AD515AKH Descripción general

The Analog Devices AD515AKH is a precision, low-power, FET-input operational amplifier with a maximum input bias current of 150 fA, maximum quiescent current of 1.5 mA, and an 8-pin TO-99 metal-can package. The AD515AKH is the K-temperature-grade version of the AD515A family and is intended for electrometer, high-impedance sensor, instrumentation, and precision measurement applications.

An electrometer operational amplifier is a low-noise, high-input-impedance amplifier optimized for measuring very small currents and voltages without loading the source. In the component hierarchy, the AD515AKH is a precision operational amplifier, an analog amplifier IC, and a member of the broader analog and mixed-signal semiconductor category. Its FET input stage enables measurement systems to preserve signal integrity when connected to high-impedance transducers, photodiodes, chemical sensors, and other sources with source impedances in the gigaohm range.

Key features include a guaranteed maximum input bias current of 150 fA, low-power operation with a 0.6 mA typical quiescent current, and a maximum quiescent current of 1.5 mA. The AD515A family also provides laser-trimmed offset voltage, low offset drift, and low noise. These characteristics allow the AD515AKH to support stable dc measurements while avoiding excessive signal-source loading. Its precision architecture is particularly useful when measurement accuracy is governed more by input bias current and offset behavior than by high bandwidth.

The AD515AKH represents a monolithic successor to the original AD515 electrometer and can replace that earlier device in most applications. Compared with general-purpose bipolar-input operational amplifiers, the AD515A topology uses a FET input stage to reduce input bias current by many orders of magnitude. The K-grade AD515AKH is specified for a maximum bias current of 150 fA, while the L-grade AD515AL reaches 75 fA and the J-grade AD515AJ reaches 300 fA. This grading lets designers balance leakage limits, availability, and application requirements without changing the basic measurement architecture.

Typical uses include pH and ion-selective electrode interfaces, photodiode and optical-sensor amplifiers, high-impedance voltage dividers, capacitance sensing, laboratory instrumentation, battery and gas monitoring, and precision current-to-voltage converters. In each case, the amplifier is placed directly at the high-impedance input so that cable and board leakage, guarding, clean power, and stable reference grounding become as important as closed-loop resistor accuracy.

A critical design practice is to surround sensitive inputs with guarding and keep input traces short and clean. Although input bias current is limited to 150 fA, board contamination, moisture, flux residue, and adjacent high-impedance nodes can increase leakage substantially. Use a shielded or guarded PCB layout, clean conformal coating where environmental exposure is expected, and low-value feedback resistors when system bandwidth permits.

This page combines the manufacturer product description, verified distributor pricing, package details, cross-reference findings, and practical design guidance for engineers evaluating the AD515AKH. It also distinguishes pin-compatible family options from broader functional equivalents so that replacement decisions are based on electrical proximity rather than package similarity alone.

Alternativas directas para AD515AKH — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con AD515AKH (mismo factor de forma y huella) — difiere en Product Type, Amplifier Type, Input Offset Voltage, Maximum, Input Transistor Type.

Analog Devices
Product Type: Operational Amplifier
Input Offset Voltage, Maximum: 25 uV
Input Transistor Type: Bipolar
Analog Devices
Product Type: Precision operational amplifier
Amplifier Type: General-purpose precision amplifier
Comparar con AD515AKH →
Analog Devices
Amplifier Type: General-purpose operational amplifier
Input Offset Voltage, Maximum: 6000 uV

AD515ALH

✅ Sustitución directa ⚠️ Especificaciones sin verificar
📦 TO-99-8 metal can
Maximum input bias current is 75 fA versus 150 fA for AD515AKH, a 50% lower limit; AD515A family package and amplifier configuration are retained.

📋 Alternativa de referencia (no en el catálogo)

AD515AJH

✅ Sustitución directa
📦 TO-99-8 metal can
Maximum input bias current is 300 fA versus 150 fA for AD515AKH, a 100% higher limit; the AD515A family TO-99 configuration is retained.

📋 Alternativa de referencia (no en el catálogo)

AD517SH

✅ Sustitución directa
Analog Devices
📦 TO-99-8 metal can
Precision operational amplifier · Analog Devices · 75 uV · 0.25 MHz · 1 circuit · General-purpose precision amplifier · Laser trimmed · Monolithic

Consulte el precio

Ver hoja de datos →

AD510LH/+

✅ Sustitución directa
Analog Devices
📦 TO-99-8 metal can
Operational Amplifier · 1 circuit · General-purpose amplifier · 25 uV · Bipolar · TO-99-8 metal can · 8 pins · Through-hole

Consulte el precio

AD515AKH Valores máximos y características eléctricas

Product Type Monolithic precision, low-power FET-input electrometer operational amplifier
Maximum Input Bias Current 150 fA
Typical Quiescent Current 0.6 mA
Maximum Quiescent Current 1.5 mA
Offset Voltage 1.0 mV maximum
Number of Circuits 1 circuit
Input Transistor Type FET
Encapsulado TO-99-8 metal can
Número de pines 8 pins
Terminal Form Wire
Temperature Grade Commercial

Guía de configuración de pines de AD515AKH to-99-8 metal can

Configuración de pines para AD515AKH (encapsulado to-99-8 metal can). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.

Diagrama de patillaje del encapsulado to-99-8 metal can para AD515AKH

No hay datos detallados de patillaje disponibles para AD515AKH.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

AD515AKH es adecuado para 6 aplicacións: Electrochemical Sensor Interface, Photodiode Optical Measurement, Battery-Powered Precision Instrument, Chemical and Gas Sensor Monitoring, Capacitance and Charge Sensing, High-Impedance Voltage Divider.

🧩

Electrochemical Sensor Interface

The AD515AKH is well suited to pH electrodes, ion-selective electrodes, and other electrochemical sensors whose effective source impedance can be extremely high. Its 150 fA maximum input bias current limits the current drawn from the sensor, while the 0.6 mA typical quiescent current supports compact battery-powered analyzers. Place the amplifier close to the sensor, surround the input with guarding, and use low-leakage board materials. Feedback resistors should be selected to balance input-generated Johnson noise against the bandwidth required by the electrode’s response time.

📷

Photodiode Optical Measurement

AD515AKH can amplify the small photocurrent generated by a photodiode without imposing a large input-bias load on the source. The 150 fA maximum bias current is particularly useful for wide-area or reverse-biased detectors operating at low light levels, while the maximum 1.5 mA supply current keeps instrumentation power manageable. Use the amplifier in a transimpedance configuration, keep the summing node compact, and provide guard rings around both the input and feedback resistor. Dark-current behavior, diode capacitance, and the required signal bandwidth determine the practical feedback resistance.

🔋

Battery-Powered Precision Instrument

The AD515AKH supports portable measurement systems because its typical quiescent current is 0.6 mA and its maximum is 1.5 mA. A single low-power FET-input amplifier can monitor battery current, high-resistance sensors, or environmental probes without consuming the power associated with a general-purpose precision amplifier. Use a low-noise regulator, maintain consistent grounding between the sensor and analog return, and include a power-on reset strategy if the measurement must start from a defined state. Battery chemistry, standby leakage, and cable leakage can ultimately dominate the complete instrument budget.

🏭

Chemical and Gas Sensor Monitoring

AD515AKH is appropriate for amperometric gas sensors, humidity elements, conductivity probes, and other transducers that produce signals through very high source impedances. Its 150 fA maximum input bias current reduces unintended interaction with the sensor, and the 1.5 mA maximum supply current supports compact field instruments. The design should include guarded input routing, contamination-resistant board assembly, and defined electrode-bias polarity. Filter capacitors must be selected to avoid excessive settling time or excessive leakage across the sensor itself.

🖥️

Capacitance and Charge Sensing

AD515AKH can serve as the input amplifier for capacitive touch sensors, charge-sensitive detectors, and high-impedance capacitance-measurement systems. The low input bias current limits state-space charging of the sensing node, helping preserve charge between conversion cycles. Use short guarded traces, a defined virtual ground at the non-inverting input, and a feedback network whose resistance balances capacitor leakage against the required noise performance. The TO-99 package is mechanically robust for laboratory and industrial instrumentation, although the complete assembly must remain clean and dry.

📺

High-Impedance Voltage Divider

AD515AKH is useful when measuring the midpoint of a very high-value resistive divider where the amplifier input current could otherwise create a significant measurement error. With maximum bias current of 150 fA, the device can present a very light load to high-impedance dividers while providing the accuracy benefits of laser-trimmed offset. Layout remains critical: use matched guarding, avoid flux residue around the input node, and select resistor tolerance according to the divider’s real accuracy requirement. Thermal effects in the high-value resistors may exceed the amplifier’s offset contribution.

What is the AD515AKH and what is its maximum input bias current?
The AD515AKH is a monolithic precision, low-power FET-input electrometer operational amplifier with a guaranteed maximum input bias current of 150 fA. According to the Analog Devices AD515A product page and manufacturer datasheet information, the device uses a low-leakage FET input stage to minimize disturbance of high-impedance sources. It is packaged in an 8-pin TO-99 metal can and is intended for precision measurement, photodiode sensing, chemical-electrode interfaces, and other instrumentation requiring very low input current.
What are the key specifications of AD515AKH that engineers should know?
The AD515AKH combines a maximum input bias current of 150 fA with low power consumption, including 0.6 mA typical and 1.5 mA maximum quiescent current. Analog Devices describes the AD515A as a monolithic precision, low-power, FET-input electrometer amplifier with laser-trimmed offset voltage, low drift, and low noise. The device is a single-circuit amplifier in an 8-pin TO-99 package, making it suitable for low-level current measurement and high-source-impedance signal-chain designs.
Where can I download the AD515AKH datasheet PDF?
The official AD515A manufacturer page is the preferred starting point for the AD515AKH datasheet and technical documentation. Analog Devices identifies AD515AKH as a precision, low-power FET-input electrometer operational amplifier with up to 150 fA maximum input bias current. The page also links the device into the broader AD515A family information. For pin assignments and the exact ordering code, use the manufacturer pin-description table and package drawings rather than third-party pinout illustrations.
Where can I find the AD515AKH pinout?
The AD515AKH pin assignments are defined for its 8-pin TO-99 metal-can package in the Analog Devices manufacturer datasheet. The verified product information confirms an 8-terminal TO-99 package with wire leads. Use the manufacturer pin-description table to identify offset null, supply, output, and inverting or non-inverting inputs before assigning PCB connections. Exact pin numbering is not reproduced here because the retrieved product excerpt does not expose the complete pin table.
What is the difference between AD515AKH and AD515ALH?
AD515AKH is specified at 150 fA maximum input bias current, while AD515ALH is specified at 75 fA maximum input bias current. Both are K-style precision electrometer options associated with the AD515A family and use the same 8-pin TO-99 package. AD515ALH therefore offers a 50% lower maximum input-bias-current rating than AD515AKH. The AD515AKH can remain preferable when the 150 fA limit provides adequate source-loading performance and better commercial positioning.
AD515AKH vs AD515AJH: which one is better for high-impedance sensing?
AD515AKH is the better choice when the application benefits from a tighter input-bias-current limit than AD515AJH. The K-grade AD515AKH is guaranteed at 150 fA maximum, compared with 300 fA maximum for the J-grade AD515AJH, reducing the maximum specified bias-current contribution by 50%. For signals where source leakage and thermal electromotive-force effects are critical, that tighter limit can improve measurement certainty; AD515AJH may still be adequate when its specified 300 fA loading is acceptable.
Can AD517SH replace AD515AKH as a drop-in part?
AD517SH is a pin-compatible ADI alternative in the TO-99-8 package, but it should be selected only after checking the complete electrical specifications. The verified cross-reference material identifies a one-circuit, one-package J-FET amplifier in TO-99-8, while AD515AKH has a 150 fA maximum input bias current and 1.5 mA maximum quiescent current. Board-level substitution is practical, but offset, drift, bandwidth, noise, supply range, and temperature-grade requirements must be reconciled against the manufacturer datasheets.
Can AD510LH replace AD515AKH in an electrometer circuit?
AD510LH can be considered as a same-package ADI replacement candidate, but it is not automatically electrically equivalent to AD515AKH. Both are listed as single-circuit amplifiers in TO-99-8, yet AD515AKH is specified at 150 fA maximum input bias current and 1.5 mA maximum quiescent current. Before replacing the circuit, compare input bias current, offset voltage, offset drift, noise, bandwidth, supply voltage, common-mode range, and temperature limits for the exact operating conditions.
What is the best drop-in replacement for AD515AKH?
The closest supported same-brand drop-in candidate is AD515AKH’s own grade-family variants AD515ALH and AD515AJH, both of which retain the 8-pin TO-99 architecture while changing the maximum input-bias-current specification. AD517SH and AD510LH are additional TO-99 comparison candidates, but their broader electrical differences must be reviewed. No cross-brand replacement is presented as confirmed drop-in because the retrieved comparison material does not prove a complete pin and parameter match.
When should I choose AD515AKH over another TO-99 electrometer amplifier?
Choose AD515AKH when a single-channel, low-power FET-input amplifier with a 150 fA maximum bias current is sufficient for the measurement chain. It is especially useful in compact precision instrumentation where its 1.5 mA maximum quiescent current is beneficial. Choose AD515ALH when a stricter 75 fA limit is needed, AD515AJH when 300 fA is acceptable and device positioning favors it, or another TO-99 device when its verified bandwidth, noise, offset, or supply specifications better match the application.
Is AD515AKH suitable for photodiode and high-impedance sensor measurements?
AD515AKH is suitable for photodiode and high-impedance sensor measurements because its FET input limits bias current to 150 fA maximum. That low loading helps preserve signals from high-impedance photodiodes, electrochemical electrodes, and resistive sensors. Performance still depends on guarding, clean boards, low-leakage interconnects, stable power supplies, and appropriate feedback resistors. The amplifier alone cannot overcome contamination or leakage introduced by the PCB and connector system.
How should power and thermal effects be considered when using AD515AKH?
AD515AKH operates with a maximum quiescent current of 1.5 mA, making supply current an important consideration for battery-powered electrometer systems. Keep the regulator quiet and stable because supply ripple can modulate the measured signal and appear as input-referred error. At 18 V and 1.5 mA, the estimated amplifier dissipation is 27 mW, calculated as 18 V times 1.5 mA; actual total dissipation also depends on output current and the external circuit.
Where can I buy AD515AKH and what is its current lead time?
Use the Request a Quote form on this page to request AD515AKH availability, commercial terms, and the current lead time. The verified distributor listing identifies AD515AKH as an in-stock part and shows a unit reference amount, but it does not publish a qualifying quantity-break table or a guaranteed lead-time interval. XAIPART’s quote team can confirm the exact TO-99 ordering code, quantity availability, and shipment schedule against current inventory.
What is the price of AD515AKH?
AD515AKH pricing and current commercial terms are best obtained through the Request a Quote form on this page. The verified distributor listing shows a unit reference amount for the exact AD515AKH ordering code, but it does not provide the explicit quantity breaks required to publish a tiered price table. A quote request provides a current response tied to quantity, package form, delivery requirements, and supply status.
Is AD515AKH in stock and what is its lead time?
The verified distributor listing marks AD515AKH as in stock, but it does not state a firm lead time or expose quantity-break availability. Request a quote on this page to confirm the current stock position, minimum order quantity, and expected dispatch schedule. Inventory can change, so engineers should use the quote response for production planning rather than treating a web listing status as a reservation or scheduled delivery commitment.
What can replace AD515AKH?
AD515ALH and AD515AJH are the most direct documented replacements because they remain in the AD515A family and use the same 8-pin TO-99 package while changing the maximum input-bias-current grade. AD517SH and AD510LH are also identified as TO-99 comparison candidates. A responsible replacement decision must confirm the full pinout and key parameters, particularly bias current, offset, drift, noise, bandwidth, supply range, and temperature limits, before treating any candidate as a drop-in replacement.

Datos de referencia de ingeniería para AD515AKH — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose AD515AKH for a single-channel precision measurement requiring a maximum input bias current of 150 fA and no more than 1.5 mA quiescent current. Select AD515ALH when the source is sufficiently high impedance to justify its tighter 75 fA limit. Consider AD515AJH when 300 fA is acceptable, or when its commercial positioning is preferable. AD517SH and AD510LH share the TO-99-8 format and can simplify board-level substitution, but both require a complete review of bias current, offset, drift, noise, bandwidth, supply range, common-mode range, and temperature behavior. For a production design, treat package compatibility as the starting point rather than the final qualification. The best choice is the candidate whose documented electrical limits meet the measurement error budget at the highest operating temperature, worst-case source impedance, and minimum expected supply voltage.

Comparación con alternativas

Parámetro Este producto AD515ALH AD515AJH AD517SH AD510LH
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Package TO-99-8 metal can TO-99-8 metal can TO-99-8 metal can TO-99-8 metal can TO-99-8 metal can
Number of Pins 8 pins 8 pins 8 pins 8 pins 8 pins
Amplifier Type J-FET electrometer operational amplifier AD515A-family FET-input operational amplifier AD515A-family FET-input operational amplifier J-FET operational amplifier General-purpose operational amplifier
Number of Circuits 1 circuit 1 circuit 1 circuit 1 circuit 1 circuit

Diferenciadores clave

  • Lower guaranteed input bias current within the AD515A family (frente a AD515AJH)
  • Tighter leakage limit than the broader J-grade option (frente a AD510LH)
  • Lower power ceiling than AD517SH is not established (frente a AD517SH)

Notas de diseño

Guard the high-impedance input and keep the sensitive node physically small. Route a guard structure driven by the amplifier’s non-inverting input potential around the input trace and feedback resistor where the application permits it. This reduces surface leakage and capacitive pickup that can exceed the AD515AKH’s 150 fA maximum bias current. Avoid placing high-impedance routes beside switching nodes, relay contacts, or mechanically dirty board areas.

Do not assume that a 150 fA input-current specification eliminates contamination effects. Flux residue, moisture, fingerprints, and connector leakage can create currents far above the amplifier bias current. Clean the assembled board using a process compatible with the sensor and include conformal coating when the operating environment is humid or dusty. Use a defined input bias path so the input cannot float during power-up, testing, or cable disconnection.

Estimated: at a 18 V supply and 1.5 mA maximum quiescent current, the amplifier quiescent dissipation is 27 mW, calculated as 18 V × 1.5 mA. Use a low-noise regulator and place its bypass capacitors near the supply pins. Stable reference and ground planes matter because supply variation and ground movement can appear as input-referred error in a high-gain electrometer measurement, even when the amplifier itself consumes little power.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

The manufacturer product description identifies a commercial-grade precision operational amplifier but does not provide RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statements.

Datos verificados el: 2026-11-18 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

AD515AKH datasheet AD515AKH pinout AD515AKH datasheet pdf AD515AKH replacement AD515AKH equivalent AD515AKH TO-99 pinout AD515AKH 150 fA amplifier AD515AKH low power op amp AD515AKH vs AD515AJH AD515AKH vs AD515ALH AD515AKH photodiode amplifier AD515AKH electrometer circuit Analog Devices AD515AKH AD515AKH price AD515AKH stock

Componentes & términos relacionados

Analog Devices AD515AKH AD515A AD515ALH AD515AJH AD517SH AD510LH electrometer operational amplifier precision operational amplifier analog amplifier IC FET-input amplifier input bias current quiescent current offset voltage offset drift TO-99-8 TO-99 metal can through-hole package electrometer high-impedance sensor photodiode electrochemical sensor RoHS REACH
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ