Analog Devices

AD620BNZ - Low-Power Instrumentation Amplifier | Analog Devices

N.º de pieza: AD620BNZ ✓ Activo
15 µV Vdss 8-pin PDIP Package
MOQ: 1 |

AD620BNZ Descripción general

The Analog Devices AD620BNZ is a low-cost, high-accuracy instrumentation amplifier with one circuit in an 8-pin PDIP package. It provides 15 µV input offset voltage, 1.2 V/µs slew rate, and 1 MHz bandwidth, while its gain can be programmed from 1 to 10,000 using one external resistor. The device accepts supplies from ±2.3 V to ±18 V, making it suitable for precision signal-conditioning systems operating from low-voltage dual rails through conventional laboratory rails.

An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while providing high input impedance, accurate differential gain, and strong rejection of common-mode voltage. Its place in the signal-chain hierarchy is above ordinary operational amplifiers because it combines differential input, gain setting, and common-mode rejection into one integrated circuit. The AD620 is widely used where sensor outputs are small, noisy, and referenced to a voltage that is not ground.

The AD620 architecture is based on a three-op-amp approach with internal gain-setting and absolute-value trimming. According to the Analog Devices AD620 product page, one external resistor programs gains from 1 to 10,000. This simplifies instrumentation designs compared with discrete resistor networks while improving repeatability. The AD620BNZ is identified as a low-power instrumentation amplifier, making it useful where signal fidelity must be balanced against board space and energy use.

The 15 µV offset specification is important for low-level measurements because it limits the input-referred error that can obscure the intended sensor signal. Its 1 MHz bandwidth and 1.2 V/µs slew rate provide adequate speed for many sensor, bridge, and data-acquisition signals, although higher-bandwidth instrumentation amplifiers may be preferable for faster waveforms. The dual supply range of ±2.3 V to ±18 V supports both compact systems and conventional bipolar analog rails.

Typical uses include strain-gauge and load-cell bridge conditioning, thermocouple and RTD signal chains, biomedical instrumentation, industrial process measurement, and precision data acquisition. The AD620 is also useful in current-shunt monitoring and laboratory sensor interfaces where a common-mode voltage varies substantially from ground. Its high input impedance helps preserve the source signal, while differential amplification rejects much of the offset common to both inputs.

For a new design, check input common-mode range, output swing, supply voltage, gain-set resistor accuracy, and settling time against the required signal bandwidth. Use the gain-setting resistor recommended by the manufacturer and place it close to the device. Confirm that the selected gain, output voltage, and input polarity do not exceed the signal-chain limits before laying out the board.

Alternativas directas para AD620BNZ — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con AD620BNZ (mismo factor de forma y huella) — difiere en Package, Product Type, Mounting Type, Gain Range, Supply Voltage Range.

Analog Devices
Package: 8-lead PDIP
Product Type: Low-cost, low-power, high-accuracy instrumentation amplifier
Comparar con AD620BNZ →
Analog Devices
Product Type: Instrumentation amplifier
Comparar con AD620BNZ →
Texas Instruments
Package: 8-pin plastic DIP (PDIP)
Product Type: Precision low-power instrumentation amplifier
Supply Voltage Range: ±18 V
Comparar con AD620BNZ →
Analog Devices
Package: 8-pin SOIC (SO-8)
Mounting Type: Surface Mount
Gain Range: 1 to 10,000 (single external resistor)
Comparar con AD620BNZ →

AD620BN

✅ Sustitución directa
📦 PDIP-8
Same AD620 architecture and PDIP-8 footprint; ordering and lifecycle conditions require confirmation

📋 Alternativa de referencia (no en el catálogo)

AD620ANZ

✅ Sustitución directa
Analog Devices
📦 PDIP-8
Low-cost, low-power, high-accuracy instrumentation amplifier · 1 channel · 1 to 10,000 · One external resistor · 1 MHz · 1.3 mA · 2 nA

Consulte el precio

Ver hoja de datos →

AD621BNZ

✅ Sustitución directa
Analog Devices
📦 PDIP-8
Instrumentation amplifier · 1 circuit · ±2.3 V to ±18 V · 8-pin PDIP · 125 µV typical · 800 kHz typical · 1.2 V/µs typical · 120 dB to 130 dB, condition dependent

Consulte el precio

Ver hoja de datos →

LT1167IS8

✅ Sustitución directa
Analog Devices
📦 PDIP-8
Instrumentation Amplifier · 1 · 1 to 10,000 (single external resistor) · 7.5 nV/√Hz at 1 kHz · 60 µV · 1.2 V/µs · 1 MHz · 0.9 mA

Consulte el precio

Ver hoja de datos →

AD620BNZ Valores máximos y características eléctricas

Amplifier Type Instrumentation Amplifier
Number of Circuits 1 circuit
Gain Range 1 to 10,000
Gain Setting 1 external resistor
Input Offset Voltage 15 µV
Slew Rate 1.2 V/µs
Bandwidth 1 MHz
Supply Voltage Range ±2.3 V to ±18 V
Encapsulado 8-pin PDIP
Tipo de montaje Through-hole
Power Class Low-power instrumentation amplifier

Guía de configuración de pines de AD620BNZ 8-pin pdip

Configuración de pines para AD620BNZ (encapsulado 8-pin pdip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.

Diagrama de patillaje del encapsulado 8-pin pdip para AD620BNZ

No hay datos detallados de patillaje disponibles para AD620BNZ.

Consulte la hoja de datos para ver la configuración completa de patillas.

Aplicaciones típicas

AD620BNZ es adecuado para 6 aplicacións: Load-Cell Bridge Amplification, Precision Current-Shunt Measurement, Thermocouple and RTD Conditioning, Biomedical Instrumentation, Industrial Process Measurement, Precision Data Acquisition.

🏭

Load-Cell Bridge Amplification

The AD620BNZ fits load-cell and strain-gauge front ends because it amplifies the small differential voltage produced by a resistive bridge while presenting a high input impedance to the sensing element. Its gain can be programmed from 1 to 10,000 with one external resistor, allowing the amplifier to compensate for both low-level millivolt outputs and larger bridge signals. The 15 µV input offset specification is particularly relevant when the bridge output is only slightly above the measurement floor. In the completed design, confirm that bridge excitation and signal common-mode voltages remain inside the amplifier's operating limits, and place the gain resistor close to the device to reduce sensitivity to board leakage and interference.

⚡

Precision Current-Shunt Measurement

The AD620BNZ is suitable for measuring the differential voltage generated across a current shunt when the shunt voltage is small and the common-mode voltage can change substantially. Differential amplification rejects shared voltage on the shunt sense lines, while the single external gain-setting resistor simplifies calibration-oriented analog circuitry. The device's 1 MHz bandwidth and 1.2 V/µs slew rate are appropriate for many current-monitoring loops that do not require high-speed waveform fidelity. Keep the Kelvin sense connections routed as a matched pair and verify that the burden voltage and common-mode excursion stay within the operating limits for the selected operating grade.

🌡️

Thermocouple and RTD Conditioning

The AD620BNZ can condition low-level thermocouple or RTD signals when the design requires differential input, adjustable gain, and rejection of common-mode voltage. A thermocouple produces a small voltage relative to a temperature-dependent reference, making the 15 µV offset characteristic relevant to resolution near the lower end of the measurement range. Programmable gain from 1 to 10,000 provides flexibility across different sensor sensitivities. The instrumentation amplifier should be paired with suitable cold-junction compensation for thermocouples, and its input bias current, common-mode range, and offset drift must be compared with the sensor impedance and required accuracy before final selection.

💊

Biomedical Instrumentation

The AD620BNZ is appropriate for biomedical instrumentation front ends that measure small differential sensor voltages while rejecting common-mode interference from the body, cables, and nearby equipment. Its single-circuit instrumentation-amplifier architecture reduces the number of matched precision resistors normally required for a discrete difference amplifier, and the 15 µV input offset helps preserve weak physiological signals. The AD620BNZ is normally used with suitable input protection, isolation, filtering, and patient-safety circuitry rather than as a complete medical front end. The final system must be evaluated for leakage current, electrode protection, noise, electrical isolation, and the applicable medical-device requirements.

🏭

Industrial Process Measurement

The AD620BNZ supports industrial process-measurement systems that receive low-level differential signals from pressure, flow, level, or vibration sensors. Differential input and high input impedance help preserve sensor output, while the 1 to 10,000 gain range can adapt the amplifier to different sensor sensitivities without a complex external network. The ±2.3 V to ±18 V supply range accommodates compact dual-rail electronics and conventional bipolar instrumentation supplies. In industrial deployments, verify the operating-temperature grade, isolate long sensor wiring appropriately, provide surge and transient protection, and maintain a low-impedance reference connection so ground differences do not dominate the measurement.

🖥️

Precision Data Acquisition

The AD620BNZ is useful as the analog input stage in precision data-acquisition systems where differential sensor outputs must be amplified before conversion. The 1 MHz bandwidth accommodates many moderate-rate measurements, while the 15 µV offset limits one important source of signal-chain error. A gain of 1 is useful for higher-level inputs, and higher programmed gains increase sensitivity to weak signals. The anti-alias filter, gain resistor, input protection, and converter interface must be designed together so that settling behavior and source impedance are compatible with the sample rate. Confirm output swing, input range, supply noise, and acquisition timing before selecting the exact AD620 ordering option.

Resumen de productos recomendados

AD620BN Related PDIP-8 AD620-family bridge amplifier Se usa en: Load-Cell Bridge Amplification, Thermocouple and RTD Conditioning, Industrial Process Measurement LT1167 Pin- and gain-compatible AD620 replacement Se usa en: Load-Cell Bridge Amplification, Thermocouple and RTD Conditioning, Industrial Process Measurement AD620ANZ Analog Devices Se usa en: Precision Current-Shunt Measurement, Biomedical Instrumentation, Precision Data Acquisition AD621BNZ Analog Devices Se usa en: Precision Current-Shunt Measurement, Biomedical Instrumentation, Precision Data Acquisition
What is the AD620BNZ and what does it do?
The AD620BNZ is a single-circuit, low-power instrumentation amplifier that amplifies the difference between two input signals. According to the Analog Devices AD620 product page, one external resistor sets gains from 1 to 10,000. The device is packaged in an 8-pin PDIP and is intended for precision sensor conditioning, bridge measurement, and other applications requiring high input impedance and common-mode rejection.
What are the key specifications of AD620BNZ that engineers should know?
The AD620BNZ combines a 15 µV input offset voltage, 1.2 V/µs slew rate, 1 MHz bandwidth, and programmable gain from 1 to 10,000. It operates from ±2.3 V to ±18 V and uses one external resistor for gain programming. These values come from the Analog Devices product information and the AD620 family documentation, making the device appropriate for low-level differential measurements with moderate bandwidth requirements.
How do I set the gain of an AD620BNZ?
The AD620BNZ uses one external gain-setting resistor to select a gain from 1 to 10,000. According to the Analog Devices AD620 product page, the resistor is the only external component required to program the gain. Use the manufacturer's gain equation and resistor table when selecting the value, and account for resistor tolerance because its error contributes directly to the overall gain error.
Where can I download the AD620BNZ datasheet PDF?
The AD620BNZ datasheet and product information are available from Analog Devices through the official AD620 product page. The page provides the family-level electrical characteristics, gain-setting information, pin descriptions, and application guidance for the AD620 in 8-lead SOIC and DIP packages. Use the AD620BNZ ordering information to confirm that the PDIP-8 device and its temperature or grade requirements match the design.
Where can I find the AD620BNZ pinout?
The AD620BNZ pinout is documented in the pin-configuration section of the Analog Devices AD620 datasheet linked from the official product page. The device uses an 8-pin PDIP package with gain-program, input, reference, output, and supply connections. Use that pin-description table when assigning PCB tracks and verify the exposed functional names against the selected ordering option before fabrication.
What supply voltage does the AD620BNZ require?
The AD620BNZ operates from ±2.3 V to ±18 V, according to the AD620 family information. This range supports low-voltage dual-rail systems and conventional bipolar laboratory supplies. The input common-mode and output swing limits are not identical to the supply range, so verify both rails can accommodate the sensor voltage and the required output waveform before selecting the power supply.
Is the AD620BNZ suitable for load-cell and strain-gauge measurements?
Yes, the AD620BNZ is suitable for load-cell and strain-gauge measurements because it provides differential amplification, high input impedance, 15 µV input offset voltage, and adjustable gain up to 10,000. Place the bridge excitation and signal return carefully to minimize ground-potential errors. Confirm the bridge excitation voltage, common-mode range, output swing, and system noise requirements before finalizing the circuit.
When should I choose AD620BNZ over AD620ANZ?
Choose AD620BNZ when the required operating-temperature grade and qualification conditions match that ordering option; choose AD620ANZ when its grade better matches the design. Both are described as 8-pin PDIP AD620 variants in the comparison information. The important selection checks are temperature range, availability, qualification needs, and exact ordering-code requirements rather than the gain architecture.
What is the difference between AD620BNZ and AD621BNZ?
The AD620BNZ and AD621BNZ are closely related AD620-family instrumentation amplifiers in 8-pin PDIP packages, but their gain-setting implementations differ and the AD621 is commonly associated with a more accurate gain resistor. According to the manufacturer family architecture, the AD620 uses one external gain resistor, whereas the AD621 incorporates an internal gain resistor. Confirm the required gain and external component count before substitution.
Can LT1167 replace AD620BNZ in an existing design?
The LT1167 can be a pin- and gain-compatible replacement for many AD620 designs, according to the replacement comparison information for the AD620. Before exchanging it for an AD620BNZ, verify supply range, input and output common-mode limits, offset voltage, bandwidth, settling behavior, and noise in the exact circuit. A pin-compatible footprint does not by itself guarantee identical transient performance.
What is the best drop-in replacement for AD620BNZ?
The LT1167 is the clearest documented drop-in replacement for the AD620 family because it was designed for pin and gain compatibility, while the AD620BN, AD620ANZ, and AD621BNZ offer related same-package options with different ordering or gain details. The correct replacement depends on required temperature grade, gain accuracy, bandwidth, supply voltage, and input/output range. Verify the pinout and operating limits before committing to a substitution.
AD620BNZ versus LT1167: which is better for a low-level sensor amplifier?
The AD620BNZ is preferable when its 15 µV offset, 1 MHz bandwidth, 1.2 V/µs slew rate, and one-resistor gain range match the measurement. The LT1167 is preferable when its verified pin and gain compatibility makes it the preferred replacement or its electrical characteristics better fit the circuit. Compare offset drift, noise, bandwidth, settling time, supply range, and common-mode limits in the completed design.
What can replace an AD620BNZ?
An AD620BNZ can be replaced by the LT1167 in many applications because it is specifically described as pin and gain compatible with the AD620. Related AD620-family PDIP options include AD620BN, AD620ANZ, and AD621BNZ, but their ordering grade or gain implementation may differ. Treat all options as engineering replacements only after checking the exact pinout, supply voltage, common-mode range, output swing, and gain equation.
Is AD620BNZ the same as AD8221?
No, the AD620BNZ and AD8221 are not automatically interchangeable even though both are instrumentation amplifiers. The AD620BNZ is an 8-pin PDIP device, while the AD8221 is commonly associated with an 8-pin SOIC package, making the physical footprints different. The AD8221 may provide similar signal-conditioning functions, but it requires a different PCB footprint and a complete electrical review rather than a drop-in substitution.
Where can I buy AD620BNZ and check its current lead time?
Use the Request a Quote form on this page to request the current AD620BNZ price, stock position, minimum order quantity, and lead time for the required quantity. The manufacturer lists the AD620 as a family that includes the AD620BNZ package configuration, but commercial conditions can change. Provide the target quantity, acceptable packaging, and required date when requesting the quotation.

Datos de referencia de ingeniería para AD620BNZ — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the AD620BNZ for precision low-level differential measurements when its 15 µV offset, 1 to 10,000 gain range, 1 MHz bandwidth, and dual ±2.3 V to ±18 V supply range satisfy the sensor and system requirements. Select AD620BN when that ordering option has better availability or a preferred lifecycle condition, and confirm its temperature-grade requirements. Consider AD620ANZ when its specified ordering grade better matches the deployment environment. Use AD621BNZ only when its different gain implementation and associated accuracy characteristics are appropriate. Choose the LT1167 when an existing design requires a documented pin- and gain-compatible AD620 replacement, but verify noise, bandwidth, supply limits, settling, and common-mode behavior. AD8221 and AD8222 are related instrumentation amplifiers rather than PDIP-8 drop-ins and require a footprint or board-layout change.

Comparación con alternativas

Parámetro Este producto AD620BN AD620ANZ AD621BNZ LT1167
Brand Analog Devices Analog Devices Analog Devices Analog Devices Linear Technology
Package PDIP-8 PDIP-8 PDIP-8 PDIP-8 PDIP-8
Amplifier Type Instrumentation Amplifier Instrumentation Amplifier Instrumentation Amplifier Instrumentation Amplifier Instrumentation Amplifier

Diferenciadores clave

  • One-resistor gain programming (frente a AD621BNZ)
  • Documented low-level precision (frente a LT1167)
  • Single-circuit integration (frente a AD620ANZ)

Notas de diseño

Check the full signal path before applying gain. The AD620BNZ supports gains from 1 to 10,000 with one external resistor, but high gain also magnifies offset, noise, and error contributed by the source impedance. Confirm that the input common-mode voltage and required output voltage remain within the operating limits. For a drop-in LT1167 substitution, verify supply voltage, bandwidth, settling behavior, and output swing rather than relying only on pin compatibility.

Route the two differential inputs as a matched pair and connect the gain-setting resistor close to the amplifier. Keep high-impedance input nodes away from switching nodes and provide a low-impedance return for the reference pin. This minimizes leakage, induced noise, and ground-potential errors, which are especially important when the AD620BNZ is configured for high gain on low-level sensor signals.

Determine the required bandwidth from sensor dynamics, noise, and the downstream converter rather than selecting gain from sensitivity alone. The AD620BNZ is rated for 1 MHz bandwidth and 1.2 V/µs slew rate, so a large-amplitude output at high frequency may become slew-rate limited. Include an anti-alias filter and verify that source impedance, settling time, and gain selection produce acceptable acquisition accuracy.

Información de cumplimiento

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Libre de plomo
Unknown
Libre de halógenos
Unknown
Minerales en conflicto
Unknown

The AD620 family is an analog instrumentation amplifier rather than an automotive-qualified component. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer or current product documentation.

Búsquedas relacionadas

AD620BNZ datasheet AD620BNZ pinout AD620BNZ datasheet pdf AD620BNZ schematic AD620BNZ equivalent AD620BNZ replacement AD620BNZ cross reference AD620BNZ vs LT1167 AD620BNZ PDIP-8 pinout AD620BNZ price AD620BNZ stock Analog Devices AD620BNZ

Componentes & términos relacionados

Analog Devices AD620BNZ AD620 AD620BN AD620ANZ AD621BNZ LT1167 AD8221 AD8222 instrumentation amplifier differential amplifier low-dropout regulator precision analog signal conditioner common-mode rejection input offset voltage slew rate bandwidth gain-setting resistor PDIP-8 DIP package through-hole package load-cell bridge strain-gauge measurement current-shunt measurement precision data acquisition
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ