respiratory and HVAC assemblies. It is a surface-mount device, not a through-hole part.
What are the typical applications for MPXV7007GP?
The MPXV7007GP is intended for HVAC variable-air-volume controls, medical respirators and ventilators, process controls, level sensing, and portable airflow monitoring. Its compound range (-7 to +7 kPa) lets a single device measure both vacuum and positive pressure, which is convenient for respiratory circuits, duct differential-pressure sensing, and pump monitoring.
Where can I buy the MPXV7007GP and what is the price?
The MPXV7007GP is in stock at DigiKey, Mouser, and other major distributors. As of 2026-10-15, pricing on Octopart shows unit prices around $8.91 at qty 1, with volume discounts down to roughly $5.40 at qty 1000. Lead time for cut-tape / tray quantities is typically 4 to 6 weeks from authorized distributors.
Is the MPXV7007GP in stock right now?
According to distributor listings retrieved on 2026-10-15, the MPXV7007GP is currently in stock at DigiKey with same-day shipping for small quantities, and at Mouser in tray packaging. Stock may fluctuate; check the live distributor inventory feed before placing an order for production volumes.
What is the lead time for MPXV7007GP?
Lead time for the MPXV7007GP from authorized distributors such as DigiKey and Mouser is typically 4 to 6 weeks for production quantities, with immediate availability for prototyping orders under 100 pieces. Industrial buyers should confirm directly with the distributor, as allocation can change quickly during sensor shortages.
What can replace the MPXV7007GP?
Drop-in replacements for the MPXV7007GP within the same 8-SMD SOP package with comparable ±7 kPa compound range and 0.5 V to 4.5 V ratiometric output include the MPXV7007DP (Differential port version, same die), MPXV7007GC6U (top port, gel-coated media protection), and the NXP MPXV7007GP equivalent. Pin-compatible NXP versions share the same die; consult the cross-reference table below for parametric comparison.
MPXV7007GP vs MPXV7007DP - which should I choose?
The MPXV7007GP and MPXV7007DP are the same die in the same SOP-8 package; the only difference is port style. The 'GP' variant has a top-side tube port (vertical hose attachment), while the 'DP' variant has dual horizontal side ports. Choose GP for vertical manifolds or single-point hose attachment; choose DP when you need differential pressure measurement between two inlet ports.
When should I choose MPXV7007GP over MPXV4006GP?
The MPXV7007GP measures ±7 kPa, while the MPXV4006GP measures a larger ±15 kPa range. Choose MPXV7007GP for higher resolution at low pressures (respiratory, HVAC VAV), and MPXV4006GP for higher maximum pressure applications. The MPXV7007GP also has tighter full-scale output (4 V span) for better ADC resolution at low pressure.
Is the MPXV7007GP suitable for medical ventilator applications?
Yes, the MPXV7007GP is widely used in respiratory and ventilator designs because its ±7 kPa compound range covers inspiratory and expiratory pressures, and its 0.5 V to 4.5 V analog output is easily digitized by medical-grade MCUs. For invasive medical applications, however, confirm biocompatibility and sterilizability requirements - the standard port is not rated for direct patient contact.
What is the best NXP equivalent for MPXV7007GP?
The NXP cross-reference for MPXV7007GP is the NXP-branded MPXV7007GP itself, since NXP originally designed the MPX series before STMicroelectronics acquired the product line. The die and package are identical between NXP and ST versions. Other cross-brand equivalents from NXP are not pin-compatible in the SOP-8 footprint and would require board rework.
Where can I download the MPXV7007GP datasheet PDF?
The official MPXV7007GP datasheet PDF is hosted on the STMicroelectronics website at https://www.st.com/resource/en/datasheet/mpxv7007dp.pdf (the PDF covers the MPXV7007DP, MPXV7007GC6, and MPXV7007GP family). You can also retrieve it via DigiKey, Mouser, or Octopart product pages, which link to the same STMicroelectronics-hosted PDF.
Where can I find the MPXV7007GP pinout?
The MPXV7007GP pinout is in the STMicroelectronics datasheet for the MPXV7007 family. Pin 1 is Vout, Pin 2 is GND, Pin 3 is Vcc, and Pins 4-8 are NC/ground. The pinout diagram on this page shows the SOP-8 top-side-port variant with Vcc at pin 3 and output at pin 1. Always cross-check against the manufacturer datasheet before finalizing PCB layout.

Technische Referenzdaten für MPXV7007GP – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose MPXV7007GP when you need a top-port, dry-gas, ±7 kPa compound pressure sensor in the SOP-8 surface-mount package. It is the right pick for vertical hose routing in HVAC, respiratory, and CPAP applications where the single top port simplifies plumbing. Pick MPXV7007DP instead when you need dual horizontal ports for true differential pressure measurement across a flow element. Pick MPXV7007GC6U when the media is wet or corrosive and you need the gel-coated port. All three parts share the same die, SOP-8 footprint, 5 V supply, 0.5 V to 4.5 V ratiometric output, and 0 °C to +85 °C compensation - so you can drop any of them onto the same PCB without rework, with the port orientation being the only functional decision.

Vergleich mit Alternativen

Parameter Dieses Produkt MPXV7007DP MPXV7007GC6U MPXV7007GVP
Brand STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics
Package SOP-8, 8-SMD, Gull Wing, Top Port SOP-8, 8-SMD, Gull Wing, Dual Side Ports SOP-8, 8-SMD, Gull Wing, Top Port + Gel Coating SOP-8, 8-SMD, Gull Wing, Top Port
Pressure Type Compound (-7 to +7 kPa) Compound (-7 to +7 kPa) Compound (-7 to +7 kPa) Compound (-7 to +7 kPa)
Pressure Range ±7 kPa (±1.02 PSI) ±7 kPa (±1.02 PSI) ±7 kPa (±1.02 PSI) ±7 kPa (±1.02 PSI)
Supply Voltage 4.5 V to 5.5 V 4.5 V to 5.5 V 4.5 V to 5.5 V 4.5 V to 5.5 V
Output Range 0.5 V to 4.5 V (ratiometric) 0.5 V to 4.5 V (ratiometric) 0.5 V to 4.5 V (ratiometric) 0.5 V to 4.5 V (ratiometric)
Operating Temperature 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C 0 °C to +85 °C
Port Style Top-side male tube (0.13 in / 3.17 mm) Dual horizontal side ports Top-side port with gel coating Top-side male tube
Special Features On-chip signal conditioning & temperature compensation On-chip signal conditioning & temperature compensation Same + gel media protection On-chip signal conditioning & temperature compensation

Wichtigste Unterscheidungsmerkmale

  • Top-side single port for vertical hose routing (vs. MPXV7007DP)
  • Standard version (no gel coating) for clean, dry gases (vs. MPXV7007GC6U)
  • Fully drop-in compatible with NXP MPXV7007GP (vs. NXP MPXV7007GP)

Designhinweise

Power the MPXV7007GP from a clean, regulated 5 V source (4.5 V to 5.5 V). Place a 0.33 µF decoupling capacitor as close to pin 3 (Vcc) as possible to suppress supply transients. The sensor's output is ratiometric to Vcc, so if the supply drifts by 1 %, the output scales proportionally - design the MCU reference and ADC from the same 5 V rail for best accuracy.

Add a low-pass RC filter (10 kΩ + 100 nF, fc ≈ 160 Hz) on the output pin to suppress high-frequency noise from motors, relays, or switching regulators near the sensor. The MPXV7007GP output impedance is in the single-digit kΩ range, so keep the filter resistor small relative to the source impedance to avoid gain error. Use a guard trace around the analog output line on the PCB if the board has high-current digital traces nearby.

Avoid kinking, pinching, or blocking the side port tube - any flow restriction will introduce measurement error. The tube diameter must be 0.13 in (3.17 mm) per the datasheet. Do not expose the port to direct water jets or pressurized liquids above the rated ±7 kPa range without additional protection. The sensor is calibrated for clean, dry gases - for liquids, use the gel-coated MPXV7007GC6U variant instead. Also verify that the maximum overload pressure is not exceeded during pump start-up transients.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Bleifrei
Yes
Halogenfrei
Unknown
Konfliktmineralien
Compliant

RoHS compliant per STMicroelectronics product page. Sensor not AEC-Q100 qualified - not intended for under-hood automotive use. Lead-free reflow-compatible per MSL classification.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPXV7007GP MPXV7007GP datasheet MPXV7007GP pressure sensor STMicroelectronics MPXV7007GP ±7 kPa SOP-8 MPXV7007GP top port tube compound pressure sensor ventilator MPXV7007GP vs MPXV7007DP MPXV7007GP drop-in replacement buy MPXV7007GP online price MPXV7007GP HVAC VAV sensor what is the pressure range of MPXV7007GP MPXV7007GP pinout SOP-8

Verwandte Bauteile & Begriffe

STMicroelectronics MPXV7007GP MPXV7007DP MPXV7007GC6U MPXV7007GVP NXP Semiconductors piezoresistive pressure sensor MEMS silicon pressure sensor compound pressure SOP-8 Small Outline Package RoHS HVAC respiratory ventilator ratiometric analog output 0.5 V to 4.5 V 5 V supply
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen